Loading…
Loading…
| # | Company | Amount | Status |
|---|---|---|---|
| 1 | ₹27,122.30Admitted-Finance U M 10 POLOVICTORY CINEMA COMPLEX STATION ROAD JAIPUR 302006 | JAIPUR | RAJASTHAN | 302006 | Admitted-Finance | |
| 2 | ₹42,704.20Admitted-Finance | Admitted-Finance | |
| 3 | ₹67,271.80Admitted-Finance B 4 25 DEVANSH ENCLAVE VAISHALI NAGAR CHITRAKOOT SCHEME JAIPUR RAJASTHAN 302021 VAISHALI NAGAR VAISHALI NAGAR | JAIPUR | RAJASTHAN | 302021 | Admitted-Finance |
| Sl No | Description | Qty | Unit | SDG POWER EQUIPMENTS | SHRIRAM ELECTRONICS | M/S AIRTECH ENTERPRISES |
|---|---|---|---|---|---|---|
| 1.00All in all General servicing and cleaning of various type airconditioners During Defect Laibility Period of Equipments including compressor, condensing/ cooling coil , refrigerant piping , fan motor , remote , charging of refrigerant when ever required as per OEM's recommendations to meet out the efficient performance of the equipment. | ||||||
| 1.01 | 1.0/1.5/2.0 Tr window type air conditioner (Invertor/Non Invertor type) | 1 | Each per Month | 385 ₹454.3 | 500 ₹590 | 20 ₹23.6 Lowest |
| 1.02 | 1.5/1.8/2.0 Tr Split type air conditioner (Invertor/Non Invertor type) | 1 | Each per Month | 385 ₹454.3 | 500 ₹590 | 20 ₹23.6 Lowest |
| 2.00All in all comprehensive maintenance of various type airconditioners After Defect Laibility Period of Equipment including repair / replacement of compressor, condensing/ cooling coil , refrigerant piping , fan motor , remote , charging of refrigerant when ever required and periodical servicing as per OEM's recommendations to meet out the efficient performance of the equipment. | ||||||
| 2.01 | 1.0/1.5/2.0 Tr window type air conditioner (Invertor/Non Invertor type) | 1 | Each per Month | 385 ₹454.3 Lowest | 600 ₹708 | 385 ₹454.3 Lowest |
| 2.02 | 1.5/1.8/2.0 Tr Split type air conditioner (Invertor/Non Invertor type) | 1 | Each per Month | 385 ₹454.3 Lowest | 650 ₹767 | 395 ₹466.1 |
| 3.00Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping with fittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing, support with MS hanger on ceiling or recessed in wall with chasing & plastering with 6 mm thick closed cell elastomeric nitrile rubber insulation including leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . | ||||||
| 3.01 | 20 mm | 1 | per meter | 700 ₹826 | 180 ₹212.4 | 90 ₹106.2 Lowest |
| 3.02 | 25 mm | 1 | per meter | 800 ₹944 | 180 ₹212.4 | 110 ₹129.8 Lowest |
| 4.00 | Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR | 1 | Each | 1,200 ₹1,416 | 800 ₹944 | 300 ₹354 Lowest |
Tender Value
₹75 L
EMD Value
₹1.5 L
Closing Date
6 Oct 2025, 5:00 pmClosed
Medical Suprintendent, SMS Hospital, Jaipur
SMS Hospital, Jaipur
Rate contract for maintenance and repair services (CAMC) of Split and Window type air conditioner for two year at SMS Hospital, Jaipur
2025_SMSMC_500665_1
11_12.09.2025
Open Tender
Miscellaneous Services
Item Wise
730 days
SMS Hospital
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
Medical Suprintendent, SMS Hospital, Jaipur
₹1.5 L
Yes
SMS Hospital, Jaipur
29 Nov 2025
15 Sept 2025
7 Oct 2025
15 Sept 2025
6 Oct 2025
24 Sept 2025
19 Sept 2025
All in all General servicing and cleaning of various type airconditioners During Defect Laibility Period of Equipments including compressor, condensing/ cooling coil , refrigerant piping , fan motor , remote , charging of refrigerant when ever required as per OEM's recommendations to meet out the efficient performance of the equipment.
1.0/1.5/2.0 Tr window type air conditioner (Invertor/Non Invertor type)
1.5/1.8/2.0 Tr Split type air conditioner (Invertor/Non Invertor type)
All in all comprehensive maintenance of various type airconditioners After Defect Laibility Period of Equipment including repair / replacement of compressor, condensing/ cooling coil , refrigerant piping , fan motor , remote , charging of refrigerant when ever required and periodical servicing as per OEM's recommendations to meet out the efficient performance of the equipment.
1.0/1.5/2.0 Tr window type air conditioner (Invertor/Non Invertor type)
1.5/1.8/2.0 Tr Split type air conditioner (Invertor/Non Invertor type)
Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping with fittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing, support with MS hanger on ceiling or recessed in wall with chasing & plastering with 6 mm thick closed cell elastomeric nitrile rubber insulation including leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR
Supply, installation, testing and comissioning of interconnecting copper refrigerant piping of DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink Mark Brand Printing on Hard Tubes should be present. duly insulated with tubular elastomeric nitrile rubber FM/UL approved with high water vapor diffusion resistance and low thermal conductivity should be certified 'Class O' in Fire Propagation as per BS 476 Part 6 including chase cutting andfilling with mortar, Slotted channel supports mounted on 10 mm threaded rod at suitable spacing the exposed piping shall be wrapped with glass woven cloth and lag coating for vapour barrier and weather protection. Joints shall be covered with nitrile rubber tape of 3 mm thick complete as required of following sizes. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
12.7 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick)
6.4 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick)
Supplying and drawing flexible / stranded bare copper conductor, PVC / XLPE insulated, overall aluminium mylar tape shielded ATC drain wire and outer PVC sheathed industrial Instrumentation (shielded)cables voltage grade 300/500 V as per BS /EN 50288-7 in existing surface or recessed PVC/ MS conduit/casing capping / Cable tray / Open Duct making connections, testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for cables. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR
4 core x 2.5 Sq.mm
Supplying and charging of fresh refrigerant and testing of performance of air conditioner/ fridge/ water cooler of following capacity including capillary and strainer/ filter.
1.5 TR Window/ Split A.C.
2.0 TR Window/ Split A.C.
Replacement of defective compressor by company repaired compressor as per OEM recommendations of following gadgets including testing etc. as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.
P & Replacement of condensing/ cooling coil of copper fins for following capacity A.C./ Water cooler/ Fridge as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.
Shifting of existing/new air conditioners split type of various make & capacity including drain pipe of air conditioner as required including making connection testing etc. as required.
Shifting of existing/new air conditioners split type of various make & capacity including copper pipe, drain pipe and electrical wire and making hole for fixing of air conditioner as required including making connection testing etc as required.
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .