Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
Refer Docs
Closing Date
3 Sept 2024, 2:55 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Ajay Mankotia
RETAIL, Bharat Petroleum Corporation Limited
Bidders to quote percentage above or below the rates published. bidders to quote above or below and percentage at which they are ready to work
17460
1000422294
Limited Tender
Works
RETAIL
17 Apr 2025
12 Aug 2024
3 Sept 2024
12 Aug 2024
3 Sept 2024
12 Aug 2024
12 Aug 2024 - 2 Sept 2024
0.75 HP STP(SUBMERSIBLE TURBINE PUMP)
WITH FLAME PROOF ELECTRICAL CONNECTION
01. Yes AS PER CCOE APPROVAL R1(1)136/DOLPHIN/384/11
CPCB REGULATIONS 1x15KL. U/G TANK IN EARTHEN/PIT
02. Yes ON MS CLASS 'A' OF (SIZE=2.00X5.00M) DATE = 13.02.2007
PNGRB REGULATIONS
LONG CCOE'S APPR. REF. P-6(5) 82 AUTOMATIC TANK GAUGING SYSTEM
WITH HOLDING DOWN DT. 07.08.2001 R1(1)136/GEMSPL/384 V
PESO REGULATIONS (AS PER IS -10987 : 1998) DATE = 30.11.2011 0.23m THK. & 1.20m
05. Yes WITH HOLDING DOWN ARRANGEMENT
LM REGULATIONS EXHAUST FITTED WITH HIGH BOUNDARY WALL
06. Yes SPARK ARRESTOR
LOCAL BY LAWS & OTHER APPROVALS
LAYOUT DESIGN/ FACILITIES AS PER INTERNAL GUIDELINES
EXTEND VENT PIPE 4m HIGH
T/L DECANTATION IN DRIVE OUT POSITION Yes. Shown in the drawing
& 4m CLEAR ALL ROUND 1.50 5 NOS SAND
IN CASE OF RESTRICTED FORECOURT AREA WRT
SALES/ TRAFFIC, IS THERE STOPPAGES/ SUSPENSION NOT APPLICABLE BUCKET
(PARTY/ FULLY) DURING DECANTATION WITH DUE 1x20KL. U/G TANK IN EARTHEN/PIT ON HSD CANOPY TYPE
CORDONING OF THE AREA? MS 1 V F SAMPLE CONTAINER ROOM 0.75x0.86 AUTOMATION FORE COURT
CLASS 'B' OF (SIZE=2.00x6.75M) LONG 20KL
D.G. SET 1.2x1.5 D TOILET D1.2x1.5
10. NOT APPLICABLE S INCLOSURE 0.50x1.50 BLOCK CONTROLLER (FCC)
VRS PROVISIONING DONE AS PER THE APPLICABILITY CCOE'S APPR. REF. P-6(5) 82 WITH HOLDING HSD D 4.54x3.12
11. Yes DOWN DT. 07.08.2001(AS PER IS -10987 : 1998) 1.50 FILL POINT'S 4m 14.00 ROOM
1.2x1.5 CCOE NAGPUR VIDE HIS LETTER
STARTING GATE CONCEPT BASED PLACEMENT OF FACILITIES, TO THE EXTENT POSSIBLE 2 VENT 1.2x1.5
WITH HOLDING DOWN ARRANGEMENT CLEAR ALL ROUND
12. Yes PIPE'S LADIES
EXISTING STRUCTURE/FACILTIES WITH MANDATED CIRCLE OF DISTANCE IN KEY PLAN V TOILET
COLORATION OF FACILITIES DONE WITHOUT MISSING OUT ANY FACILITIES? COOLER
YES. MINIMUM 4.24M FOR AMETHI DISTRICT AS 0.75 HP STP(SUBMERSIBLE TURBINE PUMP) S
14. MPD ON MS/SPEED/HSD EMERGENCY STOP atg D
GROUND WATER LEVELS ARE NOT LESS THAN 4M PER CGWB WEBSITE REPORT DATED MAY2019 WITH FLAME PROOF ELECTRICAL CONNECTION LUBE
(CLASS'A'&'B') SWITCH POSITION STORE RS
15. YES. SHOWN IN THE DRAWING AS PER CCOE APPROVAL R1(1)136/DOLPHIN/384/11 console 1.8x1.5
AUTOMATION SYSTEM IS INCLUDED IN NIP & MENTIONED IN DRAWING DATE = 13.02.2007 3x6x2
YES. WILL PROVIDE 80MM PAVER AREA OF SALES
PAVER BLOCK DRIVEWAY IS PROPOSED 1900 SQM (DRIVEWAY & APPROACH ) 1.00 GW
DSM. EMERGENCY STOP
17. NOT APPLICABLE
0.23 THK. AND 3.0M HIGH 1.50 V
SWITCH POSITION
VRS SYSTEM PROVIDED AND SHOWN IN LAYOUT BOUNDARY WALL D F
18. AUTOMATIC TANK GAUGING SYSTEM S COLUMN EXTINGUISHER
BUILDING HOUSING SENSITIVE POPULATION AREA WITHIN 30M/50M NO
R1(1)136/GEMSPL/384 V D 1.50m HIGH
20KL OFFICE ELECT. FROM G.L.
DATE = 30.11.2011 ROOM ROOM
19. THE OUTLET (OPENING) OF THE VENT PIPE SHALL BE COVERED WITH TWO
WILL BE DONE DURING INSTALLATION
LAYERS OF NON-CORROSIVE METAL WIRE MESH , HAVING NOT LESS THAN
11 MESHES ER SQUARE CENTIMETER POLE
1x20KL. U/G TANK IN EARTHEN/PIT
EMERGENCY STOP SWITCH POSITION (2 NO.) TO BE SHOWN IN THE DRAWING SHOWN IN THE DRAWING ON HSD CLASS 'B' OF (SIZE=2.00x6.75M) MPD ON MS/HSD
(CLASS'A'&'B') GW 0.23 THK. AND 1.20M HIGH
LONG CCOE'S APPR. REF. P-6(5)
21. ILLUMINATION SYSTEM:CANOPY AREA/ YARD LIGHTS TO BE SHOWN IN DRAWING SHOWN IN THE DRAWING
2x4x2 1/2Y BOUNDARY WALL
WITH HOLDING DOWN DT. 07.08.2001
22. SAMPLE CONTAINER ENCLOSURE TO BE SHOWN IN DRAWING SHOWN IN THE DRAWING (AS PER IS -10987 : 1998) POLE
23. Yes WITH HOLDING DOWN ARRANGEMENT 14.50 6.00 14.50 LANDSCAPING
SETBACKS ARE AS PER THE LOCAL REGULATIONS
24. PWD NOC APPLIED
IRC REGULATIONS NOT MENTIONED LANDSCAPING
POLE MPD ON MS/HSD
CNG facility cannot be
accommodated PROPOSED BUILDING LINE
(SIZE=14.0x16x6.0M HEIGHT) 4.50 5.00
due to space constraint CCOE.APPROVAL NO.
G-40(NC)P-40 DT.26.07.1989 HOARDING BOARD
0.23MTHICK 0.30M
BORE WELL (7.0m DEEP) FOR NO SMOKING BORE WELL (7.0m DEEP) FOR
RAIN WATER HARVESTING POLE INGRESS SIGN RAIN WATER HARVESTING
MS DRAIN WITH MS GRATING BUFFER 3.00 MS DRAIN WITH MS GRATING
R.O.W. LINE POLE
POLE R.O.W. LINE
2.0M SPAN R.C.C. SLAB R.L. =99.55 R.L. =99.55 2.0M SPAN R.C.C. SLAB
CULVERT WITH IRON 2.0m WIDE OPEN DRAIN 2.00 CULVERT WITH IRON
GRATING (IRC:SP:13) GRATING (IRC:SP:13)
30.00 SEPARATOR ISLAND
(275mm RAISED TURFED) EA
0.23MTHICK 0.30M
30.00 RTHEN SHOU
0.23MTHICK 0.30M
ULDER HIGH KERB WALL HIGH KERB WALL
0 R=1.5 N LANE 5.50M
R=1.5 0.23MTHICK 0.30M 0 WIDE
CHEVRON MARKING
1m WIDE EARTHEN SHOULDER 1m WIDE EARTHEN SHOULDER
1.50m WIDE PAVED SHOULDER 1.50m WIDE PAVED SHOULDER 1.50 1.50m WIDE PAVED SHOULDER
TO AYODHYA (N. H. 330A) TO AYODHYA
CL OF THE 9.00m WIDE CARRIAGE WAY
4.00m WIDE DIVIDER
TO RAEBARELI TO RAEBARELI
C OF THE 9.00m WIDE CARRIAGE WAY
1.50m WIDE PAVED SHOULDER 1.50m WIDE PAVED SHOULDER 1.50m WIDE PAVED SHOULDER
1m WIDE EARTHEN SHOULDER 1m WIDE EARTHEN SHOULDER 1m WIDE EARTHEN SHOULDER
Between Km Stone No. 55 to 56, On Raebareli - Ayodhya, Road, At. Village - Alinagar ,Tehsil - Musafirkhana , District - Amethi (U.P.) Near Km Stone No. 56 ( NH. 330A) (CH.55+ 988)
ref Mail dated 31st July-Building Size Cannot be reduced due to statutory
PROJECTED MS SALES : 100 KLPM
PROJECTED HSD SALES : 150 KLPM ajay Digitally signed
ajay mankotia by ajay mankotia
Digitally signed kumar Date: 2024.07.31
AJAY KUMAR ROSHAN SAKHARE AJAY KUMAR
TE LUCKNOW SEH-UP GMRE-NORTH
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
17460.pdf
pdf • 1.61 MB
BUDGETDOC_17460.pdf
pdf • 34.45 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .