| Sl No | Description | Qty | Unit | Standard Airconditioning and Refrigeration Engineers L2 | V Save Electronics Pvt Ltd L1 |
|---|---|---|---|---|---|
| 1.00 | Dismantling of existing 4-way cassette ac units in passenger boarding aero bridges without any damage to indoor units in ceiling and outdoor units on external MS stand, older refrigerant copper pipe line including insulation, Condense water drain pipe arrangements including making good the damages to the original finish and shifting to AAI stores etc complete as required. | 3 | Job | 630 ₹1,890 | 1,000 ₹3,000 |
| 2.00 | SITC of 4.0 TR, 4-way Inverter Type Cassette Air Conditioning Unit at the aircraft side of Bukaka Make Passenger Boarding Bridges, installed under the ceiling, complete with outdoor (copper coil) condensing unit having one hermetically sealed Scroll/Rotary-Swing/Twin Rotary compressor, using R-32/R-410A/Non-CFC refrigerant, minimum 3-star rating, suitable for single/three phase 240/415V, 50Hz AC supply, with cordless remote control, including necessary modification of MS supports, threaded rods, accessories, and minor fabrication works as per site requirement etc complete as required.
(Make: Hitachi, Model: RAG348HGE00 or equivqlent as per AAI Preffered Make List) | 3 | Each | 1,16,901 ₹3.5 L | 1,18,000 ₹3.5 L |
| 3.00 | Supply and installation of Nitrile rubber–insulated copper refrigerant piping of size 5/8" (suction line) and 3/8" (discharge line) between Outdoor and Indoor Units of the Air Conditioning system as per BOQ Item No. 1, including necessary fittings, supports, copper brazing, and accessories, complete as required. | 15 | Mtr | 1,250 ₹18,750 | 1,000 ₹15,000 |
| 4.00 | Supply, installation, and fixing of 1" dia. PVC drain pipe for AC units as specified under BOQ Item No. 1, including all necessary fittings, bends, tees, supports, clamps, sealing, and allied accessories, with proper alignment and connection to the nearest drain point, complete in all respects as required. | 15 | Mtr | 95 ₹1,425 | 100 ₹1,500 |
| 5.00 | Supply and installation of 4C x 4 sq.mm Multi Core Copper Conductor PVC insulated and sheathed ‐ FR cable interconnecting control cable between Indoor and Outdoor Units, including necessary connections and terminations as required. | 15 | Mtr | 250 ₹3,750 | 100 ₹1,500 |
Updated dates
Tender Value
₹3.9 L
EMD Value
₹11,800
Closing Date
13 Dec 2025, 6:00 pmClosed
Asst GM Engg (E)
O/o AIRPORT DIRECTOR,VISAKHAPATNAM AIRPORT,VISAKHAPATNAM
Replacement of Cassette type Air Conditioning units at Passenger Boarding Bridges of Visakhapatnam Airport
2025_AAI_255197_1
AAI/VIZAG/ENGG-E/CW/PBB AC/25-26
Open Tender
Electrical Works
60 days
VISAKHAPATNAM AIRPORT, VISAKHAPATNAM
As Per Notice Inviting e-Tender(e-NIT) uploaded
18 documents required · 18 mandatory
₹1,180
₹11,800
2 Apr 2026
13 Nov 2025
15 Dec 2025
14 Nov 2025
13 Dec 2025
14 Nov 2025
14 Nov 2025 - 28 Nov 2025
Amount
Dismantling of existing 4-way cassette ac units in passenger boarding aero bridges without any damage to indoor units in ceiling and outdoor units on external MS stand, older refrigerant copper pipe line including insulation, Condense water drain pipe arrangements including making good the damages to the original finish and shifting to AAI stores etc complete as required.
SITC of 4.0 TR, 4-way Inverter Type Cassette Air Conditioning Unit at the aircraft side of Bukaka Make Passenger Boarding Bridges, installed under the ceiling, complete with outdoor (copper coil) condensing unit having one hermetically sealed Scroll/Rotary-Swing/Twin Rotary compressor, using R-32/R-410A/Non-CFC refrigerant, minimum 3-star rating, suitable for single/three phase 240/415V, 50Hz AC supply, with cordless remote control, including necessary modification of MS supports, threaded rods, accessories, and minor fabrication works as per site requirement etc complete as required. (Make: Hitachi, Model: RAG348HGE00 or equivqlent as per AAI Preffered Make List)
Supply and installation of Nitrile rubber–insulated copper refrigerant piping of size 5/8" (suction line) and 3/8" (discharge line) between Outdoor and Indoor Units of the Air Conditioning system as per BOQ Item No. 1, including necessary fittings, supports, copper brazing, and accessories, complete as required.
Supply, installation, and fixing of 1" dia. PVC drain pipe for AC units as specified under BOQ Item No. 1, including all necessary fittings, bends, tees, supports, clamps, sealing, and allied accessories, with proper alignment and connection to the nearest drain point, complete in all respects as required.
Supply and installation of 4C x 4 sq.mm Multi Core Copper Conductor PVC insulated and sheathed ‐ FR cable interconnecting control cable between Indoor and Outdoor Units, including necessary connections and terminations as required.
Standard Airconditioning and Refrigeration Engineers (BID ID -941835)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.45 MB
TENDDOCPBBACUNITS.pdf
Tender Documents • 21.32 MB
BOQ_294221.xls
BOQ • 0.39 MB
Download all tender documents and submit your bid