GEMC-511687726633595
Awarded to SPARC INFOTECH PRIVATE LIMITED
₹1.4 L
Products
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| 2KVA UPS WITH 120 MINUTE BACKUP 1600 VAH | 2KVA UPS WITH 120 MINUTE BACKUP 1600 VAH | - | 3 NOS | ₹45,200 | 135,600 |
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹1.4 LQualified Make: BPE
Model: 2KVA UPS WITH 120 MINUTE BACKUP 1600 VAH DELHI DELHI 110024 | SOUTH EAST DELHI | DELHI | 110024 | Make: BPE
Model: 2KVA UPS WITH 120 MINUTE BACKUP 1600 VAH | L1 | Qualified | |
| 2 | L2₹1.4 L+₹8,370 (6.17%)Qualified Make: LUMINOUS
Model: LUMINOUS Online UPS 2KVA 1ST FLOOR F 05 PARKER SUITES NH 01 SECTOR 62 KUNDLI SONEPAT HARYANA 131028 SONEPAT SONIPAT HARYANA 131001 | SONIPAT | HARYANA | 131028 | Make: LUMINOUS
Model: LUMINOUS Online UPS 2KVA | L2 | Qualified | |
| 3 | L4₹1.7 L+₹32,400 (23.9%)Qualified Make: ELECTRONICS and CONTROLS.
Model: E &C Make Accenta UPS 2KVA with 120 Minute Battery Back up Min VAH 6400 29 A 2ND PHASE OPP TO ASIAN PAINTS GODOWN PEENYA INDUSTRIAL AREA BANGALORE KARNATAKA 560058 | BENGALURU URBAN | KARNATAKA | 560058 | Make: ELECTRONICS and CONTROLS.
Model: E &C Make Accenta UPS 2KVA with 120 Minute Battery Back up Min VAH 6400 | L4 | Qualified | |
| 4 | L5₹1.7 L+₹33,900 (25.0%)Qualified Make: better power
Model: Make: Better Power, Model: HR 2KVA120M_2 0 BETTER POWER SERVICES PVT LTD A K AZAD ROAD REHABARI KAMRUP ASSAM 781008 | KAMRUP METRO | ASSAM | 781008 | Make: better power
Model: Make: Better Power, Model: HR 2KVA120M_2 | L5 | Qualified | |
| 5 | L5₹1.7 L+₹33,900 (25.0%)Qualified Make: NUMERIC
Model: Numeric omnfiniti 2KVA online Ups with 120 Min. Backup (VAH 6400) with 2 Yr. Warranty G T ROAD AMRITSAR PUNJAB 143105 | AMRITSAR | PUNJAB | 143105 | Make: NUMERIC
Model: Numeric omnfiniti 2KVA online Ups with 120 Min. Backup (VAH 6400) with 2 Yr. Warranty | L5 | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
23 Aug 2018, 5:00 pmClosed
Online UPS Online UPS ( 3 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating in KVA (KVA) 2.0 KVA As per GeM Catalogue. Technology IGBT-PWM with inbuilt isolation transformer MOSFET-PWM with inbuilt isolation transformer
IGBT- PWM with inbuilt isolation transformer
IGBT-PWM without inbuilt isolation transformer Input Power single phase 160V - 260V sinewave
50Hz single phase 160V - 260V sinewave
50Hz
Three phase 300 V - 450V sinewave
50Hz Output power Single phase 230V +/-1% sinewave 50 Hz Single phase 230V +/-1% sinewave 50 Hz
3 Phase 400V +/-1% with alternative user setable setting of 380V +/-1% 50 Hz Backup time (Minutes) 120 15
30
60
90
120
180
240 Minimum VAH (VAH) 6400 Warranty for UPS (Years) 2 1
2
3
4
5 Movable trolly for Batteries Without trollery but with rack With
Without
Without trollery but 1/4 with rack Warranty for battery 2 1
2 Degree of Protection IP20 IP21
IP20 Cabling 5 meters for input and out put With With
Without Paralleling kit for synchronising With With
Without Installation and Commissioning Yes - CONSTRUCTIONAL Minimum thickness of M.S.Sheet Enclosure duly painted (mm) 1.2 - Type of Battery SMF-VRLA conforming to JISC:8702(Pt.I
II&III) - FUNCTIONAL Maximum overshoot and Under shoot of output rated voltage 4 - Voltage Regulation from no load to full load (%) </= 3% - 20% Overload limit for minimum 10 minutes Yes - Overall Efficiency (%) >/=90% - Total Harmonic Distortion(THD) (%) Maximum 3% - 50% Overload limit for minimum 1 minutes Yes - PROTECTION Protection for under voltage at battery terminal at 10.5V per 12 V battery. Yes - Protection of Over voltage
Short Circuit & over load at UPS output terminal Yes - METERING AND INDICATIONS Digital Metering in UPS for AC Input Voltage
Output AC Volt age
Current
Frequency
Battery Voltage and Current Yes - Indicators for mains presence
Battery charging and discharging
Output Over Load
Low Battery Voltage Yes - REPORTS AND Damp Heat : in Yes - 2/4 CERTIFICATION accordance with IS:9000(part 5/sec.2)1981 at Temperature of 40 degree C
two cycles of (12+12) hours each 2007) Dry Heat Test : in accordance with IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) at 55 degree C for 16 hrs Yes - Cold Test : in accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) at -10 degree C for 4 hrs. Yes - Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab covering all technical requirements. Yes - Type Test Certificate No. NTH(SR)/EL(C)/2017/00 413B - Type Test Certificate date 02.12.2017 - Name of Lab NATIONAL TEST HOUSE - Address of Lab TARAMANI
CHENNAI - As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Devarapati Ramanaiah 534201
O/o SSPOs Bhimavaram 3 15
461826
GEM/2018/B/65288
GeM Contract
Online UPS
GeM Contract
15 days
Andhra Pradesh; West Godavari
PRODUCT
Awarded to SPARC INFOTECH PRIVATE LIMITED
₹1.4 L
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| 2KVA UPS WITH 120 MINUTE BACKUP 1600 VAH | 2KVA UPS WITH 120 MINUTE BACKUP 1600 VAH | - | 3 NOS | ₹45,200 | 135,600 |
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Online UPS Online UPS ( 3 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating in KVA (KVA) 2.0 KVA As per GeM Catalogue. Technology IGBT-PWM with inbuilt isolation transformer MOSFET-PWM with inbuilt isolation transformer | - | - | - |
| IGBT- PWM with inbuilt isolation transformer | - | - | - |
| IGBT-PWM without inbuilt isolation transformer Input Power single phase 160V - 260V sinewave | - | - | - |
| 50Hz single phase 160V - 260V sinewave | - | - | - |
| 50Hz | - | - | - |
| Three phase 300 V - 450V sinewave | - | - | - |
| 50Hz Output power Single phase 230V +/-1% sinewave 50 Hz Single phase 230V +/-1% sinewave 50 Hz | - | - | - |
| 3 Phase 400V +/-1% with alternative user setable setting of 380V +/-1% 50 Hz Backup time (Minutes) 120 15 | - | - | - |
| 30 | - | - | - |
| 60 | - | - | - |
| 90 | - | - | - |
| 120 | - | - | - |
| 180 | - | - | - |
| 240 Minimum VAH (VAH) 6400 Warranty for UPS (Years) 2 1 | - | - | - |
| 2 | - | - | - |
| 3 | - | - | - |
| 4 | - | - | - |
| 5 Movable trolly for Batteries Without trollery but with rack With | - | - | - |
| Without | - | - | - |
| Without trollery but 1/4 with rack Warranty for battery 2 1 | - | - | - |
| 2 Degree of Protection IP20 IP21 | - | - | - |
| IP20 Cabling 5 meters for input and out put With With | - | - | - |
| Without Paralleling kit for synchronising With With | - | - | - |
| Without Installation and Commissioning Yes - CONSTRUCTIONAL Minimum thickness of M.S.Sheet Enclosure duly painted (mm) 1.2 - Type of Battery SMF-VRLA conforming to JISC:8702(Pt.I | - | - | - |
| II&III) - FUNCTIONAL Maximum overshoot and Under shoot of output rated voltage 4 - Voltage Regulation from no load to full load (%) </= 3% - 20% Overload limit for minimum 10 minutes Yes - Overall Efficiency (%) >/=90% - Total Harmonic Distortion(THD) (%) Maximum 3% - 50% Overload limit for minimum 1 minutes Yes - PROTECTION Protection for under voltage at battery terminal at 10.5V per 12 V battery. Yes - Protection of Over voltage | - | - | - |
| Short Circuit & over load at UPS output terminal Yes - METERING AND INDICATIONS Digital Metering in UPS for AC Input Voltage | - | - | - |
| Output AC Volt age | - | - | - |
| Current | - | - | - |
| Frequency | - | - | - |
| Battery Voltage and Current Yes - Indicators for mains presence | - | - | - |
| Battery charging and discharging | - | - | - |
| Output Over Load | - | - | - |
| Low Battery Voltage Yes - REPORTS AND Damp Heat : in Yes - 2/4 CERTIFICATION accordance with IS:9000(part 5/sec.2)1981 at Temperature of 40 degree C | - | - | - |
| two cycles of (12+12) hours each 2007) Dry Heat Test : in accordance with IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) at 55 degree C for 16 hrs Yes - Cold Test : in accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) at -10 degree C for 4 hrs. Yes - Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab covering all technical requirements. Yes - Type Test Certificate No. NTH(SR)/EL(C)/2017/00 413B - Type Test Certificate date 02.12.2017 - Name of Lab NATIONAL TEST HOUSE - Address of Lab TARAMANI | - | - | - |
| CHENNAI - As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Devarapati Ramanaiah 534201 | - | - | - |
| O/o SSPOs Bhimavaram 3 15 | - | - | - |
Exempted
4 Sept 2018
10 Aug 2018
contract_GEMC-511687726633595.pdf
GEM_CONTRACT • 0.02 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_461826.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .