| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.6 LAccepted-AOC 137 D THEJAS BURNASHERRY KANNUR KERALA 670013 | KANNUR | KANNUR | KERALA | 670013 | L1 | Accepted-AOC L1 bidder accepted after deducting schedule of credit amount | |
| 2 | L2₹31.6 L+₹5.5 L (21.0%)Rejected-Finance | L2 | Rejected-Finance Other than lowest tenderer | |
| 3 | L3₹31.6 L+₹5.5 L (21.0%)Rejected-Finance 20 2169 PALLURTH PO ERNAKULUM KERALA 682006 | ERNAKULAM | KERALA | 682006 | L3 | Rejected-Finance Other than lowest tenderer | |
| 4 | L4₹31.9 L+₹5.8 L (22.4%)Rejected-Finance DOOR NO IV 400 NEAR RAMANTHALI GHSS RAMANTHALI PO KANNUR 670308 | KANNUR | KERALA | 670308 | L4 | Rejected-Finance Other than lowest tenderer |
Tender Value
₹34.9 L
EMD Value
₹69,800
Closing Date
30 Mar 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(MAINT)EZHIMALA
GARRISON ENGINEER (MAINT) MILITARY ENGINEER SERVICES INDIAN NAVAL ACADEMY POST KANNUR DIST KERALA 670 310
AS PER BOQ AND TENDER DOCUMENTS
2024_MES_645081_1
GE MAINT EZHIMALA 8626
Open Tender
Civil Works
Item Rate
270 days
EZHIMALA
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE MAINT EZHIMALA
₹69,800
Yes
24 Apr 2024
4 Mar 2024
1 Apr 2024
4 Mar 2024
30 Mar 2024
18 Mar 2024
5 Mar 2024 - 12 Mar 2024
Amount
Notes for all items of BOQ:- 1. Contractor should visit the site before quoting the tender to know the working condition of the station. 2. All requisite safety measurers are to be adopted by contractor on site. 3. The contractor shall provide and deploy two nos skilled AC technician and two nos helper (as approved by GE / Engineer-in-charge) shall report at 0900 hrs to JE E&M /Engineer-in-charge to collect the complaints job card in working days & complete the same complaint within 24 hrs. The amount for payments of AC technician & helper are deemed to be included in the quoted rates. 4. The contractor shall also provide AC technician & helper on sunday & holiday if required or asked by JE E/M / Engineer-in-charge. 5. The complaints shall be rectified within 24 hrs, if the complaints is/are not attended/not completed within 24 Hrs (except repair/ replacement of major items like replacement of compressor, cooling coil, condensing coil, fan motor and PCBs) recovery will be done at Rs 1000.00 per complaint per day. 6. For major parts like replacement of compressor, cooling coil, condensing coil, fan motor and PCBs should be rectified within 05 Working days, if the contractor does not rectify within time then the recovery will be done at Rs 1000.00 per complaint per day. 7. After completion of job work complaint, the contractor has to produce job card duly signed by user & JE E/M / Engineer-in-charge. 8. If contractor failed to provide their AC Technician or absent to attend the complaints then recovery will be done at Rs 2000.00 per day.
M&L for servicing of split type AC/Floor standing AC/Cassette AC unit of any capacity any make by removing dust with suitable method, cleaning of air filters, tightening of loose wire, nuts, bolts, washers, servicing of condenser motor/ blower, by oiling, greasing, required welding/bracing, replacement of worn out rubber bushes of condensor motor, washing with water indoor & outdoor coils,setting of grill alignment & knobs, checking for any leakages & brazing, topup of refrigerant gas as per existing, replacement of thermocoal insulations for air tightness as required, testing etc complete all as specified and directed.
M&L for painting the outdoor unit of split type AC/Cassette type AC/Floor standing AC of any capacity/any make including stand by synthetic enamel spray paint as per existing colour and writing MES No complete all as specified and directed.
Removing the unserviceable blower motor/condenser fan motor from the split AC 1.5/2 Ton unit and M&L for rewinding of blower motor, single phase, with super enamelled copper wire of existing gauge including replacement of gunmetal bush of suitable size, cleaning, greasing and refixing of motor, connecting up all including testing and refixing complete all as specified and directed.
S&F in replacement blower motor/condenser fan motor suitable for split type AC 1.5/2 Ton out door unit single ended or double ended shaft as per existing one complete all as specified and directed.
Removing the unserviceable compressor from split type AC and supply and fix new compressor suitable for 1.5 Ton split type AC all including fixing in original position, connecting up, testing, gas charging, pressure testing, cleaning, condensing and cooling coils, welding, bracing, also including required length of capacity tube, strainer/filter and painting of base plate complete all as per existing one and as directed by Engr-in-Charge.
All as per item No.06 above but suitable for 2 Ton split type AC complete all as specified and directed.
All as per item No.06 above but suitable for 3.5/4 Ton Tower AC complete all as specified and directed.
S&F in replacement of copper piping (suction line and discharge line) and power cable including the thermal insulation with white tape as per site requirement complete as directed by Engr in charge.
S&F drain pump suitable for cassette type split AC 2 TR including taking down the defective drain pump complete all as specified and directed by Engr in charge.
S&F in repair of indoor cooling coil made up of copper tubing and copper/ aluminium cooling fins all as per sample and as suitable for 1.5/2 Ton capacity split type AC complete all as specified and directed by Engr in charge.
S&F in repair condenser coil made up of copper tubing and copper/ aluminium cooling fins all as per sample and as suitable for 1.5/2 Ton capacity split type AC complete all as specified and directed by Engr in charge.
S&F in replacement of indoor cooling coil made up of copper tubing and copper/ aluminium cooling fins all as per sample and as suitable for 1.5/2 Ton capacity cassette type AC complete all as specified and directed by Engr in charge.
S&F in replacement of condenser coil made up of copper tubing and copper/ aluminium cooling fins all as per sample and as suitable for 1.5/2 Ton capacity cassette type AC complete all as specified and directed by Engr in charge.
S&F in replacement of indoor unit including outer body, fan motor, filter, copper cooling coil, blower, display, thermostat, sensor & PCB suitable for 1.5 TR split type AC unit including testing complete all as specified and directed by Engr in charge.
S&F in replacement of outdoor complete unit suitable for 1.5 TR split type AC (coil should be copper) without compressor complete all as specified and directed by Engr in charge.
S&F in replacement of room sensor all as per existing one and suitable for 1.5/2 Ton capacity split AC complete all as specified and directed by Engr in charge.
S&F in replacement of running capacitor 60 Mfd 440 V AC suitable for 1.5/2/4 Ton capacity AC complete all as specified and directed by Engr in charge.
S&F in replacement of capacitor 6 Mfd 440 Volts suitable for condenser motor of 1.5/2/4 Ton A/C capacity complete all as specified and directed by Engr in charge.
S&F in replacement of coil sensor all as per existing one and suitable for 1.5/2 Ton capacity split AC complete all as specified and directed by Engr in charge.
S&F in replacement of condensor fan blade all as per existing one and suitable for 1.5/2/4 Ton capacity split AC complete all as specified and directed by Engr in charge.
S&F in replacement sheet metal enclosure, single pole neutral, with two pin and earth plug top and socket complete with one no of MCB SP, 20 A, 240 V complete all as specified and directed by Engr in charge.
Tracing out leakage from suction line, discharge line, evaporation condenser, filter, capillary tube by suitable method including bracing, welding, replacement of filter strainer charging line and filling of gas, charging as prescribed by manufacturer, leak testing & commissioning of split type A/C of any type, any capacity, any make complete all as specified and directed by Engr in charge.
Tracing out leakage from suction line, discharge line, evaporation condenser, filter, capillary tube by suitable method including bracing, welding, replacement of filter strainer charging line and filling of gas, charging as prescribed by manufacturer, leak testing & commissioning of cassette type A/C of any type, any capacity, any make complete all as specified and directed by Engr in charge.
S&F in replacement of printed circuit board (PCB) complete set normal type (Indoor & Out Door Unit) including controlling unit (ie Remote) all as per existing one and suitable for 1.5/2 TR cassette type Split AC complete all as specified and directed by Engr in charge.
S&F in replacement of printed circuit board (PCB) complete set inverter type (Indoor & Out Door Unit) including controlling unit (ie Remote), Mother board all as per existing one and suitable for 1.5/2 TR Split AC complete all as specified and directed by Engr in charge.
M&L for repairing of printed circuit board (PCB) complete set inverter type (Indoor & Out Door Unit) including controlling unit (ie Remote) all as per existing one and suitable for 1.5/2 TR Split AC complete all as specified and directed by Engr in charge.
M&L for repairing to printed circuit board (PCB) complete set non inverter type (Indoor & Out Door Unit) including controlling unit (ie Remote) all as per existing one and suitable for 1.5/2 TR Split AC complete all as specified and directed by Engr in charge.
S&F in replacement of printed circuit board (PCB) complete set three phase (for Outdoor unit) including controlling unit (ie Remote) all as per existing one and suitable for floor standing AC complete all as specified and directed by Engr in charge.
S&F in replacement of indoor unit including outer body, fan motor, filter, copper cooling coil, blower, display, thermostat, sensor & PCB suitable for 2 TR split type AC unit including testing complete all as specified and directed by Engr in charge.
S&F in replacement of outdoor complete unit suitable for 2 TR split type AC including copper coil but without compressor complete all as specified and directed by Engr in charge.
S&F in replacement of voltage stabilizer 5 KVA suitable for window/ split type AC capacity upto 1.5/2TR complete all as specified and directed by Engr in charge.
S&F in replacement of voltage stabilizer 4 KVA suitable for window/ split type AC capacity upto 1.5/2TR complete all as specified and directed by Engr in charge.
S&F in replacement of voltage stabilizer 1 KVA suitable for water cooler complete all as specified and directed by Engr in charge.
M&L for clear guard copper preventive coating to protect corrosion of window/split type AC copper parts like cooling coil, condencing coil, copper piping etc complete all as specified and directed by Engr in charge.
S&F in replacement of remote universal type for window / split type AC as per matching existing complete all as specified and directed by Engr in charge.
Taking out/removing of split type AC complete indoor and outdoor unit from any height/ any floor of building including pumping down the gas into the compressor by controlling the suction and discharge valves, disconnecting the suction and discharge copper piping and shifting to another location in the same or other building in the complex and testing for functional of AC complete all as specified and directed by Engr in charge.
M&L for water leakage of water cooler of any capacity any make, cleaning of water tank, tightening of loose wire, nuts, bolts, washers, replacement of suitable pipes, testing after repair complete all as specified and directed by Engr in charge.
Supply and charging the gas refrigerant R-22 of window type AC/splite type AC upto 2 ton capacity including testing after application of nitrogen gas pressure to find out any leakage, brazing and stopping of all leakage detected, re-application of nitrogen pressure to ensure leak proof gas circulator system, flushing out the nitrogen gas etc complete all as specified and directed.
All as per item No.39 above but refrigerant gas R-32 complete all as specified and directed by Engr in charge.
All as per item No.39 above but refrigerant gas R-410A complete all as specified and directed by Engr in charge.
Removing the unserviceable condenser fan motor from the water cooler of 40/120 Ltr capacity and M&L for rewinding of condenser fan motor of capacity 1/30 or 1/32 HP 1350 RPM single phase, with super enamelled copper wire of existing gauge including replacement of gunmetal bush, cleaning, greasing and refixing of motor, connecting up all including testing and refixing complete all as specified and directed.
Removing unserviceable condenser fan motor from the water cooler of any capacity and supply and fix in replacement new condenser fan motor 230 V, 50 HZ as per sample existing suitable for 40/120 Ltr capacity storage type water cooler complete all as specified and directed by Engr in charge.
Removing the unserviceable compressor from water cooler and supply and fix new compressor suitable for 120 Ltr capacity of water cooler including fixing in original position, connecting up, testing, gas charging, pressure testing, cleaning of cooling coils, necessary welding/ brazing and including required capillary tube complete all as specified and directed by Engr in charge.
Removing the unserviceable compressor from water cooler and supply and fix new compressor suitable for 40 Ltr capacity of water cooler including fixing in original position, connecting up, testing, gas charging, pressure testing, cleaning of cooling coils, necessary welding/ brazing and including required capillary tube complete all as specified and directed by Engr in charge.
S&F in replacement starting relay for 40/120 Ltr capacity water cooler including over load protector assembly complete all as specified and directed by Engr in charge.
Tracing out leakage from suction line, discharge line, evaporation condenser, filter, capillary tube by suitable method including bracing, welding, replacement of filter strainer, charging line and filling of gas charging as prescribed by manufacturer, leak testing & commissioning for water cooler 40/120 Ltr storage capacity, any type, any make complete all as specified and directed by Engr in charge.
M&L for servicing and cleaning of the water cooler 40/80/120 Ltr capacity by removing dust with suitable method, cleaning of water tank, inlet and outlets including leak proofing/ repairing of storage tank, necessary repairs to wiring of the water cooler unit (i.e) internal wiring connections to compressor, condenser motor etc., supply and replacement of damaged hinges, nuts, bolts, clamps, washers, screws, tightening of loose parts, servicing of condenser motor by oiling, greasing, required welding/bracing to any part of the water cooler, repairs to chromium plated drain tray, replacement of worn out mounting rubber bushes of condenser motor/compressor, setting of thermostat, relay, knobs, checking for any leakages, scrap out rust and dust from body of water cooler complete all as specified and directed by Engr in charge.
M&L for cutting, removing the old rusted base angle iron frame and MS sheets not exc 0.30 m high of chasses cabinet and S&F angle iron and required MS sheet 2 mm thick suitable to the base of storage type water cooler body of 40/80/120 Ltr capacity all including cutting, welding, bending, shaping, grinding, drilling and making good, supply and fixing of nuts, bolts, washers as per requirement and painting of complete water cooler unit including compressor, condenser motor with one coat of red oxide primer and two coats of synthetic enamel paint as per existing colour complete all as specified and directed by Engr in charge.
S&F in replacement of running capacitor 36 Mfd, suitable for 120 Ltr capacity water cooler complete all as specified and directed by Engr in charge.
S&F in replacement of running capacitor 10 Mfd, suitable for 40 Ltr capacity water cooler complete all as specified and directed by Engr in charge.
S&F in replacement chromium plated push/lifting cock 15 mm made up of SS and suitable for 40/80/120 Ltr capacity storage type water cooler as per existing sample complete all as specified and directed by Engr in charge.
S&F in replacement of thermostat including knob, plate, screws suitable for 40/150 Ltr capacity water cooler complete all as specified and directed by Engr in charge.
S&F in replacement of PVC drain pipe approx 1.5 mtr long of 25 mm dia for water cooler complete with clamp, screws etc complete to drain water from drain tray of water cooler as per existing sample complete all as specified and directed by Engr in charge.
S&F in replacement of float valve with polythene PVC ball of 15 mm (1/2") bore size suitable for 40/120 Ltr capacity water coolers as per existing sample complete all as specified and directed by Engr in charge.
S&F in replacement prefilter candle of water purifier of existing type complete all as specified and directed by Engr in charge.
S&F in replacement prefilter housing of water purifier of existing type complete all as specified and directed by Engr in charge.
S&F in replacement of carbon filter of water purifier of existing type complete all as specified and directed by Engr in charge.
S&F in replacement of RO membrane filter complete kit of water purifier of existing type complete all as specified and directed by Engr in charge.
S&F in replacement of printed circuit board(PCB) for water purifier AG 200 complete all as specified and directed by Engr in charge.
S&F in replacement of UV+UF water purifier with purification capacity of minimum 15 ltr/hr complete with necessary arrangement for waste water after purification process complete all as specified and directed by Engr in charge.
S&F in replacement of flexible hose of water purifier which connects prefilter to water purifier as per site requirement including necessary washers, screws etc complete all as specified and directed by Engr in charge.
M&L for servicing and repair to voltage stabilizer of capacity 4KVA/ 5KVA of any type including checking the PCB control board, suitable 220/240V transformer, replacement of time delay relay, indicator lamps, socket combination 5/15 Amps, plug tops, cut outs to rectify the defects complete all as specified and directed by Engr in charge.
S&F in replacement of PCB for voltage stabilizer of capacity 5 KVA including taking down the unserviceable one complete all as specified and directed by Engr in charge.
S&F in replacement single phase 220/240 Volts transformer suitable for 4/5 KVA voltage stabilizer complete all as specified and directed by Engr in charge.
S&F in replacement of MCB TPN 415V, 10 kA, 63A capacity, C curve complete all as specified and directed by Engr in charge.
S&F in replacement of MCB SPN, 230V, 10 kA, 40A capacity, C curve complete all as specified and directed by Engr in charge.
M&L for sub main wiring using 2 runs of 4 Sq mm FR PVC insulated copper conductor 1100 Volts grade conforming to IS specification drawn through PVC conduit along with 1 run of 4 Sq mm PVC insulated copper conductor FR cable as earth lead connected to common earth dolly complete all as specified including taking down the unserviceable wiring complete all as specified and directed by Engr in charge. Notes:- (i) One run of PVC conduit alongwith 3 runs of 4 sqmm PVC insulated copper conductor cable with necessary accessories will be measured as one unit. (ii) Strictly follow the proper colour code red/yellow/blue for phase,black for neutral and green for earth. (iii) Necessary PVC rigid junction boxes for identifying junction as required on site/directed by Engr-in-charge for point wiring work with PVC dummy plates shall deemed to be included in the quoted rate.
S&F in replacement of AC outdoor stand for mounting of split type ACs complete all as specified and directed by Engr in charge.
M&L for taking down of ventilation motor 10/15 HP capacity at any height and dismantling the motor end covers, cutting and taking out of the burnt out stator windings complete and cleaning the slots, removing all dust / dirt etc rewinding with same guage super enamelled copper winding wire with insulating materials, varnishing, heating, replacement of bearing ends, refixing the same and ensure its servicability complete all as specified and directed by Engr in charge.
All as per item No.70 above but suitable for ventilation motor 5/7.5 HP capacity complete all as specified and directed by Engr in charge.
M&L for painting of ventilation system complete ducts outer surface with enamel paint through spray gun machine as per existing colour complete all as specified and directed by Engr in charge.
M&L for checking water leakage of split type AC/Floor standing AC/Cassette AC unit of any capacity any make by removing dust with suitable method, cleaning of air filters, tightening of loose wire, nuts, bolts, washers, replacement of suitable pipes complete, testing after repair complete all as specified and directed by Engr in charge.
S&F in replacement of auxiliary contactor single phase suitable for ACs complete all as specified and directed by Engr in charge.
S&F in replacement of auxiliary contactor three phase suitable for three phase ACs complete all as specified and directed by Engr in charge.
RASNA ENTERPRISES
Jack Electrolinks Private Limited
SREEKRUPA ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .