| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹98.4 LAccepted-AOC 309 SKYLARK BUILDING 309 SKYLARK BUILDING 60 NEHRU PLACE NEW DELHI NEW DELHI DELHI 110019 | SOUTH EAST DELHI | DELHI | 110019 | 1 | Accepted-AOC L1 bidder | |
| 2 | 2₹1.2 Cr+₹4.3 L (3.71%)Rejected-Finance 1ST FLOOR RZ 100J 182 OPPOSITE PILLAR NO 34 NR PALAM METRO GATE NO 2 RAJ NAGAR I PALAM NEW DELHI SOUTH WEST DELHI DELHI 110077 | SOUTH WEST DELHI | DELHI | 110077 | 2 | Rejected-Finance L2 | |
| 3 | Rejected-Technical U 110 FIRST FLOOR SAPNA ARORA U 110 1ST FLOOR SURYA ARCADE MAIN VIKAS MARG DELHI 110092 SHAKARPUR EAST DELHI DELHI 110092 | EAST DELHI | DELHI | 110092 | - | Rejected-Technical Technical bid NOT accepted by competent authority |
Tender Value
₹98.2 L
EMD Value
₹2.0 L
Closing Date
16 Mar 2023, 10:00 amClosed
Ex. Engineer (Elect)/CPSZ
OFFICE OF THE EX. ENGINEER (ELECT)-I UNDER GROUND CAR PARKING ASAF ALI ROAD, DELHI-110002
Const. of 200 Bedded Balak Ram Hospital at Timarpur Delhi. Sub-Head- Provision of UPS System.
2023_NDMC_148031_1
41/MWEEE-I/2022-23/TC Item no.1
Open Tender
Electrical Works
Item Rate
120 days
CSPZ
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,180
₹2.0 L
17 Feb 2024
6 Mar 2023
16 Mar 2023
6 Mar 2023
16 Mar 2023
6 Mar 2023
Amount
7.6.4:Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Above 185 sq. mm and upto 400 sq. mm
4.1.1:Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.100 mm width X 50 mm depth X 1.6 mm thickness
5.15:Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
9.1.29:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 240 sq. mm (62mm)
2.18:Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth,metal enclosed plug top along with 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
2.10.1:Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
OD3841/2022-2023:Supply of XLPE insulated and PVC Sheathed Al conductor armoured cable 1.1 KV grade conforming to IS-7098 (P-I) as required. 3½ X 240 sq. mm
OD3842/2022-2023:UPS INCOMING LT PANEL Fabrication, supplying, installation, Testing & Commissioning of wall mounted electrical panel of cubical construction, of suitable size with 400 Amp 4 Pole Aluminium Bus Bar insulated with heat shrinkable PVC sleeve, fabricated out of 2mm.thick CRCA sheet for load bearing members & 1.6 mm thick CRCA sheet for non load bearing memebers, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, inter-connection, having following switchgears and accessories mounting and internal wiring, earth terminals, numbering etc. Complete in all respect, suitable for operation on 415 V, 3phase, with neutral 50 HZ. AC supply. Incomer Feeder 400 Amp,35 KA,TPN MCCB - 1No Indicating Light - 3Nos Dig. Ammeter 0-500 A - 1No Dig. Voltmeter 0-500 V - 1No Control MCB -As required CT 500/5A -3Nos Outgoing Feeder 250 Amp,35 KA, TPN MCCB - 2 Nos
OD3843/2022-2023:UPS OUTGOING PANEL Fabrication, supplying, installation, Testing & Commissioning of wall mounted electrical panel of cubical construction, of suitable size with 400 Amp 4 Pole Aluminium Bus Bar insulated with heat shrinkable PVC sleeve, fabricated out of 2mm. thick CRCA sheet for load bearing members & 1.6 mm thick CRCA sheet for non load bearing memebers,compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, inter-connection, having following switchgears and accessories mounting and internal wiring, earth terminals, numbering etc. Complete in all respect, suitable for operation on 415 v, 3phase, with neutral 50 HZ. AC supply. Incomer Feeder 1, 400 Amp FP Change Over Switch -1No, Outgoing Feeder, 400 Amp,35KA TPN MCCB -2Nos, Indicating Light - 6Nos, Dig. Ammeter 0-500A -1No , Dig. Voltmeter 0-500V -1No, Control MCB - As required, CT 500/5A -3Nos,
OD3844/2022-2023:S/I/T/C of 200KVA rating online UPS with Battery with following specifications:- (i) Rating in KVA - 200KVA. (ii) Switching Technology - IGBT-PWM (iii) Input Voltage - AC Three phase (300-450V, 50Hz) (iv) Output Voltage - AC Three phase (Variable setting from 380V - 415Volt) (v) Warranty for UPS and Battery - 2 years (vi) Type of Battery - SMF-VRLA (vii) Backup Time - 30 Minutes (viii) Isolation Transformer - In-Built/External (ix) Installation and Commissioning - With (x) Paralleling Kit for Hot standby - With (xi) Accessories - Rack for Batteries, Cabling 6 meters (input upto 3 m and output upto 3m)
OD3845/2022-2023:S&F Copper pipe size 5/8, 1/4 for spilt AC
OD3846/2022-2023:S&L 4 core 2.5sqmm insulated copper wire for Spilt AC
OD3847/2022-2023:SITC of Split Air Conditioner of 2TR capacity BEE 5star inverter technology, copper coil, including installaion, stand for outdoor unit etc. complete as reqd.
OD3848/2022-2023:S&F PVC Drain Pipe 25mm size
AALFA eNETWORK PVT LTD
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .