Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹19.6 Cr
EMD Value
₹5 L
Closing Date
30 Dec 2025, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SUPERINTENDING ENGINEER
SUPERINTENDING ENGINEER PH CIRCLE,KWA, ALAPPUZHA
Jal Jeevan Mission JJM Zone I CWSS to Haripad and adjoining Panchayaths Construction of 6LL OHSR at Cheppad 7LL OHSR at Pathiyoor Supplying and Laying of Transmission Main from WTP Pallippadu to Cheppad and Pathiyoor OHSR General Civil Work
2025_KWA_799785_1
10/2025-26/SE/PHC/ALP-RT-8
Open Tender
Civil Works - Water Works
Item Wise
365 days
Haripad
Please refer Tender documents.
8 documents required · 8 mandatory
₹19,518
Yes
₹5 L
Yes
PH CIRCLE,KWA, ALAPPUZHA
20 Sept 2025
20 Sept 2025
31 Dec 2025
20 Sept 2025
30 Dec 2025
20 Sept 2025
20 Sept 2025 - 5 Oct 2025
3 Oct 2025
Work Name:Jal Jeevan Mission (JJM)-Zone-I-CWSS to Haripad and adjoining Panchayaths-Construction of 6LL OHSR at Cheppad,7LL OHSR at Pathiyoor,Supplying and Laying of Transmission Main from WTP Pallippadu to Cheppad and Pathiyoor OHSR.-Zone-I-CWSS to Haripad and adjoining Panchayaths-Construction of 6LL OHSR at Cheppad,7LL OHSR at Pathiyoor,Supplying and Laying of Transmission Main from WTP Pallippadu to Cheppad and Pathiyoor OHSR.-General Civil Work
cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.80 mm thick C.C. paver block of M-30 grade with approved color design and pattern.å4.1.4:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 )1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) 5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal sizeí5.9.15:Centering and shuttering including strutting, etc. and removal of form for:Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the likeÎ5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or morekilogram/OD169317/2023-2024:Constructing valve chamber of inner size 1 .00m x1.00 m x 1.10m in M-25 grade cement concrete for reinforced cement concrete work and 10 mm MS rod(115 Kg) for foundation,side wall and cover slab (Plat form 1.30 mx1.30mx0.2 m,side wall 15 cm thick, cover slab 2 nos. of size 1.30x0.65x0.20m over a PCC base of size 1.50mx1.50mx0.15 m in 1:3:6 using 40 mm broken stone plastering inside the valve chamber and cover slab in CM.1:3, 6 mm thick including cost and conveyance of all materials etc.complete. as per the direction of deptl officers.6OD169318/2023-2024:Constructing valve chamber of inner size 1 .50m x 1.50 m x1.50m in M-25 grade cement concrete for reinforced cement concrete work and 10 mm MS rod(330 Kg) for foundation,side wall and cover slab(Plat form 1.80 mx1.80mx0.15 m,side wall 15 cm thick, cover slab 3 nos. of size 1.80mx0.60mx0.20m over a PCC base of size 1.80mx1.80mx0.15m in cm 1:3:6 using 40 mm broken stone,plastering inside the valve chamber and cover slab in CM.1:3, 6 mm thick including cost and conveyance of all materials etc.complete. as per the direction of deptl officers 1 nos100.46.3.2:Repairing leakage/breakage of 100mm A.C. pipeline by cutting and dismantling the damaged pipe portion (above 3.0m up to 5.0m) including charges for earthwork excavation in all kinds of soil including tar / concrete cutting for exposing leak portion of the pipe, operating control valves if any, conveying to the site and cutting new A.C. pipe to the required length, re-jointing the pipeline using C.I.D. Joints, testing the pipeline by operating the valves concerned, and rectifying the defects any noticed and without causing any damages to the existing utilities and refilling the trenches using excavated earth in layers not exceeding 20cm depth including consolidating each layers by ramming, watering, charges for removing surplus soil from work site, including hire for tools and plant, conveyance of tools and materials, bailing out water, providing caution boards, lighting, watching, ribbon fencing, traffic controlling etc., complete as per the direction of Departmental officers excluding the cost of pipe and C.I.D. Joints.x100.47.1.4:Leak rectification work in 63mm uPVC (Class 2 to 6) pipeline including detecting and locating leak, earthwork excavation in all kinds of soil for exposing leak portion of the pipe including tar cutting / concrete cutting, cutting the pipe diametrically perpendicular to the axis of pipeline without causing any damages to the remaining portion, dismantling and lifting the pipe from trenches, smoothening the cut ends, conveying the new pipe to the site, cutting and lowering new pipe into the trenches, placing in position, aligning the pipe to line and level and jointing the new pipe with the existing pipe with solvent cement or any available joint and testing the pipeline by operating the valves concerned, and rectifying the defects if noticed and without causing any damages to the existing utilities and refilling the trenches using excavated earth in layers not exceeding 20cm depth including consolidating each layers by ramming, watering, charges for removing surplus soil from work site, including hire for tools and plant, conveyance of tools and materials, bailing out water, providing caution boards, lighting, watching, ribbon fencing, traffic controlling etc., complete as per the direction of Departmental officers including the cost of pipe and uPVC specials; uPVC Pipes and specials shall be of good quality and conforming to relevant standards: All Socketed Jointing.x100.47.1.5:Leak rectification work in 75mm uPVC (Class 2 to 6) pipeline including detecting and locating leak, earthwork excavation in all kinds of soil for exposing leak portion of the pipe including tar cutting / concrete cutting, cutting the pipe diametrically perpendicular to the axis of pipeline without causing any damages to the remaining portion, dismantling and lifting the pipe from trenches, smoothening the cut ends, conveying the new pipe to the site, cutting and lowering new pipe into the trenches, placing in position, aligning the pipe to line and level and jointing the new pipe with the existing pipe with solvent cement or any available joint and testing the pipeline by operating the valves concerned, and rectifying the defects if noticed and without causing any damages to the existing utilities and refilling the trenches using excavated earth in layers not exceeding 20cm depth including consolidating each layers by ramming, watering, charges for removing surplus soil from work site, including hire for tools and plant, conveyance of tools and materials, bailing out water, providing caution boards, lighting, watching, ribbon fencing, traffic controlling etc., complete as per the direction of Departmental officers including the cost of pipe and uPVC specials; uPVC Pipes and specials shall be of good quality and conforming to relevant standards: All Socketed Jointing.p100.47.2.1:Leak rectification work in 90mm uPVC (Class 2 to 6) pipeline including detecting and locating leak, earth work excavation in all kinds of soil for exposing leak portion of the pipe including tar cutting / concrete cutting, cutting the pipe diametrically perpendicular to the axis of pipeline without causing any damages to the balance portion, dismantling and lifting the pipe from trenches, smoothening the cut ends, conveying the new pipe, cutting and lowering new pipe into the trenches, placing in position, aligning the pipe to line and level and jointing the new pipe with the existing pipe with solvent cement or repairable joint and testing the pipeline by operating the valves concerned, and rectifying the defects if noticed and refilling the trenches in layers not exceeding 20cm depth including consolidating each layers by ramming, watering, charges for removing surplus soil from work si
iver-Cost of MaterialsK100.98.146:Supply of HDPE Pipe PE 100 (IS 4984/1995), 8kg, 400mm Outer Dia.AOD169322/2023-2024:Specials for HDPE pipe 3 % of the cost of pipeL.S.Appendix C-Road restoration works in PWD Roads83.6:Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, and transporting to the embankment location within all lifts and lead upto 1000md4.1.A.1:Construction of granular sub-base by providing graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with a motor grader on the prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401 Grading-I - Plant Mix Method~4.12:Providing, laying, spreading and compacting graded stone aggregate to Wet Mix Macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density.Ù5.1.a:Providing and applying primer coat with bitumen emulsion ( SS) on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 0.70 - 1.0 kg/sqm using mechanical means.Í5.2.a:Providing and applying tack coat with bitumen emulsion( RS) using emulsion pressure distributor at the rate of 0.20 - 0.30 kg per sqm on the prepared bituminous surface cleaned with mechanical broom.Ë5.3.2.a:Providing and laying bituminous macadam with 80-100 TPH hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading premixed with a bituminous binder (VG 30), transported to the site, laid over a previously prepared surface with paver finisher to the required grade, level, and alignment and rolled as per clauses 501.6 and 501.7 to achieve the desired compaction For Grading II - (19 mm nominal size)P5.6.1.a:Providing and laying bituminous concrete with 80-100 TPH hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with a bituminous binder( NRMB) @ 5.2 percent of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level, and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORTH specification clause No. 507 complete in all respects For Grading - I ( 19 mm nominal size )>8.13:Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads on Bituminous Surface @ 250 gms per sqm area, the thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35. The finished surface to be level, uniform, and free from streaks and holes.18.35:Providing and fixing reflective road studs (Raised Pavement Marker) of ' category A' made out of ASA/HIPS/ABS moulded body with shanks and conforming to ASTM D 4280, strong enough to support a load of more than 13.635 T when tested in accordance with ASTM D 4280, reflective panel confirming to ASTM D 788, and reflectivity conforming to clause 804.4. including installation, drilling, fixing with adhesive etc. with 2 years warranty for the road stud as well as for in field performance as per clause 804.7.3 Road Markers/Road Stud with Lense Reflector :-'Appendix D-LSGD Road Restoration works Á3.5.3:Excavation in Soil using Hydraulic Excavator and Tippers with disposal upto 1000 m Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross-sections, and transporting to the embankment location with a lift upto 1.5 m and lead upto 1000 m as per Technical Specification Clause 302.3³4.1.A.1:Granular Sub-base with Well Graded Material (Table 400.1) (A) By Mix in Place Method Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. (i) For Grading I MaterialO4.9:Wet Mix Macadam Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mixer (Pug Mill), carriage of mixed material by tipper to site, laying in uniform layers in sub-base/base course on a well prepared sub-base and compacting with smooth wheel roller of 80 to 100kN weight to achieve the desired density including lighting, barricading and maintenance of diversion, etc as per Tables 400.11 & 400.12 and Technical Specification Clause 406. By Mechanical Means with 1 km lead5.1.1a:Prime Coat :- Low porosity Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 5025.2.3a:Tack Coat Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared granular surfaces treated with primer & cleaned with Hydraulic broom as per Technical Specification Clause 503.¯5.9.1.2a:20mm thick Open-Graded Premix Carpet using Bituminous (penetration grade/modified bitumen) Binder - Bitumen S-65 Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508. Case - I By Manual Means (II) Bitumen (S-65)C5.12.A.3.2a:Seal Coat - Manual Means - Type C - Bitumen S-65 Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C as per Technical Specification Clause 510 A. By Manual Means :- Case - III : Type C (II) Bitumen (S-65).Appendix E-Construction of 6LL OHSR at Cheppad2.31:Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area clearedDOD169293/2023-2024: Conducting soil investigation work for OHSR sitei20.2.5:Boring, providing and installing bored cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring, with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete, including removal of excavated earth with all lifts and leads (Length of pile for payment shall be measured upto bottom of pile cap).600 mm dia pilesi20.2.6:Boring, providing and installing bored cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring, with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all compl
required, will be paid separately): 200mm diameter, Class I.ë100.31.1.6:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 250mm diameter, Class I.ì100.31.1.11:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 500mm diameter, Class I.|100.98.467:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 500mm.|100.98.461:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 200mm.100.41.33:Supplying and fixing 500mm dia C.I. manhole cover with frame (medium duty) charges including all cost, labour charges etc., complete. /OD190188/2023-2024:Constructing valve chamber of inner size 1 .00m x1.00 m x 1.10m in M-25 grade cement concrete for reinforced cement concrete work and 10 mm MS rod(115 Kg) for foundation,side wall and cover slab (Plat form 1.30 mx1.30mx0.2 m,side wall 15 cm thick, cover slab 2 nos. of size 1.30x0.65x0.20m over a PCC base of size 1.50mx1.50mx0.15 m in 1:3:6 using 40 mm broken stone plastering inside the valve chamber and cover slab in CM.1:3, 6 mm thick including cost and conveyance of all materials etc.complete. as per the direction of deptl officers.2OD169296/2023-2024:Constructing valve chamber of inner size 1.50 m x1.50 m x1.50m in M-25 grade cement concrete for reinforced cement concrete work and 10 mm MS rod(330 Kg) for foundation,side wall and cover slab(Plat form 1.80 mx1.80 mx0.15 m,side wall15 cm thick,cover slab 2Nos of size 1.80 mx0.60 m x 0.20 m)over a PCC base of size 2.00mx2.00mx0.15 m in 1:3:6 using 40 mm broken stone,plastering inside the valve chamber and cover slab in CM.1:3, 6 mm thick including cost and conveyance of all materials etc.complete. as per the direction of deptl officers.Ù13.52.1:Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work8OD169297/2023-2024:Supplying and fixing an electro magnetic flow meter conforming to protection level of IP-68 for Flow Sensor and IP-67 for transmitter and having an accuracy level of 0.5% with LED/LCD disply unit. The flow meter should have the housing (flow sensor) to be made of SS 304/ carbon steel with anti corrosive protection and inside liner to be made up of hard rubber/ neoprene all conforming to drinking water standards. The flow meter should be coupled with HART for data acquisition and transfer, with provision for wireless transfer through GSM. The manufacturers should have the calibration standards as per ISO 17025 and the product shall have sufficient warranty provisions - 250 mm size inclusive of cost of flow meter, specials for connecting with 250mm DI pipes etc-Rate as per TC No. dtd 05/09/2012 G13.71:Lettering with black Japan pint of approved brand and manufactureper Letter per cm heightG100.36.1:Filling water with 5000 litre tankers fited in lorry and conveying water from a distance of 5 km (average) to the reservoir site and pumping the water into the reservoir of height not less than 3 m using 5 HP diesel engine pump set , hire for tanker lorry, tools and other appliences and cost of water etc. complete. ï2.25:Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.#50.2.25.1:Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge50.6.2.2:Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc completeOD169298/2023-2024:Providing and fixing design, manufacture, testing at manufacturer's Works, packing, supply, delivery of 42 KV & 12 KV classes of gapless Lightning Arrestors complete with fittings and accessories.1.2.These arrestors shall be of Heavy Duty, Station Class / Distribution Class and Gapless Zinc Oxide type.1.3.Arrestors shall be hermetically sealed units suitable for outdoor installation on self-supportin Lightning Arrestors shall be capable of discharging Lightning and switching surges and temporary power frequency over voltages .The Surge Arrestor shall be capable of discharging over voltages occurring during switching of unloaded transformers and long lines.The Arrestors shall be capable of withstanding Maximum Continuous Operating Voltages (M.C.O.VïOD169299/2023-2024:Electrification of OHSR compound with 25mts of wiring, 7nos of electric points including 2nosplug points, 1 no meter box, 1 no Distribution box for lights, 1 no Electric Fan of 1200mm dia, 4 nos of 10W LED light etc. [email protected]:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)150.9.1.1:Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately), using good quality Anjili wood /jack woodn50.9.3.1:Providing and fixing paneled or paneled and glazed shutters for doors, windows and clerestory windows, 30 mm thick shutters including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding paneling which will be paid for separately, all complete as per direction 0f Engineer in- charge. using Anjili/ Jack wood_50.9.4.1:Providing and fixing paneling or paneling and glazing in paneled or paneled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured) paneling for paneled or paneled and glazed shutters 25 mm to 40 mm thick using good quality Anjili/ Jack wood50.9.6.1:Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. Using Anjili wood / jack wood 30 mm thick shutters11.41.2:Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cemen
ass I./OD190207/2023-2024:Constructing valve chamber of inner size 1 .00m x1.00 m x 1.10m in M-25 grade cement concrete for reinforced cement concrete work and 10 mm MS rod(115 Kg) for foundation,side wall and cover slab (Plat form 1.30 mx1.30mx0.2 m,side wall 15 cm thick, cover slab 2 nos. of size 1.30x0.65x0.20m over a PCC base of size 1.50mx1.50mx0.15 m in 1:3:6 using 40 mm broken stone plastering inside the valve chamber and cover slab in CM.1:3, 6 mm thick including cost and conveyance of all materials etc.complete. as per the direction of deptl officers.2OD169307/2023-2024:Constructing valve chamber of inner size 1.50 m x1.50 m x1.50m in M-25 grade cement concrete for reinforced cement concrete work and 10 mm MS rod(330 Kg) for foundation,side wall and cover slab(Plat form 1.80 mx1.80 mx0.15 m,side wall15 cm thick,cover slab 2Nos of size 1.80 mx0.60 m x 0.20 m)over a PCC base of size 2.00mx2.00mx0.15 m in 1:3:6 using 40 mm broken stone,plastering inside the valve chamber and cover slab in CM.1:3, 6 mm thick including cost and conveyance of all materials etc.complete. as per the direction of deptl officers.5OD169308/2023-2024:Supplying and fixing an electro magnetic flow meter conforming to protection level of IP-68 for Flow Sensor and IP-67 for transmitter and having an accuracy level of 0.5% with LED/LCD disply unit. The flow meter should have the housing (flow sensor) to be made of SS 304/ carbon steel with anti corrosive protection and inside liner to be made up of hard rubber/ neoprene all conforming to drinking water standards. The flow meter should be coupled with HART for data acquisition and transfer, with provision for wireless transfer through GSM. The manufacturers should have the calibration standards as per ISO 17025 and the product shall have sufficient warranty provisions - 250mm size inclusive of cost of flow meter, specials for connecting with 250mm DI pipes etc-Rate as per TC No. dtd 05/09/2012OD169309/2023-2024:Providing and fixing design, manufacture, testing at manufacturer's Works, packing, supply, delivery of 42 KV & 12 KV classes of gapless Lightning Arrestors complete with fittings and accessories.1.2.These arrestors shall be of Heavy Duty, Station Class / Distribution Class and Gapless Zinc Oxide type.1.3.Arrestors shall be hermetically sealed units suitable for outdoor installation on self-supportin Lightning Arrestors shall be capable of discharging Lightning and switching surges and temporary power frequency over voltages .The Surge Arrestor shall be capable of discharging over voltages occurring during switching of unloaded transformers and long lines.The Arrestors shall be capable of withstanding Maximum Continuous Operating Voltages (M.C.O.VïOD169310/2023-2024:Electrification of OHSR compound with 25mts of wiring, 7nos of electric points including 2nosplug points, 1 no meter box, 1 no Distribution box for lights, 1 no Electric Fan of 1200mm dia, 4 nos of 10W LED light etc. etc50.6.1.2:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete.11.41.1:Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 500x500 mm.oOD169311/2023-2024:Supplying and errecting of ferrocement septic tank ,1.65Mx1.00mx1.1m size including soak pitãOD170350/2023-2024:Carriage of surplus excavated soil and debris of BT/CC surface to stack yard and stacking within a radius of 5km as directed by departmental officers, hire charges of tools & plants and labour charges etc9Appendix G-Construction of Compound wall for Cheppad OHSR 5.1.3:Pro
required, will be paid separately): 200mm diameter, Class I.ë100.31.1.6:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 250mm diameter, Class I.ì100.31.1.11:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 500mm diameter, Class I.|100.98.467:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 500mm.|100.98.461:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 200mm.100.41.33:Supplying and fixing 500mm dia C.I. manhole cover with frame (medium duty) charges including all cost, labour charges etc., complete. /OD190188/2023-2024:Constructing valve chamber of inner size 1 .00m x1.00 m x 1.10m in M-25 grade cement concrete for reinforced cement concrete work and 10 mm MS rod(115 Kg) for foundation,side wall and cover slab (Plat form 1.30 mx1.30mx0.2 m,side wall 15 cm thick, cover slab 2 nos. of size 1.30x0.65x0.20m over a PCC base of size 1.50mx1.50mx0.15 m in 1:3:6 using 40 mm broken stone plastering inside the valve chamber and cover slab in CM.1:3, 6 mm thick including cost and conveyance of all materials etc.complete. as per the direction of deptl officers.2OD169296/2023-2024:Constructing valve chamber of inner size 1.50 m x1.50 m x1.50m in M-25 grade cement concrete for reinforced cement concrete work and 10 mm MS rod(330 Kg) for foundation,side wall and cover slab(Plat form 1.80 mx1.80 mx0.15 m,side wall15 cm thick,cover slab 2Nos of size 1.80 mx0.60 m x 0.20 m)over a PCC base of size 2.00mx2.00mx0.15 m in 1:3:6 using 40 mm broken stone,plastering inside the valve chamber and cover slab in CM.1:3, 6 mm thick including cost and conveyance of all materials etc.complete. as per the direction of deptl officers.Ù13.52.1:Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work8OD169297/2023-2024:Supplying and fixing an electro magnetic flow meter conforming to protection level of IP-68 for Flow Sensor and IP-67 for transmitter and having an accuracy level of 0.5% with LED/LCD disply unit. The flow meter should have the housing (flow sensor) to be made of SS 304/ carbon steel with anti corrosive protection and inside liner to be made up of hard rubber/ neoprene all conforming to drinking water standards. The flow meter should be coupled with HART for data acquisition and transfer, with provision for wireless transfer through GSM. The manufacturers should have the calibration standards as per ISO 17025 and the product shall have sufficient warranty provisions - 250 mm size inclusive of cost of flow meter, specials for connecting with 250mm DI pipes etc-Rate as per TC No. dtd 05/09/2012 G13.71:Lettering with black Japan pint of approved brand and manufactureper Letter per cm heightG100.36.1:Filling water with 5000 litre tankers fited in lorry and conveying water from a distance of 5 km (average) to the reservoir site and pumping the water into the reservoir of height not less than 3 m using 5 HP diesel engine pump set , hire for tanker lorry, tools and other appliences and cost of water etc. complete. ï2.25:Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.#50.2.25.1:Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge50.6.2.2:Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc completeOD169298/2023-2024:Providing and fixing design, manufacture, testing at manufacturer's Works, packing, supply, delivery of 42 KV & 12 KV classes of gapless Lightning Arrestors complete with fittings and accessories.1.2.These arrestors shall be of Heavy Duty, Station Class / Distribution Class and Gapless Zinc Oxide type.1.3.Arrestors shall be hermetically sealed units suitable for outdoor installation on self-supportin Lightning Arrestors shall be capable of discharging Lightning and switching surges and temporary power frequency over voltages .The Surge Arrestor shall be capable of discharging over voltages occurring during switching of unloaded transformers and long lines.The Arrestors shall be capable of withstanding Maximum Continuous Operating Voltages (M.C.O.VïOD169299/2023-2024:Electrification of OHSR compound with 25mts of wiring, 7nos of electric points including 2nosplug points, 1 no meter box, 1 no Distribution box for lights, 1 no Electric Fan of 1200mm dia, 4 nos of 10W LED light etc. [email protected]:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)150.9.1.1:Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately), using good quality Anjili wood /jack woodn50.9.3.1:Providing and fixing paneled or paneled and glazed shutters for doors, windows and clerestory windows, 30 mm thick shutters including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding paneling which will be paid for separately, all complete as per direction 0f Engineer in- charge. using Anjili/ Jack wood_50.9.4.1:Providing and fixing paneling or paneling and glazing in paneled or paneled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured) paneling for paneled or paneled and glazed shutters 25 mm to 40 mm thick using good quality Anjili/ Jack wood50.9.6.1:Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. Using Anjili wood / jack wood 30 mm thick shutters11.41.2:Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cemen
ass I./OD190207/2023-2024:Constructing valve chamber of inner size 1 .00m x1.00 m x 1.10m in M-25 grade cement concrete for reinforced cement concrete work and 10 mm MS rod(115 Kg) for foundation,side wall and cover slab (Plat form 1.30 mx1.30mx0.2 m,side wall 15 cm thick, cover slab 2 nos. of size 1.30x0.65x0.20m over a PCC base of size 1.50mx1.50mx0.15 m in 1:3:6 using 40 mm broken stone plastering inside the valve chamber and cover slab in CM.1:3, 6 mm thick including cost and conveyance of all materials etc.complete. as per the direction of deptl officers.2OD169307/2023-2024:Constructing valve chamber of inner size 1.50 m x1.50 m x1.50m in M-25 grade cement concrete for reinforced cement concrete work and 10 mm MS rod(330 Kg) for foundation,side wall and cover slab(Plat form 1.80 mx1.80 mx0.15 m,side wall15 cm thick,cover slab 2Nos of size 1.80 mx0.60 m x 0.20 m)over a PCC base of size 2.00mx2.00mx0.15 m in 1:3:6 using 40 mm broken stone,plastering inside the valve chamber and cover slab in CM.1:3, 6 mm thick including cost and conveyance of all materials etc.complete. as per the direction of deptl officers.5OD169308/2023-2024:Supplying and fixing an electro magnetic flow meter conforming to protection level of IP-68 for Flow Sensor and IP-67 for transmitter and having an accuracy level of 0.5% with LED/LCD disply unit. The flow meter should have the housing (flow sensor) to be made of SS 304/ carbon steel with anti corrosive protection and inside liner to be made up of hard rubber/ neoprene all conforming to drinking water standards. The flow meter should be coupled with HART for data acquisition and transfer, with provision for wireless transfer through GSM. The manufacturers should have the calibration standards as per ISO 17025 and the product shall have sufficient warranty provisions - 250mm size inclusive of cost of flow meter, specials for connecting with 250mm DI pipes etc-Rate as per TC No. dtd 05/09/2012OD169309/2023-2024:Providing and fixing design, manufacture, testing at manufacturer's Works, packing, supply, delivery of 42 KV & 12 KV classes of gapless Lightning Arrestors complete with fittings and accessories.1.2.These arrestors shall be of Heavy Duty, Station Class / Distribution Class and Gapless Zinc Oxide type.1.3.Arrestors shall be hermetically sealed units suitable for outdoor installation on self-supportin Lightning Arrestors shall be capable of discharging Lightning and switching surges and temporary power frequency over voltages .The Surge Arrestor shall be capable of discharging over voltages occurring during switching of unloaded transformers and long lines.The Arrestors shall be capable of withstanding Maximum Continuous Operating Voltages (M.C.O.VïOD169310/2023-2024:Electrification of OHSR compound with 25mts of wiring, 7nos of electric points including 2nosplug points, 1 no meter box, 1 no Distribution box for lights, 1 no Electric Fan of 1200mm dia, 4 nos of 10W LED light etc. etc50.6.1.2:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete.11.41.1:Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 500x500 mm.oOD169311/2023-2024:Supplying and errecting of ferrocement septic tank ,1.65Mx1.00mx1.1m size including soak pitãOD170350/2023-2024:Carriage of surplus excavated soil and debris of BT/CC surface to stack yard and stacking within a radius of 5km as directed by departmental officers, hire charges of tools & plants and labour charges etc9Appendix G-Construction of Compound wall for Cheppad OHSR 5.1.3:Pro
iver-Cost of MaterialsK100.98.146:Supply of HDPE Pipe PE 100 (IS 4984/1995), 8kg, 400mm Outer Dia.AOD169322/2023-2024:Specials for HDPE pipe 3 % of the cost of pipeL.S.Appendix C-Road restoration works in PWD Roads83.6:Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, and transporting to the embankment location within all lifts and lead upto 1000md4.1.A.1:Construction of granular sub-base by providing graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with a motor grader on the prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401 Grading-I - Plant Mix Method~4.12:Providing, laying, spreading and compacting graded stone aggregate to Wet Mix Macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density.Ù5.1.a:Providing and applying primer coat with bitumen emulsion ( SS) on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 0.70 - 1.0 kg/sqm using mechanical means.Í5.2.a:Providing and applying tack coat with bitumen emulsion( RS) using emulsion pressure distributor at the rate of 0.20 - 0.30 kg per sqm on the prepared bituminous surface cleaned with mechanical broom.Ë5.3.2.a:Providing and laying bituminous macadam with 80-100 TPH hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading premixed with a bituminous binder (VG 30), transported to the site, laid over a previously prepared surface with paver finisher to the required grade, level, and alignment and rolled as per clauses 501.6 and 501.7 to achieve the desired compaction For Grading II - (19 mm nominal size)P5.6.1.a:Providing and laying bituminous concrete with 80-100 TPH hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with a bituminous binder( NRMB) @ 5.2 percent of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level, and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORTH specification clause No. 507 complete in all respects For Grading - I ( 19 mm nominal size )>8.13:Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads on Bituminous Surface @ 250 gms per sqm area, the thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35. The finished surface to be level, uniform, and free from streaks and holes.18.35:Providing and fixing reflective road studs (Raised Pavement Marker) of ' category A' made out of ASA/HIPS/ABS moulded body with shanks and conforming to ASTM D 4280, strong enough to support a load of more than 13.635 T when tested in accordance with ASTM D 4280, reflective panel confirming to ASTM D 788, and reflectivity conforming to clause 804.4. including installation, drilling, fixing with adhesive etc. with 2 years warranty for the road stud as well as for in field performance as per clause 804.7.3 Road Markers/Road Stud with Lense Reflector :-'Appendix D-LSGD Road Restoration works Á3.5.3:Excavation in Soil using Hydraulic Excavator and Tippers with disposal upto 1000 m Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross-sections, and transporting to the embankment location with a lift upto 1.5 m and lead upto 1000 m as per Technical Specification Clause 302.3³4.1.A.1:Granular Sub-base with Well Graded Material (Table 400.1) (A) By Mix in Place Method Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. (i) For Grading I MaterialO4.9:Wet Mix Macadam Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mixer (Pug Mill), carriage of mixed material by tipper to site, laying in uniform layers in sub-base/base course on a well prepared sub-base and compacting with smooth wheel roller of 80 to 100kN weight to achieve the desired density including lighting, barricading and maintenance of diversion, etc as per Tables 400.11 & 400.12 and Technical Specification Clause 406. By Mechanical Means with 1 km lead5.1.1a:Prime Coat :- Low porosity Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 5025.2.3a:Tack Coat Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared granular surfaces treated with primer & cleaned with Hydraulic broom as per Technical Specification Clause 503.¯5.9.1.2a:20mm thick Open-Graded Premix Carpet using Bituminous (penetration grade/modified bitumen) Binder - Bitumen S-65 Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508. Case - I By Manual Means (II) Bitumen (S-65)C5.12.A.3.2a:Seal Coat - Manual Means - Type C - Bitumen S-65 Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C as per Technical Specification Clause 510 A. By Manual Means :- Case - III : Type C (II) Bitumen (S-65).Appendix E-Construction of 6LL OHSR at Cheppad2.31:Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area clearedDOD169293/2023-2024: Conducting soil investigation work for OHSR sitei20.2.5:Boring, providing and installing bored cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring, with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete, including removal of excavated earth with all lifts and leads (Length of pile for payment shall be measured upto bottom of pile cap).600 mm dia pilesi20.2.6:Boring, providing and installing bored cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring, with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all compl
ass I./OD190207/2023-2024:Constructing valve chamber of inner size 1 .00m x1.00 m x 1.10m in M-25 grade cement concrete for reinforced cement concrete work and 10 mm MS rod(115 Kg) for foundation,side wall and cover slab (Plat form 1.30 mx1.30mx0.2 m,side wall 15 cm thick, cover slab 2 nos. of size 1.30x0.65x0.20m over a PCC base of size 1.50mx1.50mx0.15 m in 1:3:6 using 40 mm broken stone plastering inside the valve chamber and cover slab in CM.1:3, 6 mm thick including cost and conveyance of all materials etc.complete. as per the direction of deptl officers.2OD169307/2023-2024:Constructing valve chamber of inner size 1.50 m x1.50 m x1.50m in M-25 grade cement concrete for reinforced cement concrete work and 10 mm MS rod(330 Kg) for foundation,side wall and cover slab(Plat form 1.80 mx1.80 mx0.15 m,side wall15 cm thick,cover slab 2Nos of size 1.80 mx0.60 m x 0.20 m)over a PCC base of size 2.00mx2.00mx0.15 m in 1:3:6 using 40 mm broken stone,plastering inside the valve chamber and cover slab in CM.1:3, 6 mm thick including cost and conveyance of all materials etc.complete. as per the direction of deptl officers.5OD169308/2023-2024:Supplying and fixing an electro magnetic flow meter conforming to protection level of IP-68 for Flow Sensor and IP-67 for transmitter and having an accuracy level of 0.5% with LED/LCD disply unit. The flow meter should have the housing (flow sensor) to be made of SS 304/ carbon steel with anti corrosive protection and inside liner to be made up of hard rubber/ neoprene all conforming to drinking water standards. The flow meter should be coupled with HART for data acquisition and transfer, with provision for wireless transfer through GSM. The manufacturers should have the calibration standards as per ISO 17025 and the product shall have sufficient warranty provisions - 250mm size inclusive of cost of flow meter, specials for connecting with 250mm DI pipes etc-Rate as per TC No. dtd 05/09/2012OD169309/2023-2024:Providing and fixing design, manufacture, testing at manufacturer's Works, packing, supply, delivery of 42 KV & 12 KV classes of gapless Lightning Arrestors complete with fittings and accessories.1.2.These arrestors shall be of Heavy Duty, Station Class / Distribution Class and Gapless Zinc Oxide type.1.3.Arrestors shall be hermetically sealed units suitable for outdoor installation on self-supportin Lightning Arrestors shall be capable of discharging Lightning and switching surges and temporary power frequency over voltages .The Surge Arrestor shall be capable of discharging over voltages occurring during switching of unloaded transformers and long lines.The Arrestors shall be capable of withstanding Maximum Continuous Operating Voltages (M.C.O.VïOD169310/2023-2024:Electrification of OHSR compound with 25mts of wiring, 7nos of electric points including 2nosplug points, 1 no meter box, 1 no Distribution box for lights, 1 no Electric Fan of 1200mm dia, 4 nos of 10W LED light etc. etc50.6.1.2:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete.11.41.1:Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 500x500 mm.oOD169311/2023-2024:Supplying and errecting of ferrocement septic tank ,1.65Mx1.00mx1.1m size including soak pitãOD170350/2023-2024:Carriage of surplus excavated soil and debris of BT/CC surface to stack yard and stacking within a radius of 5km as directed by departmental officers, hire charges of tools & plants and labour charges etc9Appendix G-Construction of Compound wall for Cheppad OHSR 5.1.3:Pro
iver-Cost of MaterialsK100.98.146:Supply of HDPE Pipe PE 100 (IS 4984/1995), 8kg, 400mm Outer Dia.AOD169322/2023-2024:Specials for HDPE pipe 3 % of the cost of pipeL.S.Appendix C-Road restoration works in PWD Roads83.6:Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, and transporting to the embankment location within all lifts and lead upto 1000md4.1.A.1:Construction of granular sub-base by providing graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with a motor grader on the prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401 Grading-I - Plant Mix Method~4.12:Providing, laying, spreading and compacting graded stone aggregate to Wet Mix Macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density.Ù5.1.a:Providing and applying primer coat with bitumen emulsion ( SS) on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 0.70 - 1.0 kg/sqm using mechanical means.Í5.2.a:Providing and applying tack coat with bitumen emulsion( RS) using emulsion pressure distributor at the rate of 0.20 - 0.30 kg per sqm on the prepared bituminous surface cleaned with mechanical broom.Ë5.3.2.a:Providing and laying bituminous macadam with 80-100 TPH hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading premixed with a bituminous binder (VG 30), transported to the site, laid over a previously prepared surface with paver finisher to the required grade, level, and alignment and rolled as per clauses 501.6 and 501.7 to achieve the desired compaction For Grading II - (19 mm nominal size)P5.6.1.a:Providing and laying bituminous concrete with 80-100 TPH hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with a bituminous binder( NRMB) @ 5.2 percent of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level, and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORTH specification clause No. 507 complete in all respects For Grading - I ( 19 mm nominal size )>8.13:Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads on Bituminous Surface @ 250 gms per sqm area, the thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35. The finished surface to be level, uniform, and free from streaks and holes.18.35:Providing and fixing reflective road studs (Raised Pavement Marker) of ' category A' made out of ASA/HIPS/ABS moulded body with shanks and conforming to ASTM D 4280, strong enough to support a load of more than 13.635 T when tested in accordance with ASTM D 4280, reflective panel confirming to ASTM D 788, and reflectivity conforming to clause 804.4. including installation, drilling, fixing with adhesive etc. with 2 years warranty for the road stud as well as for in field performance as per clause 804.7.3 Road Markers/Road Stud with Lense Reflector :-'Appendix D-LSGD Road Restoration works Á3.5.3:Excavation in Soil using Hydraulic Excavator and Tippers with disposal upto 1000 m Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross-sections, and transporting to the embankment location with a lift upto 1.5 m and lead upto 1000 m as per Technical Specification Clause 302.3³4.1.A.1:Granular Sub-base with Well Graded Material (Table 400.1) (A) By Mix in Place Method Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. (i) For Grading I MaterialO4.9:Wet Mix Macadam Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mixer (Pug Mill), carriage of mixed material by tipper to site, laying in uniform layers in sub-base/base course on a well prepared sub-base and compacting with smooth wheel roller of 80 to 100kN weight to achieve the desired density including lighting, barricading and maintenance of diversion, etc as per Tables 400.11 & 400.12 and Technical Specification Clause 406. By Mechanical Means with 1 km lead5.1.1a:Prime Coat :- Low porosity Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 5025.2.3a:Tack Coat Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared granular surfaces treated with primer & cleaned with Hydraulic broom as per Technical Specification Clause 503.¯5.9.1.2a:20mm thick Open-Graded Premix Carpet using Bituminous (penetration grade/modified bitumen) Binder - Bitumen S-65 Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508. Case - I By Manual Means (II) Bitumen (S-65)C5.12.A.3.2a:Seal Coat - Manual Means - Type C - Bitumen S-65 Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C as per Technical Specification Clause 510 A. By Manual Means :- Case - III : Type C (II) Bitumen (S-65).Appendix E-Construction of 6LL OHSR at Cheppad2.31:Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area clearedDOD169293/2023-2024: Conducting soil investigation work for OHSR sitei20.2.5:Boring, providing and installing bored cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring, with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete, including removal of excavated earth with all lifts and leads (Length of pile for payment shall be measured upto bottom of pile cap).600 mm dia pilesi20.2.6:Boring, providing and installing bored cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring, with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all compl
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.06 MB
KWAGeneralConditionsforeTenderingV5.pdf
PDF • 0.69 MB
Tendernotice_1.pdf
PDF • 1.67 MB
ApprovedDWGCheppad.pdf
Tender Documents • 1.84 MB
ApprovedDWGPathiyoorOHSR.pdf
Tender Documents • 0.38 MB
DWGzone1.pdf
Tender Documents • 0.16 MB
SitePlanCheppadOHSR.pdf
Tender Documents • 0.05 MB
SchematicDiagram.pdf
Tender Documents • 0.30 MB
SitePlanPathiyoorOHSR.pdf
Tender Documents • 0.04 MB
SoilReportCheppad.pdf
Tender Documents • 0.82 MB
SoilReportPathiyoorOHSR.pdf
Tender Documents • 0.19 MB
JJMcircularsmerge.pdf
Other Document • 4.60 MB
CourtOrder.pdf
Other Document • 2.16 MB
GODLP5yrs.pdf
Additional Documents • 1.66 MB
NIT.pdf
Additional Documents • 1.12 MB
BOQ_1326406.xls
BOQ • 0.53 MB
Ext1.pdf
PDF • 0.10 MB
ClarificationPrebidCorrigendum.pdf
PDF • 0.40 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .