Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.4 LAccepted-AOC VILL KASHNI NEAR AANCHAL DAIRY PO BIN PITHORAGARH UTTARAKHAND PIN 262508 | PITHORAGARH | PITHORAGARH | UTTARAKHAND | 262508 | L1 | Accepted-AOC being L1 | |
| 2 | L2₹6.2 L+₹67,562 (12.3%)Rejected-Finance BHATT COLONY KAMALUWAGANJA ROAD HARIPUR NAYAK KUSUMKHERA HALDWANI DISTT NAINITAL UK | L2 | Rejected-Finance not being l1 | |
| 3 | L3₹6.6 L+₹1.1 L (19.6%)Rejected-Finance | L3 | Rejected-Finance Not being L1 |
Tender Value
Refer Docs
EMD Value
₹15,000
Closing Date
12 Oct 2020, 6:00 pmClosed
AGE I RnD haldwani
AGE I RnD haldwani po Arjunpur UK 263139
REPAIR / MAINT OF EXTERNAL WATER SUPPLY REPAIR OF PUMP MOTOR PIPE LINE AND OTHER MISC E/M WORK AT DIBER COMPLEX UNDER AGE I RnD HALDWANI
2020_MES_378316_1
AGE I RnD/HLD/19 OF 2020-2021
Open Tender
Civil Works
Item Rate
180 days
DIBER Haldwani
As per NIT
8 documents required · 8 mandatory
₹500
AGE I RnD haldwani
₹15,000
Yes
11 Dec 2020
17 Sept 2020
17 Oct 2020
17 Sept 2020
12 Oct 2020
30 Sept 2020
17 Sept 2020 - 30 Sept 2020
Amount
Contract Details
Inspection, tuning, callibration,connecting of cable, rewiring where required from controle panel to controle switchs and other equipment of auto functional system ,detection of fault and rectification, commisioning of main controle panel to make auto functional and testing of complete fire fighting system. Assement of serviceability of all connected equipement of fire fighting system compraising of pump set,motor,pressure tank ,pressure guage ,pressure valve electric controle panel,cable, fire hydrant,hose reel box, vertical duct, controle valves , hoses, rubber reels, syron and measurig equepements to the satisfaction of Eng- in- Charge at DIBER technical area . Minor item like cable upto 1.5 mtr, insulation tape ,marker , lugs ,separater if required will be supply and fixed by contractor, cost of the same is deemed to be included in the item of work.Notes : (i) Replacement of unserviceable parts if required shall be measured and paid for separately under appropriate item of Sch `A` here in after.(ii) Detail inspection/serviciability report will be submitted by the contractor cost of the same is deemed to be included in the item of work all as directed to the satisfaction of E in Charge .
M&L for repair of old existing out door double door hose box doors, locking system and replacement of both existing broken door glasses with existing size complete with rubber beading and denting/welding all as required at site and directed.
M&L for repair of old existing double door duct doors, locking system, hinges and replacement of both door glasses of existing size complete with rubber beading and denting/welding all as directed to the satisfaction of E in Charge
M&L fire hose box made out of MS sheet having thickness 18 gauge, double door, out door with glass pane, with locking arrengement of size L X W x D (800mm x 600mm x 250mm) fixed on two GI angle iron legs of existing size, duly painted with two coats sythatic enamelled red paint over a coat of red oxide primer and in side with white colour, including PCC foundation suitable for placing two nos of hose reel of size 15 mtr long and nozzel complete,including dismaintling of old existing one complete all as directed.
Disconnecting and taking out old existing unserviceable pressure switches supply & fix new Industrial Pressure switch for water of exesting size complete all as directed. Make Indfos cat IPS 100 or equivallent of Denfos
M & L for taking out old existing unserviceable water pressure guage supply & fix new water Pressure guage 4'' dia 0-14 kgs rating of complete all as directed. Make Indfos cat IPS 100or equivallent of Denfos
Disconnecting and taking out old existing unserviceable safety relief vave of size 25mm straight type screwed male end of brass/bronze made and supply & fix new safety release valve of size 25mm of brass/bronze complete with testing and as directed.
Disconnecting and taking out old existing unserviceable volt meter supply & fix new digital volt meter three phase bright LED display 4 digits square type complete with nut bolt and testing and commisioning all as directed. Make Schneider Cat 300462 and equvalent of other make
Disconnecting and taking out old existing unserviceable Amp meter and supply & fix new digital Amp meter three phase bright LED display 4 digits square type complete with nut bolt and testing and commisioning all as directed. Make Schneider Cat 300461and equivalent
Disconnecting and taking out old existing unserviceable volt meter supply & fix new anolog volt meter three phase bright 0 to 500 V, square type complete with nut bolt and testing and commisioning all as directed. Make AE and equvalent
Disconnecting and taking out old existing unserviceable Amp meter and supply & fix new anolog Amp meter three phase bright 0 to 250 A square type complete with nut bolt and testing and commisioning all as directed. Make AE or equivalent
Taking out existing defectiveCI butterfly valve of size 80 mm bore and supply & fix new CI butterfly valves of 80 mm bore incl replacement of rubber gasket, nut and bolt etc. all as directed.Make Kartar or equivallant
Taking out existing defectiveCI butterfly valve of size 100 mm bore and supply & fix new CI butterfly valves of 100 mm bore incl replacement of rubber gasket, nut and bolt etc. all as directed.Make Kartar or equivalant
Taking out existing defectiveCI butterfly valve of size 150 mm bore and supply & fix new CI butterfly valves of 150 mm bore incl replacement of rubber gasket, nut and bolt etc. all as directed.Make Kartar or equivalant
Taking out existing defectiveCI butterfly valve of size 200 mm bore and supply & fix new CI butterfly valves of 200 mm bore incl replacement of rubber gasket, nut and bolt etc. all as directed.Make Kartar or equivalant
Taking out existing defective GM gate valve of size 25 mm bore and supply & fix new GM brass gate valve of size 25 mm bore incl repair/rereplacement of required GI fitting and connected work all as direc ted.
Taking out existing defective GM gate valve of size 40 mm bore and supply & fix new GM gate valve of size 40 mm bore incl repair/rereplacement of required GI fitting and connected work all as direc ted.
Taking out existing defective GM gate valve of size 50 mm bore and supply & fix new GM gate valve of size 50 mm bore incl repair/rereplacement of required GI fitting and connected work all as direc ted.
Taking out existing defective GM gate valve of size 20 mm bore and supply & fix new GM gate valve of size 20 mm bore incl repair/rereplacement of required GI fitting and connected work all as direc ted.
Taking out existing defective stand post hydrants landing valves single controle of size 63/65 mm bore and supply & fix new fore hydrant landing valves single controll of size 63/ 65 mm bore incl replacement of rubber gasket,etc. all as directed.
Taking out existing defective hose reel drum of 30 mtr length ISI marked complete with nozzle and coupling and supply & fix new hose reel drum of 30 mtr length ISI marked complete incl nozzle and coupling all as specified and as directed.
Taking out existing defective RRL hose type-A 15mtr in length, complete with nozzle and coupling supply & fix new RRL hose type-A 15mtr length ISI marked complete incl brass/ GM nozzle,male and femail coupling and all as specified and as directed.
Taking out existing defective Contactor for starter and supply & fix new Contactor of size 3 ph 415 v 16 amp incl replacement nut and bolt etc. all as directed Make L&T Cat. No MNX9 or equvalent
Taking out existing defective overload relay supply & fix new overload relay of size 6-19 a incl replacement of nut and bolt etc. all as directed. Make L&T Cat No FN 3240T or equivallent.
Taking out existing defective single phase preventor supply & fix new single phase preventor three phase incl replacement of nut and bolt etc. all as directed. Make Minilec VSP2 or equivallent.
Taking out existing defective starter and supply & fix new fully automatic star delta starter AC 3, 415 V, 50 HZ, 3 phase cap 20 Hp make L&T type MU G20 cat pt No SS95975 or Equivallent
Supply and fix in replacement 4 pole power contractor 18A/20A AC3 Rating Suitable for 7.5HP / 5.6kW AC Motors Suitable for MK 1 Starters 110V AC 50Hz Control Voltage Coil as directed by Engr in Charge.
Supply and fix in replacement MCCB 125 Amp 3 pole with thermal magnetic release 100 to 125 Amp, breaking capacity 16 KA Make L&Tcatpt no SL98653OOOO OR as per sample and directed.
Supply and fix in replacement power contactor 3 pole,415 volt, 50 HZ, 70 to 100 Amp cap Make-L&T as per sample and directed or equivallent to other make..
Supply and fix in replacement electronic timer 3 to 30 sec 240/415 Volt as required at site type ST 100 of MakeL&T as persample or other equivallant and as directed directed.
Supply and fix in replacementwater level controller with water level controller probe for draining and filling application 240/415 Volt MakeL&T as per sample or other equivallant and as directed directed.
Supply and fix in replacement indicator lamp showing R Y B in the panel per sample or as directed directed.
Supply and fix in replacement MCB TP 32 Amp 415 Volt including taking out existing one all as directed.
Supply and laying Rubber insulating mats for electrical safety floor coverings in areas 1 mtr x 2 mtr 19 mm thick size
M & L for Painting of steel/iron surfaces of fire fighting system with existing colour single coat of synthetic enamel paint over old painted surface incl preparation of existing surfaces all as directed.
M&L for MS pipe 80 mm bore heavy duty and fixing with existing system by welding etc including rubber coating to the pipe taking out existing one all as directed make bansal or electro steel
M&L for lifting out and removing non functional submersible pump set of any description and capacity (7.5 HP to 10 HP) & in any position, alongwith existing column pipe 50mm dia and existing submersible cable of any size from the bore well (approximately 500 feet depth of pump set from GL)after disconnecting the electrical connection from panel, dismantling existing CI bend from non return valve, and staking the pump and column pipes near by the bore well for inspection complete all as specified and directed . (including notes mentioned here in below) Note for items No 39 :- 1. Contractor shall take proper precautions while lifting out and removing pump set from bore well so as to avoid any damage to column pipe and submersible cable. All necessary T&P and equipments required for lifting out pump set etc shall be arranged by the contractor at his own cost. 2. Number of column pipe may vary from 30 to 50, The existing pipes , screwed and socket joints shall be checked for its serviceability & unserviceable joints alongwith flanges shall be removed from the column pipe by cutting the pipes & making new thread in pipes for fixing of new socket and nut bolt, the cost of same shall be deemed to be included in the quoted rate for above item. However replacement of pipes if any required shall be measured & paid separately.
M&L in replacement of existing U/S MS water tubing as in column pipe, 50mm bore, medium grade of thickness 4.5mm, ISI marked, conforming to relevant IS for column pipe in required length but length not more than 3.00 mtr, both end threaded. One end internally and other end externally threaded and duly welded with pipe using 4 Nos MS strips of size 20x 3mm in triangular right angled shape with provision of 04 Nos holes and side slot for passing submersible cable on threaded end, including painting with two coats of anti corrosive bituminous paint over a coat of red oxide primer complete all as specified and directed.
Taking out & removing old burnt out windings wire of the submersible electric motors of 7.5 HP, Three phase, 415 Volts, 50 Hz, AC supply capacity and rewinding of submersible electric motors with existing size PVC insulated, copper conductor wire including cleaning the slots with carbon- tetra-chloride solution before rewinding ,transportation to site complete all as specified and directed Notes : (i) Replacement of unserviceable parts shall be measured and paid for separately under appropriate item of Sch `A` as supply only but fixing charges of the parts replaced/repaired is deemed to be included in the above quoted rates. (ii) The windings of motor including windings wire and connected material is deemed to be included in the quoted rates
(a) Gun metal bush
(b)Thurst plate
© Shaft Grinding and polishing
Dismentalling of submersible pumpset of capacity 7.5 HP cleaning and inspection of parts removal all defective parts & replacement of defective impellers, bushes, shaft, locking pin and non return valve,rematling and repairing of repairable item reassembling testing and commissioning all as directed by eng in charge.Notes : (i) Replacement of unserviceable parts shall be measured and paid for separately under this item saperately as supply only but fixing charges of the parts replaced/repaired is deemed to be included in the above quoted rates.
(a) Impeller as per existing size
(b)Difuser as per existing size
(c ) Gunmetal bushes
(d) Coupler for motor and pump
(e) Non return valve
Lowering down of the submersible pump set of any description and any capacity & in any position, in bore well alongwith column pipe 50mm dia and submersible cable of any size (approximately 500 feet depth of pump set from GL) including making necessary electric connections and providing water tight cable joint & testing the pump set after lowering complete all as specified and directed (including notes mentioned here in below) NOTES :- 1. Contractor shall take proper precautions while lowering pump set in bore well so as to avoid any damage to column pipe and submersible cable. All necessary T&P and equipments required for lowering of pump set etc shall be arranged by the contractor at his own cost. 2. Rates quoted by the contractor for the above item includes the cost of assembling & connecting pump set to column pipes & assembling, jointing and fixing column pipes with MS internally threaded flange welded with column pipe by using 04 Nos 20x3mm MS strips and thereafter jointed with rubber gasket joints and nuts, bolts / pump set at the end / submersible cable and making necessary connections and testing including reconnecting water supply system. The required materials like column pipe /flanges with rubber gasket joints/ submersible cable/ repaired pump sets etc shall be met out with old retrieved materials and additional quantity of column pipe, flanges with rubber gasket joints , submersible cable & straight through joint of cable shall be measured and paid for separately under respective item of this Schedule as “Supply only”, but the rate for its fixing shall be deemed to be included under this item.
Supply only 4 Sqmm, 3 Core, flat submersible Cable, PVC insulated, PVC sheathed with multi-stranded copper conductors, conforming to IS : 694- 1990 of 1100 Volt grade, dismantled/fixed under Sch ‘A’ item No. 13 here in above complete all as specified and directed
Disconnecting and taking up or down old existing GI tubing and connections 20 mm bore,including connected fittings/accessories and fixtures of any description/ grade and in any position in trenches/under floors/road / on walls etc and making good the disturbed surface complete all as specified and directed
ditto but 25 mm bore
ditto but 40 mm bore
ditto but 50 mm bore
Supply, fixing, laying, jointing & testing 20 mm bore of galvanised iron water tubing 'medium grade' conforming to IS-1239 with and including all GI fittings such as unions, reducer sockets, socket reducing bends, elbows, tee, checknuts, caps, plugs etc as required complete fixed checknuts, caps, plugs etc as required complete fixed to walls and ceilings, laid in trenches/under floor/under road or floors complete all as specified and directed
ditto but 25 mm bore
ditto but 40 mm bore
ditto but 50 mm bore
M&L for servicing/overhauling/repairing of existing defective centrifugal pump of following capacity ,3 Phase,415 volts, AC supply and cleaning, oiling/greasing, fixing of serviceable parts in position, oiling/greasing,refixing of serviceable parts in position,balancing, realignment etcreplcement of nut bolt washer where required, welding braging and trasportation to workshop if required, Repair to bearing housing with metling and turning and fixing the same in position and testing on full load complete all as specified and directed. Booster/centrifugal pump of capacity 60 HP (i) Replacement of unserviceable parts if required shall be measured and paid for separately under appropriate item of Sch `A` as supply only but fixing charges of the parts replaced/repaired is deemed to be included in the above quoted rates.
(b) Booster/centrifugal pump of capacity 15 HP,
(C) Booster/centrifugal pump of capacity 7.5HP,
(d) Booster/centrifugal pump of capacity 5HP,
(e) Booster/centrifugal pump of capacity 3 HP,
(f) Booster/centrifugal pump of capacity 1 HP,
Disconnecting and removing of following old existing non functional booster pump / centrifugal pump of any description and in any position, dismantling and strip opening of the motor and pump, for carrying out repair/ servicing /overhauling mechanically and electrically, cleaning, oiling/greasing, fixing of serviceable parts in position, removing & replacement of defective / unserviceable parts with new parts, ie bearing,connecter, fan blade, nuts and bolts etc with and including removing the old existing burnt windings, cleaning the slots & rewinding of the electric motor 7.5 HP operating on 415 V, 3 Phase, 50 Hz AC supply with existing gauge super enameled copper wire, including insulating material such as illuminous paper, Letherized paper, cotton tape, glass sleeves insulating varnish etc and any trasportation to workshop if required,and fixing the same in position and testing on full load complete all as specified and directed. Notes : (i) Replacement of unserviceable parts shall be measured and paid for separately under appropriate item of Sch `A` as supply only but fixing charges of the parts replaced/repaired is deemed to be included in the above quoted rates. (ii) The windings of motor including windings wire and connected material is deemed to be included in above quoted rates.
(a) Ball bearing no 6308 of SKF
(b) Ball bearing no 6208 of SKF
© Gun metal Bush
(d) CI Impellar
(e )Connection plate
(f) Cooling fan blade
Disconnecting and taking down the existing water chlorination doser from the existing location at pump house and testing to the entire satisfaction of Engr-in-charge after cleaning and de-scaling the inner tank and other parts / accessories including inlet, outlet etc. as approved by Engineer-in-Charge, Note: Required screws, insulating tapes, gasketst and other minor items in serviceable condition, will be arranged & supplied by the contractor and cost of which is deemed to be included in the rates quoted by the contractor in respective item.
Supply only bleaching powder in 25 Kgs bag having 35 % chlorine contentof Ein C approved make.
M&L forCleaning of UG sump of residential area and by draining out complete water removing deposits from bottem,scratching out silt ,dirt from surfaces of the tank of inner surfaces . carrying out two coat of lime wash on inner surfaces, after drying up of capacity 30000 ltr located at domesic area. All as directed and approved by Engineer-in-Charge
M&L for Cleaning of UG sump oftechanical area and by draining out complete water removing deposits from bottem,scratching out silt ,dirt from surfaces of the tank of inner surfaces . carrying out two coat of lime wash on inner surfaces,after drying up of capacity 20000 ltr located behind the admin building. All as directed and approved by Engineer-in-Charge
M&L for Cleaning of UG sump of techanicall area and by draining out complete water removing deposits from bottem,scratching out silt ,dirt from surfaces of the tank of inner surfaces . carrying out two coat of lime wash on inner surfaces, after drying up of capacity 75000 ltr in two compartment, located at domesic area. All as directed and approved by Engineer-in-Charge
M&L for plate earthing complete with galvanized mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 meter deep below ground level) with the top edge of earth plate at a depth not less than 1.5 meter below normal ground level, connected to gaivanised iron strip 25 mm x 4 mm by means of bolts, nuts, check nuts and washer of gaivanised iron or steel all as shown in electrical plate no.3 connected to earthing test point all as specified or indicated including testing on completion.
M&L for repair and removal of leakage in the main pipe line by any means like rethreading replacement of socket, union, inserting nipple etc including earth work etc required to complete the job for size 20 to 25 mm bore
- Ditto - but 40 mm to 50 mm bore
S&F in repair CI non return valve vertical type suitable for 80 mm bore pipe line including nut bolt washer and rubber gasket all as directed including taking out existing one and shifting to store make Kalpana.
S&F in repair CI non return valve vertical type suitable for 150 mm bore pipe line including nut bolt washer and rubber gasket all as directed including taking out existing one and shifting to store Make Kalpana.
S&F flexible rubber coupling of delivery vertcal pipe line of out let of pump set of size 80 mm bore with nut bolt washer etc after diisconnecting and taking out old existing coupling with old nut bolt and washer etc, complete all as directed.
- Ditto - all as above but for pipe size 150 mm bore
S&F in repairBrass/GM foot valve vertical type suitable for 40 mm bore pipe line including threading to pipe and connecting all as directed including taking out existing one and shifting to store Make leader or equivallent
Note :-Tenderers may be noted that amount of credit will be deducted from the total amount arrived, at the time of Acceptance of contract.
M/S BHATT ENTERPRISES
Amit Engineering
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .