Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance 240A POCKET C2 DDA JANTA FLATS MAYUR VIHAR PHASE 3 EAST DELHI DELHI 110096 | EAST DELHI | DELHI | 110096 | Admitted-Finance |
| 3 | Admitted-Finance C 27 MANOJ C 27 SUKHWANI GANESH NAGAR DAPODI DAPODI PUNE MAHARASHTRA 411012 | PUNE | MAHARASHTRA | 411012 | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance B 404 NEW ASHOK NAGAR NEW DELHI EAST DELHI DELHI 110096 | EAST DELHI | DELHI | 110096 | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
26 Aug 2019, 2:00 pmClosed
Director,DEAL
DEAL,Dehradun
As per Tender Document
2019_DRDO_489313_1
DEAL/29/4043/19-20/DEA-114/098
Open Tender
Electronics Equipment
Buy
60 days
DEAL
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹50,000
Yes
24 Apr 2020
26 Jul 2019
27 Aug 2019
26 Jul 2019
26 Aug 2019
26 Jul 2019
26 Jul 2019 - 19 Aug 2019
Supply, installation, testing and commissioning of Precision air conditioning units
Precision Air Conditioning Unit : • Bottom discharge , Single Circuit 4.8 TR Actual Capacity (at design condition of 44 Deg C ambient). • In Built Humidity control function (dehumidification / humidification) Relative humidity : 50% variation shall not exceed +/-5% at AC suction point. • Optimal temperature of 24 ° C ±1° at AC suction point • Design for operation at high ambient of 47 deg C DBT and at low ambient of up to -5 deg C DB temperatures. . Unit should have Fan Speed Controller in indoor unit to ensure all condenser fan speed is variable in accordance to the Ambient Conditions. (On/Off method is not allowed) • PAC should have Scroll Compressor operating on R410A / R134A Refrigerant , Electronic Expansion Valve, Liquid Receiver, Liquid Line Solenoid Valve, Additional safety with Pressure Relief Valve, with Heater and Modulating Humidifier, Crankcase heater. • Unit shall be double skin construction on all four sides • Unit controller should read & display real time values of Superheat, Suction Pressure, Suction Temperature, Discharge Pressure and Discharge temperature of the refrigerant to ensure that health of PAC can be checked without opening the unit. • Visual alarm indication
Supply of Pair of Copper Pipe with Fittings and support
Supply of MS Stand for Indoor and Outdoor
Supply of Refrigerant R410A
Supply of GI Drain Pipe
Supply of GI Humidifiier Inlet Pipe
Supply of Condenser Cable
Supply of Main incoming Power Cable
Supply of Floor Grilles with VCD
Supply of Extended Piping Kit
Job work of Unloading, lifting/ shifting & positioning of Precision AC units at the first floor (Datacenter); Its installation, testing and commissioning. The indoor units will be placed on Raised Access Floor (already installed) and outdoor units will be installed at the ground floor (as per the diagram attached). The job work includes minor electrical work and civil work (including repairing with finishing of all damage to site). All the accessories including Electric cable, MCCBs etc as required for the installation and operation of the system will be supplied by the vendor
SHES Air And Automation
Technoware Systems India Private Limited
SYNAPSE
Saitech Systems Pvt.Ltd.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .