Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.7 LAccepted-Finance | L1 | Accepted-Finance L1 BIDDER | |
| 2 | L2₹10.3 L+₹61,600 (6.34%)Accepted-Finance | L2 | Accepted-Finance L2 BIDDER | |
| 3 | L3₹10.4 L+₹72,560 (7.47%)Accepted-Finance | L3 | Accepted-Finance L3 BIDDER |
Tender Value
₹13.0 L
EMD Value
₹13,000
Closing Date
3 Oct 2023, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE ETC I, Lucknow
Pareshan Bhawan, Vibhuti Khand, Luciknow
work
2023_UPTCL_834925_2
Very short term e-tender 46/2023-24
Open Tender
Electrical Works
Piece-work
30 days
Lucknow
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
A/c No 2408002190005438, IFS PUNB0691100, PNB, Lko
₹13,000
11 Oct 2023
23 Sept 2023
4 Oct 2023
23 Sept 2023
3 Oct 2023
23 Sept 2023
Amount
(A) SUPPLY
1) P.G Clamp ACSR Panther to Panther conductor
2) P.G Clamp ACSR Moose to Panther conductor
3) P.G Clamp ACSR Moose to Moose conductor
4) P.G Clamp ACSR Moose to Zebra conductor
5) Spacer for Twin Moose Conductor 02 Bolts, 250 mm spacing made of Aluminium alloy LM-6 complete with nuts,bolts & washers confirming to BIS:5561
6) Spacer for Twin Moose Conductor 02 Bolts, 100 mm spacing made of Aluminium alloy LM-6 complete with nuts,bolts & washers confirming to BIS:5561
7) Spacer for Twin Panther Conductor 02 Bolts, 100 mm spacing made of Aluminium alloy LM-6 complete with nuts,bolts & washers confirming to BIS:5561
8) Bolted type Single Tension fitting for "Twin Moose" conductor w/o Turn buckle for 132 KV Main Bus Bar suitable for 70 KN Disc Insulator string with 02 No. Tension Clamps made of Al. Alloy LM-6 Yoke Plate,D-Shackle,D-Socket etc. made from Forged Steel etc.
9) Bolted type Single Suspension fitting for "Twin Moose" conductor for 132 KV Main Bus Bar suitable for 70 KN Disc Insulator string with 02 No. Tension Clamps made of Al. Alloy LM-6 Yoke Plate,D-Shackle,D-Socket etc. made from Forged Steel etc.
10) Bolted type Single Tension fitting for Single Moose conductor w/o Turn buckle for 132 KV Transfer Bus Coupler Bay suitable for 70 KN Disc Insulator string with 02 No. Tension Clamps made of Al. Alloy LM-6,D-Shackle,D-Socket etc. made from Forged Steel etc.
11) Bolted type Single Suspension fitting for "Single Moose" conductor for 132 KV Transfer Bus Coupler Bay suitable for 70 KN Disc Insulator string with 02 No. Tension Clamps made of Al. Alloy LM-6 D-Shackle,D-Socket etc. made from Forged Steel etc.
12) 132 KV P.T/CVT Clamp duly made of Aluminium Alloy (LM-6) Suitable for ACSR Moose Conductor complete with bolts, nuts & Washers as per sample Confirming to BIS:5561.
13) 132 KV Isolator Clamp duly made of Aluminium Alloy (LM-6) Suitable for Twin ACSR Panther Conductor complete with bolts, nuts & Washers as per sample .
14) 132 KV Isolator Clamp duly made of Aluminium Alloy (LM-6) Suitable for ACSR Moose Conductor complete with bolts, nuts & Washers as per sample .
15) 132 KV CB Clamp duly made of Aluminium Alloy (LM-6) Suitable for ACSR Moose Conductor complete with bolts, nuts & Washers as per sample .
16) 132 KV CT Clamp duly made of Aluminium Alloy (LM-6) Suitable for ACSR Moose Conductor complete with bolts, nuts & Washers as per sample .
(B) Work
1) Opening of existing jumpers of Twin/Single ACSR Panther/Zebra/Moose conductor between Main Bus to 12 No. Bus Isolator, of 06 No.Line Bay T/F,05 No. P.T,03 No. 01 NoTBC bay to Main Bus (01 Job for each Jumper).
2) De-Stringing & Dismantling of existing 132 KV Main Bus of Single ACSR Zebra conductor after opening of Disc Insulator string & Tension Fitting from Gantry,lowering the Bus Bar conductors including shifting of the old conductor from switchyard to substation store and stacking/placing of same at suitable place at the stores (01 Job for each phase of each section of Bus Bar)
3) Laying & Re-Stringing of 132 KV Main Bus Bar of Twin ACSR Moose Conductors including Hoisting of Disc Insulator string & Tension Fitting etc. and Jointing Section of 132 KV Main Bus by ''U'' shaped Twin Jumpers between adjacent bus Section with the help of suitable double P.G Clamp including shifting of the conductors/Materials from store to switchyard (01 Job for each phase of each section of Bus Bar)
4) De-Stringing & Dismantling of existing 132 KV Jack Bus for Transfer Bus Coupler Bay of Single ACSR Panther conductor after opening of Disc Insulator string & Tension Fitting from Gantry,lowering the Bus Bar conductors including shifting of the old conductor from switchyard to substation store and stacking/placing of same at suitable place at the stores (01 Job for each phase of each section of Bus Bar)
5) Laying & Re-Stringing of 132 KV Jack Bus for Transfer Bus Coupler Bay of Single ACSR Moose Conductors including Hoisting of Disc Insulator string & Tension Fitting etc. and Jointing Section of 132 KV Main Bus by ''U'' shaped Jumpers between adjacent bus Section with the help of suitable double P.G Clamp including shifting of the conductors/Materials from store to switchyard (01 Job for each phase of each section of Bus Bar)
6) Fixing of spacer between twin ACSR Moose conductor of above newly laid 132 KV main bus bar.
7) Jumpering with Twin ACSR Panther conductor between newly laid 132 KV Main Bus Bar to 05 No. Line Isolator,03 No. T/F,02 No. P.T,01 No. Section Isolator bay to Main Bus (01 Job for each Jumper).
8) Jointing Section of 132 KV Main Bus by 'U' shaped twin jumpers between adjcent bus section with the help of suitable double PG Clamp (I Job for each jumper)
9) Opening of existing Jumpers of Single ACSR Panther Conductor between existing 132 K.V. BI to other equipments of of 132 KV Transfer Bus Coupler Bay.
10) Jumpering of 132 K.V. TBC Bay with ACSR Moose conductor from 132 K.V. BI to other equipments. (01 Job per bay).
11) Dismantling of following Equipments as per instruction manual and technical specifications including shifting of materials from Central Stores to Erection Site, opening of jumpers including all associated works.
i) 145 KV PT
ii) 145 KV CT
iii)145 KV PT Junction Box
iv) 145 KV Bus Isolator Non Motorised Central Break with associated Post Insulator.
12) Erection of following Equipments as per instruction manual and technical specifications including shifting of materials from Central Stores to Erection Site, jumpering of conductor including all associated works.
i) 145 KV PT
ii) 145 KV PT Junction Box
iii) 145 KV CT
iv) 145 KV Bus Isolator Non Motorised Central Break with associated Post Insulator.
13) Laying of following sizes Control Cables in the Cable Trenches from Control and Relay Panels in Control Room to various Equipments, Junction Box etc. in Swithcyard as per cable schedule, its sddling with 25X3 mm size including carriage of Cable Drums from Stores to work site & shifting back to stores including allother associated works required for the satisfactorily completion of the Job as per technical specification.
i) Laying of 2X2.5 sq. mm size Control Cable
ii) Laying of 4X2.5 sq. mm size Control Cable
M/s Janta Charan
MANAS ELECTRICALS
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .