| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.8 CrAccepted-AOC | ₹5.8 Cr | L1 | Accepted-AOC become L1 |
| 2 | L2₹6.1 Cr+₹34.8 L (6.01%)Rejected-Finance | ₹6.1 Cr+₹34.8 L (6.01%) | L2 | Rejected-Finance NOT MEETING NIT CRITERIA |
| 3 | L3₹6.2 Cr+₹45.0 L (7.77%)Rejected-Finance PLOT NO 9 GROUND FLOOR HIGH TECH MADHAPUR KONDAPUR HYDERABAD TELANGANA 500084 | HYDERABAD | TELANGANA | 500084 | ₹6.2 Cr+₹45.0 L (7.77%) | L3 | Rejected-Finance NOT MEETING NIT CRITERIA |
| 4 | L4₹7.4 Cr+₹1.6 Cr (27.8%)Rejected-Finance UNIT B2 AUTONAGAR VISAKHAPATNAM VISAKHAPATNAM ANDHRA PRADESH 530012 | VISAKHAPATANAM | ANDHRA PRADESH | 530012 | ₹7.4 Cr+₹1.6 Cr (27.8%) | L4 | Rejected-Finance NOT MEETING NIT CRITERIA |
Tender Value
₹6.5 Cr
EMD Value
₹12.9 L
Closing Date
20 Aug 2020, 6:00 pmClosed
Senior Manager (Engg-Civil)
Airports Authority of India, Rajahmundry Airport, Madhurapudi Post, Rajahmundry-533102
Construction of Administrative Block for AAI Staff at Rajahmundry Airport
2020_AAI_53022_1
AAI/RJY/ENGG(C)/Admn.Blg/20-21
Open Tender
Civil Works
Item Rate
300 days
Airports Authority of India, Rajahmundry Airport
Please refer Tender Document
12 documents required · 12 mandatory
₹1,680
Airports Authority of India
₹12.9 L
4 Dec 2020
15 Jul 2020
27 Aug 2020
16 Jul 2020
20 Aug 2020
16 Jul 2020
16 Jul 2020 - 17 Aug 2020
CIVIL WORKS Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be leveled and neatly dressed. All kinds of soil
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m. Pipes , cables etc, exceeding 80 mm dis but not exceeding 300 mm dia.
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m. Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Supplying and filling in plinth with Jamuna/fine sand under floors or, any where required including, watering, ramming consolidating and dressing complete
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size)
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size).
Applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size).
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size).
Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete
Centering and shuttering including strutting, propping etc. and removal of form for : Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform.
Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers.
Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillors,Piers,Abutments,Posts and struts
Centering and shuttering including strutting, propping etc. and removal of form for : Stairs,(excluding landings) except spiral-staircases
Centering and shuttering including strutting, propping etc. and removal of form for : Edges of slabs and breaks in floors and walls. Under 20 cm wide
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)
Half brick masonry with common burnt clay F.P.S (non modular) bricks of class designation 7.5 in super structure above plinth level upto floor V level. Cement mortar 1 : 4 (1 cement : 4 coarse sand)
Extra for providing and placing in position 2 Nos. 6mm dia. M.S. bars at every third course of half brick masonry
Brick work with clay flyash F.P.S. (non modular) brick of class designation 7.5 in superstructure above plinth level up to floor five level in : Cement mortar 1:6 (1 cement : 6 coarse sand)
Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished) machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade.
Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone work including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building, all complete as per the architectural drawings, with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand), laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade, including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Providing wood work in frames of doors, windows, clerestory window and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately) Second class teak wood
Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.
Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured).
Providing 40x5 mm flat iron hold fast 40cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 250x10 mm
Providing and fixing bright finished brass handles with screws etc. complete : 125 mm
Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.
Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles with necessary screws etc. complete.
Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt / suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S including cost of adhesive of approved quality 1.0 mm thick.
Providing and fixing plain lining with necessary screws/nuts & bolts/nails including a coat of approved primer on one face and fixed on wooden /steel frame work complete as per direction of Engineer-in-charge. (Frame work shall be paid for separately) 12mm thick commercial ply conforming to IS : 1328 BWR type.
Providing and fixing factory made uPVC white colour asement/casement cum fixed glazed windows comprising of uPVC multichambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately) Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Casement window double panels with top fixed with S.S. friction hinges (350 x 19 x 1.9 mm) made of (small series) frame 47 x 50 mm, sash 47 x 68 mm & mullion 47 x 68 mm all having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area of window upto 2.50 sqm).
Providing and fixing factory made uPVC white colour fixed glazed windows/ventilators comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately). Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area upto 0.75 sqm.)
Providing and fixing frame work for partitions/ wall lining etc. made of 50x50x1.6mm hollow MS tube, placed along the walls, ceiling and floor in a grid pattern with spacing @ 60 cm centre to centre both ways (vertically & horizontally ) or at required spacing near opening, with necessary welding at junctions and fixing the frame to wall/ ceiling/ floors with steel dash fasteners of 8 mm dia, 75 mm long bolt, including making provision for opening for doors, windows, electrical conduits, switch boards etc., including providing with two coats of approved steel primer etc. complete, all as per direction of Engineer-in-charge.
Providing and fixing fire resistant door frame of section 50 x 60 mm on horizontal side & 35 x 60 mm on vertical sides having built in rebate made out of 1.6 mm thick GI sheet ( Zinc coating not less than 120gm/m²) suitable for mounting 120 min Fire Rated Glazed Door Shutters. The frame shall be filled with Mineral wool Insulation having density min 96Kg/m³ . The frame will have a provision of G.I. Anchor fastners 14 nos ( 5 each on vertical style & 4 on horizontal style of size M10 x 80 ) suitable for fixing in the opening along with Factory made Template for SS Ball Bearing Hinges of Size 100x89x3mm for fixing of fire rated glazed shutter. The frame shall be finished with a approved fire resistant primer or Powder coating of not less than 30 micron in desired shade as per the directions of Engineer - in- charge . (Cost of SS ball bearing hinges is excluded).
Providing and fixing 60 mm thick glazed fire resistant door shutters of 120 min Fire Rating confirming to IS:3614 (Part II) or EN1634- 1:1999, tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, top rail & side rail 60 mm x 60 mm wide and bottom rail of 110 mm x 60 mm made out of 1.6mm thick G.I. sheet (zinc coating not less than 120gm/m²) duly filled mineral wool insulation having density min 96 kg/m³ and fixing with necessary stainless steel ball bearing hinges of size 100x89x3mm of approved make, including applying a coat of approved fire resistant primer or powder coating not less than 30 micron etc all complete as per direction of Engineer-in-charge (panelling to be paid for seperately).
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete:
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces.
Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes,channels, plates etc. including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge. ( for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts,fasteners etc.)
Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard,jointed with neat cement slurry mixed with pigment to match the shade of tiles including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Medium shade pigment using 50% white cement 50% Grey cement
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand) including pointing the joints with white cement and matching pigment etc., complete.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption's less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer) with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make in all colours & shade in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm
Making khurras 45x45cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20mm nominal size) over P.V.C. sheet 1mx 1mx400 micron, finished with 12mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement rounding the edges
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. (i) Single socketed pipes. 110 mm diameter
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Coupler - 110 mm
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Single tee without door 110x110x110 mm
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Bend 87.5° 110 mm bend
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Shoe (Plain) 110 mm Shoe
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
Providing and fixing at all height false ceiling including providing and fixing of frame work made of special sections power pressed from M.S. sheet and galvanised in accordance with zinc coating of 120gms/sqm ( both side inclusive) as per IS : 277 and consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 27mm and 37mm at 1200mm centre to centre one flange fixed to the ceiling with dash fastener 12.5mm diax50mm long with 6mm dia bolts to the angle hangers of 25x10x0.50mm of required length, and other end of angle hanger being fixed with nut and bolts to G.I. channels 45x15x0.9mm running at the rate of 1200mm centre to centre to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre shall be fixed in a direction perpendicular to G.I.intermediate channel with connecting clips made out of 2.64mm diax230mm long G.I. wire at every junction including fixing peremeter channel 0.5mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre, with 25mm long drive-all screws @ 230mm interval, including fixing and Gypsum board to ceiling section and peremeter channel with the help of drive wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers coveing upto 150mm on both sides of joint and two coats of primer suitable for board, all as per manufacture's specification and also including the cost of making opening for light fittings, grills, diffusers, cutout made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer-in-charge but excluding the cost of painting with: 12.5 mm thick tapered edge gypsum moisture resistant board.
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required
Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture spintone/cosmos / Hexa or equivalent of size 595 x 595 mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main 'T' runner suitably spaced at joints to get required length and of size 24x38mm made from 0.33 mm thick (minimum) sheet, spaced 1200mm centre to centre, and cross "T" of size 24x28mm made out of 0.33mm (Minimum) sheet, 1200mm long spaced between main'T' at 600mm centre to centre to form a grid of 1200x600mm and secondary cross 'T' of length 600mm and size 24 x28mm made of 0.33mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600mm panel to from grid of size 600x600mm,resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450mm centre to centre with 25mm long dry wall screws @ 230mm interval and laying 15mm thick densified edges calicum silicate ceiling tiles of approved texture (Spintone / Cosmos/hexa) in the grid including, cutting/ making opening for services like diffusers, grills,light fittings,fixtures, smoke detectors etc., whereever required, Main 'T' runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6mm fixed to ceiling with 12.5 mm dia and 50mm long dash fasteners, 4mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200mm centre to centre along main 'T' , bottom exposed with 24mm of all T-sections shall be pre-painted with polyster baked paint, for all heights, as per specifications,drawings and as directed by engineer-in-charge.
12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand)
15 mm cement plaster on the rough side of single or half brick wall of mix:1:6 (1 cement: 6 fine sand)
6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand)
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm).
Finishing walls with textured paint of approved shade Asian paint or equivalent: New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including base coat of water proofing cement paint applied @ 2.20kg/10 sqm.
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture.
Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Two coats.
Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm. depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres.
Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) in pavements, laid to required slope and camber in panels as required including consolidation finishing and tamping complete.
Manufacturing, supplying and fixing retro reflective sign boards made up of 2mm thick aluminium sheet, face to be fully covered with high intensity encapsulated type heat activated retro reflective sheeting conforming to type - IV of ASTM-D 4956-01 in blue and silver white or other colour combination including subject matter, message (bi-lingual), symbols and borders etc. as per IRC ; 67:2001, pasted on substrate by an adhesive backing which shall be activated by applying heat and pressure conforming to class -2 of ASTM-D-4956-01 and fixing the same with suitable sized aluminium alloy rivets @ 20 cm c/c to back support frame of M.S. angle iron of size 25x25x3 mm along with theft resistant measures, mounted and fixed with 2 Nos. M.S. angles of size 35x35x5 mm to a vertical post made up to M.S.Tee section ISMT 50x50x6 mm welded with base plate of size 100x100x5 mm at the bottom end and including making holes in pipes, angles flats, providing & fixing M.S. message plate of required size, steel work to be painted with two or more coats of synthetic enamel paint of required shade and of approved brand & manufacture over priming coat of zinc chromate yellow primer (vertical MS-Tee support to be painted in black and white colours). Backside of aluminium sheet to be painted with two or more coats of epoxy paint over and including appropriate priming coat including all leads and lifts etc. complete as per drawing , specification and direction of Engineer--in-charge.
Manufacturing, supplying and fixing retro reflective sign boards made up of 2mm thick aluminium sheet, face to be fully covered with high intensity encapsulated type heat activated retro reflective sheeting conforming to type - IV of ASTM-D 4956-01 in blue and silver white or other colour combination including subject matter, message (bi-lingual), symbols and borders etc. as per IRC ; 67:2001, pasted on substrate by an adhesive backing which shall be activated by applying heat and pressure conforming to class -2 of ASTM-D-4956-01 and fixing the same with suitable sized aluminium alloy rivets @ 20 cm c/c to back support frame of M.S. angle iron of size 25x25x3 mm along with theft resistant measures, mounted and fixed with 2 Nos. M.S. angles of size 35x35x5 mm to a vertical post made up to M.S.Tee section ISMT 50x50x6 mm welded with base plate of size 100x100x5 mm at the bottom end and including making holes in pipes, angles flats, providing & fixing M.S. message plate of required size, steel work to be painted with two or more coats of synthetic enamel paint of required shade and of approved brand & manufacture over priming coat of zinc chromate yellow primer (vertical MS-Tee support to be painted in black and white colours). Backside of aluminium sheet to be painted with two or more coats of epoxy paint over and including appropriate priming coat including all leads and lifts etc. complete as per drawing , specification and direction of Engineer--in-charge. Cautionary /warning sign boards of equilateral triangular shape having each side of 900mm with support length of 3650mm.
Providing and laying 60mm thick factory made cement concrete interlocking paverblock of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of fine sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand) including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).
Construction of dry lean cement concrete sub base over a prepared sub-grade with coarse and fine aggregate conforming to IS:383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per specifications, cement content not to be less than 150 Kg/cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, for all leads & lifts, laid with a mechanical paver, compacting with 8-10 tonne vibrator
Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- (a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink without drain board 470x420 mm bowl depth 178 mm.
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing Rectangular shape 1500x450 mm
Providing and fixing toilet paper holder : C.P. brass
Providing and fixing soil, waste and vent pipes : 100 mm dia. Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905
Providing and fixing soil, waste and vent pipes : 75mm dia Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905
Providing and fixing plain bend of required degree. 100 mm Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905 Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905
Providing and fixing plain bend of required degree. 75 mm Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905
Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fitting of diameter: 100mm dia pipe
Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fitting of diameter: 75mm dia pipe
Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 100 mm inlet and 100 mm outlet Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905
Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/6 litre (adjustable to 4 litre/8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete.
Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 32 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & `testing of joints complete as per direction of Engineer in Charge. External work 25 mm nominal outer dia Pipes
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore.
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 a) 15mm nominal bore
Providing and fixing PTMT grating of approved quality and colour. Circular type 100 mm nominal dia
Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 250 mm dia
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design: 250 mm dia
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I.grating brick masonry chamber with water tight C.I. cover with frame of 300 x300mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 150 x 100 mm size P type. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 150 mm dia. R.C.C. pipe
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 finesand) including testing of joints etc. complete : 250 mm dia. R.C.C. pipe
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size), inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size), inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing M.S. Foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1: 3: 6 (1 cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) as per standard design : With 20x20 mm square bar
Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement :2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement and making necessary channels for the drain etc.complete : For pipes 100 to 250 mm diameter
Constructing brick masonry road gully chamber 45x45x77.5 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) with pre-cast R.C.C. vertical grating with frame complete as per standard design : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately).
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm. of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs c) After two days of proper curing applying a second coat of cement slurry using 2.75kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120mm and minimum thickness at khurra as 65 mm.
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer –in-charge, upto 90 metre depth below ground level. All types of soil 300 mm dia.
Supplying, assembling, lowering and fixing in vertical position in bore well,unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc.all complete, for all depths, as per direction of Engineer –in-charge. 150 mm nominal size dia.
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS:12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 150 mm nominal size dia.
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -incharge.
Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.
Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. (The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).
Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: (a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)- cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including: (b) Fabricating and supplying serrated M.S. hot dip galvanised /Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/ structural steel framework of building structure using stainless steel anchor fasteners/bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers. (c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass. (d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight. (e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer- in-Charge. Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this sub- head. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves ) on the external face shall be measured in sqm. up to two decimal places. Note:- 2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately. The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NBL Certified laboratories. (1) Performance Laboratory Test for Air Leakage Test (-50pa to - 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr (2) Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331-09 testing method for a range up to 2000 ml. (3) Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method for a range upto 2000 ml. (4) Structural Performance Deflection and deformation by static air pressure test (1.5 times desing wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm. (5) Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for Qualitative test. Tests to be conducted on site. (6) Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000 ml.
Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor.“(Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.26.2)“For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm.“ (i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.
Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including: (a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design (b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc.. (c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to revent bi-metallic contacts all complete required to perform as per specification and rawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium item.s The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places."
Horticulture & Land scaping DSR 2016 Supplying and stacking of good earth at site including royalty and carriage upto 5 km complete (earth measured in stacks will be reduced by 20% for payment)..
Supplying and stacking sludge at site including royalty and carriage upto 1km (sludge measured in stacks will be reduced by 8% for payment).
Fine dressing of the ground.
Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately).
Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge.
Providing and Displaying Acalypha plant Different colour well developed, fresh & healthy with good foliage, multi branch 30 to 45 cm ht. in 20 cm size of Earthen Pot/ Plastic Pot bushy plant as per direction of the officer-in-charge.
Providing and Displaying Acalypha twisted plant well developed with fresh & healthy 30 cm ht. in 20 cm size Earthen Pot/ Plastic Pot as per direction of the officer-in-charge.
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. Circular tank
Providing and fixing toilet cubicle (of following standard dimension which includes 600mm door size width) made of heat, bacteria, water, chemical, scratch, impact and anti bacterial resistant 12mm thick solid compact laminate should be suede/*Raw Silk,which includes doors, pilasters & intermediate panels finished with approved texture/shade as per the detail drawings & as per IS 2046 (Indian Standard) and as per fire retardant BS-476/97 standard. The product should have Green Guard Certificate. This also includes providing and fixing in position necessary hardware made out of stainless steel grade 304 finish as per manufacturer’s specifications & Architects instructions like (1) Door Knob, (2) Gravity Hinges, (3) Thumb turn lockset with Occupancy indicators, (4) coat hooks with Door stopper (5) U-Channels, (6)Adjustable foot/pedestal, (7) Top Rail, (8) Rubber noise deafening tape, (9)Screws & wall Plugs. All screws will of 304 Grade in stainless steel with satin finish. All pilasters are supported by Stainless steel Bottom Cladding. The base of the stainless steel bottom cladding will be anchored to the floor with a clearance height upto 150mm.As per direction of Engineer-in-charge.
Urinals Glass Partitions, alongwith all necessary accessories complete 8mm toughend glass on top width 650mm and bottom width 450 total height of the glass shall be 900mm and fixed to the wall on with two 'L' brackets . The gaps shall be filled with silicon etc as per the direction of EIC.
Providing and fixing glazed partition wall using 12mm thick cleared (saint gobine/modi make) using 25/22/2mm aluminium perpherial channel along the periphery or stainless p p y steel brackets fixed to floor with dash fastener as required as site including filling weather silicon sealant inside & outised to make the glazing water/air tight including fixing the free end of the partition with S.S. patch fitting all complete and as per instruction of the engineer-in-charge. Full Height glass Partition
Providing and fixing glazed partition wall using 12mm thick cleared (saint gobine/modi make) using 25/22/2mm aluminium perpherial channel along the periphery or stainless p p y steel brackets fixed to floor with dash fastener as required as site including filling weather silicon sealant inside & outised to make the glazing water/air tight including fixing the free end of the partition with S.S. patch fitting all complete and as per instruction of the engineer-in-charge. Low Height Glass Partition
Providing and laying for 400 micron PVC sheet over lean concrete
Providing and laying in position for expansion joint, 25mm thick pre-cut Synthetic joint filler board of approved make conforming to IS:1838(part 3)-2011, (45 mm from top to be removed at the time of filling of Polysulphide sealant), complete as per particular specifications and directions of Engineer-in-charge. (Note: Mode of measurement shall be length of joint multiplied by depth of filler board including precut portion.)-unit m2
Providing and laying in position with polysulphide (pouring grade) conforming to BS-5212-1990 of approved brand in expansion /construction / dummy joint including painting the contact surface of the joints with polysulphide primer of approved brand over and including expanded polyethylene armour rod in expansion / construction / dummy joints etc complete as per the direction of Engineer-in-charge. (For payment only polysulphide quantity to be considered) a) Expansion joints 25mm wide x 10mm deep over 30mm dia expanded polyethene armour rod.
Providing and laying in position with polysulphide (pouring grade) conforming to BS-5212-1990 of approved brand in expansion /construction / dummy joint including painting the contact surface of the joints with polysulphide primer of approved brand over and including expanded polyethylene armour rod in expansion / construction / dummy joints etc complete as per the direction of Engineer-in-charge. (For payment only polysulphide quantity to be considered) b) Construction joints 10mm vide x 10mm deep over 12mm dia expanded polyethylene armour rod (Total depth from the bottom of polyethylene rod to the top of joint will be 28mm)
Providing and laying in position with polysulphide (pouring grade) conforming to BS-5212-1990 of approved brand in expansion /construction / dummy joint including painting the contact surface of the joints with polysulphide primer of approved brand over and including expanded polyethylene armour rod in expansion / construction / dummy joints etc complete as per the direction of Engineer-in-charge. (For payment only polysulphide quantity to be considered) Dummy joints 10mm x 10mm deep over 8mm dia expanded polyethylene armour rod ( Total depth from the bottom of polyethylene to the top of joint will be 24mm)
Design of all works from foundation to finishing stage including detailed design of foundation work, structural design (RCC/Steel) and MEP design etc on the basis of inputs provided by AAI, from a reputed structrual designer as approved by Enginnering-In-Charge. The structrual designer shall ensure that the structral drawing should matching with the architectural drawing, any discripencies between architectural drawing, structural drawing and service drawings etc shall be resolved and correspondening final drawings duly stamped "Good for construction" be issued. The structraul drawings shall got proof checked/vetted from the independent institutes either any Govt universities or colleges and agency shall submitte the design and drawings for final approval of AAI. This item includes all cost for design including proof checking/vetting of design etc.
ELECTRICAL WORKS: SH-I: INTERNAL & EXTERNAL ELECTRICAL INSTALLATIONS Wiring for one point for light point/fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed Steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for group control points for light points with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed Steel conduit, and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable including all accessories etc. as required.(excluding switch & switch box).
Supplying and fixing following modular switch / socket with suitable modular base & cover plate, GI box in recess and modular blanking plate including connections as per site requirements etc. as required. 5/6 amp switch for Group controlled light point
Supplying and fixing following modular switch / socket with suitable modular base & cover plate, GI box in recess and modular blanking plate including connections as per site requirements etc. as required. 15/16 amps switch with 3 pin 15/16 amp socket outlet (combined shuttered type)
Supplying and fixing following modular switch / socket with suitable modular base & cover plate, GI box in recess and modular blanking plate including connections as per site requirements etc. as required. 5/6 amp switch with 3 pin 5/6 amp socket outlet (shuttered type)
Wiring for circuit/sub-main/Power plug/ Terrace light/UPS Light alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core in surface/recessed Steel conduit as required. 2 x 2.5 Sq..mm. + 1 x 2.5 sq. mm. earth wire
Wiring for circuit/sub-main/Power plug/ Terrace light/UPS Light alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core in surface/recessed Steel conduit as required. 2 x 4 Sq. mm+ 1 x 4 sq. mm earth wire
Wiring for circuit/sub-main/Power plug/ Terrace light/UPS Light alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core in surface/recessed Steel conduit as required. 2 x 6 sq. mm + 1 x 6 sq.mm earth wire
Supplying and fixing of following sizes steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 25 mm dia
Supplying and fixing of following sizes steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 32 mm dia
Supply and drawing of wires along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core in existing conduit/raceway as required. 2 x 1.5 sq. mm + 1 x 1.5 sq.mm earth wire
Supply and drawing of wires along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core in existing conduit/raceway as required. 2 x 2.5 sq. mm + 1 x 2.5 sq.mm earth wire
Supply and drawing of wires along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core in existing conduit/raceway as required. 2 x 4 sq. mm + 1 x 4 sq.mm earth wire
Supply and drawing of wires along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core in existing conduit/raceway as required. 2 x 6 sq. mm + 1 x 6 sq.mm earth wire
Supplying and fixing following way, single/ three pole and neutral, pre-wired, sheet steel, MCB Distribution Board (per phase isolation type), 230/415 volts, on surface/recess, complete with loose wire box/ cable termination box, terminal blocks, duly prewired with suitable size FRLS PVC insulated copper conductor upto terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, interconnections, blanking plates, phosphatized and powder painted including earthing etc. as required. (But without MCB/ RCCB/isolator). 2+4 way, SPN Double Door type, IP 43
Supplying and fixing following way, single/ three pole and neutral, pre-wired, sheet steel, MCB Distribution Board (per phase isolation type), 230/415 volts, on surface/recess, complete with loose wire box/ cable termination box, terminal blocks, duly prewired with suitable size FRLS PVC insulated copper conductor upto terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, interconnections, blanking plates, phosphatized and powder painted including earthing etc. as required. (But without MCB/ RCCB/isolator). 8 Way, TPN, Double Door, Vertical type, IP 43
Supplying and fixing following way, single/ three pole and neutral, pre-wired, sheet steel, MCB Distribution Board (per phase isolation type), 230/415 volts, on surface/recess, complete with loose wire box/ cable termination box, terminal blocks, duly prewired with suitable size FRLS PVC insulated copper conductor upto terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, interconnections, blanking plates, phosphatized and powder painted including earthing etc. as required. (But without MCB/ RCCB/isolator). 12 Way, TPN, Double Door, Vertical type, IP 43
Supplying and fixing of following MCB/RCCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 A, 4P, RCCB
Supplying and fixing of following MCB/RCCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 A, 4P, RCCB
Supplying and fixing of following MCB/RCCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 A, DP, RCCB
Supplying and fixing of following MCB/RCCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 A, 4P, C Series MCB
Supplying and fixing of following MCB/RCCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. 32 A, 3P, C Series MCB
Supplying and fixing of following MCB/RCCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. 6-32A, 10kA, SP "C" Series MCB
Supply of pendant 4 feet 40 W LED luminaires, suspension upto 3.5 meter suitable for double high ceilings or as per site conditions including supply of SS suspension wire etc. as required (Make:-Crompton CAT No. LCLP54/Bajaj CAT No. BPTX 40W LED 4F or equivalent). Warm White
Supply of pendant 4 feet 40 W LED luminaires, suspension upto 3.5 meter suitable for double high ceilings or as per site conditions including supply of SS suspension wire etc. as required (Make:-Crompton CAT No. LCLP54/Bajaj CAT No. BPTX 40W LED 4F or equivalent). Cool White/CDL
Supply of 2 feet x 2 feet, 36 W recess mounted Special premium look LED luminaires etc. as required (Make:-Crompton- STELLUX-H, CAT No. LCTRH-36-CDL/WW or equivalent).
Supply of 2 feet x 2 feet, 36 W recess mounted LED luminaires etc. as required (Make:-Crompton CAT No. LCTLRN-36-FO-CDL/ Halonix CAT No. HLFPR22-03-36 CW-R or equivalent).
Supply of recess mounted 6W LED round adjustable down lighter with COB LED etc. as required (Make:-Bajaj CAT No. BRDCSL 6W WW or equivalent).
Supply of RGB LED strip along with drivers etc. as required.(Make:-Havells, FLEXION LED DIGITAL LED STRIP, CAT No. LHEHDNPNUN4F024 or equivalent).
Supply of recess mounted 12W LED round down lighter etc. as required (Make:-Bajaj CAT No. BPSLR 12W WW or equivalent )
Supply of 20 W extruded aluminium LED batten etc. as required (Make:-Bajaj CAT No. BCLSBAL 20 W CW or equivalent )
Supply of 18 W Surface mounting round LED downlighter etc. as required. (Make: Bajaj, Cat No. BGCML 18 W WH or equivalent)
Supply of 10 W Surface mounted bulkhead luminaire, IP 65 Protection etc. as required (Make: Bajaj, Cat No. BIBWP 10W LED or equivalent)
Supply of 80 W LED flood light luminaire, IP 66 protection etc. as required (Make: Bajaj, CAT No. BJFL 80W LED I or equiavlent)
Supply of 12 W, RGBW LED luminaire along with controller for façade lighting, IP 66 protection etc. as required. (Make: Wipro, CAT No. LF04-181-030-CC-XX or equiavlent)
Supply of 9W LED bollard in decorative Inverted Pyramid Tripod, IP 65 protection etc. as required.(Make: Bajaj, BLBMC 9W WW LED or equiavlent)
Supply of 25 W Decorative LED Wall light in Spherical Shape Polycarbonate diffuser & IP 65 Protection etc. as required.(Make: Bajaj, CAT No. BLWSP 25W NW LED or equivalent)
Supply of 45 W LED Post top made in die-cast aluminium housing with decorative clear opal acrylic diffuser and IP 65 protection etc. as required.(Make: Bajaj, CAT No. ARIAN, BGCT W4 LED WW or equivalent)
Supply of 18 W (2 feet) linear LED luminaire with IP 65 Protection etc. as required (Make:- Crompton LPFC-18-CDL /Bajaj CAT No. BIPC 20 W LED or equivalent )
Installation, testing and commissioning of pre-wired, all above LED luminaries etc. of all types (Surface/Recessed), complete with providing all supporting steel & structure accessories, cement concrete foundations wherever necessary etc. directly on recess/surface, including connection with 1.5 sq. mm FRLS PVC insulated, stranded, copper conductor, single core cable with steel flexible conduits and coupler and earthing etc. as required.
Supply, Installation, Testing and Commissioning of aesthetically designed decorative hot dipped galvanized mild steel step pole with grey powder finish of high 3.5 m to receive LED Post top including suitable strength CC foundations and bolts & nuts etc. as required.
Supply of 400 mm sweep, 1350 rpm wall mounted fan, having pull cord control for speed and oscillation suitable for 230 V/240 V 50 HZ, AC supply etc. as required.(Make: Havells, Model: Swing or equivalent))
Supply of 400 mm sweep, 1360 rpm Pedestal fan suitable for 230 V/240 V 50 HZ, AC supply etc. as required.(Make: Havells, Model: Trendy or equivalent)
Supply of 200 mm sweep, 1350 rpm domestic exhaust fans suitable for 230 V/240 V 50 HZ, AC supply etc. as required.(Make: Havells, Model: Ventilair DX or equivalent)
Supply of 450 mm, sweep 900 RPM heavy duty exhaust fan suitable for single phase 230 volt, 50Hz AC supply complete with motor, capacitor, louvers/shutters and all accessories etc. complete as required.(Make: Havells, Model: Turbo force or equivalent)
Installation, testing and commissioning of Wall mounted fan including providing all supproting and fixing accessories and connections etc. complete as required.
Installation of 200 mm sweep exhaust fan in the existing opening including making the holes to suit the size of the above fan making good the damage, connections, testing and commissioning etc. with 1.5 sq.mm PVC insulated copper conductor three core cable etc. complete as required.
Installation of 450 mm sweep exhaust fan in the existing opening including making the holes to suit the size of the above fan making good the damage, connections, testing and commissioning etc. with 1.5 sq.mm PVC insulated copper conductor three core cable etc. complete as required.
Supply, installation, testing & commissioning of 6 KVA ON Line UPS three phase incoming & 3 phase outgoing having IGBT rectifier & inverter, harmonics <5%, relay card, necessary software, battery back up of 15 mintues including maintanence free batteries, interconnecting cables, battery stand etc. complete as required as per technical specification.
Supply, installation, testing and commissioning of 400A, 36 kA, Ics=100%Icu, thermal magnetc release 4P MCCB with spreader terminals and extended rotary handles fixed on existing compartment of MV Panel including providing suitable rating Aluminium Busbar to connect with common busbar and to receive out going cables and making connections etc., complete as reqd.(Make: L&T, Model: DN3B-400D or equivalent)
LIGHTING & POWER PANEL Design, fabrication, assembling, supply, installation, testing and commissioning of cubicle type LT panels wall mounted suitable for 415 V 3 phase, 4 wire 50 Hz AC supply system fabricated in compartmentised design from CRCA sheet steel of 2 mm thick for frame work IP 42 and covers,3 mm thick for gland plates i/c cleaning and finishing complete 7 tank process for powder coating in approved shade, extendable type TPN aluminium alloy busbars of high condectivity, extended rotary handles, DMC/SMC busbar supports, entire panel shall have a common copper earthbar of size 25mm X 5 mm at the rear with 2 Nos. earth studs, solid connection from main busbar to switchgears with require size of aluminium busbar & control wiring FRLS insulated copper conductor cable, cable alleys, cable gland plates i/c accessrories as per specification and providing switchgears, metering instruments etc. for follwing panels. A. Incoming Feeder:- (i) 1 No of 125 Amps, 415V, 50 Hz On load manual change over switch along with following (ii) LED type ndicating Lamp with suitable rating MCB:- 1 Set (each set comprise of R,Y,B) (iii) Digital type 3 phase Multi function Meter with suitable rating of MCB & 3 Nos. of epoxy resin cast type CTs of 125/5 Amps, CL 1.0 ratings -1 Set. B. Busbar:- 415 V, 200 Amps, 4 Strip Aluminium Busbars with Heat shrinkable color coded insulation sleeves. C. Outgoing:- 10 Nos. (i) 10 Nos. of 63 Amps, 415V, 10 kA, 4 Pole MCB
AC Panel Design, Fabrication, Supply, Installation, Testing & Commissioning of cubicle type, totally enclosed, double door with sloped roof, Outdoor type (IP55 or higher), floor mounted, fully CRCA steel built feeder pillar fabricated in compartmentalised design made out of 2.0 mm thick CRCA sheet, duly powder coated in approved shade suitable for operation on 415 V, 3 phase , 4 wire, 50 Hz AC supply, TPN aluminium busbars of high conductivity, DMC/SMC busbar supports with bottom base channel made out of steel section of not less than 3mm thickness, entire panel shall have a common copper earthbar of size 25mm X 5 mm at the rear with 2 Nos. earth studs, solid connection from main busbar to switchgears with required size of aluminium busbar, suitable cement concrete foundation, control wiring with FRLS insulated copper conductor cables, cable alleys , cable gland plates, neoprene gaskets, terminal blocks etc to accommodate the following accessories etc. complete as required. Incomer : 200A, FP, 25kA MCCB with Thermal magnetic release having adjustable O/L & S/C protection - 01 No. Aluminium busbars of 250A rating Out going - 63 A, FP, 300 mA, RCCB - 6 Nos Space for 02 No. MCCB of 63 A rating Digital Ammeter with suitable ratio CTs - 01 set (for incomer) Digital Voltmeter - 01 sets (for incomer) LED Phase Indication lamp with control MCBs - 01 Set (for incomer)
Supply of following size of 1.1 KV grade, Armoured XLPE insulated PVC sheathed Aluminium conductor cable confirming to IS: 7098 part -I amended upto date. 3.5C x 300 sqmm
Supply of following size of 1.1 KV grade, Armoured XLPE insulated PVC sheathed Aluminium conductor cable confirming to IS: 7098 part -I amended upto date. 3.5C x 95 Sq.mm
Supply of following size of 1.1 KV grade, Armoured XLPE insulated PVC sheathed Aluminium conductor cable confirming to IS: 7098 part -I amended upto date. 3.5 C x 50 sqmm
Supply of following size of 1.1 KV grade, Armoured XLPE insulated PVC sheathed Aluminium conductor cable confirming to IS: 7098 part -I amended upto date. 4C x 16 sqmm
Supply of following size of 1.1 KV grade, armoured XLPE insulated PVC sheathed Copper conductor cable confirming to IS: 7098 part -I amended upto date. 4C x 10 sqmm
Supply of following size of 1.1 KV grade, armoured XLPE insulated PVC sheathed Copper conductor cable confirming to IS: 7098 part -I amended upto date. 3C x 6 sqmm
Supply of 110 mm (outer dia)/95mm (inner dia) size, ISI marked Double Walled Corrugated high density polyethylene pipe (DWC-HDPE) having corrugation on the outer wall confirming to IS 14930 Part-II complete with necessary fittings/couplers for jointing for protection of 1.1KV grade under ground cable complete etc., as required
Laying of one number of 110 mm Dia (outer dia) size of Double Wall Corrguated high density polyethylene pipe (DWC-HDPE) for protection of 1.1KV grade under ground cable direct in ground at a depth of 75 cm including excavation and refilling the trench and jointing the pipes etc., as required.
Laying of one number 3.5C x 300 Sq.mm PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size in the existing RCC/HUME/METAL/DWC pipe as required.
Laying of one number 3.5C x 300 Sq.mm XLPE insulated and PVC sheathed power cable of 1.1 kV grade of following size in the existing masonry open duct as required.
Laying & fixing of one No 3.5C x 300 Sq.mm XLPE insulated & PVC sheathed Aluminium/Copper Cable of 1.1 KV grade of following sizes on surface/ cable tray etc. as required.
Laying & fixing of one No XLPE insulated & PVC sheathed Aluminium/Copper Cable of 1.1 KV grade of following sizes on surface/ cable tray etc. as required. Upto 35 sqmm
Laying & fixing of one No XLPE insulated & PVC sheathed Aluminium/Copper Cable of 1.1 KV grade of following sizes on surface/ cable tray etc. as required. Above 35 sqmm & upto 95 sqmm
Supplying and making end termination with heavy duty type brass single compression gland and aluminium lugs for following size of XLPE insulated aluminium conductor cable of 1.1 kV grade as required. 3.5 x 300 sqmm
Supplying and making end termination with heavy duty type brass single compression gland and aluminium lugs for following size of XLPE insulated aluminium conductor cable of 1.1 kV grade as required. 3.5 x 95 sqmm
Supplying and making end termination with heavy duty type brass single compression gland and aluminium lugs for following size of XLPE insulated aluminium conductor cable of 1.1 kV grade as required. 3.5 C x 50 sqmm
Supplying and making end termination with heavy duty type brass single compression gland and aluminium lugs for following size of XLPE insulated aluminium conductor cable of 1.1 kV grade as required. 4 x 16 sqmm
Supplying and making end termination with heavy duty type brass single compression gland and copper lugs for following size of XLPE insulated copper conductor cable of 1.1 kV grade as required 4C x 10 sqmm
Supplying and making end termination with heavy duty type brass single compression gland and copper lugs for following size of XLPE insulated copper conductor cable of 1.1 kV grade as required 3C x 6 sqmm
Supply, fabricating and installing of following size of perforated Hot dipped-galvanised cable trays including horizontal and vertical bends, reducers, tees, cross members and other accessories as required duly suspended from the ceiling/wall with GI . Suspenders etc. as required. 150 mm width x 50 mm depth x 1.6 mm thickness
Supply, fabricating and installing of following size of perforated Hot dipped-galvanised cable trays including horizontal and vertical bends, reducers, tees, cross members and other accessories as required duly suspended from the ceiling/wall with GI . Suspenders etc. as required. 300 mm width x 50 mm depth x 1.6 mm thickness
Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long,G.l. tube, having single prong at top, with 85 mm dia 6 mm thick G.l. base plate along with 5 mtr GI Mast with base plate to be installed on top of the building including necessary CC foundations, foundation bolts & nuts with all accessories for installation, holes etc. complete as required.
Fixing of lightning conductor finial (single prong) with base plate including holes etc. complete as required.
Jointing G.I. tape (with another G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required.
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run)
Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, check nuts and spring washers etc. complete as required.
Earthing with GI earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal or coke and salt) as required.
Extra for using salt and charcoal for G.I or Copper plate earth electrode as required.
Providing and fixing 25 mm x 5 mm GI strip on surface or in recess for connections with clamping etc as required.
Providing and fixing 25 mm X 5 mm GI strip in 40 mm dia GI pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 6 SWG dia GI wire on surface or in recess for loop earthing along with existing surface/recessed conduit/submain wiring/cable as required.
Supply & installation of ceiling/wall mounted type Fire Exit LED double sided Signages of minimum 3Watts, 200 lumens including necessary mounting kits, inbuilt battery minimum 90 minutes backup, necessary mandatory signages as required.(Make: Bajaj, Model: BESL 03 LED DSD WBB Green or equivalent approved makes).
Supply, installation, testing and commissioning of 1200 mm size aluminium powder coated Air Curtain suitable for a openining height upto 03 mtr, operated on Single Phase, 230 V, 50 Hz AC supply, with cordless remote control, two speed control high & low, top suction, suitable for continuous operation etc. as required.(Make: Russell, model: Mode-Wind G1 or equivalent)
Supply, Installation, Testing And Commissioning of fully automatic stainless steel sensor operated optimum hand dryers with safety thermal cut-off , operated on Single Phase 230 +/- 10 V, 50 HZ power supply etc. complete as required (Jaguar make & Model: HDR-SAP-M99ACS or equivalent)
Supplying, installing, testing and commissioning of monoblock pumpset with mechanical seal, CI casing & impeller, Stainless/Carbon steel shaft connected to a TEFC induction motor of suitable rating, 220 +/- 10% volts, single phase, 50 Hz A.C. supply, complete with vibration isolators, base plate, Concrete pedestal, including providing controller panel with starter, level switches to start and stop the pump automatically at predecided levels of the water in the tank, provision of protection for dry run including wiring and thermal over load protection etc. complete as required. Min. Capacity - 80 LPM, Head upto 30 mtr, Power upto 2 HP (Make & Model: Mather & platt, MPMS 20HH or equivalent)
Supplying, Installation, Testing and commissioning of Solid waste handling capacity upto 35 mm Sewage submersible dewatering pumping sets of CI casing & impeller, SS motor body & shaft, IP 68 protection including with water level sensors for operating the pumps automatically including providing controller panel with starter, thermal protection and all accessories suitable for operation on 220 +/- 10% volts, single phase, 50 Hz. AC supply etc. as required. Min. Capacity 200 LPM; Head - upto 12 Mtr; Power upto 2 HP (Make & Model: Mather & platt, STS 80/18 or equivalent)
SH-II : HVAC SYSTEM Supply Installation, Testing & Commissioning of modular type Variable Refrigerant Flow Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), minimum two compressors for above 14 HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R 410 A Refrigerant, vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5. 22 HP Nominal Cooling Capacity
Supply, installation, testing and commissioning of following minimum capacity 4-way flow VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. 0.8 TR
Supply, installation, testing and commissioning of following minimum capacity 4-way flow VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. 1 TR
Supply, installation, testing and commissioning of following minimum capacity 4-way flow VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. 2.3/2.4 TR
Supply, installation, testing and commissioning of following minimum capacity 4-way flow VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. 2.8 TR
Supply, installation, testing and commissioning of following minimum capacity 4-way flow VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. 3.2 TR
Supply, installation, testing and commissioning of following minimum capacity 4-way flow VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. 4 TR
Supply, installation, testing and commissioning of following minimum capacity VRF High wall type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, cord less remote control, drain pan, necessary accessories etc., suitable for operation on 230 V ± 10%, 50 Hz, single phase AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. 1 TR
Supply, installation, testing and commissioning of following minimum capacity VRF High wall type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, cord less remote control, drain pan, necessary accessories etc., suitable for operation on 230 V ± 10%, 50 Hz, single phase AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. 2 TR
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : [NOTE:- 1)The Copper Piping & Piping Circuit should be with Minimum Number of joints, which shall be attained by : (i) Using One End Expanded Tubes (ii) Bending the tubes instead of using elbow joints wherever 90 degree bending is required. (2) Piping should be routed at site in such a manner, that brazed joints in the refrigeration piping are kept to a minimum. (3) The makes of tube fittings shall be same as that of tubes. (4) The thickness of fittings used shall be same as that of the pipe. (5) Upto 15.86 mm (OD) with tube thickness shall be 1.2 mm and Soft drawn. (6) Above 15.86 mm (OD) shall be Hard drawn. (7) Abobe 28.58 mm (OD) with tube thickness shall be 1.62 mm. For Suction line of suitable dia. of various sizes with 19 mm thick insulation as per design of OEM recommendations
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : [NOTE:- 1)The Copper Piping & Piping Circuit should be with Minimum Number of joints, which shall be attained by : (i) Using One End Expanded Tubes (ii) Bending the tubes instead of using elbow joints wherever 90 degree bending is required. (2) Piping should be routed at site in such a manner, that brazed joints in the refrigeration piping are kept to a minimum. (3) The makes of tube fittings shall be same as that of tubes. (4) The thickness of fittings used shall be same as that of the pipe. (5) Upto 15.86 mm (OD) with tube thickness shall be 1.2 mm and Soft drawn. (6) Above 15.86 mm (OD) shall be Hard drawn. (7) Abobe 28.58 mm (OD) with tube thickness shall be 1.62 mm. For Discharge line of suitable dia. of various sizes with 19 mm thick insulation as per design of OEM recommendations
Supply, Installation, Testing and Commissioning of copper Y- Joints/Refnet Joints suitable size for suction and discharge line of above VRF System etc complete as required. for indoor Units
Supply, Installation, Testing and Commissioning of copper Y- Joints/Refnet Joints suitable size for suction and discharge line of above VRF System etc complete as required. for outdoor units
Supply, installation, testing and commissioning of Protective layer for outdoor area both suction and discharge copper piping of various sizes with woven fibre glass cloth wrapped around copper piping tubular insulation and finised with PVAC based high strength glue with anti fungal property of approved colors.
Supply, installation, testing and commissioning of UPVC heavy duty Drain piping complete with fittings, supports etc. and duly insulated with 9 mm thick closed cell nitrile rubber tube insulation etc. as required. 25 mm dia
Supply, installation, testing and commissioning of UPVC heavy duty Drain piping complete with fittings, supports etc. and duly insulated with 9 mm thick closed cell nitrile rubber tube insulation etc. as required. 32 mm dia
Supply, installation, testing and commissioning of UPVC heavy duty Drain piping complete with fittings, supports etc. and duly insulated with 9 mm thick closed cell nitrile rubber tube insulation etc. as required. 40 mm dia
Supply, installation, testing and commissioning of Central Controller - DCC for the above VRF System at Operators room as directed etc. complete as required.
Providing and fixing transmission/control/communication wiring of 2 core x 1.5 sq.mm copper conductor non-polarity shielded wire in 25 mm ISI Marked PVC conduits between outdoor-outdoor / indoor-indoor / outdoor-indoor and remote control unit etc. including connections and fixing accessories as required.
Supply, installation, testing and commissioning of 22 gauage factory fabricated GSS sheet metal confirming to IS: 277 ducting as per IS 655-2006 for both Supply and Return air as per ducting specifications and with suitable supports using MS angles, channels, rods, anchor bolts, etc to roof /truss and as per specifications incuding sizing of ducts.
Supply, fixing, testing and commissioning of powder coated extruded aluminium section exhaust air grille with bird screen rain protection etc. complete as required with aluminium frame work.
Supply, fixing, testing and commissioning of powder coated extruded aluminium section fresh air grille with extruded aluminium volume control damper, bird screen, rain protection etc. complete as required with aluminium frame work.
Supply, fixing and commissioning of powder coated extruded aluminium grilles complete with black anodized extruded aluminum VCD, nuts, bolts, screws etc. as per approved drawings and specifications. Supply air grilles with volume control damper.
Supply, fixing and commissioning of powder coated extruded aluminium grilles complete with black anodized extruded aluminum VCD, nuts, bolts, screws etc. as per approved drawings and specifications. Return air grilles without volume control damper
Supply of premium quality, On-line, SS 304 grade stainless steel body water cooler cum hot & normal water dispenser of capacity min. 40 ltrs along with inbuilt 5 stages RO + UV based water purifier (25LPH) including all accessories and one year comprehensive warranty etc. complete as required.
SH-III : FIRE ALARM & DETECTION SYSTEM AND FIRE HYDRANT SYSTEM Supply and installation of Intelligent, Analog addressable type photo electric Smoke cum Heat Detector with standard base including all accessories etc. complete as required.(Make: Edwards, Model: SIGA-PHD+SB)
Supply and installation of Intelligent, Analog addressable type photo electric smoke detector with standard base including all accessories etc. complete as required.(Make & Model: Edwards SIGA - PD + SB)
Supply and installation of Intelligent, Analog addressable type photo electric Heat Detector with standard base including all accessories etc. complete as required.(Make: Edwards, Model: SIGA-HRD+SB)
Supply, Installation of Response Indicator suitable for Intelligent, Analog addressable type photo electric detector including all accessories etc. complete as required. (Make: Edwards, Model: SIGA-LED)
Supply and installation of Addressable type manual call pull stations including all accessories etc. complete as required.(Make & Model: Edwards SIGA 271)
Supply and installation of addressable type Sounder cum Strobe including all accessories etc. complete as required. (Make & Model: Edwards G1RF - HDVM)
Supply and installation of addressable type Fault Isolater Module including all accessories etc. complete as required.(Make & Model: Edwards SIGA - IM)
Supply and installation of addressable type Control module including all accessories etc. complete as required.(Make & Model: Edwards SIGA - CC1)
Supply and installation of addressable type Control relay module for shutting down indoor/outdoor units of VRF AC System including all accessories etc. complete as required.(Make & Model: Edwards SIGA - CR)
Supply and installation of addressable fire telephone jack including all accessories etc. complete as required.(Make & Model: Edwards 6833-4, SIGA-CR/CC1)
Supply and installation of fire telephone handset including all accessories etc. complete as required.(Make & Model: Edwards 6830-3)
Supply and installation of Dual Signature Driver Controller including all accessories etc. complete as required.(Make & Model: Edwards - 3-SDDC1)
Supply and installation of Repeator Fire Panel including all accessories etc. complete as required.(Make & Model: Edwards - 3 LCDANN)
Supply and laying of 2 X 1.5 Sq.mm PVC insulated (fully red coloured) , FRLS, Stranded Copper Armoured cable on surface/conduit/open duct/ with all accessories including terminations and testing etc. complete as required.
Supplying and fixing of 25 mm size of ISI marked steel conduits along with accessories on surface/ recessed including cutting the wall and making good the same in case of recessed conduit etc. complete as required.
Interfacing the above all installations with existing Fire control Panel of model EDWARDS EST 3 including testing, commissioning & programming of the complete fire alarm system etc. complete as required.
Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts,gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports,anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. 150 mm dia
Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts,gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports,anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. 100 mm dia
Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts,gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports,anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. 80 mm dia
Providing, laying, testing & commissioning of 'C' class heavy duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts,bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 100 mm dia
Providing, laying, testing & commissioning of 'C' class heavy duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts,bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 80 mm dia
Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with cap and chain as required
Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with cap and chain as required :
Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 16 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required : 150 mm dia
Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 16 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required : 100 mm dia
Supplying and fixing 63 mm dia, 15 mtr. long RRL hose pipe with 63 mm dia Male and Female Gun metal couplings duly bound with GI wire, rivets etc. coforming to IS 636 (type-A) as required.
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required: i) 30 mtr, 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 ii) 20 mm nominal internal dia gun metal globe valve & nozzle. iii) Drum and brackets for fixing the equipmets on wall. iv) Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required. i) 4 way - 150 mm dia M.S. Pipe
Supplying and fixing orifice plate made of 6 mm. thick stainless steel with orifice of required size in between flange and landing valve of internal hydrant to reduce pressure to working pressure of 3.5 kg/cm2 complete as per specifications as required.
Providing, installation, testing and commissioning of dual plate wafer type non-return valve PN 16 of CI body of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc. as required. i) 150 mm dia
Supplying and fixing of hose cabinet of size 900 mm x 600 mm x 500 mm made of 2mm thick MS sheet with 6 mm thick glazed glass doors with necessary locking arrangement suitable to accommodate internal/external hydrant, 2 nos 15 Meter long 63 mm dia hose pipe, 1 no branch pipe, mounted on wall duly painted with post office red externally and white internally with synthetic enamel paint complete in all respect, for internal hydrant as required.
Supplying and fixing of hose cabinet of size 900 mm x 600 mm x 500 mm made of 2mm thick MS sheet with 6 mm thick glazed glass doors with necessary locking arrangement suitable to accommodate internal/external hydrant, 2 nos 15 Meter long 63 mm dia hose pipe, 1 no branch pipe, with mounted on standard height Cement Concrete pedestal, duly painted with post office red externally and white internally with synthetic enamel paint complete in all respect, for external hydrant as required.
Providing and fixing Carbon-di-oxide fire extinguishers consisting of welded M.S cylindrical body,squeeze lever discharge valve fitted with internal dischargetube, 30cms long high pressure discharge hose, discharge nozzle, suspension bracket, finished externally with red enamel paint and fixed to wall with brackets with rawl plug/dash fasteners complete with initial charging (In each FHC). Capacity 4.5kg.(IS : 2878)
Providing and fixing Mechanical foam type (ISI marked) fire extinguishers consisting of welded M.S. cylindrical body squeeze lever discharge valve 30 cm long high pressure discharge hose, discharge nozzle suspension bracket , finished externally with red enamel paint and fixed to wall with brackets complete with initial charging. 9 litres capacity. (IS : 10204)
Providing and fixing Water CO2 (ISI marked) extinguishers including all accessories as per IS specification. (IS : 940 - 1989) with wall bracket, CO2 catridge , initial filling etc complete as required. Capacity 9 litres. (IS : 940)
Providing and fixing ABC type (stored pressure) extinguisher as per IS : 13849 - 1993 consisting of welded MS cylindrical body ,with discharge hose, discharge valve, suspension bracket, initial filling etc complete as required. Capacity 6 Kg. (IS: 13849)
LAN and IT System works Supplying and drawing following pair 0.5 mm. dia PVC insulated PVC sheathed annealed tinned copper conductor, unarmoured telephone cable in existing surface/ recessed steel conduit/ raceways etc as required. 2 pair(Make like ANCHOR/HAVELLS/D LINK/DIGISOL etc)
Supplying and laying 10 pair 0.5 mm. dia PVC insulated PVC sheathed copper conductor/ cable tray, as required. (Make like ANCHOR/HAVELLS/D LINK/DIGISOL etc )
Supply & installation of 10 pair MDF Box in sheet steel enclosure of 1.6 mm thickness, including Krone type connector, connections, testing & commissioning etc. as required along with 10-Pair Krone Module(Standard Make)
Supplying and laying 100 pair 0.5 mm. PVC insulated PVC sheathed copper conductor, armoured telephone cable on surface/cable tray as required.(Make Like Polycab,Finolex etc.)
Supply & installation of 100 pair MDF Box in sheet steel enclosure of 1.6 mm thickness, including Krone connector, connections, testing & commissioning etc. as required along with 100-Pair Krone Module(Standard Make)
Supplying, installation, testing & commissioning of RJ-11 flush mounted information outlets wired according to relevent IS standard with face plate in the existing modular G.I. box complete as required. Single outlet in one plate (Make DLINK, Legrand etc.)
Supplying, installation, testing & commissioning of RJ-45 flush mounted information outlets wired according to relevent IS standard with face plate in the existing modular G.I. box complete as required. Single outlet in one plate (Make DLINK, Legrand etc.)
Supply, drawing, testing & commissioning of 4 Pair CAT-6 Non-Plenum UTP cable of 24 AWG solid copper conductors in existing surface/ recessed steel conduit/ raceways etc as required. complete as required.(Make like ANCHOR/HAVELLS/D LINK/DIGISOL etc )
Supply, installation, testing and commissioning of Overhead projector with following components / equipments as required along with screen Overhead Projector : Overhead projector suitable to use with Laptop / Computer with following minimum configuration. Colour light output of 3000 Lumens(high mode lamp) and 2400 Lumens (Standard mode lamp), Screen coverage - 40 to 300 Inch, RGB Resolution of minimum 1024 x 768 Pixels, Colour system of PAL,SECAM, NTSC3/4, with Video, Audio, USB, Network inputs, of Model - SONY VPL-DX15 or equivalent. Laptop with Licenced preloaded Windows and Microsoft office software with Word, Excel, Powerpoint, Access, Outlook, Adobe, Licenced Antivrus software etc. complete as required of following configuration. G8, i7 processor, 1 TB hard disk, Ram 8 GB etc Make Like Dell,hp Lenova etc
R R ASSOCIATES
Sudhakara Infratech Private Limited
M/s.Gopal Teknocon Private Limited
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .