Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹49.0 LAdmitted-Finance | -0.01% | ₹49.0 L | L1 | Admitted-Finance |
| 2 | L2₹49.5 L+₹49,489.97 (1.01%)Admitted-Finance | +1.00% | ₹49.5 L+₹49,489.97 (1.01%) | L2 | Admitted-Finance |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
10 Aug 2026, 6:00 pmClosed
EO Nagar Palika, Itawa
EO Nagar Palika, Itawa
Fixing of LED Lights in all Wards at Nagar Palika area.
2026_DLB_580963_1
NIT No. 07/2026-27 (No. 3223-27)
Open Tender
Electrical Works
Percentage
90 days
Kota
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
EO Nagar Palika, Itawa
₹98,000
Yes
20 Aug 2026
3 Aug 2026
12 Aug 2026
3 Aug 2026
10 Aug 2026
3 Aug 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supplying and drawing of XLPE insulated LT Aerial bunched Aluminium conductor cable confirming to IS 14255/1995 and IS 398 (Pt-4)/ 1994 and as per Discom Specs. on existing cross arms through I hook with all necessary T&P required including binding and twisting etc. complete in all respect as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR. 1× 25 sq. mm. + 1×25 sq. mm. (insulated) | 5,195 | RM | 65 | ₹3,37,675 |
| 2 | Supply and fixing of following LT Supporting accessories with nut bolt & Clamps made out as per standard Discom's specifications with two coats of Red oxide and two coats of Aluminium paint etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR LT cross arm 600 mm long with clamp | - | Nos. | 472 | - |
| 3 | Supply and fixing of porcelain shackle insulator as per IS:1443 1979 suitable for working on 1100 volts including hot dipped GI accessories and heavy duty hardwares etc as required as per PWD / DISCOM specification. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR. 100mm×110mm | - | Nos. | 122 | - |
| 4 | Providing & Fixing of Street light bracket made out from following size of ' B ' class , Medium class G.I. Pipe confirming to IS : 1239 P-1 (2004) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR. 32 mm Dia. | - | Nos. | 761 | - |
| 5Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass cover and secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driver Efficiency >85% ,THD(I) <10% Humidity 10% to 90% RH Working Temp 5C to 45C. driver current <750mA. The luminaire shall be BIS certified and Trade mark certified. | |||||
| 5.01 | Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintained, CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved / Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced. OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR. | - | - | - | - |
| 5.02 | LED Street Light fixture with Minimum lumen output 3700 lm | - | Nos. | 3,454 | - |
| 5.03 | LED Street Light fixture with Minimum lumen output 5600 lm | - | Nos. | 4,249 | - |
| 6 | P&F of IP 55 protected light controlled switch based on infrared sensing and daylight with built-in overload protection, timer to switch OFF at preselected time. Switch shall have 7 day power backup without hampering of preset time and override facility for maintenance purpose. Suitable for 15 kW load (three phase) including contactor, MCB, cable glands, terminal block and locking arrangement (RUIDP ISOR 2017, 58.15.2). | 36 | Nos. | 20,352 | ₹7,32,672 |
| 7 | Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed unarmoured copper cable confirming to IS:1554 (Part-I) / IS:7098 (Part-I) of 1.1 kV with electrolytic grade copper made of copper rods confirming to IS:613-1964, of purity >99.7%, inner/outer sheath confirming to IS:5831, in existing RCC / Hume / Stoneware / PVC pipe, open duct, cable trench or cable tray (with cable tie), including testing etc. as required, of following size. OEM must have its own in-house NABL accredited laboratory for testing procedure as per IS:10810. For additional technical parameters of product / work, refer Annexure 'A' attached with this BSR. 1.5 Sq. mm, 3 Core. | 3,000 | RM | 112 | ₹3,36,000 |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.09 MB
BOQ_1032407.xls
BOQ • 0.24 MB
Corrigendum_Conditions.pdf
PDF • 1.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .