Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance NO 13 VSAN ELECTRICALS AND SENSORS SAI NAGAR PORUR GARDEN PHASE 1 VANAGARAM CHENNAI VANAGARAM | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
Refer Docs
Closing Date
2 Nov 2020, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Manideep Tumu
FACT PD Administrative Office,Udyogamandal, Kochi -683501. Phone - 2568635.
Procurement of Water Flowmeter
2020_FACT_588375_1
MM/132/E22177
Open Tender
Miscellaneous Goods
Supply
Udyogamandal
As per attached tender document
6 documents required · 6 mandatory
₹0
Exempted
3 Nov 2020
5 Oct 2020
3 Nov 2020
5 Oct 2020
2 Nov 2020
5 Oct 2020
5 Oct 2020 - 26 Oct 2020
90 days
DN 50; 150 # Water Flowmeter with Totaliser Type : Woltman type Bulk water flow meter Standards :Conforming to ISO4064 Class B Minimum Flow,QMin : 0.45 M3/Hr Nominal Flow,QNor : 15 M3/Hr Maximum Flow,QMax : 30 M3/Hr Meter Size : DN50 or 2 ANSI Flange Size and Pressure Rating : DN50 or 2 ANSI and PN16 or Class 150 # Measuring Dial Type : Inferential Dry Dial Measuring Dial Reading : Straight Reading in Litres or Kilo Litres Measuring Dial Coupling with wetted parts : Magnetically Coupled Flow Direction : Horizontal Flow Accuracy/ Repeatability : ± 2% of span or better Characteristics : Linear Meter Housing M.O.C. : Die Cast Aluminium or Better M.O.C. of Fastners : Stainless Steel SS 304 or Better M.O.C. of Body : Cast Iron with Flanged Ends with epoxy coating or Better Operating Temperature : 18 to 60 Deg.C
DN 80; 150 # Water Flowmeter with Totaliser Type : Woltman type Bulk water flow meter Standards : Conforming to ISO4064 Class B Minimum Flow,QMin : 1.2 M3/Hr Nominal Flow,QNor : 40 M3/Hr Maximum Flow,QMax : 80 M3/Hr Meter Size : DN80 or 3 ANSI Flange Size and Pressure Rating : DN80 or 3 ANSI and PN16 or Class 150 # Measuring Dial Type : Inferential Dry Dial Measuring Dial Reading : Straight Reading in Litres or Kilo Litres Measuring Dial Coupling with wetted parts : Magnetically Coupled Flow Direction : Horizontal Flow Accuracy/ Repeatability : ± 2% of span or better Characteristics : Linear Meter Housing M.O.C. : Die Cast Aluminium or Better M.O.C. of Fastners : Stainless Steel SS 304 or better M.O.C. of Body : Cast Iron with Flanged Ends with epoxy coating or better Operating Temperature : 18 to 60 Deg.C
DN 100; 150 # Water Flowmeter with Totaliser Type : Woltman type Bulk water flow meter Standards : Conforming to ISO4064 Class B Minimum Flow,QMin : 1.8 M3/Hr Nominal Flow,QNor : 60 M3/Hr Maximum Flow,QMax : 120 M3/Hr Meter Size : DN100 or 4 ANSI Flange Size and Pressure Rating : DN100 or 4 ANSI and PN16 or Class 150 # Measuring Dial Type : Inferential Dry Dial Measuring Dial Reading : Straight Reading in Litres or Kilo Litres Measuring Dial Coupling with wetted parts : Magnetically Coupled Flow Direction : Horizontal Flow Accuracy/ Repeatability : ± 2% of span or better Characteristics : Linear Meter Housing M.O.C.: Die Cast Aluminium or Better M.O.C. of Fastners : Stainless Steel SS 304 or better M.O.C. of Body : Cast Iron with Flanged Ends with epoxy coating or better Operating Temperature : 18 to 60 Deg.C
DN 200; 150# Water Flowmeter with Totaliser Type : Woltman type bulk water flow meter Standards : Conforming to ISO4064 Class B Minimum Flow,QMin : 7.5 M3/Hr Nominal Flow,QNor : 250 M3/Hr Maximum Flow,QMax : 500 M3/Hr Meter Size : DN200 or 8 ANSI Flange Size and Pressure Rating : DN200 or 8 ANSI and PN16 or Class 150 # Measuring Dial Type : Inferential Dry Dial Measuring Dial Reading : Straight Reading in Litres or Kilo Litres Measuring Dial Coupling with wetted parts : Magnetically Coupled Flow Direction : Horizontal Flow Accuracy/ Repeatability : ± 2% of span or better Characteristics : Linear Meter Housing M.O.C. : Die Cast Aluminium or Better M.O.C. of Fastners : Stainless Steel SS 304 or better M.O.C. of Body : Cast Iron with Flanged Ends with epoxy coating or better Operating Temperature : 18 to 60 Deg.C
DN 300 ;150 # Water Flowmeter with Totaliser Type : Woltman type Bulk water flow meter Standards :Conforming to ISO4064 Class B Minimum Flow,QMin : 18 M3/Hr Nominal Flow,QNor : 600 M3/Hr Maximum Flow,QMax : 1200 M3/Hr Meter Size : DN300 or 10 ANSI Flange Size and Pressure Rating : DN300 or 10 ANSI and PN16 or Class 150 # Measuring Dial Type : Inferential Dry Dial Measuring Dial Reading : Straight Reading in Litres or Kilo Litres Measuring Dial Coupling with wetted parts : Magnetically Coupled Flow Direction : Horizontal Flow Accuracy/ Repeatability : ± 2% of span or better Characteristics : Linear Meter Housing M.O.C. : Die Cast Aluminium or Better M.O.C. of Fastners : Stainless Steel SS 304 or better M.O.C. of Body : Cast Iron with Flanged Ends with epoxy coating or better Operating Temperature : 18 to 60 Deg.C.
vsan electricals and sensors
stage.html
html • 0.02 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .