Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.7 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹9.0 L+₹10,510 (1.19%)Rejected-Finance 201 JITENDRA LODGE BUILDING 20 NEW JAGNATH PLOT RAJKOT | RAJKOT | RAJKOT | GUJARAT | L2 | Rejected-Finance NOT L1 |
Tender Value
₹9 L
EMD Value
₹18,000
Closing Date
31 Aug 2021, 6:00 pmClosed
AGE I A Jamnagar
INFANTRY LINES JAMNAGAR
REPAIRS / REPLACEMENT OF INTERNAL WIRING, LIGHT FITTINGS, FIXTURES AND CONNECTED ITEMS AT OFFRS MD ACCN AT INF LINES JAMNAGAR
2021_MES_465146_1
8829
Open Tender
Electrical and Maintenance Works
Item Wise
120 days
Jamnagar
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
AGE I ARMY JAMNAGAR
₹18,000
15 Sept 2021
4 Aug 2021
1 Sept 2021
5 Aug 2021
31 Aug 2021
10 Aug 2021
Amount
Taking down carefully aluminum /copper point wiring (light, fan, switch & power) complete including fittings such as switches, ceiling rose, pendent, by unscrewing from board ,out let box, fitting and fixture such as bulk head fitting, sketch fittings and making good the disturbed rurfaces of walls floors etc complete all as specified and directed by Engr-in-Charge.
Taking down old MCB, DBs/main switch of any size complete all as specified and directed by Engr-in-Charge.
Taking down service/sub main wire of any size fixed in any position , complete all as specified and directed by Engr-in-Charge.
M&L for point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits),with multi stranded copper conductor 1.5 sq mm nominal cross sectional area, single core, pvc insulated and unsheathed FRLS cable 1100 volts grade, ISI-694 marked with valid CML No in and including medium grade, PVC Concealed conduit of dia not less than 20mm and conduit accessories concealed in wall, ISI marked with valid CML No (IS-9537-1983 for conduits and IS: 3419:1976 for conduit accessories), with mild steel/pressed steel sunken boxes (with earth duly) duly painted with two coats of anticorrosive paint over a coat of red oxide primer internally and two coats of black bituminous paint over a coat of red oxide primer externally, covered with 3mm thick hylam laminated sheet cover for fixing of switches, sockets etc including PVC insulated multi stranded copper conductor 1.5 sqmm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dully complete all as specified and directed by Engr-in-Charge at site for the following :
One light/ Fan point controlled by one way switch.
One Bell point controlled by one switch bell push
One light point controlled by two - 2 way switches for stair case.
One 5 Amps switch socket combination on independent board.
One 5 Amps socket on same board with other switches.
All as per item No-4 here in above but 2.5 Sqmm stranded copper conductor and independent board for 15 Amps switch/socket point complete all as specified and directed by Engr-in-Charge.
M&L for point wiring with stranded copper conductor 1.5. Sqmm 1100 Volts grade FRLS PVC insulated and unsheathed including ISI marked PVC casing capping of required sizes as indicated including all accessories, copper conductor cable 1.5 Sqmm insulated and unsheathed PVC cables as earth wire, trminal boxes closed recossed type. PVC Plastic board all as required complete all as specified and directed by Engr-in-Charge for the following :-
One light/ Fan point controlled by one way switch.
One Bell point controlled by one switch bell push
One light point controlled by two - 2 way switches for stair case.
One 5 Amps switch socket combination on independent board.
One 5 Amps socket on same board with other switches.
All as per item No-6 here in above but 2.5 Sqmm stranded copper conductor and independent board for 15 Amps switch/socket point complete all as specified and directed by Engr-in-Charge.
S&F in replacement of switch piano flush type single pole one way 5 Amps 230 V complete all as specified and directed by Engr-in-Charge.
S&F in replacement of switch piano flush type single pole two way 5 Amps 230 V complete all as specified and directed by Engr-in-Charge.
S&F in replacement of switch socket out let 3 pin 5 Amps flush type 230 Volts multipurpose complete all as specified and directed by Engr-in-Charge.
All as per item No-10 above but 5 Amps and 15 Amps multipurpose ( 3 Pin 15 Amps and one pin 5 Amps controlled by one switch.) complete all as specified and directed by Engr-in-Charge.
S&F in replacement of socket out let 3 pin, 5 Amps, 230 Volt multipurpose flush piano type complete all as specified and directed by Engr-in-Charge.
S&F in replacement of fan regulator Electronic Step type (min 5 steps) 2module, 100/120W ISI marked by removing old u/s resistance type fan regulator including necessary connection in existing laminated switch board by making necessary holes etc complete all as specified and directed by Engr-in-Charge.
S&F in replacement of Bell Ding Dong AC 230 volts type single pole as directed complete all as specified and directed by Engr-in-Charge.
S&F in replacement of switch Bell Push botton type 5 Amps single pole one way complete all as specified and directed by Engr-in-Charge.
S&F in replacement of lamp holder insulated body with back plate for battern fittings complete all as specified and directed by Engr-in-Charge.
Supply & Fixing in repairs LED Batten fittings , 5 Watt with CCT 6500 K and Lumens should not less than 500 lm with flexible wire connecting to ceiling rose complete all as specified and directed by Engr-In-Charge. (Make :- Model Wipro Garnet 5W , D530565 of Wipro, or Eq model of Philips/Osram ).
Supply & Fixing in repairs extruded aluminium LED Batten fittings with Decorative end caps of 9/10 Watt with CCT 6500 K and Lumens should not less than 900 lm with flexible wire connecting to ceiling rose complete all as specified and directed by Engr-In-Charge. (Make:- Jaquar CAT PART NO. LGLZ01X010XC , or Eq model of Philips/Bajaj ).
Supply & Fixing in repairs extruded aluminium LED Batten fittings with Decorative end caps of 18/ 20 Watt with CCT 6500 K and Lumens should not less than 2000 lm with flexible wire connecting to ceiling rose complete all as specified and directed by Engr-In-Charge. (Make:- Jaquar CAT PART NO. LGLZ01X020XC , or Eq model of Philips / Bajaj ).
S&F in replacement of Post top lattern light fitting die cast aluminium graphite grey powder coated spigot, acrylic clear diffuser, opal acrylic diffuser provided at LED area to minimize glare for LED System wattage 40W with LED Color temperature 3000k + 300k complete with accessories including wiring with copper wire of 2.5sqmm from junction box to fitting complete all as specified and directed by Engr-in-Charge. Make: BGCT W4 LED WW of Bajaj or eqvt in wipro/philips
Supply & Fixing in replacement of Decorative, wall mounting, chrome finish fixture with opal glass diffuser suitable for 7.5 W A60 LED filamnet lamp E27 base. Cat part No LHFOAJD1TZ1C060 of make Havells or equivalent Bajaj/Halonex/Surya incl PVC gutties and flexible wire and connecting to ceiling rose complete all as specified and directed by Engr-in-Charge.
Supply & Fixing in replacement of Decorative, wall mounting, brushed nickel finish fixture with opal glas diffuser suitable with 9W LED lamp B22 base. Cat part No LHFOAJE1TN1I060 of make Havells or equivalent Bajaj/Halonex/Surya incl PVC gutties and flexible wire and connecting to ceiling rose complete all as specified and directed by Engr-in-Charge.
Supply & Fixing in replacement of 20watt LED wall light fitting made up of opal glass warm white color for living & bedroom including 2.5 KV surge protector complete all as specified and directed by Engr-in-Charge.
Supply& Fixing in replacement of 3watt LED Bedside light fitting for bedroom including 2.5 KV surge protector complete all as specified and directed by Engr-in-Charge.
S&F in replacement of ceiling rose surface backelet ISI marked , 2 to 3 terminal complete all as specified and directed by Engr-in-Charge.
S&F DB sheet metal enclosure SPN 4 way Double door with 200Amp rated bus Bar 240V complete all as specified and directed by Engr-in-Charge. Make:Indoasian /Havells/C&S
All as per item No-26 above but SPN 8 way Double door with 200Amp rated bus Bar 240V complete all as specified and directed by Engr-in-Charge. Make:Indoasian /Havells/ABB
All as per item No-26 above but SPN 12 way Double door with 200Amp rated bus Bar 240V complete all as specified and directed by Engr-in-Charge. Make:Indoasian /Havells/ABB
S&F MCB SPN 10 to 40 Amps and rupturing capacity 10 KA complete all as specified and directed by Engr-in-Charge. Make:Indoasian /Havells/ABB
S&F MCB single pole 5 to 32 Amps and rupturing capacity 10 KA complete all as specified and directed by Engr-in-Charge. Make:Indoasian /Havells/ABB
S&F DB sheet metal enclosure 4 way TPN Double door with 200Amp rated bus Bar complete all as specified and directed by Engr-in-Charge. Make:Indoasian /Havells/ABB
S&F DB sheet metal enclosure 8 way TPN Double door with 200Amp rated bus Bar complete all as specified and directed by Engr-in-Charge. Make:Indoasian /Havells/ABB
Supply and Fix for MCB TPN, 4 pole 40 Amps 415 Volts and repturing capacity 10 KA complete all as specified and directed by Engr-in-Charge. complete. Make:Indoasian /Havells/ABB
Supply and Fix for MCB TPN, 4 pole 63 Amps 415 Volts and repturing capacity 10 KA complete all as specified and directed by Engr-in-Charge. Make:Indoasian /Havells/ABB
M&L for sub main wiring with two runs of 2.5 Sqmm single core FRLS PVC unsheathed and insulated 1100 Volt grade/Multi stranded copper conductor drawn through PVC conduit & accessories fixed an surface of walls, ceiling floors etc including one run of PVC insulated and unsheathed cable of copper conductor of 2.5 Sqmm single core as earth continuity wire complete all as specified and directed by Engr-in-Charge. Note :- Two runs of single core PVC insulated unshethed cables and one run of earth continuity conductor incl conduit will be messured and paid as one unit length only. Make:Havells/Finolex/Polycab
M&L for sub main wiring with two runs of 4.00 Sqmm single core FRLS PVC unsheathed and insulated 1100 Volt grade/Multi stranded copper conductor drawn through PVC conduit & accessories fixed an surface of walls, ceiling floors etc including one run of PVC insulated and unsheathed cable of copper conductor of 4.00 Sqmm single core as earth continuity wire complete all as specified and directed by Engr-in-Charge. Note :- Two runs of single core PVC insulated unshethed cables and one run of earth continuity conductor incl conduit will be messured and paid as one unit length only. Make:Havells/Finolex/Polycab
M&L for sub main wiring with two runs of 6.00 Sqmm single core FRLS PVC unsheathed and insulated 1100 Volt grade/Multi stranded copper conductor drawn through PVC conduit & accessories fixed an surface of walls, ceiling floors etc including one run of PVC insulated and unsheathed cable of copper conductor of 6.00 Sqmm single core as earth continuity wire complete all as specified and directed by Engr-in-Charge. Note :- Two runs of single core PVC insulated unshethed cables and one run of earth continuity conductor incl conduit will be messured and paid as one unit length only. Make:Havells/Finolex/Polycab
S&F LED light fitting, 1x12 w bulk head luminaries, complete with all accessories and including connection up with twin core twisted flesible copper conductor cable with suitable size of 230v, 50 HZ complete all as specified and directed by Engr-in-Charge. MAKE: CG LBHN10CDL / Philips/Bajaj
Supply and fixing Plastic body exhaust fan 225 mm sweep AC, 240 volts fixed as per manufacturer instruction, connecting with and including 1.5 Sqmm copper conductor, PVC insulated and PVC sheathed three core cable complete all as specified and directed by Engr-in-Charge. Make :Orient / Crompton/ Havells/Bajaj/Khaitan
S&F in replacement of recess mounting LED panel 12 W 160mm X 160mm luminaire white powder coated CRCA housing with LEDs seamless front frame with flat white high transmission acrylic cover complete all as specified and directed by Engr-in-Charge. Make: Bajaj/Wipro/CG
S&F PVC Plastic switch board of size 8"x10" including shifting of switch, sockets, regulator etc complete all as specified and directed by Engr-in-Charge.
S&F in repairs PVC Plastic switch board of size 6"x8" including shifting of accessories switch, sockets, regulator etc complete all as specified and directed by Engr-in-Charge.
S&F PVC Plastic switch board of size 7"x4" including shifting of accessories switch, sockets, regulator etc complete all as specified and directed by Engr-in-Charge.
S&F PVC Plastic switch board of size 4"x4" including shifting of accessories switch, sockets, regulator etc complete all as specified and directed by Engr-in-Charge.
S&F in replacement of modular switch single pole one way 6/10 Amps,1 module, complete all as specified and directed by Engr-in-Charge.
S&F in replacement of moduler socket 6/10 Amps -2/3 pin combined 2 module, complete all as specified and directed by Engr-in-Charge.
S&F in replacemnt of modular switch single pole one way 16/20 Amps,1 module, complete all as specified and directed by Engr-in-Charge.
S&Fin replacement of modular socket 6/16 Amps 2/3 Pin combined 2 module, complete all as specified and directed by Engr-in-Charge.
S&F in replacement of modular switch Bell Push 6/10 Amps single pole one way, complete all as specified and directed by Engr-in-Charge. Make-Anchor/havells/bajaj.
S&F in replacement of modular fan regulator Step type 120W 2module, complete all as specified and directed by Engr-in-Charge.
S&F in replacement of sheet metal enclosures with socket plug top with 20 Amps MCB SP enclouser with a two pin and earth plug and socket complete with one single pole MCB of 240 volts.
Supply, fixing, testing and commissioning 20W LED security light fitting with system output of 3000 lumens & with dedicated street light optics, System efficacy of greater than 100 lm/W luminarie should have pressure die cast aluminium LM6 housing. Luminaire should have dedicated street light optics for better uniformity & spacing. Luminarie should have air vents in housing for proper thermal management. Min IP preventation should be IP65. System power consumption (including driver losser) should not exceed 20W complete all as specified and directed by Engr-in-Charge.
S&F security light bracket made out of GI pipe 25mm light grade ISI marked 1.5 Mtr long bend to shape as required for LED fittings at site including M S Clamp 2 Nos made out of flat iron 50 X 5mm with necessary nuts bolts and two coats of alluminium paint over a coat of red oxide primer complete all as specified and directed by Engr-in-Charge.
M&L for Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick buried directly in grond (earth pit not less than 2.25 mtrs below normal ground level) with the top edge of the plate not less than 1.5m below the normal ground level connected to GI wire 4.00mm dia protected by 15mm bore GI pipe (light grade) and watering pipe 20mm bore GI pipe(light grade) and chamber PCC (1:4:8) type D2( using 40mm grade stone aggregate), coping shall be PCC (1:3:6) type C1 using 20mm graded stone aggregate and RCC (1:2:4) type B1 using 20mm graded stone aggregate, pit cover 50mm thick reinforced with 8 mm MS bar at 80mm c/c both way in lieu of CI pit cover with lifting hook including excavation and earth work and removal of surplus soil complete all as shown in electrical plate No-3 of SSR part-I and as specified including earth plate packed around with charcoal dust common salt complete including GI sheet funnel, wire mesh, earth lead wire 4mm dia and earth lead connected to earthing test point/ main board. The GI earth wire 8 SWG under the earth and on pole/db upto a height of 1.5m shall also be protected by 15mm dia GI pipe (light grade ) and the GI pipe to be fixed with poles/wall by means of 02 Nos. FI clamp 25x3mm with nuts bolts and washer etc. complete all as specified and directed by Engineer-in-Charge. Note :- GI earthing wire of same size upto 7.5m shall deemed to be included into quoted rate
Quick Building Service
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .