Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.1 LAccepted-AOC 315 INDUSTRIAL AREA II PANCHKULA 134113 | PANCHKULA | HARYANA | 134113 | L1 | Accepted-AOC accepted being L1 | |
| 2 | L2₹30.6 L+₹2.9 L (10.4%)Rejected-AOC | L2 | Rejected-AOC rejected being L2 |
Tender Value
₹34.6 L
EMD Value
₹53,500
Closing Date
9 Sept 2016, 10:00 amClosed
Executive Engineer, Electrical Division, HP.PWD Ma
Executive Engineer, Electrical Division, HP.PWD Mandi
Construction of Regional Research Instititute Ayurveda at Jaral Sayogi at Pandoh Distt Mandi HP SH SITC of Fire alarm therein
2016_PWD_12843_1
PW/MED /TA/NIT/e-notice/15-16-3287-91 dt. 23.07.16
Open Tender
Electrical Works
Item Rate
730 days
Pandoh Distt Mandi HP
Please refer to NIT and Bid Document
11 documents required · 11 mandatory
₹1,500
Executive Engineer, Electrical Division, HP.PWD Ma
₹53,500
5 Oct 2023
31 Aug 2016
9 Sept 2016
31 Aug 2016
9 Sept 2016
31 Aug 2016
Amount
Supply, Installation, Testing and Commissioning of 4 loop addressable fire alarm control panel, expandable upto 32 loops.each loop must be capable of 256 detectors / Devices, Controller shall be 5.7 inch color touch screen display with stylus(320*240 pixels), inbuilt networking port(both RS485&Ethernet),Serial port for printer,two supervisory inputs,two position key switch and USB port for programming. The Panel shall handle 4096 detection points, 10,000 history events,menu driven user interface with smart search. The events shall be displayed in different colors- red for alarm events & yellow for trouble etc. for easy identification. The Panel shall be VDS/EN 54 approved. Makes: Bosch/ Honeywell(Gamewell)/ Siemens(FireFinder)
Supply, Installation, Testing and Commissioning Active Repeater Panel. Controller shall be 5.7 inch color touch screen display with stylus(320*240 pixels), inbuilt networking port(both RS485&Ethernet),Serial port for printer,two supervisory inputs,two position key switch and USB port for programming. The Repeater Panel shall allow users to acknowledge, reset,silence, program, view hisory events...etc (All functions similar to main panel)The user interface of the repeater panel shall be same as the Main Controller with menu driven user interface with smart search. The events shall be displayed in different colors- red for alarm events & yellow for trouble etc. for easy identification. The Panel shall be VDS/EN 54 approved. Makes: Bosch/ Honeywell(Gamewell)/ Siemens(FireFinder)
Supply, Installation, Testing and Commissioning of intelligent addressable photoelectric smoke detector with two integrated light-scattering smoke sensors using 2 LEDs - blue & infrared. (Detector should comply to Test Fire 1). Detetctor should have 2 inbuilt isolators as per NFPA 72 style 7 wiring requirements and have an option of both soft & hard addressing. Detector should monitor Electromagnetic interference and report to the panel - current and average values. EMC safety for detector shall be 50 V/m. Shall be EN54/ VDs/ certification.(Detectors without Inbuilt Isolators may be considered with an additional Isolator Module per detector) Makes: Bosch/ Honeywell(Gamewell)/ Siemens(FireFinder)
Supply, Installation, Testing and Commissioning of intelligent addressable Multicriteria detector with two integrated light-scattering smoke sensors using 2 LEDs - blue & infrared along with a heat sensor including mounting base. (Detector should comply to Test Fire 1). Detetctor should have 2 inbuilt isolators as per NFPA 72 style 7 wiring requirements and have an option of both soft & hard addressing. Detector should monitor Electromagnetic interference and report to the panel - current and average values. EMC safety for detector shall be 50 V/m. Shall be EN54/ VDs/ certification.(Detectors without Inbuilt Isolators may be considered with an additional Isolator Module per detector) Makes: Bosch/ Honeywell(Gamewell)/ Siemens(FireFinder)
Supply, Installation, Testing and Commissioning of mounting base with Led…etc for maintaining operational of sensors. Approval Make Siemens ( fire Finder ) / Bosch/ Honeywell(Gamewell)
Supply, Installation, Testing & Commissioning of flush mount addressable optical smoke detection system for areas like OT rooms, Conference rooms, areas with high aesthetic requirements , clean room application and for areas with heightened dust exposure. The smoke detection system shall work on Light scattering type principle using Dual detection sensors. The various light-emitting and photo diodes of the sensor are individually controlled by the detector electronics. Consequently, signal combinations are produced that are independent of each other and ideally suitable for the detection of smoke, which makes it possible to differentiate between smoke and interference agents (insects, objects). If required, the contractor shall consider the necessary accessory like reccessed cappilary tubes & nozzles for flush type installation for very early smoke detection for minimum 100 sqmt coverage area. The EMC security fulfills the guidelines according to VdS 2110 (VdS Schadenverhutung GmbH) as well as UL 268. Makes: Bosch/ Honeywell(Gamewell)/ Siemens(FireFinder)
Supply, Installation, Testing and Commissioning of addessable manual break glass unit ( Double action) with inbuilt isolators as per NFPA 72 style 7 wiring requirements, with flexible network structures & necessary fixing arrangements with key complete as required. Shall be EN 54 / Vds/UL Certification. Makes: Bosch/ Honeywell(Gamewell)/ Siemens(FireFinder)
Key for Manual Callpoint Makes: Bosch/ Honeywell(Gamewell)/ Siemens(FireFinder)
Supply, Installation, Testing and Commissioning of Addressable Control Relay Module with inbuilt isolators as per NFPA 72 style 7 wiring requirements & with flexible network structures with a maximun switching current of 1A @ 30V DC. Shall be EN54/ Vds Certification/UL Makes: Bosch/ Honeywell(Gamewell)/ Siemens(FireFinder)
Supply, Installation, Testing and Commissioning of Addressable Module with one input & one output contacts, with inbuilt isolators & with 2 monitoring features, monitoring of a line with EOL resistor ,Potential free contact monitoring. Shall be EN54 / Vds/UL Certification. Makes: Bosch/ Honeywell(Gamewell)/ Siemens(FireFinder)
Supply, Installation, Testing and Commissioning of 1.5 sq mm 2 core coper cable Makes : Polycab/ Havells/Finolex
Supply, Installation, Testing and Commissioning of PVC conduit Make Polyplast/Dplast
Supply, Installation, Testing and Commissioning of Cabinet Speaker Rated power (PHC) 12 W(12-6-3),Sound pressure level at rate power /1 w (at1kHz,1m) - 96dB/90dB, Effective frequency range (-10 dB)- 200- 15000 Hz,Opening angle (at 1 kHz/4 kHz, -6 dB) In degrees - 210/60,Rated voltage - 100 V , Rated impedance -833 Make Bosch/ JBL/Tannoy complete in all respect.
Supply, Installation, Testing and Commissioning of Voice Alarm Controller Heart of the Voice Alarm System Compliant with standards for emergency sound systems (IEC60849) 6-zone system controller Built-in 240 W booster amplifier 12 Business and emergency control inputs and outputs. Frequency response - 60 Hz – 18 kHz (+1/-3 dB, @ -10 dB ref. rated output),Distortion,- < 1% @ rated output, 1 kHz,Bass control -8/+8 dB @ 100 Hz,Treble control -8 /+8 dB @ 10 kHz Make Bosch/ JBL/ Tannoy complete in all respect.
All the makes are to be as per international ISI Specification and to be approved by the Engineer-in-charge
PARCS Group of Associates
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .