| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹88.3 LAccepted-AOC SANSARPUR TERRACE HIMACHAL PRADESH | 1 | Accepted-AOC L-1 | |
| 2 | 2₹97.0 L+₹3.1 L (3.30%)Rejected-AOC | 2 | Rejected-AOC L-2 | |
| 3 | 3₹97.3 L+₹3.4 L (3.61%)Rejected-AOC NIL | 3 | Rejected-AOC L-3 |
Tender Value
₹88.6 L
EMD Value
₹88,592
Closing Date
26 Aug 2021, 12:00 pmClosed
Superintending Engineer
ES Circle Hamirpur
Estimate for laying of 33 kV 3-Core 300 mm2 XLPE Copper Power Cable from 66 kV D/C Tower No. 72 to North Portal of Atal Tunnel, Rohtang.
2021_HPSEB_51445_1
ESCH-02/2021-22
Open Tender
Electrical Works
Item Rate
45 days
Atal Tunnel Rohtang
Please refer Tender documents.
3 documents required · 3 mandatory
₹2,000
₹88,592
22 Sept 2021
19 Aug 2021
26 Aug 2021
19 Aug 2021
26 Aug 2021
20 Aug 2021
Amount
Electrical Part
Providing of HDPE Pipe and Laying of 33 kV 3-Core 300 mm2 XLPE Copper Power Cable in HDPE pipe complete in all respect suitable at enviornment temperature (-25°C).(Cable will be provided by HPSEBL)
Erection & Commissioning of 33 kV GIS Panel at Atal Tunnel North Portal along with all necessary tests complete in all respect.
Providing & Fixing End Termination Kit for 3CX300 Sq. mm 33 kV, Copper XLPE Cable.
Providing & Fixing Straight through joint for 3CX300 Sq. mm 33 kV, Copper XLPE Cable.
Prov. & Fixing Poles (11 m, 37.1 Kg/m) (-25 °C).
Prov. & Fixing Muffs with concreting filling.
Prov. & Fixing X-Bracing Set- MS iron angle-50x50x6mm length:-8140 mm X 4 no.
Prov. & Fixing X-arm (MS Channel iron(100X50X6 mm), Length:2140mmX6no.( for two circuits; left & right)/ run through structure.
Prov. & Fixing Disc insulator with complete fitting 90kN.
Prov. & Fixing 33 kV Pin Insulator TC, 10 kN.
Prov. & Fixing Stay set complete in all respect (4 no. / DP structure).
Prov. & Fixing Stay Wire (7/4.00 mm) (6.0 kg Per Stay Set).
Prov. & Fixing HT Pipe Earthing set complete.
Prov. & Fixing Earth wire (GI, 6 SWG) (includes 2 wire lengths and additional 1% (sag & wastage) @ 150 kg/km.
Prov. & Fixing Half clamps: (On Dead En structure: 2 no., Run Thro' structure: 8 no.).
Prov. & Fixing Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)].
Prov. & Fixing Barbed wire.
Prov. & Fixing Danger Plate (203X200X1.6mm).
Prov. & Painting Aluminium Paint.
Civil Part
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix).
Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.Ordinary rock
Providing and laying in position cement concrete of specified grade excluding the cost of centering andshuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand) : 6 graded stone aggregate 20 mm nominal size).
Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns,etc. for mass concrete.
Centering and shuttering including strutting, propping etc. and removal of form for : Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand): 3 graded stone aggregate 20 mm nominal size)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more.
Structural steel work in single section, fixed with or without connecting plate,including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
RCC Diamond Core Cutting Dia 400 mm Depth 150mm upto 200mm.
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
WORLD CONSTRUCTION CO PRIVATE LIMITED
mohd anwar
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .