| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.9 LAccepted-AOC 43 MANAK BHAVAN FIRST FLOOR GUMANPURA KOTA 324 007 RAJASTHAN | KOTA | KOTA | RAJASTHAN | 324007 | L1 | Accepted-AOC LOWEST AND REASONABLE | |
| 2 | L2₹12.3 L+₹1.3 L (12.1%)Rejected-Finance H1 7 8 IT PARK ROAD NO 4 IPIA KOTA RAJ 324005 | KOTA | RAJASTHAN | 324005 | L2 | Rejected-Finance L2 | |
| 3 | Rejected-Technical 6 SAI KRUPA SONAWANE PARK BEHIND TILAK NAGAR BUS STOP OZAR MIG NASHIK 422206 | NASHIK | NASHIK | MAHARASHTRA | 422206 | - | Rejected-Technical Not having reqd catogary | |
| 4 | Rejected-Technical | - | Rejected-Technical Not having reqd catogary |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
3 Jan 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE JAIPUR
Military Engineer Services, HQ Commander Works Engineer, Kalyan Marg, Banipark, Jaipur-06
REPAIR/ MAINTENANCE OF HIGH VOLTAGE 33KV ELECTRIC SUB STN AT MIL STN KOTA
2023_MES_631679_1
CWE/KOTA/82276/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
KOTA
As per NIT
8 documents required · 8 mandatory
₹500
GE KOTA
₹20,000
Yes
27 Feb 2024
8 Dec 2023
5 Jan 2024
8 Dec 2023
3 Jan 2024
22 Dec 2023
8 Dec 2023 - 21 Dec 2023
Amount
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation etc or for shafts, wells, cess pits, manholes, pier holes, laying cables erection of poles / struts/stays etc not exceeding 10 Sqm on plan, not exceeding 1.5 metre in depth and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm in any type of soil complete all as specified and directed.
Removing of excavated material (soil) to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.50metre above the starting point complete all as specified and directed
M&L for sand cushioning to PVC underground cable with tibba sand and punning to provide a required cover complete all as specified and directed. Note:- Punned thickness shall be considered for payment purpose
Supplying and laying un-reinforced precast cable covers class HV, type I, flat, size 300mm x 180mm x 40mm complete all as specified and directed.
M&L for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint complete all as specified and directed
Dismantling old existing MS cross arms of any type/shape complete all as specified and directed.
M&L of three disc type insulator, Porcelain, vitreous brown, white or green single disc assembly, ball & socket type, for tension clamps for conductors, working pressure 33000 volts complete all as specified and directed
M&L earthing complete as per electrical plate No 3 of MES SSR Part-I with galvanised steel earth plate electrode 600 mmx600mmx6.3mm, buried directly vertically in ground in a pit depth not less than 2.25 metres below ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level connected to and including galvanised iron or steel earth strip 32mm x 6.3mm by means of bolts, nuts check nuts and washers of galvanised iron or steel. Earthing strip shall be protected by galvanised iron or steel pipe 40 mm bore light grade and connected to continuous earth wire on pole / test point. Watering pipe shall be 20 mm bore GI medium grade. The earthing shall be of inclusive of excavation & earth work in any type of soil, charcoal, salt, funnel PCC pit and RCC cover complete all as specified & tested complete. NOTE:- (i)The concrete pit shall be made in PCC 1:3:6 type C-1, using 12.5mm graded crushed stone aggregate 40mm thick precast cover slab of RCC (1:2:4), type B-1, using 20mm graded crushed stone aggregate with suitable MS handle in lieu of CI cover shown in electrical plate No 3 of MES SSR Part-I shall be provided. Reinforcement in RCC cover shall be of 8mm dia TMT bars laid @150mm c/c both ways (ii) Quoted shall include the cost of 7.5 metre GI pipe for protection of earth wire. (iii) Quoted shall include cost of 7.5 metre earth lead wire. (iv) Earth electrode shall be surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides.
M&L for Chemical earthing with copper earth plate 90x60cmx5mm buried directly into ground vertically (earth pit not less than 5.0 mtr deep below normal ground level), with top edge of the plate not less than 4.0 mtr below normal ground lebel, connecting to galvanized earth trip 32x6 mm as earthing strip by means of lugs, bolts, nuts, check nuts and washers protected with and including 80 mm dia light grade GI pipe in floor and fixed with wall with proper size of MS clamps, including necessary excavation and earth work, magnesium sulphare (80 KG), charcoal (4 qtl), and common salt (4 Qtl) filling watering arrangement with 20 mm GI pipe medium grade including PCC pit with precast RCC (1:2:4) cover, GI funnel with test point , complete including testing and connection of earth strip with electrical machine as directed by Engineer-in-Charge. Note- 1. On testing, if desired result is not obtained earthing will rejuveneted at no extra cost till the desired earth resistence is obtained. 2. Items include the cost of GI pipe for protection of earth strip and for watering. 3. The unit rate shall also include for excavation, earth work and PCC (1:3:6) type C1 pit, RCC pit cover etc.
Supply, laying and commissioning 400 sqmm, 3 core, XLPE insulated screened, PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) with aluminium conductor 11000 volts grade earthed IS-7098 marked for HT 11 KV (E) System laid in trenches/ ducts/ encased in GI pipe/ fixed to poles including jointing & testing including taking out old cable complete all as specified and directed
M&L for cable end termination, jointing kit for HT 11 KV (Earthed) grade cable for outdoor termination heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor complete all as specified and directed of following sizes :-
(a) 120 to 185 Sqmm x 3 core
(b) 400 Sqmm
M&L for cable end termination, jointing kit for HT 33 KV (Earthed) grade cable for outdoor termination heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor complete all as specified and directed of size 300 Sqmm x 3 core
S&F of Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required by using galvanised iron 32x6 mm strip as earth lug lead including fasteners complete all as specified and directed
S&F for HT cables route indicator cast iron of suitable size along HT cable trench including painting and grouted in ground in PCC etc complete all as specified and directed.
M&L for Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20cm size and danger plate indicated in hindi and english and local vernacular complete all as specified and directed.
M&L for Anti-climbing device; spikes type fabricated out of M.S. bars (round, square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole etc complete all as specified and directed.
Supply and filling as in replacement of silica gel inside the breather assembly and fixing properly with transformer etc complete all as specified and directed.
S&F lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 KA Amp suitable for 33000 volts complete all as specified an directed
M& L for Servicing & calibration of HT 33 KV VCBs including disconnecting cables of any size raking out of breaker, blowing out dust, cleaning, lubrication/greasing of the mechanical parts, repair/replacement of minor defects in mechanical linkage like replacement of gears etc including test of IR values, healthy check, injection testing, calibration, cleaning of CT, after servicing reconnection in all respect, all as per existing arrangement and restore the supply etc complete all as specified and directed.
Replacement of defective / cracked porcelain bushing (set of three) of suitable size for 33/11 kv transformer upto 3.15 MVA including washers of good quality etc, complete all as specified and directed.
Replacement of defective wornout HT bush rod (set of three) made out of copper with brass nuts and washers of required length including connecting up with HT coil of pewer transformer (33/11 KV) upto 3.15 MVA etc, complete all as specified and directed.
Dehydration and filtration of existing transformer oil using trasnformer oil filtration plant to eliminate foreign particles an dto improve di-electric strength upto 50KV at 2mm electrode gap and to bring the acidity within the permissible limit etc, complete all as specified and directed.
Supply & filling transformer oil for topping up/ refilling the oil having dielectric stength 40-60 KV suring filling after initial filtration etc, complete all as specified and directed.
M&L for painting of power transformer upto 3.15 MVA capacity with good quality synthetic enameled paint suing spray gun with compressed air on complete external portion of transformer including praparation of surface by scrubbing, cleaning, stains greasy sopts, dustetc. The paiting of transformer shall be carried out in situ i.e. on four pole structure or in sub station at different places etc, complete all as specified and directed.
M&L for replacement Numerical control over current earth fault IDMT relay CGI-14 No crompton or equivalent, suitable for the existing VSBs etc, complete all as specified and directed.
M&L for replacement of master trip relay suitable for 24 volt DC supply crompton CGXH1 or equivalent, suitable for the existing VSBs etc, complete all as specified and directed.
M&L for replacement of auxiliary relay suitable for 24 volt DC supply crompton CGXH1 or equivalent, suitable for the existing VSBs etc, complete all as specified and directed.
M&L for replacement of bettery backed power pack unit suitable for input 230 AC and able to supply 24 V DC supply complete all as specified and directed.
M&L for painting of MS structure of 33 KV main receiving station including praparing surface by removing rust using sand paper, applying two coats of aluminium paint over a coat of red oxide primer upto full sruface area including MS clamps, cross arms, bracing etc, complete all as specified and directed.
Supply, laying and testing cable XLPE (heavy duty)armoured, electric power cables (heavy duty) with stranded copper conductor, 1100 volts grade ISI marked, laid in trenches/ under road/ floor or on wall of size 2.5 Sq mm 4 core all as specified.
M&L for servicing & greasing of 33kv isolators for smooth operation etc, complete all as specified and directed.
M&L for perfoming all the routine / safety tests of power transformer inlcuding insulation test, Ratio test, magnetic balance test, test on all protection relays, test on operation and stability of earth fault relays, test on over current relays, trippling tests, buchholz relay tripping & alrm test, test of OTI, WTI including calibration / setting of relays and submission of test report to Engineer in Charge for verification etc, complete all as specified and directed. Note : 1. Test shall be carried out by the OEM or authorised rep of OEM. 2. Certificate of test of OEM will be provided by contractor during RAR/ Final Bill to Engineer-in-Charge for verification and approval of GE.
M&L for current transformer suitable for 33KV (CT) having primary current 150-75 Amp, Phase-1, insulation class-A compliance to IS 2705/1992 standard etc, complete all as specified and directed.
M&L for potential transformer suitable for 33KV (PT) having primary Voltage of 33000 V and secondary 110 V, Phase-1, insulation class-A compliance to IS 2705/1992 standard etc, complete all as specified and directed.
Schedule of Credit
Aditya Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .