Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹29.3 LAccepted-AOC 34 1 TILAK NAGAR KOLKATA 700040 | KOLKATA | KOLKATA | WEST BENGAL | 700040 | 1 | Accepted-AOC LOWEST BID | |
| 2 | 2₹32.8 L+₹3.5 L (11.8%)Rejected-AOC B 13 109 NIMTALA BUS STAND KALYANI NADIA | KALYANI | NADIA | WEST BENGAL | 2 | Rejected-AOC SECOND LOWEST BID | |
| 3 | 3₹35.0 L+₹5.6 L (19.2%)Rejected-AOC 174 G 1 NETAJI COLONY BARANAGAR KOL 700090 | BARANAGAR | KOLKATA | WEST BENGAL | 700090 | 3 | Rejected-AOC THIRD LOWEST BID | |
| 4 | 4₹35.3 L+₹5.9 L (20.3%)Rejected-AOC 14 SURI LANE KOLKATA 14 | KOLKATA | KOLKATA | WEST BENGAL | 700014 | 4 | Rejected-AOC FOURTH LOWEST BID | |
| 5 | 5₹36.4 L+₹7.1 L (24.1%)Rejected-AOC 00 BALITIKURI BALITIKURI NASKARPARA HOWRAH WEST BENGAL 711113 | HOWRAH | WEST BENGAL | 711113 | 5 | Rejected-AOC FIFTH LOWEST BID |
Tender Value
Refer Docs
EMD Value
₹68,000
Closing Date
14 Dec 2021, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE PWD CEC
Central Electrical Circle, P.W.Dte 184, C.R.Das Road, Berhampore, Murshidabad,PIN-742101TelNO.03482-261581 / 6292121856,
Repairing and renovation of EI work at Administrative building GF and 1St Floor front corridor stair and related portion at the Kalyani University Kalyani Nadia EI work
2021_WBPWD_350307_1
WBPWD/CEC/eNIQ/13/Q/2021-22
Open Tender
ELECTRICAL WORKS M/R
Item Rate
45 days
Kalyani University
Please refer Tender documents.
4 documents required · 4 mandatory
₹68,000
VIRTUAL WEBPLATFORM
7 Jan 2022
12 Nov 2021
16 Dec 2021
12 Nov 2021
14 Dec 2021
19 Nov 2021
18 Nov 2021
120 days
Amount
Sub-Head 1--Distribution Wiring Distribution wiring in 1.1KV grade 2x22/0.3(1.5 sq.mm) single core stranded FR PVC insulated & unsheathed copper wire (Gloster/Polycab make) approved by the EIC partly in 20mm size PVC rigid conduit FR Precision make Medium and also use Precision make accessories accessories for Ceiling portion only and in 19mm bore 3 mm thick Polythene pipe for Horozontal & Vertical run embedded in wall including above false ceiling with 1 x 22 / 0.3 (1.5sq.mm) single core stranded FR PVC insulated & unsheathed copper wire for ECC ,to light/fan / call bell poiunts with Piano key type switch fixed on MS CRC 16 SWG Sheet Switch board embedded on wall complete with 2 nos.``Ph & N'' copper bar including bakelite / perpex top cover 3 mm thick (wall matching Colour) and including 175 x 100 x 65mm inspection box embedded on wall, making earthing attachment painting the MS box and mending good damages to original finish as per GS [E15/5] NB - Only PVC Rigid Conduit on Ceiling Portion & the shaddles should be fixing / maintaing 325mm gap between the saddles ,i.e-325mm interval of saddling and also remaining portion Concealed)
Average run 8 mtr.
Distribution wiring in 1.1KV grade 2x22/0.3(1.5 sq.mm) single core stranded FR PVC insulated & unsheathed copper wire (Gloster/Polycab make) approved by the EIC in 20mm size PVC rigid conduit FR Precision make Medium with1.1KV grade 1x22/0.3 (1.5sq.mm) single core stranded FR PVC insulated & unsheathed copper wire as ECC to 6A 5Pin flush type plug socket & Piano key type switch fixed on MS CRC 16 SWG sheet steel switch board on wall including bakelite/perspex top cover (wall matching colour) 3mm thick and including paintaing the MS box and mending good damages to original finish as per GS
On Board
SUB-HEAD 2-- PLUGS & SOCKETS , AC STARTER S&F 240 V 1no. 6A plug socket & 1 no 20 A Plug Socket with separate 1 no 6A & 1 no 20 A Piano key type switch & indicator flush type (Anchor make) on Sheet metal switch board embedded in wall incl S & F 240x 200x 65 mm on MS CRC (16 SWG) switch board with bakelite top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite cover and making necy. connections as reqd. as to GS ( NS) (Power Board Type - II)
S&F 240 V 3 nos. 6A plug socket with separate 3 nos 6A piano key type switch & indicator flush type (Anchor make) on Sheet metal switch board embedded in wall incl S & F 200 x 150 x 65 mm on MS CRC (16 SWG) switch board with bakelite top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite cover and making necy. connections as reqd. as to GS ( NS) ( For Computer Board)
S&F 240 V 1 no. 20 A Plug Socket with separate 1 no. 20A Piano key type switch flush type & indicator (Anchor make) on Sheet metal switch board embedded in wall incl S & F 200 x150 x 65 mm on MS CRC (16 SWG) switch board with bakelite top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite cover and making necy. connections as reqd. as to GS ( 22 / E 6 ) ( For Normal Refrigerator / Water Cooller / Induction)
S&F 240 V 1 no 6A plug socket with separate 1 no 6A piano type switch & indicator fixed on Sheet metal switch board embedded in wall incl S & F 175 x100x 65 mm on MS CRC (16 SWG) switch board with bakelite top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite cover and making necy. connections as reqd. as to GS ( E6/21) ( For Pedestal fan / Normal Aquaguard )
Supplying & fixing 240V 20A flush (Piano) type Socket 5/6 pin Anchor make on 16 SWG CRC sheet metal switch board in wall on surface including S & F 100x100x65 mm CRC sheet metal 16 SWG switch board and bakelite / perspex top cover of 3mm thick by brass screws after making housing for socket by cutting bakelite top cover and making necessary connections as reqired. (For AC machine)
Supplying & fixing 240V 6A flush (Piano) type Socket 5/6 pin Anchor make on 16 SWG CRC sheet metal switch board embedded in wall including S & F 100x100x65 mm CRC sheet metal 16 SWG switch board and bakelite / perspex top cover of 3mm thick by brass screws after making housing for socket by cutting bakelite top cover and making necessary connections as reqired. (E - 6 /17.a) ( for Projector connection / Wall fan Socket)
SUB-HEAD 3--BDB,PDB,VTPN ETC Supplying and fixing MCB 4 Way SS Enclosure type Distribution board with IP-20/30 protection powder coated provision Ref. no. - 8GB32100RC04 ( Make - Siemens/ Legrand/Schneider ) fixed in wall with iron frame (Painted) after cutting wall & mending good damages to finish including necessary connection with earthing attachment . ( For Existing UPS I/C & O/G control)
Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall as per GS ( Make - Siemens/ Legrand/Schneider / L&T )
4 Way (Up to 160A ) For lighting & AC
8 Way (Up to 160A ) For lighting
8 Way (Up to 250A ) For Replace of Existing lt Panel
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed / Surface with Flat (25x6mm)Iron Frame (Painted) in wall ...... as per GS .( Make - Siemens/ Legrand/Schneider / L&T )
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed /Surface with flat (25x6mm) iron frame (Painted) in wall ...... as per GS. ( Make - Siemens/ Legrand/Schneider / L&T )
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection as per GS ( Make - Siemens/ Legrand/Schneider / L&T )
40 A DP ( for SPN MCB DB - 5 nos. & MCB Enclosure - 5 nos)
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS ( Make - Siemens/ Legrand/Schneider / L&T)
6-32 A SP MCB as per instruction of EIC (For HTPN MCB DB - 108 nos., SPN MCB DB - 50 nos.& MCB Enclosure - 10 nos.)
63A TP For VTPN DBs
Supplying and fixing 415V Four Pole MCCB OF Breaking capacity 25 / 35KA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection as per GS. ( Make - Siemens/ Legrand/Schneider / L&T )
160A 35KA Breaking capacity
250A 35 KA Breaking capacity
SUB-HEAD 4-- Polythene pipe and wires Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire of the following sizes in the prelaid polythene / Precission Medium Make rigid pipe as per GS. (Make : Polycab/Gloster / KEI / RR KABLE )
3 x 22 / 0.3 (1.5 sqmm) (for use of existing switch board power supply & compoud Lighting )
2 x 36 / 0.3 (2.5 sqmm)+1 x 22 / 0.3 (1.5 sqmm) as ECC (For Power plug , Computer Plug )
2 x 56 / 0.3 (4 sqmm) + 1 x 36 / 0.3 (2.5 sqmm) as ECC (For Split type A.C Machine existing starter)
2 x 84 / 0.3 (6sq.mm) + 1 x 56 / 0.3 (4 sqmm) [ (For SPN DB)
4 x 196 / 0.4 (10 sq.mm) + 2 x 80 / 0.4 (6sqmm) For VTPN DB to TPN DBs incoming
Finishing of the PVC insulated Cu. wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
Cutting Channel of size (40 mm x 40 mm) / (43 mm x 43 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 13/19/25 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles as per GS.
19mm dia 3 mm thick
25 mm dia 3 mm thick
Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes flushed in wall by housing the same after cutting brick wall incl. making earthing attachment, painting and mending good damages to building works
100 mm x 100 mm x 65 mm
150 mm x 100 mm x 65 mm
175 mm x 100 mm x 65 mm
200 mm x 150 mm x 65 mm
240 mm X 200 mm x 65 mm
Supply & Fixing bakelite / perspex top cover on existing switch board by Brass screws after making housing for switch by cutting bakelite / perspex cover and making necessary connections as required
100 mm x 100 mm x 65 mm
150 mm x 100 mm x 65 mm
175 mm x 100 mm x 65 mm
200 mm x 150 mm x 65 mm
240 mm X 200 mm x 65 mm
Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make Medium ] on wall, ceiling with precision make saddles and other accessories as required and mending good damages to building works as per GS. N.B. - Should be fixing the Saddle maintaining 325mm gap between the saddles)
20mm size
25mm size
SUB-HEAD 5-- SUPPLY & LAYING OF CABLES Supply of 4 Core XLPE Insulated & Sheathed Armoured Aluminium power cables for Working Voltage up to 1100 Volts of following sizes [ Make Gloster / KEI / RR KABEL / POLYCAB ]
25 sq.mm [NS](Existing TPNDB connection )
35 Sq.mm (NS) (Existing TPNDB connection )
70 sq,mm (NS) [ Main Panel to VTPN Power / lighting ]
95 sq,mm (NS) [ Main Panel to VTPN Power / AC ]
120 Sq.mm ( NS) [ For Main panel to Sub panel - 1 /2 incoming]
150Sq.mm (NS) [ For Main panel to Sub panel AC Hall incoming]
300 Sq.mm (NS) [ From S/S LT Panel to Admn. Main Panel ]
Laying of cable upto 4 core 25 sqmm on wall / surface incl. S & F saddles with earthing attachment (2x10SWG) as to GS N.B. - Should be fixing the Saddle heavy gauge double screwed type maintaining 325mm gap between the saddles)
Laying of cable upto 3.5 / 4 core 35 sqmm to 50 sq.mm on wall / surface incl. S & F saddles with earthing attachment (2x10SWG) as to GS N.B. - Should be fixing the Saddle heavy gauge double screwed type maintaining 325mm gap between the saddles)
Laying of cable upto 3.5 / 4 core 50 sq.mm and upto 95 sq.mm on wall / surface incl. S & F saddles with earthing attachment (2x10SWG) as to GS N.B. - Should be fixing the Saddle heavy gauge double screwed type maintaining 325mm gap between the saddles)
Laying of cable from 3.5 /4 core 95 sq.mm and upto 150 sq.mm saddling on wall/surface incl S & F MS saddles with earthing attachment in 2x10 SWG GI ( Hot Dip) wire making hole etc as per GS N.B. - Should be fixing the Saddle heavy gauge double screw type maintaining 325mm gap between the saddles)
Laying of cable as below, after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damages to original finish incl. removing the rubbish
From 2.5 sq.mm to 35 sq.mm at an average depth of 75 mm in floor/pavement/wall etc
Above 35 sq.mm to 95 / 120 sq.mm at an average depth of 100 mm in floor/pavement/wall etc.
Above 95 sq.mm and upto 240 sq.mm at an average depth of 100 mm & above / as required / as per instruction of EIC in floor/pavement/wall etc.
Laying of one no. cable above 35 sq.mm and upto 185 sq.mm in under ground trench 460mm wide x 760mm average depth with brick protection on the top of the cable with 8 (Eight) nos. bricks per Mtr. including filling the space between the bricks and cable and also the trench with shifted soil,leveling up and restoring surface duly rammed . asper GS . (For 120 sq.mm & 150 sq.mm cable )
Laying of one no. cable above 185 sq.mm in under ground trench 460mm wide x 760mm average depth with brick protection on the top of the cable with 8 (Eight) nos. bricks per Mtr. including filling the space between the bricks and cable and also the trench with shifted soil,leveling up and restoring surface duly rammed . asper GS .
Supplying and fixing compression type gland complete with brass gland , brass ring & rubber ring for dust & moisture proof entry of XLPE / PVC armoured cables as below Dowels make gland.as per GS
4 Core 25 Sq. mm
4 Core 35 Sq. mm
4Core 70Sq. mm
4Core 95Sq. mm
4 core 120 sq.mm
4 core 150 sq.mm
4 core 300 sq.mm
Finishing of the XLPE / PVC insulated armoured cable ends by crimping method incl. supplying & fixing solder less socket ( DOWELS ) make , tapes , anticorrosive paste & jointing materials as per GS.
4 Core 25 Sq. mm
4 Core 35 Sq. mm
4 Core 70Sq. mm
4 Core 95Sq. mm
4 Core 120 Sq. mm
4 core 150 sq.mm
4 core 300 sq.mm
Supplying & fixing medium gauge GI pipe (ISI medium) protection with necessary fittings and jointing materials as required
40 mm dia
50mm dia
80 mm dia
100 mm dia
SUB-HEAD 6-- FIXING OF LED light fittings Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length
Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length
Fixing only outdoor / street light type fluorescent light fitting complete with all accessories to be fixed/projected from the wall of the building incl. making holes to building, S&F 40 mm dia GI pipe (ISI-Medium) 1.50 mts. average length, with GI socket at one end and thread at the other end & suitable bend to house the fitting & making necy. connections with S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall and painting
SUB-HEAD 7 - SUPPLY OF LIGHT FITTINGS Supply 90 Watt Outdoor Street Light Fittings Cat No LSTP -90 -CDL Cromton Greaves Makes ) ( For outdoor illumination)
Supply 80 Watt Outdoor Light Fittings Cat No LFL-80 -CDL (Cromton Greaves Makes )
Supply of 230V 50 Hz 4 ft LED T-8 box type batten with end cap complete with accessories ( Make - Philips)
(i) Philips Make Cat No -TMC 501 P 2 X T-LED 22 W P 3241
(ii) Philips Make Cat No -TMC 501 P 1 X T-LED 22 W P 3241
(iii) Philips make PC body 22Watt LED T-8 2100lm lamp ( type - MAS LED tube STD 1200 mm 18 W 865 T8 I - 2100lm)
Supply 230 V 50 Hz 9 watt LED bulb Phillips make in the existing porcelain holder.
Supplying & fixing Philips (Signify) make Endura LED WellGglass Type - BY201P LED 78S CW PSU HE PC surface mounted robust & reliable IP66 & IK08 Protected wellglass LED luminarires wuth PDC housing & polycarbonate diffuser i.e suitable for ceiling & wall mounted with fastner 9mm dia 100mm long including S & F fastner etc as required also making connection complete .
SUB-HEAD 8-- FIXING OF FANS light fittings Supplying & fixing socket type fan regulator (Step Type) Anchor make on existing sheet metal switch board with bakelite / perspex top cover by screw after making housing for regulator knob by cutting bakelite / perspex top cover including making necessary connections etc.
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc as per GS
Supplying & Fixing MS fan clamp of two piece type for RC ceiling (Size of Flat 40x9mm) as per approved specification as per GS.
Supplying & fixing 20mm dia GI Pipe ISI make medium for making ceiling fan Down Rod same as (as per original) original dn rod including cutting , drilling , splitting etc complete [ NS ]
Supply of ceiling fans complete with all accessories having the following Model / Cat No. ( Make -Usha)
a. 1200 mm Sweep ( Usha Strikaer ) [ NS ]
SUB-HEAD 9 -- Earthings Earthing with 50 mm dia GI pipe (TATA-Medium)x 3.0 Mts.long and 1 x 4 SWG GI (HOT DIP) wire (4 Mts. long) 13 mm dia x 80 mm GI bolts , double nuts , double washers including S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below. a) BY ISI - Medium GI pipe.
S&F earth busbar of galvanized (Hot Dip) MS flat 25x6mm on wall having clearance of 6 mm from wall incl. providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as reqd. as per GS
Connecting the equipments boaddy to earth busbar including S & F 25 x 6 mm galvanised (Hot Dip) MS flat on wall / floor with GI saddles as required and connecting to the equipments including drilling holes , with bolts , nuts , washers etc as per GS.
SUB-HEAD 10-- Additional Main switches , Loop Box Supplying & fixing 415V TPN SFU with sheet steel enclosure on flat iron / angle iron frame / any type of extension pieces including painting on wall / existing panel with nuts bolts etc. as required including S & F 3 nos. DIN type HRC fuse with suitable size cable ends box as per rating as per GS .( siemens / abb / legrand / L&T)
Supplying & Fixing GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive paint
SUB-HEAD 11 -- Dismantlings Works Dismantling the existing working / non working electrical accessories like all kinds of old wirings , MS conduit pipe , main switches , Main switch netgurd , TPN & SPN fuse DB , MCB DBs , light , fans existing power board , cables , glands , existing working damaged panels , incoming & out going cable connections along with accessories etc as per avaiablity at site during execution job / as per instruction of EIC for making space & installation of new accessories including mending good damages & finish .
Refixing the existing dismantled SDF unit with the existing iron frame including painting after grouting the wall in proper method / as per instruction of EIC complete also the net gurd should be fixing after cutting the net guard frame .
Lifting of GI Pipe laid cable for accommodating in the newly installed panel board of 4 / 4 core 120 sq.mm XLPE cable after opening the inner part / end by releasing the concerete and other end should be released by excavation of earth cautiously for avoiding any damage of cable and after completion of job the cable should be resetting same as previous condition by CC morter & shifted soil etc c required including mending good damages & finish. (NS)
SUB-HEAD 12 -- LT Panel type 1 Supply & delivery of CPRI approved cubical type L.T. Distribution panel board floor or wall mounting type of required size, compartmentalized with maple arrangement having rigid & self supporting structure fabricated from 2 mm thick CRCA sheet steel with MS angle iron frame. The panel board consisting of the following switches. A) Incoming Arrangement. switch disconnector fuse unit conform to IS 13947 in open execution three pole & Neutral, 50HZ, 415V 630A Amp with 3 nos 630 Amp Din type HRC fuse link , [ Make-L&T / ABB / LEGRAND / SIEMENS ] --- 1 Nos . B) Bus Section: 415 V 1000 A. electrolyte graded copper bus bar of suitable size Cu. bar for Ph & N . The bus bar shall be fixed with FRP chair & the entire bars are insulated with PVC heat Shrinkable sleeve of suitable size & different coloured as per norms / direction of E.I.C
C) Outgoing arrangement: i) switch disconnect or fuse conform to IS : 13947 in open execution three pole & Neutral 50HZ, 415 Volt i) 400A - 1 no. ii) 315A - 2 nos. , iii) 250A - 2 nos, iv) 200A - 3 nos. v) 100A - 2 nos. with Din type HRC fuse link as per rating of each SFU ,[ Make-L&T / ABB / LEGRAND / SIEMENS] -- All SFUs should be connected with the required size copper cable or equivallent rating Copper flat
E) Cable Alley: Cable entry arrangement will be provided in the back side of the cubical panel in vertical position , Suitable capacity 4 way AC/DC connector indicating phase & neutral for each outgoing main switches including detachable type gland plate must be placed at the bottom of the panel with as per direction of E.I.C. . F) Painting. The complete panel board shall be painted by 2 coats of powder coated synthetic enamel Paint over two coats of R.O. primer of Approved make & brand & color as per Direction of E.I.C. G) Constructural Details: All incoming & outgoing panel mounted cubical Switch disconnector fuse shall be housed in Respective compartment with hinged & gasketted Door at front. All doors shall have Panel lock Arrangement. The panel shall be properly gasketted to prevent ingress of dust & vermin proof. Busbar shall be rigidly fixed & all Switches shall be fixed by S.S. nuts & bolts washers. H) Continuous GI flat 50 X 6 mm as earth bus bar
SUB-HEAD 13 -- LT Panel type 2 Supply & delivery of CPRI approved cubical type L.T. Distribution panel board floor or wall mounting type of required size, compartmentalized with maple arrangement having rigid & self supporting structure fabricated from 2 mm thick CRCA sheet steel with MS angle iron frame. The panel board consisting of the following switches. A) Incoming Arrangement. switch disconnector fuse unit conform to IS 13947 in open execution three pole & Neutral, 50HZ, 415V 630A Amp with 3 nos 630 Amp Din type HRC fuse link , [ Make-L&T / ABB / LEGRAND / SIEMENS ] --- 1 Nos . B) Bus Section: 415 V 1000 A. electrolyte graded copper bus bar of suitable size Cu. bar for Ph & N . The bus bar shall be fixed with FRP chair & the entire bars are insulated with PVC heat Shrinkable sleeve of suitable size & different coloured as per norms / direction of E.I.C
C) Outgoing arrangement: i) switch disconnect or fuse (panel mounting cubical type) conform to IS : 13947 in open execution three pole & Neutral 50HZ, 415 Volt , i) 200A - 3 nos. ii) 160A - 2 nos. with Din type HRC fuse link as per rating of each SFU [ Make-L&T / ABB / LEGRAND / SIEMENS] - All SFUs should be connected with the required size copper cable or equivallent rating Copper flat
E) Cable Alley: Cable entry arrangement will be provided in the back side of the cubical panel in vertical position , Suitable capacity 4 way AC/DC connector indicating phase & neutral for each outgoing main switches including detachable type gland plate must be placed at the bottom of the panel with as per direction of E.I.C. . F) Painting. The complete panel board shall be painted by 2 coats of powder coated synthetic enamel Paint over two coats of R.O. primer of Approved make & brand & color as per Direction of E.I.C. G) Constructural Details: All incoming & outgoing panel mounted cubical Switch disconnector fuse shall be housed in Respective compartment with hinged & gasketted Door at front. All doors shall have Panel lock Arrangement. The panel shall be properly gasketted to prevent ingress of dust & vermin proof. Busbar shall be rigidly fixed & all Switches shall be fixed by S.S. nuts & bolts washers. H) Continuous GI flat 50 X 6 mm as earth bus bar
SUB-HEAD 14 -- LT Panel type 3 Supply & delivery of CPRI approved cubical type L.T. Distribution panel board floor or wall mounting type of required size, compartmentalized with maple arrangement having rigid & self supporting structure fabricated from 2 mm thick CRCA sheet steel with MS angle iron frame. The panel board consisting of the following switches. A) Incoming Arrangement. switch disconnector fuse unit conform to IS 13947 in open execution three pole & Neutral, 50HZ, 415V 400A Amp with 3 nos 400 Amp Din type HRC fuse link , [ Make-L&T / ABB / LEGRAND / SIEMENS ] --- 1 Nos . B) Bus Section: 415 V 800 A. electrolyte graded copper bus bar of suitable size Cu. bar for Ph & N . The bus bar shall be fixed with FRP chair & the entire bars are insulated with PVC heat Shrinkable sleeve of suitable size & different coloured as per norms / direction of E.I.CB) Bus Section:
C) Outgoing arrangement: i) switch disconnect or fuse (panel mounting cubical type) conform to IS : 13947 in open execution three pole & Neutral 50HZ, 415 Volt , i) 200A - 2nos. ii) 100 - 6 nos. All SFUs should be connected with the required size / equivallent rating Copper flat [ Make-L&T / ABB / LEGRAND / SIEMENS] - All SFUs should be connected with the required size copper cable or equivallent rating Copper flat
E) Cable Alley: Cable entry arrangement will be provided in the back side of the cubical panel in vertical position , Suitable capacity 4 way AC/DC connector indicating phase & neutral for each outgoing main switches including detachable type gland plate must be placed at the bottom of the panel with as per direction of E.I.C. . F) Painting. The complete panel board shall be painted by 2 coats of powder coated synthetic enamel Paint over two coats of R.O. primer of Approved make & brand & color as per Direction of E.I.C. G) Constructural Details: All incoming & outgoing panel mounted cubical Switch disconnector fuse shall be housed in Respective compartment with hinged & gasketted Door at front. All doors shall have Panel lock Arrangement. The panel shall be properly gasketted to prevent ingress of dust & vermin proof. Busbar shall be rigidly fixed & all Switches shall be fixed by S.S. nuts & bolts washers. H) Continuous GI flat 50 X 6 mm as earth bus bar
HALDER ELECTRIC
KANJILAL and SONS
T.D.K. ENTERPRISE
CHAKRABORTY ENTERPRISE
GEM ENGINEERS CO-OP SOCIETY LTD
stage.html
html • 0.05 MB
techsummary_674550.pdf
PDF • 0.39 MB
finance_674550.pdf
PDF • 0.39 MB
BOQ Comparative Chart
xlsx • 0.03 MB
finsummary_674550.pdf
PDF • 0.18 MB
WorkOrderLOA13.pdf
PDF • 0.11 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .