Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.5 LAccepted-AOC KORAMANGALATH HOUSE TOMY LANE SOUTH PANAMBILLY NAGAR KADAVANTHRA P O KOCHI 682 020 | KOCHI | ERNAKULAM | KERALA | 682020 | L1 | Accepted-AOC AOC | |
| 2 | L2₹16.2 L+₹2.7 L (19.8%)Rejected-Finance 9 8 B THENGUMTHARAVIL MLA ROAD PANANGAD PO KOCHI 682506 | KOCHI | ERNAKULAM | KERALA | 682506 | L2 | Rejected-Finance L1 being accepted |
Tender Value
₹13.8 L
EMD Value
₹27,500
Closing Date
28 Jul 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(I)(CG)KOCHI
GE(I)(CG)KOCHI BUILDING NO.22/2614, OPP. SANTHOM CHURCH MUNDAMVELI POST RAMESWARAM KOCHI-682 507
REPAIRS MAINTENANCE OF HANGARS AND ASSOCIATED INFRASTRUCTURE AT CGAE NEDUMBASSERY, KOCHI
2022_MES_533803_1
GE/CG/8811
Open Tender
Civil Works
Item Rate
180 days
KOCHI
AS PER NIT/TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE(I)(CG)KOCHI
₹27,500
Yes
24 Aug 2022
27 Jun 2022
4 Aug 2022
27 Jun 2022
28 Jul 2022
13 Jul 2022
27 Jun 2022 - 4 Jul 2022
60 days
Amount
SCHEDULE 'A' PART- I(B/R WORKS)
Material and Labour for applying two coat of epoxy paint on old steel surfaces after preparation of Gantries/ EOT Cranes of any description, size and in any position / direction in Hangars exceeding 10 cm width or girth including and after application of Epoxy Zinc rich primer on the prepared steel surface by spray guns or any other mechanical method, the primer shall have a minimum specific gravity 1.75, minimum wet film thickness / coat 40 microns minimum adhesive bond strength with steel is 1.50N / Sqmm including completely scrapping down old trated paint surface with flame burner/ blower complete all as specified and directed by the Engineer-in-Charge. Make : Fosroc / Dr. Fixit / Sika / Berger / Asian/Shalimar/Johnson & Nicholson/Berger/Nerolac Paint Ltd
Dismantling structural steel work including doors, gates but excluding framed truss etc all as per specified and as directed.
Supply and fix mild steel tubular Posts, struts etc including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 as in bracing members. stoppers of Hangars doors etc complete including necessary cutting , wedling in any shape and in any postion / direction in hangar doors etc complete all as specfified and as directed by the Engineer-in-Charge.
Supply and fix Rolled mild steel as in heavy bracket stoppers of Hangars doors of any size and in any direction including fastenings complete for stoppers of Hangars doors etc complete including necessary cutting , welding in any shape and in any postion / direction in hangar doors etc steel of grade Fe-410W (Gde E-250) quality B complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix Rolled mild steel in Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) Fe 410 -W (Gde-E-250) quality-B as in bracing members. stoppers of Hangars doors etc complete including necessary cutting , welding in any shape and in any position / direction in hangar doors etc complete all as specfified and as directed by the Engineer-in-Charge.
Material and Labour for applying two coat of epoxy paint on new untreated steel surfaces of bracings and stoppers of Hangars doors exceeding 10 cm width or girth including and after application of Epoxy Zinc rich primer on the prepared steel surface by brush, the primer shall have a minimum specific gravity 1.75, minimum wet film thickness / coat 40 microns minimum adhesive bond strength with steel is 1.50N / Sqmm complete all as specified and directed by the Engineer-in-Charge. Make : Fosroc / Dr. Fixit / Sika / Berger / Asian.
Dismantling for plain or corrugated steel sheeting, any guage, thicknes, complete all as specified.
Supply and fix pre-colour coated high tensile strength galvalume sheet roofing with yield strength (550 Mpa) prepainted with aluminium (55%) and zinc (45%) alloy coating applied through continous hot dip process having total coated thickness (TCT) of 0.50mm with minimum coating mass on both sides @ 150gms/sqm in length and width as per site condition fixed with complete acessories as per manufacturer's instructions through specialist agency and as per profile and shade as approved by GE complete all as specified and directed.
All as per item No.8 above but as in ridge/flashing board of width and girth not less than 610mm.
Supply and fix Fibre reinforced translucent sheet of 2mm thickness corrugated sheet with two corrugations side lap fixed with coah screw and washer in roof etc complete all as specified and as directed.
Supply and fix Closing of botls holes / holes in old corrugated steet sheet/ Firbe translucent reinforced sheets of any description and in and postion by sealing with sealent/ silicon/suitable bituminous washers as in Hangars complete all as specified and as directed by Engineer-in-Charge.
Supply and fix mild steel plate(plain or chequerred), square cut or notched(ordinary or counter sunk) forming holes with riveted, bolted or welded attachment to bottom of pipe conforming to Fe 410-W quality B(Gde-E-250) complete all as specified and directed.
Taking down sliding type Hangars door shutter/ Leaf of area exceeding 60 sqm but not exceeding 70 sqm by using of hydraulic/ mechanical cranes other tools & plant, necessary errection/ dismantling of scaffolding required for lowering down the shutters for repairing work and re-fixing the door shutters in position after necessary repair work as directed for smooth functioning complete, and all as specified and directed by Engineer-in-Charge. Note-1: Repair/ maintenance work of steel sliding doors in Hangars shall be measured and paid separatly under relevant items. Repair / Maintenance of sliding type steel Hangars doors each leaf size (8.82 mtr x 7.20 mtr) or above upto 10.00 mtr height of Hangars of any size of leaf in Hangars comprising the following work all as specified & directed by Engineer-in-Charge:- (a) Taking down / out total 02-04 Nos bottom wheel with bearing, and refixing the same with new ball bearing of 50mm bore (ID)including fixing of shaft with pedestals. (b) Taking down / out all shafts with bush at top and replaced with new shaft and bush with ball bearing of 50 mm bore.(4 Nos with bearing, 2 nos with out bearing (shaft 90 mm dia) in each Leaf) (c) Taking down of chain sprocket, gear box, cleaning of chain sproket box, oiling greasing complete and refixing with new chain and sprockets. (d) Cleaning of guide channel. (e) Contractor shall provide all necessary safety measures for the removal and refixing of Hangar door and program of removal/refixing work shall be got approved from Engineer-in-charge and User unit before removal/refixing of Hangar door. (f) All the labours engaged for Hangar door work shall be covered under personal insurance and all safety measures insisted by the Engineer-in-charge shall be strictly followed during execution of work. Note-2:- The repair work of Hangar door including removal and refixing of door shall be carried out through specialist agency experienced in the field and such firm shall be got approved by the Engineer-in-charge after verification of testimonial of the firm based on past track experience. The work shall be commenced only after the approval of the Engineer-in-charge.
Remove the existing damaged filling compound by raking end using blow lamp and cleaning of surface crack of 5 to 25mm expansion/construction/dummy joints for concrete pavement of dispersal area etc free from dust and applying masking tape on edge of joint to prevent accidental spillage of sealant on top surfaces and to give a neat finish to the sealant and removing the masking tape and provision of polyethylene backup rod 8mm to 10mm dia for construction/dummy joints and 20mm to 25mm dia for expansion joints and sealed with Flex-o-patch elastomeric material/ COLPOR 200 polyurethane based sealing compound confirming to BS 5212-1990 or equivalent of approved colour after application of suitable primer etc complete all as specified and as per manufacturers instructions. The size of the joint shall be 5mm to 20mm width and 23mm to 37mm deep complete all as specified and directed. Note:- (a) The existing sealing compound / cracked surfaces of concrete shall be taken out completely using blow lamp and joint shall be cleaned with wire brush and loose particles dust etc shall be removed by using hand pump before applying primer. (b) Any spillage of material during filling over the slab shall be removed and cleaned by contractor and any damage accrue to the concrete slab shall be made good by the contractor without any extra cost to the department.
Carrying out the SRT (Skid Resistance Test) as per standard tests procedure mentioned in Airport Service Manual to find out the coefficient of friction of runway/ Dispersal and submission of test report in 04 hard copies with 03 soft copies in DVD/CD completed all as specified and as directed by Engineer-in-Charge.
Material and Labour for Forming 12mm thick expansion joints in 150mm thick concrete slab of any description and filled with pre formed bituminous filler and top 30mm primed and sealed with sealing compound Grade 'A' including removing the existing damaged filling compound by raking end using blow lamp and cleaning of surface crack of 5 to 25mm expansion/construction/dummy joints for concrete pavement of deispersal area etc completed all as specified and as directed by Engineer-in-Charge.
Material and Labour for Forming construction joint 30mm deep x 10mm wide filled with sealing compound of grade 'A' including removing the existing damaged filling compound by raking end using blow lamp and cleaning of surface complete all as specified and as directed.
Note for all items (Item Nos. 1 to 17) of this Schedule :- (i) (SITE FOR EXECUTION OF WORK) The Bidders shall note that work has to be executed at dispersal area. Site for execution of work will be made available to contractor on Saturday, Sunday, Holidays and non operational days or as assigned by the Engineer-in Charge after consultation with user unit, due to constant operational commitment at CGAE Station. The contractor shall arrange working programme accordingly. No claim whatsover, for not giving the entire site, on award of work and giving the site gradually will be entertained.The contractor shall consider this aspect while quoting the tender. (ii) The work shall be executed to high rise structure of height up to 20 metre from ground level. Quoted rate shall be deemed to including for all kind of Scaffolding and safety equipment provided to worker deployed by the contractor and no extra amount paid by the department for the same and the work shall be carried out without any damage to the existing structure. Any damage occured due to contractor shall be rectified without any extra cost to the Goverment.
SCHEDULE 'A' PART- II(E/M WORKS)
Supply and Fix in repairs Omni-directional, Elevated, Taxiway Edge Light with Blue 1 W LED and blue lens, including electronic convertor, Breakable coupling, Base plate, secondary lead, set of SS bolt/Washer set with suitable lamp and holder and suitable to operate with 2.8 Amp to 6.6 Amp power source and cable connection from transformer to light fitting complete as per FAA L-823, including testing and commissioning all as per ICAO standards and as directed at site. Make: AMA /Honeywell/Tata Power SED/Three D Integrated Solutions Ltd.
Supply and Lay of Cable Single core, 6 Sqmm, 5 KV grade, PVC insulated, PVC Sheathed, unarmoured stranded copper conductor as per IS-1554 part-II as amended upto date laid in trenches/floor/Wall/drawn through pipes/conduits etc complete including testing and commissioning all as per ICAO standards including taking out unserviceable cables complete all as specified and as directed. Make: Havells/Polycab/Finolex/ICC / Unistar / NICCO / Asian (RPG)/CCI / Gloster.
Supply and Fix in repairs series type Isolating Transformer 15W, 6.6/6.6 amps, 5 KV grade, 50 Hz, moulded with neoprene type rubber with primary and secondary connectors for elevated type light fittings complete including testing and commissioning all as per ICAO standards and as directed at site. Make: Bildal/Vajra Transformers Pvt Ltd/Truetech Products/Insel rectifiers India or equivalent
Supply and fix in repairs push button switches for ON/OFF and emergency stop for hangar door motor control complete all as specified and as directed.
Supply and fix in repairs electric motor for hangar door rated 10 HP, 3 phase suitable for voltage 415 V +/-10%, frequency 50Hz +/-5%, continuous rating(S1 duty) IP-55 enclosure, 3000 rpm complete all as specified and as directed.
Supply and fix in repairs LED highbay light 150 watt energy saving environment friendly and robust LED luminaire with efficacy suitable for ceiling(Surface/suspened) IP65 complete all as specified and as directed. Make: Cat No.RADIOSOHB150WLED75760DBOPC of Havells or equivalent in Crompton Greaves/Philps/Bajaj
Schedule of Credit (Minus) Rs. 53,600.00 NOTE: Bidder shall insert credit amount of Rs. 53,600.00 as rate in Green field under Col-13.
T.I.John and Sons
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .