| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.5 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹10.5 L+₹1.8 L (21.3%)Rejected-Finance 61 ABHAY GARH SCHEME AIR FORCE JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L2 | Rejected-Finance NOT BEING L1 | |
| 3 | L3₹11.2 L+₹2.5 L (29.2%)Rejected-Finance | L3 | Rejected-Finance NOT BEING L1 | |
| 4 | Rejected-Technical NOT SPECIFIED IN THE DOCUMENT | - | Rejected-Technical IN WLR FOR QE JUN 2019 MENTIONED NO |
Tender Value
₹9.5 L
EMD Value
₹19,000
Closing Date
4 Sept 2019, 6:00 pmClosed
AGE I Nagtalao
Military Engineer Services AGE I Nagtalao Pin-900120 CO 56 APO
REPAIR REPLACEMENT OF EXISTING EARTHING BOREWELL AND UNSERVICEABLE LIGHTING PROTECTION BY ESE SYSTEM INCLUDING CONNECTED WORKS AT NAGTALAO UNDER AGE I NAGTALAO
2019_MES_267594_2
8105/19-20/E8
Open Tender
Electrical and Maintenance Works
Item Wise
120 days
AGE I Nagtalao
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
AGE I Nagtalao
₹19,000
Yes
29 Jun 2020
22 Aug 2019
6 Sept 2019
22 Aug 2019
4 Sept 2019
29 Aug 2019
Amount
Taking out old unserviceable rusted earthing material including test point of any type from the site by providing necessary excavation and making good disturbed surfaces to match with original status by filling , levelling etc complete all as specified and directed by Engr-in-Charge.
Taking out old unserviceable rusted strip of any type and size from the site by providing necessary excavation and making good disturbed surfaces to match with original status by filling , levelling etc complete all as specified and directed by Engr-in-Charge.
M & L for bore well earthing by drilling bore with bore machine for poles and other machinery / eqpt using GI pipe heavy duty 50 mm dia as earth electrode driven up to a minimum depth of 60 meters below ground level, duly made holes of 6 mm dia at 20 cm intervals, along with the length of GI pipe and providing the charcoal salt mixture incl GI pipe of150 mm dia light grade as protection upto depth of 12 meters and GI strip of 32x6 mm to connect the Test points or directly to the system and commissioning complete all as specified and directed by Engr-in-Charge. Note:-(i)Material of earthing will be laid in borewell on the presence of Engr-in-Charge or his Rep.(ii)Earth strip of 32X6 mm size up to the length of 7.5 RM including porcelain insulator of suitable size or any other petty items required for fixing will deemed to be inclusive of quoted rates.Note:-Material of earthing will be laid in the trench of borewell on the presence of Engr-in-charge or his Rep.
M/L for earthing with copper plate electrode 60 cm X 60 cm X 3.15 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with the top edge of the plate not less than 1.5 mtr below normal ground level, connected to copper strip 32 X6 mm as earthing lead by means of bolts, nuts, checknuts and washers of copper , Copper strip protected by 20 mm bore light grade GI pipe and other end connected to earthing test point or main switch board as directed including funnel with watering pipe of 15 mm bore light grade GI , wire mesh, charcoal or coke and common salt in alternate layer of 15 cm compacted thickness all around the earth electrode PCC (1:3:6) type C-1 earth pit, RCC cover, handle, including necessary excavation and earth work and necessary testing complete all as specified and as directed and shown on electrical plate No 5 of MES Schedule part I. Note:-Material of earthing will be laid in trench on the presence of Engr-in-charge or his Rep.
Supply & laid copper strip in repair of size 32 mm X 6 mm as a ring conductor network buried in ground 1 mtr below from surface complete all as directed at site by Engr-in -charge
Taking out old Unsv lightning protection system including Air termination rod, Aluminium strip , GI strip and earthing of any type complete all as specified and directed by Engineer-in-charge.
Supply installation testing and commissioning of lightening protection system Early Streamer Emission (ESE) lightening protection Air terminal OPR (Optimized Pulse Rod) complies with NF C-17-102 standards complete all as specified and directed by Engr-in-Charge. Make – ABB Model OPR-60 and equivalent in Alstom/OBLUM
Supply and fix stainless steel pipe of 50 mm mounting mast 2 m , 30 mm dia fabricated with support structure and guying kit provided with suitable mounting base plate having provision for fixing of optimised pulse rod and arrangement for down conductor of lightening protection system all as specified and directed by Engr-in-Charge.Make:- Cat Part No MAST 2M30 of ABB or its equvalent in Alstom/OBLUM
Supply, fixing, testing and commissioning of lightening stroke counter working electro mechanically without any power supply. Eqpt should have capacity of counting lighting stroke of 0.4 KA to 150 ka, all as specified and directed by Engr-in-Charge. Make- LS Counter of ABB or its equivalent in Alstom/Oblum
Supply and laying of single core multi stranded copper cable down conductor of size 70 sqmm incl mounting accessories and clamps with suitable fixing material all as directed at site.
Supply & installation of of G I Strip of size 32 mm X 6 mm as a ring conductor network buried in earth 1 mtr below from surface all as directed at site by Engr-in -charge
Supply & Installation of Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and directed by Engr-in -charge
SANJOLI CONSTRUCTION COMPANY
M/s R K Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .