Loading…
Loading…
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹34.8 L
EMD Value
₹34,000
Closing Date
15 Oct 2026, 5:30 pm5d left
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
G.M, WATCO, Division, Brahampur
Office of the General Manager, WATCO, Division, Brahampur, Courtpetta, Ganjam 760004.
Supply and Installation of Chlorine, PH and Turbidity Analyser for raw water monitoring at Jagdalpur and Dakhinapur Water Treatment Plant under WATCO Division Brahmapur
2026_WDBAM_142951_1
WATCOBAM- 11/2026-27 Dt. 29.09.2026
National Competitive Bid
Civil Works - Water Works
Percentage
120 days
Jagadalpur and Dakhinapur
Please refer Tender documents.
3 documents required · 3 mandatory
₹7,080
₹34,000
Yes
8 Oct 2026
8 Oct 2026
16 Oct 2026
8 Oct 2026
15 Oct 2026
8 Oct 2026
8 Oct 2026 - 14 Oct 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.01 | Supply, installation, testing & commissioning of water quality monitor for residual chlorine in distribution network, the imput power supply should be internal battery (2 of LSH 20 3.6V High Discharge lithium battery with communication and data logging through GPRS modem, website, RS 232 link to PC, RS 232 link to bluetooth dongle to mobile device, storage of upto 55000 data points in the device and having electrical connections 1X 9way fischer socket yellow(102) style for RS 232/bluetooth dongle, 1x 5way fischer socket (103)style for chlorine sensor, 1X 9Way fischer socket red (102) style for External device, 1X 7 Way fischer socket Grey (102) style for external device having environmental protection 1P68 to 1m the analyser is designed to fit withing standard Hydrant Chamber with minimum of 300mm between the Hydrant outlet to the underside of the chamber lid-150mm (w) x 164mm (h) weight including laying of connecting UPVC pipe Sch-80 & power supply arrangements etc. complete as per requirement & direction of Engineer-in-charge (Make ABB/ E&H/ Forbes Marshall) | 4 | each | 4,08,000 | ₹16,32,000 |
| 1.02 | Supply, installation, testing with technical specification PH sensor (DPC 1R1A) Accuracy less than 0.1 PH under reference conditions body material-PPS, Electrode material; General purpose glass pH electrode, Flow 0.2m/s )0-6.6 ft/s); non-abrasive operating temperature range; 0-105O C, pressure range;0-6.9 bar at 100O C (0-100psig at 212O F) Range; combination pH sensors 0-14pH sensor cable; integral coaxial cable (plus two conductors for temperature compesator option); 4.5m (15ft) long sensor thread;0.75", Temperature compensation; Pt 1000ohm RTD includes; sensor with 15ft cable digital gateway, 3ft digital extension cable and manual (ABB/E&H/Forbes Marshall) | 4 | each | 90,000 | ₹3,60,000 |
| 1.03 | Supply & Installation of Turbidity at analyser for online monitoring of turbidity in raw clear water with following technical specification i.e. sensor type optical nephelometer turbidity and suspended solids sensor rating-IP68, Range-0 to 4000 NTU. Accuracy 2% measured value, Display resolution-0.001 NTU, operating pressure upto 10bar (145psi) power 100mA@24V DC (ABB/E&H/Forbes Marshall) | 4 | each | 3,71,000 | ₹14,84,000 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.34 MB
DTCN11.pdf
Tender Documents • 1.05 MB
BOQ_612951.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .