| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L 1₹17.1 LAccepted-AOC | L 1 | Accepted-AOC Due to lowest tender | |
| 2 | L 2₹21.0 L+₹3.3 L (18.9%)Rejected-Finance | L 2 | Rejected-Finance Rejected being not lowest | |
| 3 | L 3₹21.3 L+₹3.7 L (20.7%)Rejected-Finance CHATHANATTU HOUSE XXIII 362B 1 AYYANKALI ROAD EDAKOCHI KOCHI 682 010 | KOCHI | ERNAKULAM | KERALA | 682010 | L 3 | Rejected-Finance Rejected being not lowest | |
| 4 | L 4₹21.5 L+₹3.9 L (22.2%)Rejected-Finance | L 4 | Rejected-Finance Rejected being not lowest | |
| 5 | L 5₹22.5 L+₹4.9 L (27.8%)Rejected-Finance | L 5 | Rejected-Finance Rejected being not lowest |
Tender Value
₹32 L
EMD Value
₹64,000
Closing Date
18 Sept 2020, 6:00 pmClosed
GARRISON ENGINEER(NW)KOCHI
GARRISON ENGINEER(NW)KOCHI, MILITARY ENGINEER SERVICES, NAVAL BASE POST, KATARIBAGH, KOCHI-682004.
COMPREHENSIVE MAINTENANCE AND PETTY REPAIRS OF INTERNAL WIRING, ELECTRICAL FITTINGS AND FIXTURES OF K, L AND M AREAS AT NAVAL BASE KOCHI
2020_MES_370944_1
GE(NW)KOCHI/8465/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
KOCHI
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE(NW)KOCHI
₹64,000
Yes
4 Nov 2020
21 Aug 2020
22 Sept 2020
21 Aug 2020
18 Sept 2020
4 Sept 2020
Amount
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendents, regulators. sockets etc to be measured separately) and making good the disturbed surfaces of walls. floors etc to match with the existing all as specified and directed.
Material and labour for point wiring with 1. 5 Sqmm PVC insulated (FRLSH) sheathed multistranded single core copper conductor cable in PVC casing and caping of suitable size and including 2mm thick MS sheet pressed terminal box (concealed) with 3mm thick laminated hylam top cover/sunken box with modular cover plate/PVC box as per requirement at site including 1.5 Sqmm PVC insulated (FRLSH) multistranded copper conductor earth continuity wire for one light/fan point controlled by one 5 Amp switch on independent board all as specified and as directed by the Engineer-in-Charge. Note : Red/yellow/blue coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board.
All as per item No.2 above, but one bell point controlled by one bell push on independent board.
All as per item No.2 above, but one 5 pin 5 Amps socket outlet on independent board.
All as per item No 2 above but with 2.5sqmm PVC insulated unsheathed stranded copper conductor with 2.5 sqmm PVC (FRLSH) insulated stranded copper wire for continuous earthing for one 5 pin 15 amps socket outlet point on independent board
S&F in repairs, bell push, flush type, 5 Amps, single pole complete all as specified and directed.
S&F in repairs, electric bell, 230 volt, flush type, 5 Amps, single pole complete all as specified and directed.
S & F in repairs switch piano flush type 5 Amps SP one way all as specified and directed.
S & F in repairs switch piano flush type 15 Amps SP one way all as specified
S & F in repairs, socket outlet, 5 Amps, 5 pin, 2 in 1, all as specified and as directed by the Engineer-in-Charge
S & F in repairs, socket outlet, multi-purpose, 5 and 15 Amps, 5 pin, 2 in 1, all as specified and as directed by the Engineer-in-Charge
S & F in repairs, switch socket outlet combination, 5 Amps, 5 pin, 2 in 1, all as specified and as directed by the Engineer-in-Charge
S & F in repairs, switch socket outlet combination, 5 and 15 Amps, 5 pin, 2 in 1, all as specified and as directed by the Engineer-in-Charge
S & F in repairs,step type electronic fan regulator, flush type, 100 W, 230 V all as specified and directed
S & F in repairs, capacitor 2.5 MFD for ceiling fans, all as specified and directed
S & F in repairs, lamp holder, PVC/Ploycarbonate type with back plate suitable for batten fittings, all as specified and directed
S & F in repairs, ceiling rose surface bakelite 65 x 50mm, 3 terminals all as specified and as directed by the Engineer-in-Charge
M&L in repairs for submain wiring with 2 runs of 4 Sqmm PVC insulated unsheathered multi stranded FRLSH copper conductor cable and one run of 4 Sqmm cable as earth continuity wire in and including PVC casing and caping and making good the disturbed surface to match with exisitng surface all as specified. Note : (i) Three runs of 4 Sqmm PVC cable and one run of PVC casing and caping will be measured as one unit length.(ii) The wiring shall be done in proper colour coding using red, yellow and blue for phase, black for neutral and green for earth leads.
All as per item No 18 above but with 2 runs of 2.5sqmm PVC insulated unsheathed stranded copper conductor with 2.5 sqmm PVC (FRLSH) insulated stranded copper wire for continuous earthing.
S & F in repairs triple pole and neutral sheet metal enclosure for MCB DB 8 ways, double door, 240 V, with 200 Amps bus bar having IP-43 protection complete all as specified
S & F in repairs single pole and neutral sheet metal enclosure for MCB DB 8 ways, double door, 240 V, with 200 Amps bus bar having IP-43 protection complete all as specified
S & F in repairs single pole and neutral sheet metal enclosure for MCB DB 4 ways, double door, 240 V, with 200 Amps bus bar having IP-43 protection complete all as specified
S & F in repairs, MCB TPN 63 Amps, 415 V, B curve, having breaking capacity 10 KA complete all as specified and directed.
S & F in repairs, MCB TP 63 Amps, 415 V, B curve, having breaking capacity 10 KA complete all as specified and directed.
S & F in repairs, MCB TPN 32 Amps, 415 V, B curve, having breaking capacity 10 KA complete all as specified and directed.
S & F in repairs, MCB SPN 63 Amps, 415 V, B curve, having breaking capacity 10 KA complete all as specified and directed.
S & F in repairs, MCB SP, 6-32 Amps, 415 V, B curve, having breaking capacity 10 KA complete all as specified and directed.
S & F in repairs, MCB SPN, 6-32 Amps, 415 V, B curve, having breaking capacity 10 KA complete all as specified and directed.
S & F in repair 20 watt LED tube double side with batten , 230V,50 Hz,wall surface ,roof surface including connected accessories including provision of flexible copper wire from ceiling rose to light fitting terminal complete all as specified and directed.(Note: Fitting shall be as per cat part no -,LGT8-20-865-2(Tube) and DIJB12LT8-20(Batten) of Crompton or equivalent make of Philips/Surya/Havellls) .
S & F in repair Led glass T8 tube 20 watt, 220 volt ,50 Hz instant LED tube rod, double side connection,inbuilt driver , complete all as specified.(Note: Fitting shall be as per cat part no -LGT8-20-865-2 of Crompton or equivalent make of Philips/Surya/Havells) .
S & F in repair LED light fitting 20 W, high performance batten , 220 volt ,50 Hz, surface mounted high quality aluminium extruded with all connecting accessories ,with suitable connection complete all as specified.(Note: Fitting shall be as per cat part no-LDL-20-CDL of Crompton or equivalent make of Philips/Surya/Havells .
S & F in repair LED light fitting 10 W, high performance batten , 220 volt ,50 Hz, surface mounted high quality aluminium extruded with all connecting accessories ,with suitable connection complete all as specified.(Note: Fitting shall be as per cat part no-LDL-10-CDL of Crompton or equivalent make of Philips/Surya/Havells) .
S & F in repair Modular Bell push 6A, 1module, complete all as specified.
S & F in repair Fan Regulator, modular electronic rotary,0-4 steps step type 100 Watt, 240 Volt 50 Hz hum free 2 module complete all as specified
S & F in repair switch modular 6 Amps 240 Volts one way switch complete all as specified.
S & F in repair Socket 6 Amps AC 240 Volts 2/3 pin combined 2 modular type complete all as specified.
S & F in repair Socket 6A/16 Amps-2/3 pin combined AC 240 Volts modular type complete all as specified.Make -Legrand/Havells/Honeywell.
S & F in repair Switch modular type AC 240 volts 16 Amps one way complete all as specified.
M & L in repair XLPE insulated, galvanised steel strip or wire armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, cross-sectional area 6 sq.mm 2 core including taking down old unserviceable cable complete all as specified.
M & L in repair XLPE insulated, galvanised steel strip or wire armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, cross-sectional area 10 sq.mm 4 core including taking down old unserviceable cable complete all as specified.
M & L in repair XLPE insulated, galvanised steel strip or wire armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, cross-sectional area 16 sq.mm 4 core including taking down old unserviceable cable complete all as specified.
M&L in repairs for submain wiring with 4 runs of 10 Sqmm PVC insulated unsheathered multi stranded FRLSH copper conductor cable and one run of 10 Sqmm cable as earth continuity wire in and including PVC casing and caping and making good the disturbed surface to match with exisitng surface all as specified. Note : (i) Five runs of 10 Sqmm PVC cable and one run of PVC casing and caping will be measured as one unit length.(ii) The wiring shall be done in proper colour coding using red, yellow and blue for phase, black for neutral and green for earth leads.
M&L in repairs for submain wiring with 4 runs of 16 Sqmm PVC insulated unsheathered multi stranded FRLSH copper conductor cable and one run of 16 Sqmm cable as earth continuity wire drawn through and including ISI marked, medium grade, non-metalic PVC conduit, white colour and all accessories and making good the disturbed surface to match with exisitng surface all as specified. Note : (i) Five runs of 16 Sqmm PVC cable and one run of PVC conduit will be measured as one unit length.(ii) The wiring shall be done in proper colour coding using red, yellow and blue for phase, black for neutral and green for earth leads.
All as per item No 43 above but with 2 runs of 1.5sqmm PVC insulated unsheathed stranded copper conductor with 1.5 sqmm PVC (FRLSH) insulated stranded copper wire for continuous earthing.
S & F in repair 15 watt square recessed mounted down lighter with high luminous LED for indoor application, 230V,50 Hz, minimum 100 lm/watt with all accessories and connection to the electric circuit complete all as specified and directed.(Note: Fitting shall be as per cat part no -LSCSM-15W-CDL of Crompton or equivalent make of Philips/Wipro) .
S & F in repair 15 watt recessed round down lighter with high luminous LED for indoor application, 230V,50 Hz, minimum 100 lm/watt with all accessories and connection to the electric circuit complete all as specified and directed.(Note: Fitting shall be as per cat part no -LSCRM-15W-CDL of Crompton or equivalent make of Philips/Wipro) .
S&F in repairs, focus light 07 watt ,230 volts,50 Hz, with all accessories and connection to the electric circuit complete all as specified .(Note: Fitting shall be as per cat part no -LSP07 of lukar or equivalent make of Philips/Crompton/Wipro).
S&F in repairs, ball bearing made out of high carbon steel, equivalent to the original, suitable for any type, any make, any size fans all as directed.
S&F in repairs, bush bearing made out of brass alloy, equivalent to the original, suitable for any type, any make, any size fans all as directed.
S&F in repairs, nickel plated mild steel clamps, nuts, bolts, washers and split pin suitable for ceiling fans, any type, any make, any size all as directed.
S&F in repairs, down rod, suitably threaded and holed, made out of 15mm dia GI tube, duly painted, 450mm long, suitable for ceiling fans, any type, any make, any size all as directed.
S&F in repairs, fan canopy with tightening screw/check nut, made out of PVC, suitable for ceiling fans, any type, any make, any size all as directed.
S&F in repairs, rubber reel insulator,suitable for ceiling fans, any type, any make, any size all as directed.
M&L for hanging hook for ceiling fan with nuts, bolts and washers minimum thickness 5mm all as directed.
S&F in repairs, fan blades for 1200mm sweep fan, made out of 1.2mm thick aluminium alloy and MS screws, duly balanced, white or brown colour, set of three, suitable for ceiling fans of any type and make, all as directed.
S&F in repairs, fan blade, set of three, made out of Acrylic/PVC and MS screws, duly balanced, suitable for 450/400mm sweep wall fans of any type and make, all as directed.
S&F in repairs, fan blade, set of three, made out of 1.2mm thick aluminium alloy and MS screws, duly balanced & spray painted with approved colour, suitable for 250/300mm sweep exhaust fans of any type and make, all as directed.
S&F in repairs, fan blade, set of three, made out of 1.2mm thick aluminium alloy and MS screws, duly balanced & 450mm sweep exhaust fans of any type and make, all as directed.
Taking down unserviceable ceiling fan of 1200mm/1400mm sweep, cutting out the existing burnt out fan motor winding, cleaning the motor slots, rewinding the motor with insulated copper winding wire of existing gauge, baking / heating up the motor to achieve the proper insulation resistance and re-hanging / refixing after repair including applying a coat of synthetic enamel paint (Glossy Finish) with spray gun, marking MES No complete all as specified.
Taking down unserviceable exhaust fan of 450/300/250 mm sweep, cutting out the existing burnt out fan motor winding, cleaning the motor slots, rewinding the motor with insulated copper winding wire of existing gauge, baking / heating up the motor to achieve the proper insulation resistance and re-hanging / refixing after repair including applying a coat of synthetic enamel paint (Glossy Finish) with spray gun, marking MES No complete all as specified.
Taking down unserviceable wall mounted fan of 400 /450 mm sweep, cutting out the existing burnt out fan motor winding, cleaning the motor slots, rewinding the motor with insulated copper winding wire of existing gauge, baking / heating up the motor to achieve the proper insulation resistance and re-hanging / refixing after repair including cleaning of fan complete all as specified.
M & L in repair Earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanized iron wire 4mm dia as earth up to 7.5 m distance and connected by means of bolts, nuts, checknuts and washers of galvanised iron or steel all shown in electric plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including provision of necessary excavation and earth work in any type of soil, PCC 1:3:6 type C1 pit , RCC 1:2:4 type B1cover 50 mm thick, reinforced with 8 mm dia TMT bars both ways @ 10 CM c/c , 20 mm bore medium grade watering pipe, water funnel, 40 mm bore GI medium grade protection pipe, common salt, charcoal dust, returning, filling in of soil, removal of spoil to a distance not exceeding 50 mtr etc including testing on completion complete all as specified and directed. Note :- (i) The unit rate shall deem to include for protection pipe and earth lead upto 7.50 Mtr. (ii) Earth lead beyond 7.50 Mtr length shall be measured and paid separately.
S & F in repair sunken box with Modular white cover plate 2/3 module with removing old type sunken boxes /wooden board and match with existing surfaces , complete all as specified.
S & F in repair sunken box with Modular white cover plate 4 module with removing old type sunken boxes /wooden board and match with existing surfaces , complete all as specified.
S & F in repair sunken box with Modular white cover plate 6 module with removing old type sunken boxes /wooden board and match with existing surfaces , complete all as specified.
S & F in repair sunken box with Modular white cover plate 8 module with removing old type sunken boxes /wooden board and match with existing surfaces , complete all as specified.
S & F in repair sunken box with Modular white cover plate 12 module with removing old type sunken boxes /wooden board and match with existing surfaces , complete all as specified.
Fixing only wall mounted fan of any size and connecting up including provision of cable from connector to fan .all as specified and directed. Note: Wall mounted fan will be issued under Schedule B free for fixing.
S & F in repair SPN enclosure with two pin and earth plug and socket complete with one SP MCB, 20 Amps having breaking capacity 10 kA, including taking down old unserviceable eath plug complete all as specified.
S & F in repair triple pole enclosure with three pin and earth plug and socket complete with one TP MCB, 20 Amps having breaking capacity 10 kA, including taking down old unserviceable eath plug complete all as specified.
S & F in repair Blaze highbay Led light 80 Watt ,240 volt , min lmumens 110 Lm/w ,IP 65 including provision of flexible copper wire from ceiling rose to light fitting terminal complete all as specified and directed.
S & F in repair 80 Watt LED Flood Light having IP-66 protection, 220 volts ,50Hz,pressure die cast aluminium housing, high luminious efficacy and high power complete all as specified.
Checking of ceiling fans stability (like fan hooks,nuts, bolts ,hanging rod ,canopy ,washer etc ) exhaust fan stability ,loose connection in destribution boards,MCBs in qtrs all as specified and directed by Engineer-in-Charge. Note - 1. The material incorperated for completion of work will be measured and paid seperately under relevent item. 2. The contractor should prepare a register and enter qtr number with signature of occupant and submit to Engineer-in-Charge. 3. Checking of all fans and DBs in a qtr at a time shall be considered as one job.
Checking of ceiling fans stability (like fan hooks,nuts, bolts ,hanging rod ,canopy ,washer etc ) exhaust fan stability ,loose connection in destribution boards,MCBs in office area all as specified and directed by Engineer-in-Charge. Note - 1. The material incorperated for completion of work will be measured and paid seperately under relevent item. 2. The contractor should prepare a register and enter office name with signature of offce incharge and submit to Engineer-in-Charge. 3. Checking of 7 fans and 2 DBs of any type at a time shall be considered as one job
M & L for checking of faulty / jumped energy meter (three phase /single phase ) with fixing of new energy meter in series and after one week submmit meter reading report of both energy meter in Engineer-in-Charge office all as specified and directed by Engineer-in-Charge.
S&F in repair MCCB enclosure 4 pole with 63 amp MCCB 4 pole,10 ka ,50 Hzs ,suitable for isolation power supply with suitable connection , all as specified and directed by engr in charge .cat part no -811985 (enclosure ) and 830715 ( MCCB ) of indoasian
Supply & fix in repairs, recess mounted/surface mounted commercial luminaire 36 watt ,50 Hz ,220 volts,5700 K LED down lighter 2'x2' , all as specified and directed of Crompton ,Philips ,Havells
S&F in repairs, wall mounted light 12 Watt (WH) 50 Hz, 220 Volts all as specified and directed. Note: Fitting shall be as per Cat Part No.LWL105 of Luker or equivalent make of Crompton/Philips.
S&F in repairs, wall mounted bulk head fitting 12 Watt (WH) 50 Hz, 220 Volts all as specified and directed. Note: Fitting shall be as per Cat Part No.LBKOVSL12 of Luker or equivalent make of Crompton/Philips.
Attending complaints for checking of existing items for continuous electric supply including carrying out minor repairs such as changing of fuse, small pieces of wires etc, carrying out repairs such as tightening of loosen electric connections, nuts,bolts, screws of switches, sockets, switch boards, fuse, replacefuse wire, providing small pieces of wires, making joints and covering with plasitc tape, minor repairs to ceiling fans/exhaust fans, cleaning and oiling etc as required to make the electrical items/appliances fully functional during all days any time including Sundays and Holidays by deploying a team of two Electrician/Wireman of skilled category alongwith two helpers of unskilled category (having mobile phone provided by contractor) including necessary T&P complete all as specified and directed. Notes:- (a) Replacement of electrical fittings shall be measured and paid for separately under respective items. (b) Number of complaints may vary daily and shall be as required basis. (c) The skilled worker shal be holding certificate in the trade of Electrical/Wiring from ITI or equivalent and having 5 years experience.Helpers shall be at least metric pass with two years experience in the field of Electrical Engineering works/wiring etc. (d) Complaints shall be notified to the contractor on phone and he shall be responsible for attending it within 2 hours and complation report given to the Engineer-in-Charge. (e) In case of failure on the part of contractor for not attending complaints or absence of any team member, a penalty @ Rs.500/- per complaint/Rs.1000/- per each team member will be recovered from the contractor.
Vidya constructions
ANIE JOHN CONTRACTORS
M/s ANTONY THOMAS AND CO
ELSOL ENGINEERS
AISWARYA ENTERPRISES
MS BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .