Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹33.0 LAccepted-AOC 777 AMAR NAGAR VILLAGE TOWN CITY RAE BARELI RAEBARELI UTTAR PRADESH 229001 INDIA | RAE BARELI | UTTAR PRADESH | 229001 | L-1 | Accepted-AOC Being L-1 | |
| 2 | L-2₹34.5 L+₹40,811 (1.20%)Rejected-Finance NIL | L-2 | Rejected-Finance Being L-2 | |
| 3 | L-3₹36.0 L+₹1.9 L (5.65%)Rejected-Finance GARRISON ENGINEER GE NORTH BINNAGURI | JALPAIGURI | WEST BENGAL | 735232 | L-3 | Rejected-Finance Being L-3 | |
| 4 | L-4₹36.6 L+₹2.5 L (7.45%)Rejected-Finance | L-4 | Rejected-Finance Being L-4 | |
| 5 | L-5₹36.7 L+₹2.7 L (7.82%)Rejected-Finance 234 4 JC BOSE ROAD KOLKATA | KOLKATA | WEST BENGAL | 700001 | L-5 | Rejected-Finance Being L-5 |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
4 Sept 2023, 6:00 pmClosed
GE NORTH BINNAGURI
GE North Binnaguri Post Binnaguri Dist Jalpaiguri West Bengal PIN - 735232
REPAIR/MAINTENANCE OF MCB DB, MCCB DB, SUBMAIN WIRING AND ALLIED ELECTRICAL FITTINGS/FIXTURES AT CENTRAL ZONE AREA AND REPAIR/REPLACEMENT OF LT FEEDER PILLAR BOXES, EARTHING WORK, CABLES AND CONNECTED WORKS AT MIL STN BINNAGURI UNDER GE (NORTH) BINNA
2023_MES_611944_1
NIT No. 8701 / 24 / 2023-24 / 07 / E8
Open Tender
Civil Works
Item Rate
270 days
BINNAGURI CANTONMENT
Class D Category b (i)
8 documents required · 8 mandatory
₹500
GE NORTH BINNAGURI
₹90,000
Yes
21 Oct 2023
3 Aug 2023
6 Sept 2023
3 Aug 2023
4 Sept 2023
19 Aug 2023
Amount
Taking down the existing unserviceable main switch/ cut out/ DBs of any type/ capacity/ description as existing at site including making good the disturbed surfaces to match with the existing finishes all as specified.
Taking down the existing unserviceable sub main wiring of any type / description as existing at site including making good the disturbed surfaces to match with the existing finishes all as specified.
M&L for sub main wiring with 2 run of 10.00 sqmm (nominal cross-sectional area) PVC insulated unsheathed single core FRLS cable of working voltage 1100 volts grade with stranded copper conductor including one run of 10.00 Sqmm (nominal cross sectional area) PVC insulated unsheathed cable with stranded copper conductor as continuous earth wire connected to common earth dolly drawn in 25mm dia PVC rigid non-metallic conduit with and including taking down unsv sub main, complete all as specified and as directed. Notes:- (i) PVC non rigid nonmetallic conduit shall be measured & paid separately under relevant item of this Schedule ‘A’. (ii) Two run of submain wiring cable along with one run of earth wire with and including PVC conduit pipe shall be measured as one unit length.
All as per item No 03 above but using two runs 6.0 Sqmm multistranded copper conductor single core cable with one run 6.00 sqmm multistranded copper conductor single core cable as earth wire complete all as specified and as directed.
All as per item No 03 above but using two runs 4.0 Sqmm multistranded copper conductor single core cable with one run 4.00 sqmm multistranded copper conductor single core cable as earth wire complete all as specified and as directed.
S&F in replacement of Sheet metal enclosures with socket two pin and earth plug top and MCB SP-20 Amp 230 volt complete all as specified and as directed.
S&F in replacement of MCB TPN 415 volts suitable for fixing in MCB DB of capacity 40 / 60 amps complete all as specified and as directed.
S&F Sheet metal enclosure for 4 way Distribution Boards (DB’s), double door, Triple pole & neutral with 200 amps rated bus bar, IP-20 protection suitable for fixing MCB"S/lsolators complete with and including taking down old unserviceable one complete all as specified and as directed.
S&F Sheet metal enclosure for 8 way Distribution Boards (DB’s), double door, single pole & neutral (SPN) with 200 amps rated bus bar, IP-20 protection suitable for fixing MCB"S/lsolators complete with and including taking down old unserviceable one a complete all as specified and as directed.
S&F MCB, Single pole & neutral,5 to 32 amps, 240 volts, ‘C’ curve, 10KA all complete with and including taking down old unserviceable one complete all as specified and as directed.
S&F MCB, Single pole & neutral, 35 to 63 amps, 240 volts, ‘C’ curve, 10KA all complete with and including taking down old unserviceable one complete all as specified and as directed.
S&F in replacement of MCB, SP, 6 to 32 Amps, 240 volts, ‘C’ curve, 10KA, 240 Volts to be housed in DBs including necessary connection complete all as specified and as directed.
S&F Moulded case circuit breaker (MCCB) four pole adjustable type 415 volts, 50 cycles ,100 Amps of breaking capacity 36 KA with and including taking down old unserviceable one complete all as specified and as directed.
Taking down existing unserviceable point wiring of any description/type/ size of light/fan/tube/power/two way/bell etc on TW batten/conduit including removal of batten/ conduit/ gutties/ wooden boards/ switches/ sockets/ regulators/ light fittings etc and separating the serviceable items like fan regulators and light fittings for re-use under respective items and removal of unserviceable material out of site and making good the disturbed surfaces of wall/ceiling so as to match with the existing finishes complete all as specified and as directed.
M&L for concealed conduit point wiring with 1.5 Sqmm (nominal cross-sectional area) PVC insulated unsheathed single core copper cable working voltage 1100 volts grade conforming to IS-694 with stranded copper conductor in and including PVC conduit of adequate size with all accessories (including cutting chases & making good the disturbed surface to its original specification) including MS sunk box, 3mm thick hylam sheet top cover fixed by means of brass machine screw and cap washer including size 1.5 sq mm (nominal cross sectional area) PVC insulated unsheathed single core multistranded copper conductor cable as earth continuity conductor connected to main switches/DB's or common earth dolly for one light point controlled by one, one way switch complete all as specified and as directed.
Description all as per item No 15 here in before but for one Ceiling Fan / exhaust fan point controlled by one, one way switch and regulator complete all as specified and as directed.
Description all as per item No 15 here in before but for one 3/5 pin 5 Amps switch socket outlet point controlled by one switch on the same board complete all as specified and as directed.
Description all as per item No 15 here in before but for one 3/5 pin 5 Amps switch socket outlet point controlled by one switch on independent board complete all as specified and as directed.
Description all as per item No 15 here in before but for one bell point controlled by one, bell switch 5 Amps complete all as specified and as directed.
Description all as per item No 15 here in before but for one light point controlled by one, two way switch 5 Amps complete all as specified and as directed.
Description all as per item No 15 here in before but using 2.5 sq mm single core copper conductor cable of multistranded flame retardant PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket combination point including running of 2.5 sq mm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common earth dolly complete all as specified and as directed.
S&F in repair switch piano flush type 5/6 amps single pole one way complete all as specified and as directed.
S&F switch piano flush type 5/6 amps single pole two way complete all as specified and as directed.
S&F socket 2 in 1, 5 Pin, 5/6 amps, white ivory finish flash type complete all as specified and as directed.
S&F socket outlet 2 in 1, 5 Pin 5/15 Amp multipurpose 230 volt flush type complete all as specified and as directed.
S&F in repair switch piano flush type 15/16 amps single pole one way complete all as specified and as directed.
S&F switch socket combination 2 and 3 Pin, 5/6 amps, multipurpose flush non shutter, non inter locking type white ivory finish with and including taking down existing unserviceable complete all as specified and as directed.
S&F switch socket combination 2 in 1, 6 pin 5/6 amps and 15/16 amps multipurpose, white/ivory finish flush non shutter non inter locking type with and including taking down existing unserviceable, complete all as specified and as directed.
S&F in repair ceiling rose, bakelite, surface type, 220/240 volts, three terminals complete all as specified and as directed.
S&F in repair modular switch 6 Amp one module complete all as specified and as directed.
S&F in repair modular Switch 16 Amp one module complete all as specified and as directed.
S&F Modular socket 6 Amp 2/3 Pin combined 2 module 230 volt flush type complete all as specified and as directed.
S&F Modular socket 6/16 Amp 2/3 Pin combined 2 module 230 volt flush type complete all as specified and as directed.
S&F in repair modular fan regulator 120W 230 volts AC 50 Hz 2 modules complete all as specified and as directed.
S&F in repair lamp holder, insulated body, with back plate suitable for batten/angle fittings complete all as specified and as directed.
S&F LED white glass Lamp 1x9/10 Watt 230V Base-22 complete all as specified and as directed.
S&F LED (warm) glass Lamp 1x9 Watt 230V Base-22 complete all as specified and as directed.
S&F in repair deluxe fan Electronic regulator 120/280 volts AC 50 Hzs rotary step white/ivory finish complete all as specified and as directed.
S&F in repair hylam sheet 3 mm thick white in colour of size 120 mm x 120 mm including taking down existing unserviceable complete all as specified and as directed.
S&F in repair hylam sheet 3 mm thick white in colour of size 120 mm x 170 mm including taking down existing unserviceable complete all as specified and as directed.
S&F in repair hylam sheet 3 mm thick white in colour of size 200 mm x 100 mm including taking down existing unserviceable complete all as specified and as directed.
S&F in repair hylam sheet 3 mm thick white in colour round type of size 80 mm dia including taking down existing unserviceable complete all as specified and as directed.
S&F in repair modular blank plates of 4 Module including taking down existing unserviceable complete all as specified and as directed.
S&F in repair modular blank plates of 6 Module including taking down existing unserviceable complete all as specified and as directed.
S&F in repair modular blank plates of 8 Module horizontal type including taking down existing unserviceable complete all as specified and as directed.
S&F wall mounted 4 feet LED light fittings 1 x 18/20 watts 230 Volt white powder coated slim box type (decorative) batten made of formed CRCA with snap on installer LED lighting fixture with and including 1x18/20 watt T8 Single side connection retrofit LED tube with G13 lamp holders, connector block, complete with all accessories internally pre-wired and including connecting up with three core twisted flexible copper conductor cable up to ceiling rose and taking down old unserviceable one complete all as specified and as directed.
S&F wall mounted 4 feet LED tube light(Warm) fittings 1 x 18/20 watts 230 Volt white powder coated slim box type (decorative) batten made of formed CRCA with snap on installer LED lighting fixture with and including 1x18/20 watt T8 Single side connection retrofit LED tube with G13 lamp holders, connector block, complete with all accessories internally pre-wired and including connecting up with three core twisted flexible copper conductor cable up to ceiling rose and taking down old unserviceable one complete all as specified and as directed.
S&F Energy saving new generation environmental friendly long life versatile pressure die cast aluminium IP 66 security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 25 watts with pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting and GI pipe bracket made out of GI pipe medium grade 32 mm dia 1.5 mtr long bend to required shape complete including removal of old unserviceable fitting complete all as specified and as directed..
S&F Energy saving new generation 10 watts LED bulk head fitting IP 65 luminaire with opel diffuser pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting including LED bulb and taking down old unserviceable one complete all as specified and as directed.
S&F in replacement wall mounted 2 feet LED 10 watts, batten type (decorative) light fitting, 230 volts with extruded aluminium heat sink provided for efficient heat dissipation and integrated electronic driver connector block etc complete with all accessories internally pre wired and necessary mounting arrangements including necessary connection and taking down old unserviceable one complete all as specified and as directed.
S&F Post top lanterns 15 watt LED light fitting ,new generation, energy saving, environmental friendly, long life with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source, spun aluminium canopy, with opal/clear acrylic diffuser and complete with all accessories internally prewired including connecting up with three core twisted flexible copper conductor cable up to ceiling rose and necessary mounting arrangements and taking down old unserviceable one complete all as specified and as directed.
Taking out old unserviceable cable of any size carefully from trenches ofter disconnecting electric connection, GI pipe protection, with and including separating serviceable bricks & set aside and removing un-serviceable bricks from site complete all as specified and as directed. Note : The Excavation and earth work shall be measured and paid separately under relevant item of Schedule.
Supply, laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulated PVC bedded, galvanized steel strip or wire armoured LT electric power UG cables, heavy duty with stranded aluminium conductor of cross sectional area 25 sqmm 4 core with and including all fixing & connecting accessories such as Alluminium cable lugs, cable gland, nut, bolts, washer etc complete all as specified and as directed.
All as per ser item No 53 above but of cross sectional area 120 sqmm 3.5 core complete all as specified and as directed.
All as per ser item No 53 above but of cross sectional area 400 sqmm 3.5 core complete all as specified and as directed.
Digging out incoming and outgoing cables of any sizes from loops near junction box/ feeder pillar box in trenches, cutting burnt out uninsulated portion of cable and relaying /refixing in trenches & returning, refilling the excavated soil and connecting the cables with bus bars including provision of suitable size of aluminium lugs complete all as specified and as directed.
Relaying in trenches or passing through pipe, 1100 volts grade, LT electric power UG cables, of any type/Size with and including all fixing & connecting accessories such as Alluminium cable lugs, cable gland, nut, bolts, washer etc complete as specified and as directed. Notes:- (a) Earthwork & Excavation, GI pipe, bricks for protection etc shall be measured and paid separately under relevant items of this schedule 'A'. (b) The serviceable cable obtained from taking out shall be reused.
S&F of moulded case circuit breaker (MCCB) four pole Adjustable type 415 volt, 50 Cycles, 63 Amps of breaking capacity 25 KA after and including taking down / dismantling of old existing unserviceable one complete all as specified and as directed.
S&F of moulded case circuit breaker (MCCB) four pole Microprocessor release type 415 volt, 50 Cycles, 100 Amps of breaking capacity 36 KA after and including taking down / dismantling of old existing unserviceable one complete all as specified and as directed.
S&F of moulded case circuit breaker (MCCB) four pole Microprocessor release 415 volt, 50 Cycles, 160 Amps of breaking capacity 36 KA after and including taking down / dismantling of old existing unserviceable one complete all as specified and as directed.
S&F of moulded case circuit breaker (MCCB) four pole Microprocessor release type 415 volt, 50 Cycles, 200 Amps of breaking capacity 36 KA after and including taking down / dismantling of old existing unserviceable one complete all as specified and as directed.
S&F of moulded case circuit breaker (MCCB) four pole Microprocessor release type 415 volt, 50 Cycles, 250 Amps of breaking capacity 36 KA after and including taking down / dismantling of old existing unserviceable one complete all as specified and as directed.
S&F of moulded case circuit breaker (MCCB) four pole Microprocessor release type 415 volt, 50 Cycles, 400 Amps of breaking capacity 36 KA after and including taking down / dismantling of old existing unserviceable one complete all as specified and as directed.
S&F in replacement of MCB, Triple pole & neutral 63 amps, 240 volts, ‘C’ curve, 10KA complete all as specified and as directed.
Excavation in trenches in soft/loose soil not exc. 1.5 meter wide and not exc. 1.5 meter in depth and getting out for taking up / laying under ground electric cable complete all as specified and as directed.
Returning, filling in, including spreading leveling watering and well ramming in layers not exceeding 25 cms in depth complete all as specified and as directed.
Removing surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and as directed.
Supply and lay dry river sand filling for under ground cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying complete all as specified and as directed.
Supply and laying sub class B bricks of size 23cmx12.5cmx7.5cm (+/-10% tolerance) for protection of UG cable with width equal to length of bricks as mechanical protection laid dry and flat complete all as specified and as directed.
Laying only Old bricks for protection of LT UG cable complete all as specified and as directed. Note: The serviceable bricks obtained from taking out cable shall be reused.
M&L for horizontal boring suitable upto 80mm steel tubing across the existing road without disturbing the road surface for inserting GI pipe complete all as specified and as directed. Notes :- (a) Removal of surplus soil shall be deemed to be include in the unit Rate. (b) GI pipe will be measured and paid separately under relevant item of Schedule 'A'.
M&L for 50 mm bore steel tubing light grade ISI marked for protection of cable including necessary joints complete all as specified and as directed.
M&L 80 mm bore steel tubing light grade ISI marked for protection of cable including necessary joints complete all as specified and as directed.
M&L for fabrication of shutter of LT panels/Feeder Pillars door with 14 gauge thick MS sheet of size 800 mm x 600 mm including welding, providing hinges, locking arrangements of suitable sizes as per site requirement complete all as specified and as directed.
M&L for fabrication of shutter of LT panels/Feeder Pillars door with 14 gauge thick MS sheet of size 1100 mm x 600 mm including welding, providing hinges, locking arrangements of suitable sizes as per site requirement complete all as specified and as directed.
Dismantling of old U/S LT feeder pillar box/LT junction box including PCC/Brick wks foundation after disconnecting of all electrical connection complete all as specified and as directed.
Supply, fabrication, installation and testing of LT out door type factory made ,CPRI Approved, junction box of size 900mmX600mmX400mm (over all dimension) made out of 3.15 mm thick CRCA sheet dully supported with mild steel angle iron of size 25X25X5mm vertical frame and legs with mild steel flat iron 25X5 mm in horizontal sides of the frame with front and back side openable ,single hinged door / shutter with locking arrangement and powder coated finish both internal and external steel surfaces after necessary preparation of steel surfaces including providing PCC (1:3:6) type C2 foundation of size 0.80m X 0.6m X 0.90m depth (0.30m below ground level and 0.60m above ground level ) and connections of all outgoing / incoming existing cable of any size drawing / digging out cable from loops in trenches inclusive of necessary excavation and earthwork as required and relaying the cables including the following fitment accessories all complete as specified and as directed. (a) Copper bus bar of size 600 Amp wrapped with PVC sleeves with maintained the colour code and provision of making holes as required with nuts, bolts & washers for cable connections including hydrographic insulators with nuts & bolts at both ends = 04 nos. (b) Enameled iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter of JB for LT -01 No.
Supply, fabrication, installation, testing and commissioning of LT 3 Phase 4 wire 450 Volts system, factory made, CPRI Approved, water and vermin proof protection pedestal type feeder pillar box of minimum size 1200 mm x 800 mm x 500 mm (overall) of out door type made out of 3.15 mm thick CRCA sheet with frame and legs of mild steel angle iron of size 40 x 40 x 6 mm in all side with double door, front and back side openable hinged door and air ventilation arrangement including provision of cable looping box of size 800 x 450 x 400 mm . Danger notice plate with letters, figures and conventional skull and bones in signal red and shall be fixed on main door. The panel shall be complete painted with Powder Coated paint of approved shade. "U" type gas ket shall be used to make the inner shell completely vermin proof to accommodate incomers/outgoing MCCBs. All interconnection between the main bus bar as well as out going feeders shall be carried out with TPN coppe bus bar of rating not less than 1.5 times the rated capacity of individual out going feeders and should be insulated with heat shreank cable PVC shleaves and shall be mounted on suitable size "F" class insulators. The degree of protection of outer shell of the panel shall be IP-65. A detachable pre drilled gland plate should be used at bottom. All control wire shall be with 2.5 sqmm multi stranded copper conductors and shall be properly brunched, tied, ferruled for proper identification and print with adequate size of lugs complete with and including PCC (1:3:6) type C-2 of size 0.80 m x 0.60 m x 1.05 m depth (45 cm below ground level and 60 cm above ground level) as in foundation in cement mortar 1:6 and plastering the same in cement mortar 1 : 6 finished even and smooth with out using extra cement complete including necessary excavation, earth work and including connecting all incoming and outgoing LT UG cables after drawing/ digging out cable from loops in trenches complete all as specified and as directed along with and including comprising of the following accessories : - Note : (i) Cost of earth work and PCC are deemed to be inclusive in this item (ii) The schematic diag of LT panels shall be approved by GE before procurement. (a) Incoming Copper busbar 600 Amps capacity including insulator with nuts & bolts-04 Nos (b) Outgoing Copper busbar 400 Amps capacity including insulator with nuts & bolts-04 Nos (c) MCCB 4 pole, 415 volts, 36 KA breaking capacity adjustable thermal magnetic release with Ics=100% Icu, neutral adjustment 100% of rating 250 amps including all fixing accessories with both ends spreader links . ( Incoming -01 Nos) (d) Iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm, white with letters, figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter of FPB for LT -01 No.
M&L for preparation of the old decorated existing external steel surface of feeder pillar boxes/LT panels /JBs of any size and description in any position including removal of disintegrated & deteriorated paint either by hand scrapping or by blow lamps, applying necessary filler coat and stopping required and applying two coats of Asian aspa paint (Mahindra Grade) by using spray painting machine on old prepared surface including marking of Sub Stn No, Feeder No and feeding area/Bldg with applying synthetic enamel paint (1st grade) complete all as specified and as directed.
S&F in repairs LED indicating RED lamp, including necessary connection complete all as specified and as directed.
S&F in repairs LED indicating YELLOW lamp, including necessary connection complete all as specified and as directed.
S&F in repairs LED indicating BLUE lamp, including necessary connection complete all as specified and as directed.
S&F in repairs CT coil 100/5 Amps including necessary connection complete all as specified and as directed.
S&F in repairs danger notice board / plate of size 20 cm x 15 cm, made out of 1.6 mm thickness mild sheet, vitreous enameled white letters, figure and conventional skull and bones in Red colour and fixed with nuts and bolts for 1100 volts current complete all as specified and as directed.
Cutting unaxious green growth and wild grass by manual labour or by machine at Electrical Installation Premises around pole, around panel board along boundaries fencing, removing runnish material from work site and depositing where directed not exc. 100 meter from the starting point complete all as directed. Note : The item shall be operated maximum 2 (Two) times in the entire period of the Contract period and measurement will be taken every time independently for payment.
S&F aluminium strip of size 25x3 mm for earth continuity conductor fixed on PCC block complete all as specified as directed.
S&F Copper strip of size 20x3 mm for earth continuity conductor fixed on PCC block complete all as specified and as directed.
Dismantling of existing unserviceable loose/disturbed Aluminum strip/GI Strip/Copper strip/Termination rod of any sizes on roof/down conductor fixed on wooden guities /directly on roof including screws etc complete all as specified and as directed.
S&F in repairs for 32 x 6 mm galvanised iron strip, earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or fixed to poles or roof with saddle and screw current complete all as specified and as directed.
S&F porcelain insulator of size 65x31 mm and height 30mm with three nos hole including GI bolts and nuts of required size and two nos washer on PCC, fixing strip complete all as specified and as directed.
S&F air termination single pointed aluminium rod 12mm dia and 300 mm height/length complete all as specified and as directed.
M&L for PCC work by providing PCC type C1 (1:3:6) with 20mm graded stone aggregate in foundation for panel and finishing the surface even and smooth without using extra cement including breaking of old PCC.
Disconnecting electric connection and Taking down of all UG cable from LT Panel/JB of any capacity and model removing of unserviceable spares / accessories for repair/replacement of the same including reconnection of all UG Cable connection with suitable lugs ,nuts & bolts etc to existing LT Panel/JB and testing complete all as directed. Note:- Suitable Lugs, Nuts & Bolts shall be deemed to be in quoted rate.
M&L for Earthing complete with Copper earth plate electrode 600x600x3.15 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below the ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level, connected to Copper earth strip 20x3 mm dia by means of bolts, nuts, check nuts and washers of brass/copper all as shown in electrical plate No 3 of SSR part-I 2009 connected to lightening conductor all as specified and testing on completion including. Necessary excavation, earthwork, PCC works and CI earth pit cover with watering pipe 20mm dia GI pipe medium grade, funnel with wire mesh and lugs and GI pipe 40 mm dia of light grade, for protection of earth strip including dismantling of old earthing complete all as specified and directed. Note: Excavation/PCC/Earth work/Charcoal/ Salt shall be deemed to be include in this unit rate.
M&L for Earthing complete with galvanised steel earth plate electrode 600x600x6.0 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below the ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level, connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or of steel all as shown in electrical plate No 3 of SSR part-I 2009 connected to pole/LT Panel all as specified and testing on completion including. Necessary excavation, earthwork, PCC works and CI earth pit cover with watering pipe 20mm dia GI pipe medium grade, funnel with wire mesh and lugs and GI pipe 40 mm dia of light grade, for protection of earth strip including dismantling of old earthing complete all as specified and as directed. Note: Excavation/PCC/Earth work/Charcoal/ Salt shall be deemed to be include in this unit rate.
M&L for Earthing complete with galvanised steel earth plate electrode 600x600x6.0 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below the ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level, connected to galvanised earth strip 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or of steel all as shown in electrical plate No 3 of SSR part-I 2009 connected to pole/LT Panel all as specified and testing on completion including. Necessary excavation, earthwork, PCC works and CI earth pit cover with watering pipe 20mm dia GI pipe medium grade, funnel with wire mesh and lugs and GI pipe 40 mm dia of light grade, for protection of earth strip including dismantling of old earthing complete all as specified and as directed. Note: Excavation/PCC/Earth work/Charcoal/ Salt shall be deemed to be include in this unit rate.
SHRI PRADEEP PARIK
Shri Amarnath Sah
M/S S.K.DAS
M/S SARKAR BROTHERS
BBKundu
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .