Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.5 LAccepted-AOC | L1 | Accepted-AOC Contract is awarded to M/s Azad Services | |
| 2 | L2₹41.6 L+₹61,366 (1.50%)Rejected-Finance | L2 | Rejected-Finance Rejected being other than lowest quoted rate | |
| 3 | L3₹42.8 L+₹1.9 L (4.53%)Rejected-Finance | L3 | Rejected-Finance Rejected being other than lowest quoted rate | |
| 4 | L4₹44.9 L+₹3.9 L (9.65%)Rejected-Finance PLOT NO 76 CIV SOCIETY MUKUND NAGAR AHMEDNAGAR 414001 | AHMEDNAGAR | AHMEDNAGAR | MAHARASHTRA | 414001 | L4 | Rejected-Finance Rejected being other than lowest quoted rate | |
| 5 | L5₹46.0 L+₹5.0 L (12.3%)Rejected-Finance | L5 | Rejected-Finance Rejected being other than lowest quoted rate |
| Sl No | Description | Qty | Unit | BHAVIN INFRA L6 | vedant engineering enterprises L2 | KAMINS CARE L7 | M/s. N D Karande L5 | M/s AG PATHAN L3 | AZAD SERVICES L1 | HG PATHAN CONSTRUCTION COMPANY L4 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches not exc 1.5m wide and not exc 1.5m in depth for foundation, laying cables, etc and not exc 10 Sqm on plan and getting out in any kind of soil complete all as specified as directed. | 894 | Cum | 210 ₹1,87,740 | 190 ₹1,69,860 | 200 ₹1,78,800 | 218 ₹1,94,892 | 195 ₹1,74,330 | 180 ₹1,60,920 Lowest | 200 ₹1,78,800 |
| 2.00 | Excavation in trenches not exc 1.5m wide and exc 1.5m but not exc 3m in depth for foundation, laying cables, etc and not exc 10 Sqm on plan and getting out in any kind of soil complete all as specified as directed. | 4 | Cum | 270 ₹1,080 | 250 ₹1,000 Lowest | 280 ₹1,120 | 400 ₹1,600 | 255 ₹1,020 | 300 ₹1,200 | 350 ₹1,400 |
| 3.00 | Returning, filling in excavated material (soil) including spreading, levelling, watering and well ramming in layers not exc 25 cm all as specified and as directed. | 704 | Cum | 28 ₹19,712 | 18 ₹12,672 | 30 ₹21,120 | 26 ₹18,304 | 15 ₹10,560 Lowest | 20 ₹14,080 | 25 ₹17,600 |
| 4.00 | Removing excavated material (soil) to a distance not exc 50m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and as directed. | 190 | Cum | 38 ₹7,220 | 22 ₹4,180 | 35 ₹6,650 | 26 ₹4,940 | 20 ₹3,800 Lowest | 20 ₹3,800 Lowest | 25 ₹4,750 |
| 5.00 | Supply and laying Double Walled Corrugated (DWC) HDPE pipe of nominal bore 50mm including 90 degree bends with coupler and rubber ring, conforming to IS :16205 Part 24 Type 450N, laid in trenches for cable protection complete, all as specified and as directed. | 1,500 | RM | 63 ₹94,500 | 58 ₹87,000 | 65 ₹97,500 | 70 ₹1,05,000 | 65 ₹97,500 | 55 ₹82,500 Lowest | 60 ₹90,000 |
| 6.00 | Supply and laying Double Walled Corrugated (DWC) HDPE pipe of nominal bore 63mm including 90 degree bends with coupler and rubber ring, conforming to IS :16205 Part 24 Type 450N, laid in trenches for cable protection complete, all as specified and as directed. | 700 | RM | 88 ₹61,600 | 68 ₹47,600 Lowest | 90 ₹63,000 | 94 ₹65,800 | 72 ₹50,400 | 75 ₹52,500 | 80 ₹56,000 |
| 7.00 | Supply and laying Double Walled Corrugated (DWC) HDPE pipe of nominal bore 110mm including 90 degree bends with coupler and rubber ring, conforming to IS :16205 Part 24 Type 450N, laid in trenches for cable protection complete, all as specified and as directed. | 700 | RM | 235 ₹1,64,500 | 190 ₹1,33,000 Lowest | 240 ₹1,68,000 | 220 ₹1,54,000 | 194 ₹1,35,800 | 200 ₹1,40,000 | 200 ₹1,40,000 |
| 8.00 | Taking out existing LT UG XLPE cable of size 240 sqmm, 3.5 core from trenches/poles etc, alongwith protection covers all as specified and as directed.
Note :- Excavation and earthwork shall be measured and paid separately. | 30 | RM | 48 ₹1,440 | 30 ₹900 | 50 ₹1,500 | 40 ₹1,200 | 32 ₹960 | 25 ₹750 Lowest | 30 ₹900 |
| 8.10 | All as per serial item No 8.00 here-in-before but cross sectional area 185 sq mm, 3.5 core. | 30 | RM | 45 ₹1,350 | 25 ₹750 | 50 ₹1,500 | 40 ₹1,200 | 24 ₹720 | 20 ₹600 Lowest | 30 ₹900 |
| 8.20 | All as per serial item No 8.00 here-in-before but cross sectional area 150 sq mm, 3.5 core. | 300 | RM | 28 ₹8,400 | 22 ₹6,600 | 30 ₹9,000 | 40 ₹12,000 | 24 ₹7,200 | 20 ₹6,000 Lowest | 28 ₹8,400 |
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
6 Oct 2025, 6:00 pmClosed
Shri Milind Mulik, (AE QS and C)
Military Engineer Services, Garrison Engineer (South) Ahilyanagar - 414002
REPAIR / REPLACEMENT OF LT POLES, ACSR CONDUCTORS, STREET LIGHT FITTINGS, PANEL BOARDS CABLES AND MISC E/M WORKS AT MIC AND S UNDER GE (S) AHILYANAGAR
2025_MES_731094_1
8260/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Ahilyanagar
Class D Cat b(i)
8 documents required · 8 mandatory
₹500
Garrison Engineer (South) Ahilyanagar
₹84,000
Yes
29 Jan 2026
16 Sept 2025
8 Oct 2025
16 Sept 2025
6 Oct 2025
30 Sept 2025
16 Sept 2025 - 23 Sept 2025
Amount
Excavation in trenches not exc 1.5m wide and not exc 1.5m in depth for foundation, laying cables, etc and not exc 10 Sqm on plan and getting out in any kind of soil complete all as specified as directed.
Excavation in trenches not exc 1.5m wide and exc 1.5m but not exc 3m in depth for foundation, laying cables, etc and not exc 10 Sqm on plan and getting out in any kind of soil complete all as specified as directed.
Returning, filling in excavated material (soil) including spreading, levelling, watering and well ramming in layers not exc 25 cm all as specified and as directed.
Removing excavated material (soil) to a distance not exc 50m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and as directed.
Supply and laying Double Walled Corrugated (DWC) HDPE pipe of nominal bore 50mm including 90 degree bends with coupler and rubber ring, conforming to IS :16205 Part 24 Type 450N, laid in trenches for cable protection complete, all as specified and as directed.
Supply and laying Double Walled Corrugated (DWC) HDPE pipe of nominal bore 63mm including 90 degree bends with coupler and rubber ring, conforming to IS :16205 Part 24 Type 450N, laid in trenches for cable protection complete, all as specified and as directed.
Supply and laying Double Walled Corrugated (DWC) HDPE pipe of nominal bore 110mm including 90 degree bends with coupler and rubber ring, conforming to IS :16205 Part 24 Type 450N, laid in trenches for cable protection complete, all as specified and as directed.
Taking out existing LT UG XLPE cable of size 240 sqmm, 3.5 core from trenches/poles etc, alongwith protection covers all as specified and as directed. Note :- Excavation and earthwork shall be measured and paid separately.
All as per serial item No 8.00 here-in-before but cross sectional area 185 sq mm, 3.5 core.
All as per serial item No 8.00 here-in-before but cross sectional area 150 sq mm, 3.5 core.
All as per serial item No 8.00 here-in-before but cross sectional area 120 sq mm, 3.5 core.
All as per serial item No 8.00 here-in-before but cross sectional area 95 sq mm, 3.5 core.
All as per serial item No 8.00 here-in-before but cross sectional area 70 sq mm, 3.5 core.
All as per serial item No 8.00 here-in-before but cross sectional area 50 sq mm, 3.5 core.
All as per serial item No 8.00 here-in-before but cross sectional area 35 sq mm, 3.5 core.
All as per serial item No 8.00 here-in-before but cross sectional area 25 sq mm, 3.5 core.
All as per serial item No 8.00 here-in-before but cross sectional area 16 sq mm, 4 core.
Supply and laying in trenches or fixing or passing through pipe, 1100 Volts grade, armoured, heavy duty LT UG cable of size 240 Sqmm, 3.5 core with XLPE insulated stranded aluminium conductor including cable gland, lugs, testing and commissioning complete all as specified and as directed.
All as per serial item No 9.00 here-in-before but cross sectional area 185 sq mm, 3.5 core.
All as per serial item No 9.00 here-in-before but cross sectional area 150 sq mm, 3.5 core.
All as per serial item No 9.00 here-in-before but cross sectional area 120 sq mm, 3.5 core.
All as per serial item No 9.00 here-in-before but cross sectional area 95 sq mm, 3.5 core.
All as per serial item No 9.00 here-in-before but cross sectional area 70 sq mm, 3.5 core.
All as per serial item No 9.00 here-in-before but cross sectional area 50 sq mm, 3.5 core.
All as per serial item No 9.00 here-in-before but cross sectional area 35 sq mm, 3.5 core.
All as per serial item No 9.00 here-in-before but cross sectional area 25 sq mm, 3.5 core.
All as per serial item No 9.00 here-in-before but cross sectional area 16 sq mm, 4 core.
All as per serial item No 9.00 here-in-before but cross sectional area 10 sq mm, 2 core.
M&L heat shrinkable straight through cable joint kit suitable for 10 to 16 Sqmm 4 core LT XLPE cable 1100 Volts grade complete with jointing material and accessories and testing including necessary excavation / earth work complete all as specified and as directed.
All as per serial item No 10.00 here-in-before but 25 to 50 sqmm 3.5 core
All as per serial item No 10.00 here-in-before but 70 to 120 sqmm 3.5 core
All as per serial item No 10.00 here-in-before but 150 to 185 sqmm 3.5 core
All as per serial item No 10.00 here-in-before but 240 sqmm 3.5 core
S&F in replacement 80 mm bore galvanised steel tubing, light grade, ISI marked, for protection of under ground cable on pole/wall/under road including clamps where reqd and taking out old unserviceable pipe complete all as specified and as directed.
All as per serial item No 11.00 here-in before but 50 mm bore
All as per serial item No 11.00 here-in-before but 40 mm bore
Supply and erection in replacement steel tubular swaged poles with MS base plate 6 mm thick of size 300 x 300 mm, finial tapper plug, bolts, nuts & screws as specified type 410 SP-31, 9.00 Mtr long, made out of ERW MS tubing conforming to IS-2713 Part II including drilling holes of required size for fixing cross arms etc erected in true vertical position, including one coat of red-oxide zinc chrome primer and two coats of aluminium paint on surfaces exposed to view and making 30cm wide strips (total 5 Nos) with yellow and black paint alternately on external surface above PCC benching and painting with bituminous paint internally including writing the pole number in white letters on black background complete and externally for portion embedded in PCC, complete all as specified and as directed. Note:- Excavation & earthwork and PCC in foundation of poles,coping etc shall be measured and paid under respective item.
Supply, install in replacement and testing out door wheather proof bus bar chamber of size 100 cm x 60cm x 30cm made out of 3.15mm CRCA MS sheet having one side openable hinged door shutter with locking arrangement/provn of two nos 80cm long 40x40x6mm anlge iron legs welded and 04 nos Aluminium bus bar of 200Amp rating provn of one MCCB TPN 100 Amp 25 KA for controlling Electric supply complete erected on ground with necessary PCC 1:3:6 type C2 foundation complete bus bar chamber painted with two coats of approved enamel paints over one coat of primer including making cable connection with necessary gland , lugs/thimbles complete all as specified and as directed.
M&L for PCC 1:2:4, type B1, using 20 mm graded stone aggregates as in coping of pole and similar work etc including necessary formwork and finishing even and smooth without using extra cement complete all as specified and as directed.
M & L PCC 1:3:6 type C2 using 40 mm graded stone aggregate for foundation of pole/stays complete all as specified and as directed by Engineer-in-Charge.
M&L in repairs/replacement earthing complete with galvanized steel earth plate electrode 60 cm X 60 cm X 6.0 mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level, connected to and including galvanized earth strip 25mmx4mm upto 7.5 m by means of bolts, nuts, check nuts and washers made of galvanised iron and protected by light grade 32mm dia GI pipe connected to main control board, including provision of concrete pit in PCC (1:2:4) type B-1 using 20 mm graded stone aggregates with 40 mm thick RCC (1:2:4) cover with reinforced with XPM (weight not less than 4 Kg / Sqm) and frame of angle iron 25mm X 25 mm X 3mm with lugs 2 Nos and with 6 mm dia MS bar handle made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, 15cm thick alternate layers of common salt and charcoal filling all around the plate, test point made out of phosphorus bronze with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding than 50 mtr, all as per electric plate No 3 of SSR Part I 2009 and connection to earth test point all as specified including testing on completion.
Dismantling of unserviceable steel structure such as cross arms, bracings, supports, clamps etc from LT pole of any type/shape complete all as specified and directed.
Supply and fixing Cable route indicator made out cast iron and embedded LT Cable on the plate of size 80 mm dia 5 mm thick and grouting lug of suitable size including grouted in PCC foundation of suitable size complete all as directed and directed by Engineer in Charge.
S&F in replacement, manual change over switch, 415 Volt, sheet metal enclosure, 4 Pole of capacity 63 Amps with connecting acessories complete all as specified and as directed .
S&F in replacement, manual change over switch, 415 Volt, sheet metal enclosure, 4 Pole of capacity 100 Amps with connecting acessories complete all as specified and as directed .
S&F in replacement, manual change over switch, 415 Volt, sheet metal enclosure, 4 Pole of capacity 200 Amps with connecting acessories complete all as specified and as directed .
M& stay assembly comprising of 16 mm dia stay rod, 1800 mm long, loop type insulator of size 65 mm x 90 mm, galvanised stay plate 6 mm thick of size 250 x 250 mm and stay bow & dismantling of old Stay assembly complete all as specified and directed & as shown in Electrical Plate No. 1 of SSR Pt I complete all as specified and as directed. Note : Excavation/earth work PCC shall be measured and paid seperately.
M&L for Galvanised stay strand 7/3.15 mm complete all as specified and directed by Engr in Charge.
Disconnecting of electric supply from over head line and removing existing binding wire and ACSR conductor and restringing of ACSR conductor including binding of conductor on insulator with new binding wire & reconnecting the electric supply complete all as specified and as directed by Engr-in-charge.
S&F line separators for two conductors complete all as specified and as directed.
S&F line separators for three conductors complete all as specified and as directed.
S&F line separators for four conductors complete all as specified and as directed.
S&F cross arms, bracings, support channel, backplate hooks etc fabricated from structural steel sections (MS angle, Channel) of required size and shape including nuts, bolts, washers, welding, bending, cutting cold or hot, drilling holes for inserting bolts as indicated and directed including painting with one coat of red oxide primer and two coats of silver aluminium paint complete all as specified and as directed by Engr-in-Charge.
S&F pin type porcelain vitreous brown/white insulator with approved make including one galvanised MS spindle two GI washers and GI nut of size 100 mm height and 65 mm dia 1100 Volt grade including taking out old unserviceable insulator complete all as specified and as directed.
S&F in repair shackle type porcelain vitreous brown/white insulator with approved make including galvanised MS strip washers, insulated bolts, washers nut of size 75 mm height 90 mm dia for 1100 volt grade including taking out of old unserviceable insulator complete all as specified and as directed.
S&F aluminium conductor steel reinforced, any size, (Weasel/ Ferret/ Squirrel as required) including stringing, binding, jointing, jumpering etc on insulators or on poles with minimum sag including dismantling old ACSR conductor from LT pole complete all as specified and as diercted.
Trimming of tree branches touching to the LT/HT over head line or near to the LT/HT over head line as per the direction of AGE E/M/JE incharge complete including removing the tree branches from site complete all as specified and directed. Note : (i) Written shut down shall be obtained from concerned JE/AGE (E/M) before taking the trimming work in hand by contractor. (ii) Span from one pole to next pole (30 to 50 RM) will be considered as a one Job. (iii) Any damage caused due to negligence of workmen shall be rectified by thecontractor without any extra payment. (iv) T & P such as ladder, rope, cutter, axes and other related materials shall be provided by the contractor.
M&L for surface dressing n.exc 15 cm deep and removing rubbish to distance n.exc 50m including cleaning of bushes/small plants up to root level, around and surrounding area of E/M installations (i.e two pole / four pole structures, out door substation yards & misc E/M installations) complete all as specified and as directed by Engr-in-charge.
M&L for disconnecting burnt LT cable from MCCB/Main switch/OH line etc and cleaning the bus bar and removing carbon and rusted nut bolts etc complete and reconnecting the LT cable after replacement of aluminium lugs, glands etc for LT under ground cable of size 16 sqmm 3.5 core complete all as specified and as directed.
All as per serial item No 34.00 but for LT under ground cables 25 sqmm 3.5 core
All as per serial item No 34.00 but for LT under ground cables 35 sqmm 3.5 core
All as per serial item No 34.00 but for LT under ground cables 50 sqmm 3.5 core
All as per serial item No 34.00 but for LT under ground cables 70 sqmm 3.5 core
All as per serial item No 34.00 but for LT under ground cables 95 sqmm 3.5 core
All as per serial item No 34.00 but for LT under ground cable 120 sqmm 3.5 core
All as per serial item No 34.00 but for LT under ground cable 150 sqmm 3.5 core
M&L in repairs to LT panel boards complete with necessary welding works to doors, replacement of unserviceable hinges and aldrop bolt complete and painting with one coat of synthetic enamel paint of approved colour internally and externally complete all as specified and as directed by Engr-in-charge.
M&L for replacement of damaged sheet of panel board of size not less than 0.6m x 0.75m made of 14 SWG MS powder coated sheet to match to existing including bending, cutting, pressing to required size and shape complete all as specified and as directed by Engr-in-charge.
M&L for MCCB TPN 63 amps capacity, breaking capacity 16 KA at 415 volt 50 Hz AC supply including necessary modification in panel board if required to fix the MCCB complete with replacement of incoming and out going cable connection with lugs, aluminium conductor cable of proper size, nuts bolts including taking out old unserviceable MCCB TPN from existing LT panel board complete all as specified and as directed by Engr-in-charge.
All as per serial item No 37.00 above but 100 amps capacity, breaking capacity 25 KA complete all as specified and as directed.
All as per serial item No 37.00 above but 160 amps capacity, breaking capacity 36 KA complete all as specified and as directed.
All as per serial item No 37.00 above but 400 amps capacity, breaking capacity 36 KA complete all as specified and as directed.
S&F in repairs 415V MCB TPN 100 Amps 10 KA 'C' complete with connection, testing and commissioning complete all as specified and as directed.
Supply, install, testing and commissioning in replacement, factory made and tested (including CPRI type test certified) LT feeder pillar box (KIOSK) out door type, floor mounted, compartmantalised and IP-54 suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, all as specified and directed, having bus bar chamber with insulated aluminium bus bars 250 amps rating installed on porcelain insulators. The panel shall be dust and vermin proof, made of 3.15mm CRCA MS sheet and with base frame of 50x50x6mm angle iron , powder coated, Front and rear opening type with aprons for cable entry with double door shutter and locking arrangement with including cable gland, lugs, jointing material etc and jointing, connecting, testing and commissioning and including following items. (Notes :The rate quoted shall include for Cost of dismantling/ taking down old unserviceable LT feeder piller, earth work & excavation for angle iron frame for foundation of panel board upto 0.50 m below GL in any type of soil & PCC (1:4:8), D2 filling in foundation the ground clearance of panel board shall be 0.40 m GL to the bottom of panel board ).
Supply, install, testing and commissioning in replacement, factory made and tested (including CPRI type test certified) LT feeder pillar box (KIOSK) out door type, floor mounted, compartmantalised and IP-54 suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, all as specified and directed, having bus bar chamber with insulated aluminium bus bars 150 amps rating installed on porcelain insulators. The panel shall be dust and vermin proof, made of 3.15mm CRCA MS sheet and with base frame of 50x50x6mm angle iron , powder coated, Front and rear opening type with aprons for cable entry with double door shutter and locking arrangement with including cable gland, lugs, jointing material etc and jointing, connecting, testing and commissioning and including following items. (Notes :The rate quoted shall include for Cost of dismantling/ taking down old unserviceable LT feeder piller, earth work & excavation for angle iron frame for foundation of panel board upto 0.50 m below GL in any type of soil & PCC (1:4:8), D2 filling in foundation the ground clearance of panel board shall be 0.40 m GL to the bottom of panel board ).
Supply, install, testing and commissioning in replacement, factory made and tested (including CPRI type test certified) LT feeder pillar box (KIOSK) out door type, floor mounted, compartmantalised and IP-54 suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, all as specified and directed, having bus bar chamber with insulated aluminium bus bars 300 amps rating installed on porcelain insulators. The panel shall be dust and vermin proof, made of 3.15mm CRCA MS sheet and with base frame of 50x50x6mm angle iron , powder coated, Front and rear opening type with aprons for cable entry with double door shutter and locking arrangement with including cable gland, lugs, jointing material etc and jointing, connecting, testing and commissioning and including following items. (Notes :The rate quoted shall include for Cost of dismantling/ taking down old unserviceable LT feeder piller, earth work & excavation for angle iron frame for foundation of panel board upto 0.50 m below GL in any type of soil & PCC (1:4:8), D2 filling in foundation the ground clearance of panel board shall be 0.40 m GL to the bottom of panel board ).
Material and labour for preparation of surfaces for LT pole painting by scrapping damaged paint and painting with two coats of silver aluminium paint and alternate painted strip of 30 cm width of colour as approved by Accepting officer upto 1.5 meter height from bottom of the pole and writing pole No with black paint on yellow circuit complete all as specified and as directed by Engineer-in-Charge.
M&L for disconnecting and taking down unserviceable street light fittings/gate lights & garden lights of any type/rating from pole or wall dismantling the same for necessary repair or replacment of unserviceable spares complete and refixing, connecting and testing the same complete all as specified and as directed. Notes:- (i) Spares/accessories required for replacement shall be measured and paid seprateley as supply only under respective items of BoQ. (ii) The cost of T&P required for repair/ mantenance such as ladder, vehicle like crane, manpower etc, shall deemed to be included in the unit rate quoted.
Supply only LED drivers compatible with industrial & outdoor LED fixtures/Sign boards as per existing make and model suitable for 30 Watt LED fitting complete all as specified and as directed.
All as per serial item No 44.00 but Suitable for 50 Watt LED fitting
All as per serial item No 44.00 but Suitable for 60 Watt LED fitting
All as per serial item No 44.00 but Suitable for 90 Watt LED fitting
All as per serial item No 44.00 but Suitable for 120 Watt LED fitting
All as per serial item No 44.00 but Suitable for 150 Watt LED fitting
S&F in replacement PVC insulated and over all PVC sheathed, stranded copper conductor wire 1.5 sqmm x 3 core, ISI marked complete from light fitting to pole junction box complete all as specified and as directed.
Supply and fixing GI pipe bracket light grade of 40mm dia ISI marked duly bent to shape with an angle including clamps, nuts, bolts, washers etc complete and taking out of existing old u/s brackets ofcomplete all as specified and directed by Engineer-in-Charge. (Note: - The total length of the bracket shall be 1.5m)
Supply and fixing GI pipe bracket light grade of 50mm dia ISI marked duly bent to shape with an angle including clamps, nuts, bolts, washers etc complete and dismantling of existing old u/s brackets of complete all as specified and directed by Engineer-in-Charge. (Note: - The total length of the bracket shall be 1.5m)
S&F 1100 volts grade heavy duty cable, 4 sqmm 2 core, PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections twin core cable flat stranded conductor including taking down old unserviceable cable complete all as specified and directed.
All as per serial item No 48.00 but 6 sqmm 2 core
All as per serial item No 48.00 but 10 sqmm 2 core
S&F in replacement PVC weather proof, hinged door, junction box with aluminium bus bar, 240V, neutral link and 1No MCB SP of 6 Amps, necessary fixing arrangement such as clamps, nut, bolts etc complete all as specified and as directed.
M&L for repair of Unserviceable street light timer controller panel including reconnecting and testing complete all as specified and directed. Note:- Spares/accessories required for replacement shall be measured and paid seperately under respective item of BoQ.
Supply only digital type timer single phase, 230 Volts, 50 Hz of rating 20 Amps complete all as specified and as directed.
Supply only contactor 2 pole 40 Amps main pole confugration 230 volts fixing with existing box by suitable size of copper cable with suitable size of lugs complete all as specified and as directed.
Supply only contactor 3 pole 40 Amps main pole confugration 415 volts fixing with existing box by suitable size of copper cable with suitable size of lugs complete all as specified and as directed.
Supply only 415V MCB TPN 63 Amps 10 KA 'C' complete with connection testing and commissioning complete all as specified and as directed.
M&L in repairs for lowering of high mast lantern carriage for disconnecting and taking down unserviceable high mast light fittings of any type/rating, dismantling the same for necessary repair or replacment of unserviceable spares and refixing, connecting, testing including raising high mast lantern carriage to its original position complete all as specified and as directed. Notes:- (i) Spares/accessories required for replacement shall be measured and paid seperately under respective item of BoQ. (b) Cost of T&P required for repair/ maintenance such as ladder, vehicle, manpower etc, shall deemed to be included in the unit rate quoted.
Supply only 200 watt LED flood light, energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP65 flood light with high power LEDs as light source, suitable for highlighting architectural facade highmast and general purpose lighting complete all as specified and as directed.
Supply only stainless steel wire rope of 6mm dia (7/19 construction) complete all as specified and as directed.
Supply only flexible copper cable 2.5 Sqmm 5 core complete all as specified and as directed.
Supply only starter suitable for 3.0 HP motor, three phase, 415 V , AC supply with forward/ reverse switch for High mast raising and lowering of lantern carriage with its supporting stand.
M&L for repairing of highmast light panels complete with necessary welding works to doors, replacement of unserviceable including wiring, fixing of timer, contactor & MCB etc complete all as specified and as directed. Notes:- (i) Spares/accessories required for replacement shall be measured and paid seperately under respective items of BoQ. (ii) Cost of T&P required for repair/ mantenance such as ladder, vehicl, manpower, welding cutting arrangement etc, shall deemed to be included in the unit rate quoted.
Supply and fix in replacement of 170 watt LED flood light, energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP65 flood light with high power LEDs as light source, suitable for highlighting architectural facade highmast and general purpose lighting.
Supply and fix in replacement 60 watt LED street light of new generation energy saving and environmental friendly long life, made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP opening seperate driver compartment with IP66 protection and impact resistance of IK07, suitable upto 40 mm mounting pipe as directed. Make: LUKER, Cat No. LST-60 or equivalent model of makes specified.
Supply and fix in replacement 90 watt LED street light of new generation energy saving and environmental friendly long life, made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP opening seperate driver compartment with IP66 protection and impact resistance of IK07, suitable upto 40 mm mounting pipe as directed by engineer-in-charge. Make: LUKER, Cat No. LST-90 or equivalent model of makes specified.
S&F in replacement of post top lantern light decorative type post top for 360 degree indirect light IP 65 protection resistant to impact and corrosion, Glare-free and better uniformity 20 watt LED 230 V 50 Hz including necessry fitting accessories complete all as per directed by engineer-in-charge.
Supply, install, testing and commissioning in replacement, factory made and tested (including CPRI type test certified) LT feeder pillar box (KIOSK) out door type, floor mounted, compartmantalised and IP-54 suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, all as specified and directed, having bus bar chamber with insulated aluminium bus bar 300 amps rating installed on porcelain insulators. The panel shall be dust and vermin proof, made of 3.15mm CRCA MS sheet and with base frame of 50x50x6mm angle iron , powder coated, Front and rear opening type with aprons for cable entry with double door shutter and locking arrangement with including cable gland, lugs, jointing material etc and jointing, connecting, testing and commissioning and including following items. (Notes :The rate quoted shall include for Cost of dismantling/ taking down old unserviceable LT feeder piller, earth work & excavation for angle iron frame for foundation of panel board upto 0.50 m below GL in any type of soil & PCC (1:4:8), D2 filling in foundation the ground clearance of panel board shall be 0.40 m GL to the bottom of panel board ).
S & F in repairs 10 Watt decorative type garden path lights bollard type Housing made up of aluminium pipe UV protected pure polyster powder coated with high efficiency long life LED module with SMD LED package and including necessary Concrete foundation fixed by 3 nos M 10 bolts complete as specified and as directed by Engr-in-Charge. Make: HAVELLS Cat No TURINBLS10WLED857PSYMTOPC or equivalent model of makes specified.
vedant engineering enterprises (BID ID -3444050)
M/s AG PATHAN (BID ID -3444323)
HG PATHAN CONSTRUCTION COMPANY (BID ID -3444011)
M/s. N D Karande (BID ID -3444252)
BHAVIN INFRA (BID ID -3443972)
KAMINS CARE (BID ID -3444100)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .