Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹4.3 LAccepted-AOC MANALUVILA THUNDIL KAITHACODE KOLLAM | KOLLAM | KOLLAM | KERALA | ₹4.3 L | 1 | Accepted-AOC Accepted in PQ Meeting |
| 2 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Others-1.Non-Submission of Bounden Agreement
2.Incomplete Technical Documents
3.Non-Receipt of Hard Copies |
Tender Value
₹5.1 L
EMD Value
₹13,000
Closing Date
26 Feb 2026, 11:00 amClosed
ASST. EXECUTIVE ENGINEER
220kV SUBSTATION SUBDIVISION KUNDARA
Providing Yard Fencing at 220kV Substation Kundara
2026_KSEB_828568_2
03/2025-26/SSDK/Fencing/Dtd 17.01.2026
Open Tender
Civil Works - Others
Percentage
60 days
220kV Substation Kundara
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,298
₹13,000
30 Mar 2026
11 Feb 2026
4 Mar 2026
11 Feb 2026
26 Feb 2026
12 Feb 2026
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Welding one end of the bended GI strip of size 50x6mm with the riser of the already laid earth mat, welding 150mm in length, 6mm thick on both sides & end of the strip and connecting other end with nuts & bolts if required as per the directions of the department officers. Charges includes hire charges of DC arc welding set, current charges, cost of low hydrogen content DC arc welding electrodes(No.E7018) cost of anti corrosive paint etc. complete.
Bending 32mm MS rod for crossing cable trench/foundations/risers etc.
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x15 cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 15cm in: CM 1:6 ( 1 cement :6 coarse sand) etc complete
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelMild steel and Medium Tensile steel bars
Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts , bolts and washers as required complete as per the direction of Engineer-in- charge.Made of G.I. wire of dia 4 mm
Laying of earth mat of required size as specified using 40/32/25mm MS rod including levelling lowering and placing in trenches, complete as per the direction of departmental officers.
Welding of overlapping joints for mat,riser lap joints with 32/25mm MS rod placed in trenches, having 150mm in length 6mm in thick on both sides of the rod and both ends of overlapped MS rods with 6mm welding thickness after cleaning the surfaces neatly. Charges includes cost of low hydrogen DC electrode (No. E7018), hire charges of DC arc welding set and tools and plants required, current charges including labour charges for holding MS rod in position and applying two coats of anti corrosive paints at the welded joints etc. complete as per the directions of department officers.
Cutting 32mm MS rod in required length etc complete as per the direction of the departmental officers.
Conveying, laying and spreading 6/40mm broken stone on the levelled surface of the yard at a uniform thickness of 10cm etc. Complete as per the direction of dept. Officers in charge
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.15 MB
TenderDocuments.pdf
Tender Documents • 0.22 MB
Drawing.pdf
Tender Documents • 0.46 MB
BOQ_1406429.xls
BOQ • 0.25 MB
CorrigendumR1.pdf
PDF • 0.20 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .