DESIGN, SUPPLY OF HARDWARE AND SOFTWARE, INSTALLATION, TESTING AND
2400014192-HD-09050
5100014192
Open Tender
Medchal Malkajgiri, Telangana
₹0
Exempted
31 Jul 2024
9 Jul 2024
31 Jul 2024
31 Jul 2024
11 Jul 2024 - 19 Jul 2024
16 Jul 2024
| Item No | Item Title | Description | Qty | Unit |
|---|---|---|---|---|
| 1 | SUP LRC SERVER | SUP LRC SERVER — pply of Redundant Load Rack Server with each set consisting of Supply of two nos. of Load Rack Server, rack based along with High a ilability redundancy software & working on redundant (Primary and Secondary) hot standby mode along with accessories like 1 No. Rack ounted 19" LED Monitor with Keyboard & mouse, 4 port industrial grade KVM switch, software like OS, Antivirus, SQL, oracle, RDBMS et (license copy) etc complete as per specification and Tender Documents.In addition, the LRC system shall be configured to have Zero D ntime to repair, Full data redundancy shall be provided using proven technology, it shall also provide port level redundancy. The sy em solution shall be capable of self fault detection and isolation, all necessary hardware/ software configuration to achieve the sa shall be included.Each Load Rack Server shall be supplied with Dual Processor having 3rd Generation Intel Xeon Scalable processors th minimum 12Cores/24Threads per Processor. | - | SET |
| 2 | ITC LRC SERVER | ITC LRC SERVER — stallation, testing and commissioning of Redundant Load Rack Server with each set consisting of Supply of two nos. of Load Rack Ser r, rack based along with High availability redundancy software & working on redundant (Primary and Secondary) hot standby mode along ith accessories like 1 No. Rack mounted 19" LED Monitor with Keyboard & mouse, 4 port industrial grade KVM switch, software like OS, ntivirus, SQL, oracle, RDBMS etc (license copy) etc complete as per specification and Tender Documents.In addition, the LRC system s ll be configured to have Zero Downtime to repair, Full data redundancy shall be provided using proven technology, it shall also prov e port level redundancy. The system solution shall be capable of self fault detection and isolation, all necessary hardware/ softwar configuration to achieve the same shall be included. | - | SET |
| 3 | "SUP RED.PROCESS PLC" | "SUP RED.PROCESS PLC" — pply of Dual redundant (Parallel/ Hot Standby) Programmable Logic Controller (Process PLC) along with PLC Panels, Marshalling Panels Input Output modules,Dual Power supply units, Relays with base, barriers, TBs, Dual Ethernet ports per processors, Serial Interface dules,HMI console, wirings, glands, plugs, other modules/hardware required for interfacing all the required field and control room E ipments including licenses, tags, GUI, software etc complete as per specification and tender document. | - | SET |
| 4 | "ITC RED.PROCESS PLC" | "ITC RED.PROCESS PLC" — stallation, testing and commissioning of Dual redundant (Parallel/ Hot Standby) Programmable Logic Controller (Process PLC) along wi PLC Panels, Marshalling Panels, Input Output modules,Dual Power supply units, Relays with base, barriers, TBs, Dual Ethernet ports r processors, Serial Interface Modules,HMI console, wirings, glands, plugs, other modules/hardware required for interfacing all the quired field and control room Equipments including licenses, tags, GUI, software etc complete as per specification and tender docume . | - | SET |
| 5 | SUP LCP PANEL | SUP LCP PANEL — upply of PLC based Flameproof & Weather Proof to IP 65 or better Local Control Panel for LPG Pump & Integration with Plant PLC & VFD anel on Open Protocol like Modbus / Ethernet etc.: Supply of PLC based Local Control Panel for use in hazardous area Zone 1 and all lame proof and Intrinsically safe equipment shall be suitable for Zone I,IIA / IIB and temperature Class T3 as per IEC norms with ST T/STOP/ACK/RESET Push button, ON/OFF switch, Local/ Remote Selector Switch, AI/DI/DO modules, relays, FLP Cable glands & PESO & CMRI pproved Plugs, LED Fuse terminals, 12 nos. Flameproof LED at panel with hooter for alarm annuciation as per I/O List for LPG Pump C trol panel complete along with accessories, required wirings & necessary hardware for Integration with Plant PLC & VFD on Open Proto l like Modbus / Ethernet etc. complete as per tender specifications and instructions of HPCL Engineer in charge.The Alarm Annuncia r will have following indications:1) Low Discharge Pressure due to Low Suction Pressure, 2)High Discharge Pressure, 3) Low Lube Oil evel, 4) Low Cooling Water Pressure, 5) Mech. seal leakage/failure, 8) Ready to Start,9)LPG Pump Tripped,10)Low Cooling Water Flow e following LED lamps shall be equipped on Panel:1) Control Power ON, 2) LPG PUMP OFF, 3) LPG PUMP ON, 4) LPG PUMP LOCAL/REMOTE IND ATION.Supply Includes Supply of all Accessories Like PESO & CMRI Certified Ni plated brass Double Compression Cable Glands with PV Shrouds and PESO & CMRI approved Plugs for excess entries, SS 316 engraved tag plate, mounting clamp and SS 316 fasteners complete a per specifications/tender documents. " | - | Each |
| 6 | ITC LCP PANEL | ITC LCP PANEL — nstallation, Testing & Commissioning of PLC based Flameproof & Weather Proof to IP 65 or better Local Control Panel for LPG Pump & tegration with Plant PLC & VFD on Open Protocol like Modbus / Ethernet etc. Scope shall also cover trenching, tray work, cable layin in trenches, civil work and on trays, glanding and ferruling, lugging, termination at both ends, loop checking, etc. all are include in scope. Scope also includes configuring & sharing register / address /mapping details & Communication Protocol required for data s ring for Integration with Plant PLC & VFD on Open Protocol like Modbus / Ethernet etc. | - | Each |
| 7 | SITC TAS software | SITC TAS software — upply, installation, testing and commissioning of Terminal Automation Software (with feature like auto UAN/ FAN generation etc.) for oad Rack Server and Operator Stations with dongle/key, licenses, media, documentation etc., complete as per specifications / tender cuments. TAS is the front end for all sub systems, hence below subsystems shall be interfaced with TAS for Monitoring, Logging, Repo ing and Controls-Interlocks etc.Scope along includes Supply, installation, testing and commissioning of SCADA software with 100% sp e tags along with dongle/key, licenses, media, documentation etc. complete as per specifications /documents. The TAS Software shal necessarily have features as below:1.Bulk & Packed Tank Truck Access Control System alongwith creation of database in Truck Master r Bulk and Packed TT along with its Crew.2.Implementation of user based profile menu that can be configured and managed with editab activity, menu & screen Permissions restrictions assignment so that entire TAS activity including enrollment of TT & its Crew can b carried from any OIC.3. Implementation of TAS Security Guideline as per attached Tender document.4. Integration of HPCL applicatio with TAS including SAP, VTS, IMS, OLA,Driver/Transporter Portal as required for Auto Indent & Invoice generation for Bulk Road Tank nker loading & sub systems covered in the work.5.TFMS Integration with SAP for new & Existing MSV as required for Inventory Manage nt6. SCADA for New Terminal Automation System as well as Existing ROVs & MOVs Operation shall be designed with dynamic linking for I as per direction of HPCL EIC7. Installation of Anti Virus for TAS System.8. Integration of Existing ROV & MOV PLC Based Control nel Soft Tags with TAS SCADA.9. Development of Logic,GUI & reports formats for LPG Pump & VFD Operation, New & Existing POVs & ROVs peration, Local field Control Panels for LPG Pump,Boom Barrier Operations,Loading Operation of Bays, Entry to Exit System & all othe Facilities as required for Successful Site Acceptance Test for TAS as per Direction of HPCL EIC & FDS finalised between TAS Vendor & PCL including compliance points for SAT also.Note: TAS / SCADA Software shall be developed as per the directional FDS, interlocks trip-diagrams, Security Features as specified in tender document and specifications attached with the tender. However there may be s stantial modifications to the user requirements including but not limited to changes in interface philosophy, changes in signals exc nge protocols, addition/ changes in additional features to be added in the software, addition / changes in the report formats etc. A such requirements which may keep arising till the successful completion of SAT shall be met by the successful bidder and logic modi ed accordingly. Please note that no extra price shall be given on account of these changes which may keep happening till the point o SAT as per user requirement.System Interfaces: (Based on functional requirement for interfacing of the available sub systems at the cations)- VA Interface- Barrier Gates, weigh bridge and ACS Interface-Power distribution boards System stated below with TAS & s commissioning with SPAS for Alarms, archiving & events logging - 3 rd party Video Analytic- 3 rd party Central Command Center D h Board- 3 rd party Visitor management System , Access Control System- 3rd party Weigh bridge etc" | - | Lump Sum |
| 8 | SUP FLP & WP FCP 1 | SUP FLP & WP FCP 1 — upply of Flameproof & Weather Proof to IP 65 or better Relay Based duly wired Field Control Panel suitable for Zone I, IIA / IIB and emperature Class T3 as per IS/IEC norms for MSV & TT GANTRY ROVs & EXISTING MSV POVs suitable for open / close operation of 4 nos. Vs / POVs per Cluster/ Field Control Panel alongwith local indications and provision for repeat indication for ON/OFF feedback of in vidual Valves at Monitoring Room PLC complete as per Wiring & Instrument Scheme,specification and tender document. Cable Entry sha be Bottom and cable entry shall be as per cable dia according to Cable schedule." | - | Each |
| 9 | ITC FLP & WP FCP 1 | ITC FLP & WP FCP 1 — nstallation, Testing & Commissioning of Flameproof & Weather Proof to IP 65 or better Relay Based duly wired Field Control Panel sui ble for Zone I, IIA / IIB and temperature Class T3 as per IS/IEC norms for MSV & TT GANTRY ROVs & EXISTING MSV POVs suitable for op / close operation of 4 nos. ROVs / POVs per Cluster/ Field Control Panel alongwith local indications and provision for repeat indic ion for ON/OFF feedback of individual Valves at Monitoring Room PLC complete as per Wiring & Instrument Scheme,specification and ten r document. Cable Entry shall be Bottom and cable entry shall be as per cable dia according to Cable schedule." | - | Each |
| 10 | SUP FLP & WP FCP 2 | SUP FLP & WP FCP 2 — upply of Flameproof & Weather Proof to IP 65 or better Relay Based duly wired Field Control Panel suitable for Zone I, IIA / IIB and emperature Class T3 as per IS/IEC norms for NEW MSV POVs suitable for open / close operation of 10 nos. POVs per Cluster/ Field Cont l Panel alongwith local indications and provision for repeat indication for ON/OFF feedback of individual Valves at Monitoring Room C complete as per Wiring & Instrument Scheme,specification and tender document. Cable Entry shall be Bottom and cable entry shall as per cable dia according to Cable schedule." | - | Each |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.