Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.0 CrAdmitted-Finance | ₹1.0 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.2 CrAdmitted-Finance PLOT NO 29 30 JAHNAVI INDUSTRIAL LAYOUT HANCHIPURA VILLAGE NELAMANGALA TALUK BENGALURU BANGALORE RURAL KARNATAKA 562123 UDYAM KR 03 0004508 | BENGALURU RURAL | KARNATAKA | 562123 | ₹1.2 Cr | L2 | Admitted-Finance |
| 3 | Rejected-Technical PLOT NO 13 SHAKTI KHAND II INDRAPURAM GHAZIABAD 201014 | GHAZIABAD | UTTAR PRADESH | 201014 | - | - | Rejected-Technical Not complied prequalification criteria |
| 4 | Rejected-Technical D NO LIG 98 RAJEEV NAGAR KURMANNAPALEM VISAKHAPATNAM 530 048 | VISAKHAPATANAM | ANDHRA PRADESH | 530048 | - | - | Rejected-Technical Not complied prequalification criteria |
| 5 | Rejected-Technical | - | - | Rejected-Technical Not complied prequalification criteria |
| Sl No | Description | Qty | Unit | ROMAS ELECTRIC PRIVATE LIMITED L2 | QUALITY ENGINEERING SERVICES L1 |
|---|---|---|---|---|---|
| 1.01 | Supply, installation, testing & commissioning of 5- Way RMU,11 KV on the existing plinth with rated voltage 12KV, 630A, 21KA-3sec, Outdoor type, extensible type on both sides, Internal arc 21KA for 1 Sec for Tank, floor mounted with internal copper bus bars, SF6 Insulated, completely Motorised, with modems and with SCADA compatible Overload and earth fault protection Relay The unit shall have front cable entry (Suitable for termination of 1R x 3C x 95/120/185 Sq.mm Cable. As per the following switch gears and Technical Specifications enclosed Annexure –I. Make: Siemens, ABB, Schneider Electric, and Eaton, 3rd party inspection :- IRS, LLYODS, RITES, PDIL, EIL, MECON or any other authorized organization as approved by VPA | 1 | No | 17,12,500 ₹17,12,500 Lowest | 18,10,000 ₹18,10,000 |
| 1.02 | Supply, installation, testing & commissioning of 3- Way RMU,11 KV on the existing plinth with rated voltage 12KV, 630A, 21KA-3sec, Outdoor type, extensible type on both sides, Internal arc 21KA for 1 Sec for Tank, floor mounted with internal copper bus bars, SF6 Insulated, completely Motorised, with modems and with SCADA compatible Overload and earth fault protection Relay The unit shall have front cable entry (Suitable for termination of 1R x 3C x 95/120/185 Sq.mm Cable. As per the following switch gears and Technical Specifications enclosed Annexure-I. Make: Siemens, ABB, Schneider Electric, and Eaton, 3rd party inspection :- IRS, LLYODS, RITES, PDIL, EIL, MECON or any other authorized organization as approved by VPA 3rd party inspection :- IRS, LLYODS, RITES, PDIL, EIL, MECON or any other authorized organization as approved by VPA | 1 | No | 13,51,250 ₹13,51,250 | 12,40,000 ₹12,40,000 Lowest |
| 1.03 | Supply of 3C x 95 Sq. mm XLPE insulated IS: 7098 / II / 85 H.T. cable for working voltage 11 K.V Earthed with Stranded Compacted Circular Aluminium Conductor Screened with Extruded Semi-conducting compound, XLPE Insulated in combination with Copper Tape, cores laid up, inner sheath of Thermoplastic tape, galvanised flat steel strip armoured and overall Extruded PVC Type ST- 2 Outer Sheathed cable etc. complete with all material, tools and tackles as directed by Engineer-In-Charge as per Annexure II Make: KEI / Polycab / Gloster / RR Kabel / RPG / Finolex / Havells | 1,200 | Mtrs | 1,223 ₹14,67,600 Lowest | 1,280 ₹15,36,000 |
| 1.04 | Supply and transportation of 1.1 KV grade following LT Cable XLPE insulated, armoured aluminium cable, PVC overall sheathed multi stranded aluminium conductor Cable conforming to IS 7098 / Part-I /1554-1 complete with all material, tools and tackles as directed by Engineer-In-Charge.Brands: Finolex / Gloster / RPG / Havells / Polycab / KEI / RR Kable / 3.5 C X 120 Sq.mm | 800 | Mtrs | 944 ₹7,55,200 Lowest | 1,000 ₹8,00,000 |
| 1.05 | 3.5 C X 50 sq.mm. | 1,000 | Mtrs | 485 ₹4,85,000 | 430 ₹4,30,000 Lowest |
| 1.06 | 3.5 C X 25 sq.mm | 500 | Mtrs | 345 ₹1,72,500 | 250 ₹1,25,000 Lowest |
| 1.07 | Laying / clamping / drawing of the HT / LT cables in existing trench / to wall / pole / through existing HDPE pipe including and brick protection with all materials tools and tackles as directed by Engineer –in-charge. Note: Cable will be supplied by VPA at free of cost. | 3,500 | Mtrs | 90 ₹3,15,000 | 80 ₹2,80,000 Lowest |
| 1.08 | Excavation of trenches in Hard / dense soil of required width for laying of HDPE / GI pipes, cables and retrieving the existing cables etc., including dressing of sides, ramming of bottoms, measurement 1.5m depthx0.5m width required length (as per sight requirement) including getting out the excavated soil and the returning the soil including consolidating each deposit layer by ramming, watering etc., and disposing of surplus excavated soil as directed by engineer in charge and complete all labour and material. | 900 | M3 | 310 ₹2,79,000 | 250 ₹2,25,000 Lowest |
| 1.09 | Supply, laying / Clamping of 110 mm diameter PE-100 grade HDPE pipe to the pole with existing clamps / in existing trench as directed by Engineer-in-Charge complete with all labour tools, tackles and materials.MAKES: KSP/ SUDHAKAR / NANDI. | 1,800 | Mtrs | 400 ₹7,20,000 | 270 ₹4,86,000 Lowest |
| 1.10 | Supply and providing of CI earth station using 80mm diameter flanged CI pipe of length 2.5 Mtrs duly perforated and with suitable PCC covering as per IS 3043 in a pit of suitable depth filled with alternate layers of salt and charcoal as directed by engineering in-charge including all labour and material. | 12 | Nos. | 5,000 ₹60,000 Lowest | 6,000 ₹72,000 |
Tender Value
₹1.0 Cr
EMD Value
₹2.0 L
Closing Date
4 May 2026, 12:00 pmClosed
CME
AOB 2ND FLOOR CME CHAMBER
NHAI PIU Visakhapatnam Development of adequate road connectivity of 4 6 lane from Vizag Port Connectivity from Sheelanagar Junction to Convent Junction Hindrances in Ramp B alignment Shifting and diversion of existing 11KV HT and LT network
2026_VPT_273815_1
150/26-27/IMEE/ELE/EMP/1393, Dt.06.04.2026
Open Tender
Electrical Works
Works
120 days
VPA
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,770
Yes
₹2.0 L
Yes
8 Jun 2026
6 Apr 2026
5 May 2026
6 Apr 2026
4 May 2026
6 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.01 | Supply, installation, testing & commissioning of 5- Way RMU,11 KV on the existing plinth with rated voltage 12KV, 630A, 21KA-3sec, Outdoor type, extensible type on both sides, Internal arc 21KA for 1 Sec for Tank, floor mounted with internal copper bus bars, SF6 Insulated, completely Motorised, with modems and with SCADA compatible Overload and earth fault protection Relay The unit shall have front cable entry (Suitable for termination of 1R x 3C x 95/120/185 Sq.mm Cable. As per the following switch gears and Technical Specifications enclosed Annexure –I. Make: Siemens, ABB, Schneider Electric, and Eaton, 3rd party inspection :- IRS, LLYODS, RITES, PDIL, EIL, MECON or any other authorized organization as approved by VPA | 1 | No | - | - |
| 1.02 | Supply, installation, testing & commissioning of 3- Way RMU,11 KV on the existing plinth with rated voltage 12KV, 630A, 21KA-3sec, Outdoor type, extensible type on both sides, Internal arc 21KA for 1 Sec for Tank, floor mounted with internal copper bus bars, SF6 Insulated, completely Motorised, with modems and with SCADA compatible Overload and earth fault protection Relay The unit shall have front cable entry (Suitable for termination of 1R x 3C x 95/120/185 Sq.mm Cable. As per the following switch gears and Technical Specifications enclosed Annexure-I. Make: Siemens, ABB, Schneider Electric, and Eaton, 3rd party inspection :- IRS, LLYODS, RITES, PDIL, EIL, MECON or any other authorized organization as approved by VPA 3rd party inspection :- IRS, LLYODS, RITES, PDIL, EIL, MECON or any other authorized organization as approved by VPA | 1 | No | - | - |
| 1.03 | Supply of 3C x 95 Sq. mm XLPE insulated IS: 7098 / II / 85 H.T. cable for working voltage 11 K.V Earthed with Stranded Compacted Circular Aluminium Conductor Screened with Extruded Semi-conducting compound, XLPE Insulated in combination with Copper Tape, cores laid up, inner sheath of Thermoplastic tape, galvanised flat steel strip armoured and overall Extruded PVC Type ST- 2 Outer Sheathed cable etc. complete with all material, tools and tackles as directed by Engineer-In-Charge as per Annexure II Make: KEI / Polycab / Gloster / RR Kabel / RPG / Finolex / Havells | 1,200 | Mtrs | - | - |
| 1.04 | Supply and transportation of 1.1 KV grade following LT Cable XLPE insulated, armoured aluminium cable, PVC overall sheathed multi stranded aluminium conductor Cable conforming to IS 7098 / Part-I /1554-1 complete with all material, tools and tackles as directed by Engineer-In-Charge.Brands: Finolex / Gloster / RPG / Havells / Polycab / KEI / RR Kable / 3.5 C X 120 Sq.mm | 800 | Mtrs | - | - |
| 1.05 | 3.5 C X 50 sq.mm. | 1,000 | Mtrs | - | - |
| 1.06 | 3.5 C X 25 sq.mm | 500 | Mtrs | - | - |
| 1.07 | Laying / clamping / drawing of the HT / LT cables in existing trench / to wall / pole / through existing HDPE pipe including and brick protection with all materials tools and tackles as directed by Engineer –in-charge. Note: Cable will be supplied by VPA at free of cost. | 3,500 | Mtrs | - | - |
| 1.08 | Excavation of trenches in Hard / dense soil of required width for laying of HDPE / GI pipes, cables and retrieving the existing cables etc., including dressing of sides, ramming of bottoms, measurement 1.5m depthx0.5m width required length (as per sight requirement) including getting out the excavated soil and the returning the soil including consolidating each deposit layer by ramming, watering etc., and disposing of surplus excavated soil as directed by engineer in charge and complete all labour and material. | 900 | M3 | - | - |
| 1.09 | Supply, laying / Clamping of 110 mm diameter PE-100 grade HDPE pipe to the pole with existing clamps / in existing trench as directed by Engineer-in-Charge complete with all labour tools, tackles and materials.MAKES: KSP/ SUDHAKAR / NANDI. | 1,800 | Mtrs | - | - |
| 1.1 | Supply and providing of CI earth station using 80mm diameter flanged CI pipe of length 2.5 Mtrs duly perforated and with suitable PCC covering as per IS 3043 in a pit of suitable depth filled with alternate layers of salt and charcoal as directed by engineering in-charge including all labour and material. | 12 | Nos. | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.78 MB
BOQ_319665.xls
BOQ • 0.31 MB
CORRIGENDUM.pdf
PDF • 3.05 MB
CORRIGENDUM.pdf
PDF • 0.53 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].