Tender Value
₹23.9 L
EMD Value
₹47,760
Closing Date
18 May 2023, 6:00 pmClosed
Y K Gour
HQ CWE Ranchi, MES Dipatoli Cantt
SPECIAL REPAIR /REPLACEMENT OF BER TRANSFORMER AND ALLIED WORKS AT RAMGARH CANTT UNDER GE RAMGARH
2023_MES_590466_1
80599/1457/E8
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
GE Ramgarh
Please refer Tender Documents
5 documents required · 5 mandatory
₹500
Yes
GE Ramgarh
₹47,760
Yes
HQ CWE Ranchi, MES Dipatoli Cantt
28 Jun 2023
20 Apr 2023
23 May 2023
20 Apr 2023
18 May 2023
4 May 2023
20 Apr 2023 - 27 Apr 2023
27 Apr 2023
Amount
Supply, installation, testing and commissioning outdoor type, pole mounted/plinth mounted stepdown transformer, 11 KV/415 volts (at full load) AC 3 phase 50 HZ,63 KVA capacity, core type, double copper wound, Oil immersed, oil Natural Air Natural (ON AN) with external cooling tubes, delta connected on primary side (HV) and star connected on secondary side (LV) in accordance with vector group DYN-11 with neutral brought out on secondary side (LV side) and having taping at ±2.5% & ±5% on HV side to be charged by means of hands operated off load tap changer gear. The maximum temperature rise should not exceed 45 degree celsius in oil and 55 degree celsius in HV/LV winding when measurement by resistance method after continous full load run on an ambient temp of 40 degree celsius. The transformer shall be IS-1180 marked with the following components :- (a) Three nos porcelain bushing suitable for 11 KV on HV side, complete with copper rods nuts and washers. (b) One cable box on LT side (Secondary side) consisting of four nos porcelain bushing with copper rods, complete with nuts and washers with cable glands suitable for reception/ taking out cable on LT side suitable for 1100 Volts grade, PVC/ XLPE insulated and PVC sheathed heavy duty armourd cable including jointing material complete. (c) De-hydration breather with first fill of dehydrating agent (silica gel) (d) Explosive vent, Thermometer pocket on tank cover, oil level gauge, Oil drain filter valve, lifting lugs, oil filling hole with cap/ plug with connection plate complete, air release valve plug and four nos plain solid cast steel detachable rollers.(e) One No. 100 mm dia dial type thermometer, vapour pressure type, having range 0-120 degree celsius with metal guard having maximum perimeter temperature reading indicator with re-setting device. (f) Two earthing terminals on tank cover to facilitate fixing of 32 X 6 mm galvanised iron earth strip for earthing of body. (g) Rating plate and terminal marking plate. (h) Extra bushing for neutral in the LT cable box for providing independent set of earthing for neutral. (j) First fill of new and unused transformer oil, IS-335 filtered and testing upto 40 KV dielectric strength at 2.5 mm air gap between testing electrodes. (k) Providing adequate size and nos of channel embedded in floor for movement of transformer.
Supply, installation, testing and commissioning outdoor type, pole mounted/plinth mounted stepdown transformer, 11 KV/415 volts (at full load) AC 3 phase 50 HZ, 200 KVA capacity, core type, double copper wound, Oil immersed, oil Natural Air Natural (ON AN) with external cooling tubes, delta connected on primary side (HV) and star connected on secondary side (LV) in accordance with vector group DYN-11 with neutral brought out on secondary side (LV side) and having taping at ±2.5% & ±5% on HV side to be charged by means of hands operated off load tap changer gear. The maximum temperature rise should not exceed 45 degree celsius in oil and 55 degree celsius in HV/LV winding when measurement by resistance method after continous full load run on an ambient temp of 40 degree celsius. The transformer shall be IS-1180 marked with the following components :- (a) Three nos porcelain bushing suitable for 11 KV on HV side, complete with copper rods nuts and washers. (b) One cable box on LT side (Secondary side) consisting of four nos porcelain bushing with copper rods, complete with nuts and washers with cable glands suitable for reception/ taking out cable on LT side suitable for 1100 Volts grade, PVC/ XLPE insulated and PVC sheathed heavy duty armourd cable including jointing material complete. (c) De-hydration breather with first fill of dehydrating agent (silica gel) (d) Explosive vent, Thermometer pocket on tank cover, oil level gauge, Oil drain filter valve, lifting lugs, oil filling hole with cap/ plug with connection plate complete, air release valve plug and four nos plain solid cast steel detachable rollers. (e) One No. 100 mm dia dial type thermometer, vapour pressure type, having range 0-120 degree celsius with metal guard having maximum perimeter temperature reading indicator with re-setting device. (f) Two earthing terminals on tank cover to facilitate fixing of 32 X 6 mm galvanised iron earth strip for earthing of body. (gf) Rating plate and terminal marking plate. (h) Extra bushing for neutral in the LT cable box for providing independent set of earthing for neutral. (j) First fill of new and unused transformer oil, IS-335 filtered and testing upto 40 KV dielectric strength at 2.5 mm air gap between testing electrodes. (k) Providing adequate size and nos of channel embedded in floor for movement of transformer.
Supply, installation, testing and commissioning outdoor type, pole mounted/plinth mounted stepdown transformer, 11 KV/415 volts (at full load) AC 3 phase 50 HZ, 250 KVA capacity, core type, double copper wound, Oil immersed, oil Natural Air Natural (ON AN) with external cooling tubes, delta connected on primary side (HV) and star connected on secondary side (LV) in accordance with vector group DYN-11 with neutral brought out on secondary side (LV side) and having taping at ±2.5% & ±5% on HV side to be charged by means of hands operated off load tap changer gear. The maximum temperature rise should not exceed 45 degree celsius in oil and 55 degree celsius in HV/LV winding when measurement by resistance method after continous full load run on an ambient temp of 40 degree celsius. The transformer shall be IS-1180 marked with the following components :- (a) Three nos porcelain bushing suitable for 11 KV on HV side, complete with copper rods nuts and washers. (b) One cable box on LT side (Secondary side) consisting of four nos porcelain bushing with copper rods, complete with nuts and washers with cable glands suitable for reception/ taking out cable on LT side suitable for 1100 Volts grade, PVC/ XLPE insulated and PVC sheathed heavy duty armourd cable including jointing material complete. (c) De-hydration breather with first fill of dehydrating agent (silica gel) (d) Explosive vent, Thermometer pocket on tank cover, oil level gauge, Oil drain filter valve, lifting lugs, oil filling hole with cap/ plug with connection plate complete, air release valve plug and four nos plain solid cast steel detachable rollers. (e) One No. 100 mm dia dial type thermometer, vapour pressure type, having range 0-120 degree celsius with metal guard having maximum perimeter temperature reading indicator with re-setting device. (f) Two earthing terminals on tank cover to facilitate fixing of 32 X 6 mm galvanised iron earth strip for earthing of body. (g) Rating plate and terminal marking plate. (h) Extra bushing for neutral in the LT cable box for providing independent set of earthing for neutral. (j) First fill of new and unused transformer oil, IS-335 filtered and testing upto 40 KV dielectric strength at 2.5 mm air gap between testing electrodes. (k) Providing adequate size and nos of channel embedded in floor for movement of transformer.
Supply and laying of HT UG cable XLPE insulated armoured heavy duty electric cable with stranded aluminium conductor 11000 volts grade cross section area 95 Sqmm 3 core laid in trenches or fixing on panels/ walls/poles or passing through pipe including connecting with suitable lugs, glands, nuts and bolts testing and including taking down complete all as specified and directed.
Earthing complete with galvanised steel earth plate electrode of size 60cms x 60cms x 6.0 mm thick as per IS 3043 of 1987 buried directly in to the ground (earthpit not less than 2.25 m deep below the ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to the galvanised earth lead by means of bolts , nuts check nuts and washers of galnanised iron or steel using GI strip 32 x 6 mm as earthing lead as shown in electric plate No-3 of SSR- Part-1 connected to earth strip all as specifed or indicated including testing on completion and necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC 1 :3:6 type C-1 using 20 mm graded stone aggregate, pit, funnel, 15 mm diia meduim grade watering pipe, 40 mm dia GI light grade earth lead protection pipe, CI frame and cover , wire copper lugs etc mesh, charcoal and common salt in alternate layer including taking down of old complete all as specified and directed by Engineer In Charge.
Material and labour for laying 80mm dia GI Tubing light grade for cable potection pipe including taking down complete all as specified and directed.
M/S Akash Enterprises
M/s Raj Aryan Construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .