| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.5 LAccepted-AOC SANYAL PARA ROAD HARANAVI KOLKATA 700 148 | KOLKATA | 24 PARAGANAS SOUTH | WEST BENGAL | 700148 | ₹6.5 L | L1 | Accepted-AOC L1 |
| 2 | L2₹7.5 LRejected-Finance | ₹7.5 L | L2 | Rejected-Finance L2 |
| 3 | L3₹8.0 LRejected-Finance 112 JAGAT BERH SRIPALLY 713103 PURBA BARDHAMAN WEST BENGAL | BARDHAMAN | PURBA BARDHAMAN | WEST BENGAL | 713103 | ₹8.0 L | L3 | Rejected-Finance L3 |
Tender Value
Refer Docs
EMD Value
₹19,483
Closing Date
19 Dec 2025, 12:00 pmClosed
Room No. 108, Purta Bhawan, Salt Lake
Room No. 108, Purta Bhawan, Salt Lake
AMC of Electrical Installation of whole system at Bijan Bhawan, Salt Lake -- Repair and rectification of existing dist. System and replacement of different type fittings, fixture and servicing of DG set and allied E.I work----- as and when required
2025_WBPWD_956083_1
WBPWD/EE/BED/e-NIQ-101/2025-26
Open Tender
ELECTRICAL WORKS ORG
60 days
Bijan Bhawan
Please refer Tender documents.
5 documents required · 5 mandatory
₹19,483
14 Jan 2026
21 Nov 2025
22 Dec 2025
28 Nov 2025
19 Dec 2025
28 Nov 2025
Amount
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required 3 x 22/0.3 (1.5 sqmm)
2x(2.5 sqmm) + 1x(1.5 sqmm)
2x(4 sqmm) + 1x(2.5 sqmm)
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required (Make: Polycab/KEI/Finolex/Havells) 3 x 22/0.3 (1.5 sqmm)
2x(2.5 sqmm)+1x(1.5 sqmm)
2x(4 sqmm) + 1x(2.5 sqmm)
Cutting Channel of size (40 mm x 40 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 19/25 mm, 3 mm thick Polythene pipe as per GS. 19 mm dia 3 mm thick
Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate and 2 no. suitable size “Ph & N” copper bar & earthing attachment fixed on wall incl. mending good damages to original finish. Average run 8 mtr
S & F 14W Inverter type LED BC type Lamp in existing Light Point (Make: Philips)
Fixing only outdoor / street light type fluorescent light fitting or MV light fitting complete with all accessories to be fixed /projected from the wall of the building incl. making holes/providing clamping arrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc.
S & Fixing of 240V, 90W LED Street light fittings at 40 mm GI pipe in different area as required.
S & F 240V 21A OLP - 3+ Electrronic motor starter with inbuilt digital display unit after dismantling of damaged / old one incl. Necy. Conncetion as required (Make: Electron)
S & F 10W, LED Bollard Light (Crompton: Model - LIARA, LBLSN-10-CDL / Philips ) after dismantling of old one.
Supply and Installation of 230 Volt 10 Ltr. Capacity Water Heaters (Geyser) with overload detection facility with necy. Inter connection with water / plumbing line with necy. Heat proof flex outlet fixing on wall by necy. Supporting arrangement. (Make - V Guard / Venus Splash Pro / AO Smith / Recold)
Supply and Installation of 230 Volt 15 Ltr. Capacity Water Heaters with overload detection facility with necy. Inter connection with water / plumbing line with necy. .Heat proof flex out let fixing on wall by necy. Supporting arrangement. ( Make - V Guard / Venus Splash Pro / AO Smith / Recold)
Supply and fixing modular switch board in/ on wall complete with top cover plate, 3 nos cu bar etc. as per GS as below. a) 2 Module
Supplying & Fixing GI Modular Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works. 4 Module
6 Module
8 Module
12 Module
2 Row 18 Module
Supply & Replacing 240 V 6 A Modular type switch (Legrand Myrius, Model: 673000) on existing GI Modular type switch board having top cover plate and making necessary connections as required
Supply & Replacing 240 V 20 A Modular type switch (Legrand Myrius, Model: 6730 11 / Brand approved by EIC) on GI Modular type switch board having top cover plate and making necessary connections as required
Supply & Fixing 240 V, 6A, 5 pin Modular type plug socket (Legrand Myrius, Model: 6730 44 / Brand approved by EIC), without switch & plug top, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Legrand Myrius, Model: 6730 47 / Brand approved by EIC), without plug top and switch, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Legrand Myrius, Model: 6730 28 / Brand approved by EIC) on existing Modular GI switch board with top cover plate incl. making necy. connections etc.
Supply & Fixing 240V, Modular Switch (1 Module) type fan regulator (Rotary Dimmer type) (Legrand Myrius, Model: 6730 28 / Brand approved by EIC) on existing Modular GI switch board with top cover plate incl. making necy. connections etc.
Supply and Fixing Single Blank Plate [ Make - Legrand Myrius Model / Cat No:- 679276/ Equivalent ].
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. 2.5sqmm
S & Replacing of 18W, Square / Round type, LED, WW / NW, Surface Mounted downlight (Philips /Crompton /Orient /Havells /Equivalent) as per direction of EIC
Supply & Replacing of 350 mm long, 7-Watt LED Aluminium body Mirror /Picture Light (White,) [Make: Philips - 30973 / Equivalent] as per direction of EIC
S & Replacing of 2watt LED foot light fittings (Make- Legrand, Skirting light with white LED - 3 module / Philips / equivalent) as per direction of EIC.
Supply of E27 base Dual bedside wall light combine with flexible LED reading light with 5W dimmable lamp set(Make:Fos Lighting/ Equivalent) as per direction of EIC
S & Replacing of 5 Mtr Long, 28W, WW/CDL/NW, Low glare LED Strip Light with Driver [Phillips - Linea Premium / Bright/Glow/ Blue /ColorMagic 3 in 1/ Equivalent ] as per direction of EIC
S & F of Silver / White, IP44, 7 Watt LED Wall Washer Lights [Make: Philips, Jojoba silver LED Wall light (Code:34034) / Equivalent] as per direction of EIC.
S & F of 220-240V, 4ft long, 20-watt, 3 in 1 Multicolour (CDL / WW / NW) LED Compact Tubelight set [ Make: Philips / Equivalent ] as per direction of EIC.
S & F of 24W, Square / Round type, LED, WW, Surface Mounted downlight (Philips / Crompton / Orient / Havells / Equivalent) as per direction of EIC.
S & F of 220V, 400 mm wall Bracket Fan [Make - EPC /Usha/ Orient - wall 41]
S & Replacing of GI sheet (20SWG) metal Cowl with MS flat iron frame & GI wire mesh on wall with necy. bolts & nuts (6 mm dia x 62 mm long) (12")
S & F of Exhaust fans complete with all accessories having the following Model ( Make -EPC ) 9"( 225mm )
S & F of Double pole, 240 V, AC Type, Sensitivity 100 mA, 25A RCCB & necy. Connections after replacement of old one [Make: Legrand - 4024 92 / Equivalent] as per direction of EIC.
Supplying and fixing 240/415 V, 63A FP MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection
S & F of 240V, 25A / 32A DP MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection after replacing of Isolator as per direction of EIC.
S&F of 240V, 10A /16A /20A SPMCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection after replacing of old MCB as per direction of EIC.
S & Replacing of ceiling fans complete with all accessories having the following Model / Cat No. ( Make - Orient - New Breeze (White) / Havells / Crompton/ equivalent ) 36'' (900 mm ) Sweep as per direction of EIC.
S & Replacing of 400V, 4P, 70A, Microcontroller Based Auto Changeover Switch at Main L.T Panel as per direction of EIC (Make: Electron - M70F / Equivalent).
S & Laying of 1000V, PVC insulated (Unsheathed) Single Core Multi Strand Annealed FR-LSH Copper Conductor (at Panels / DB) as per direction of EIC. 16.0 Sqmm
Supplying and fixing 63A, 415V, FP Changeover switch with Sheet Steel enclosure on angle iron frame on wall with nuts bolts etc (Make: HPL / Havells / Standard / As per direction of EIC)
Supplying and fixing 100A, 415V, FP Changeover switch with Sheet Steel enclosure on angle iron frame on wall with nuts bolts etc
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required. a) 4x126/0.4 (16 sqmm) + 2x80/0.4 (10 sqmm) as ECC
Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works a) 20mm size
Finishing of the PVC insulated wire ends by socketting with pin / ring type copper sockets and insulated tapes etc., including supplying sockets, tapes 10 sqmm
Removal of upto 4 core x 35 sqmm Al. Ar. Cable from existing TPN DB & terminate it to the FP changeover as per direction of EIC.
Supply & Laying of 4 Core XLPE 35 Sq. mm Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make: Havells/ Polycab/ Gloster/ RR Kabel/ KEI/ Mescab]
Supply & Laying of 4 Core XLPE 25 Sq. mm Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make: Havells/ Polycab/ Gloster/ RR Kabel/ KEI/ Mescab]
Supply of fuel of 250 KVA Jakson Make D.G. Set including Carring Charges
S & R of valvoline premium blue 7800 plus ( Lube oil)
S & R of Seperator between Fuel & water (part no. - 4093731 / Equivalent).
S & R of Air filter primary (part no. - 4315239 / Equivalent).
S & R of air - filter safety (part no. - 4315238 / Equivalent).
S & R of Gasket kit for fittings of diesel injector set and Head gasket kit set.
S & Replacement RADIWASH (Part no. AX7013507 / Equivalent).
S & F Copper oil pressure ring
S & F Benjo bolts for fuel pipe
Supply of Decorative Wall light, gold finish fixture with white glass diffuser with 1 N x E27 Base LED filament lamp. [Havells: GOBLETO WL 1LS E27 GLD, Model - LHFOAKD1TZ1D060 / Equivalent] as per direction of EIC.
S & D Electrical / Electronic Device Cleaner Spray for stain removers as per direction of EIC. Note:- i) Suitable quantity of Common / Regular EI materials like wires, Pipes, piano key type & modular type switches, sockets, MCB of different ratings, modular type switch boards, light fittings, DG spare parts etc. should be stored at site by the Agency in advance with his own responsibility to overcome emergency situations. ii) Works through requisition (i.e, Regular work) should be started within 16 hrs & the emergency breakdown works should be started within 4 hrs with requisite manpower after getting the information either from site or from office. Each individual work must be completed with minimum executing time as per site requirement. iii) The Agency must submit the details of communicating person in this regard along with his Mobile number & Email id.
Note:- Rate should be quoted inclusive of all taxes and duties including GST.
ELECTROTECH (BID ID -7570405)
JOY MAA TARA ELECTRICAL CO (BID ID -7640664)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Document
0.89 MB
BOQ
BOQ • 0.35 MB
Tender Documents
Tender Documents • 0.50 MB
Download all tender documents and submit your bid