Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.0 LAccepted-AOC | ₹7.0 L Quoted ₹7.2 L | L1 | Accepted-AOC Being Lowest |
| 2 | L2₹8.5 L+₹1.3 L (18.2%)Rejected-Finance | ₹8.5 L+₹1.3 L (18.2%) | L2 | Rejected-Finance Being not lowest |
Tender Value
₹8 L
EMD Value
₹16,000
Closing Date
15 Mar 2022, 6:00 pmClosed
AGE I Lansdowne
Asst Garrison Engineer (I) Lansdowne, Disst- Pauri Garhwal Pin-246155
REPAIR /MAINT OF VARIOUS CAP OF DG SET OIL INCINERATOR AND CONNECTED WORK UNDER AGE I LANSDOWNE
2022_MES_510813_1
8721/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AGE I Lansdowne
Class E Cat b i
6 documents required · 6 mandatory
₹500
AGE I Lansdowne
₹16,000
4 Jun 2022
28 Feb 2022
17 Mar 2022
28 Feb 2022
15 Mar 2022
3 Mar 2022
Amount
DG SETS (Part-I):- M&L for routine servicing of silent DG set 180 KVA Make- Kirloskar Jakson(IInd stage) with tunning, tightening of all nut/bolts etc Cleaning of fuel tank including replacing by S&F of following items:-
All as per Item No 1 here in above but Engine Oil filter complete all as specified and directed . (Make :kirloskar Jakson)
All as per Item No 1 here in above but Fuel filter complete all as specified and directed . (Make :kirloskar Jakson)
All as per Item No 1 here in above but Air filter complete all as specified and directed . (Make :kirloskar Jakson)
All as per Item No 1 here in above but Fuel pipe complete all as specified and directed . (Make :kirloskar Jakson)
All as per Item No 1 here in above but Water/air hose pipe complete all as specified and directed . (Make :kirloskar Jakson)
M&L for routine servicing of silent DG set 250 KVA Make-Alternator-CG and Engine-Greaves cotton (IIIrd stage ) with tunning, tightening of all nut/bolts,repair/replacement to control panel wiring with suitable size of copper cable, cleaning of fuel tank and including replacing by S&F of following items:-
All as per Item No 07 here in above but Engine Oil filter complete all as specified and directed . (Make :CG/Greaves cotton)
All as per Item No 07 here in above but Fuel filter complete all as specified and directed . (Make : (Make :CG/Greaves cotton)
All as per Item No 07 here in above but Air filter complete all as specified and directed . (Make :CG/Greaves cotton)
All as per Item No 07 here in above but AMF Controller unit complete all as specified and directed . (Make :CG/Greaves cotton)
All as per Item No 07 here in above butSpeed controller unit complete all as specified and directed . (Make :CG/Greaves cotton)
M&L for routine servicing of silent DG set 100KVA Make-Kirloskar(15Lakh gln P/H) with tunning, tightening of all nut/bolts, cleaning of fuel tank includin and replacing by S&F of following items:-
All as per Item No 13 here in above but Engine Oil filter complete all as specified and directed . (Make : Kirloskar)
All as per Item No 13 here in above but Fuel filter complete all as specified and directed . (Make : Kirloskar)
All as per Item No 13 here in above but Air filter complete all as specified and directed . (Make : Kirloskar)
All as per Item No 13 here in above but Fuel pipe complete all as specified and directed . (Make : Kirloskar)
M&L for routine servicing of DG set 62.5 KVA Make-Kirloskar (MH) with tunning, tightening of all nut/bolts, cleaning of fuel tank and including replacing by S&F of following items:-
All as per Item No 18 here in above but Engine Oil filter complete all as specified and directed . (Make : Kirloskar)
All as per Item No 18 here in above but Fuel filter complete all as specified and directed . (Make : Kirloskar)
All as per Item No 18 here in above but Air filter complete all as specified and directed . (Make : Kirloskar)
All as per Item No 18 here in above but Fuel pipe complete all as specified and directed . (Make : Kirloskar)
M&L for routine servicing of silent DG set 40KVA Make-Kirloskar Jakson(Record Office) with tunning, tightening of all nut/bolts, repair to radiator to avoid leakage including replacing by S&F of following items:-
All as per Item No 23 here in above but Engine Oil filter complete all as specified and directed . (Make :Kirloskar Jakson)
All as per Item No 23 here in above but Fuel filter complete all as specified and directed . (Make :Kirloskar Jakson)
All as per Item No 23 here in above but Air filter complete all as specified and directed . (Make :Kirloskar Jakson)
All as per Item No 23 here in above but Water/air hose pipe complete all as specified and directed . (Make :Kirloskar Jakson)
All as per Item No 23 here in above but Fuel pipe complete all as specified and directed . (Make :Kirloskar Jakson)
M&L for routine servicing of DG set 125 KVA Make-Kirloskar (Jharapani P/H, 2nd Lift, MH) with tunning, tightening of all nut/bolts, cleaning of fuel tank and including replacing by S&F of following items:-
All as per Item No 29 here in above but Engine Oil filter complete all as specified and directed . (Make :Kirloskar)
All as per Item No 29 here in before but Fuel filter complete all as specified and directed . (Make :Kirloskar)
All as per Item No 29 here in before but Air filter complete all as specified and directed . (Make :Kirloskar)
All as per Item No 29 here in before but Fuel pipe complete all as specified and directed . (Make :Kirloskar)
M&L for routine servicing of silent DG set 10KVA Make-Cummins (Telephone Exchange) with tunning, tightening of all nut/bolts, cleaning of fuel tank and including replacing by S&F of following items:-
All as per Item No 34 here in above but Engine Oil filter complete all as specified and directed . (Make :Cummins)
All as per Item No 34 here in above but Fuel filter complete all as specified and directed . (Make :Cummins)
All as per Item No 34 here in above but Air filter complete all as specified and directed . (Make :Cummins)
M&L for routine servicing of silent DG set 5KVA Make-Kirloskar of MRS and E/M office with tunning, tightening of all nut/bolts, cleaning of fuel tank and including replacing by S&F of following items:-
All as per Item No 38 here in above but Engine Oil filter complete all as specified and directed . (Make :Kirloskar)
All as per Item No 38 here in above but Fuel filter complete all as specified and directed . (Make :Kirloskar)
All as per Item No 38 here in above but Air filter complete all as specified and directed . (Make :Kirloskar)
Supply and filled engine oil 20W40 complete all as specified and directed .Make-Servo/castrol/MGO
Supply and filled coolant complete all as specified and directed. make : servo/castrol/MGO
M & L for replacement of AVR 125 KVA DG set upto 250 KVA DG set complete all as specified and directed .. Make - Kirloskar/Cotton Greaves
M & L for replacement of Battery lead suitable for 180 AH capacity, 1.5 mtr long including GM terminals one end copper lug and other end with gun metal terminals complete all as specified and directed .
M & L for servicing of self starter 24 volts including replacement of minor parts and testing of 40 to 180 KVA DG set for any capacity of DG Set complete all as specified and directed .
M & L for servicing of water pump and testing complete including replacement of water repair kit, gas kit and minor parts of any capacity of DG set complete all as specified and directed .
M & L for servicing of turbo charger including replacement of repair kit and minor parts of any rating of DG set complete all as specified and directed . by EIC.
M & L for replacing the self starter suitable for 180/125/100 KVA capacity of DG set of the existing make complete all as directed by EIC.
M & L for replacing the self starter suitable for 40/10 capacity of DG set of the existing make complete all as directed by EIC.
Replacement of Battery 12 volt 180 AH maintenance free battery complete all as specified and directed by EIC. Make:- Exide/standard/Amron/Luminous.
Replacement of Battery 12 volt 130 AH maintenance free battery complete all as specified and directed by EIC. Make:- Exide/standard/Amron/Luminous.
M & L for replacement of water pump for 180/100 KVA DG set complete all as specified and directed . Make : Greaves/Kirloskar
M & L for replacement of V Fan belt for 250/180/125/100 KVA DG set complete all as specified and directed . Make : Fenner/Denlop
M & L for replacement of V Fan belt for 62.5/40/10/5 KVA DG set complete all as specified and directed . Make : Fenner/Denlop
M & L for On load Change Over switch In Sheet Enclosure rating of 100 A complete all as specified and directed . cat No.IHCFTE0100 as per existing after taking out old U/S Make:L&T/havells/GE
M & L for On load Change Over switch In Sheet Enclosure rating of 400 A complete all as specified and directed . cat No.IHCFTE0100 as per existing after taking out old U/S Make:L&T/havells/GE
Cleaning/Scrapping out side of DG sets of capacity 5 KVA to 10 KVA properly painting with one coat zinc chloromate primer and two coats of best quality synthetic enamel paint etc complete all as specified and directed .
Cleaning/Scrapping out side of DG sets of capacity 40KVA to 250 KVA properly painting with one coat zinc chloromate primer and two coats of best quality synthetic enamel paint etc complete all as specified and directed .
OIL FIRED INCINERATOR (Part-II):- Dismantling electrical connection, water connection of Oil Fired Incinerator and dismantling the same for repairs by removing nuts & bolts, front door including fitting and removing out old defective parts and reassembling, cleaning, servicing, oiling and greasing the primary and secondary chamber for the smooth functioning complete all as specified and directed by Engineer-in-charge.
Dismantling electrical connection, water connection of venturi scrubbing system and dismantling the same for repair by removing Nuts & bolts, filter system including fitting and removing out old defective parts and reassembling, cleaning, servicing, oiling and greasing the first and second chamber complete all as specified and directed by Engineer-in-charge.
Dismantling electrical connection, water connection of front loading sliding system both inner and outer and dismantling the same for repair by removing nuts & bolts M.S. sheets, old defective accessories including fitting & removing out bend channels by welding and reassembling for smooth functioning complete all as specified and directed by Engineer-in-charge.
M & L for painting and to primary and secondary chamber with venturi scrubbing system by scratching old paint and preparation of surface for repainting by applying one coats of aluminium paint complete all as specified and directed by Engineer-in-charge.
M & L for Repair/Servicing of Oil Fired Incinerator burner complete all as specified and directed .
M & L for replacement of the following defective parts : Solenoid valve.15mm complete all as specified and directed . Cat part No.11379301
M&L for Diffuser plate assembly MI burner complete all as specified and directed . Cat part No.114711802
M&L for Burner nozzle GHP at degree Centigrade, complete all as specified and directed . cat part No.118117243.
M&L for Ignition transformer complete all as specified and directed . cat part No.11804601.
M&L for Sequential controller complete all as specified and directed . cat part no.860511600.
M&L for Photocell complete all as specified and directed . cat part No.86031111400
M&L for Thermo couple K type KER 710 for Secondary chamber complete all as specified and directed . cat part No.12000001
M&L for Limit switch for door with metallic Roller complete all as specified and directed . cat part no. WM00046111.
M&L for Contractor for burner/ID fan make siemens complete all as specified and directed . cat Part No. 3TF-30-02-0D 12.5 to 2 amps capacity
M&L for Relay for D fan motor-1 make siemens complete all as specified and directed . cat part No.34A5200-IB8-12.5 amps capacity.
M&L for Contractor for main control and burner chamber 3TF 2001-QAPO-4 complete all as specified and directed .
M&L for Contractor for P fan motor siemens cat part No. 3TF 3200 A1 complete all as specified and directed .
M&L for Timer complete all as specified and directed . Cat part No, 3PU 6020
M&L for Thermocouple K type SS310 for Primary chamber complete all as specified and directed . cat part No.WM00042083.
M&L for RTDPT-100 temp. sensor output complete all as specified and directed . Cat part No.WM00042073
M&L for RTD temp. controller 0-1200 Degree centigrade K type input complete all as specified and directed . cat part no.841115900.
M&L for Temp controller 0-600 degree Centigrade RTD input complete all as specified and directed . cat part no.WM00042034.
M& L for earthing with galvanised steel earth plate of size 600 x 600 x 6 mm thick burried directly in ground not less than 2.5 mtr below groud level with top edge of earth plate not less than 1.5 meters below ground level connected by 25x4 mm GI strip as earth lead by means of brass nuts and bolt, thimbles, check nuts, washers including concrete chamber of PCC 1:3:6 type C1 using 20 mm graded stone aggregate, with fair finish, inetrnal surface of concrete chamber shall be given internal dia 300mm X 300mm , 15 mm thick plaster in CM 1:4 funnel with wire mesh, RCC pit cover of 320 x 320 x 80 mm size (1:2:4) type B1 using 20 mm graded stone aggregate, adequate quantity of common salt, charcoal etc all, as shown in electrical plate No 3 of MES SSR Part-1(2009) and specified incuding and provision of GI strip upto 7.5 mtr long with 40 mm dia light grade GI pipe protection and watering pipe of GI 20 mm bore, Medium grade, including all excavation and earthn work and connecting the earth strip to an earthing test point/panel including testing on completion complete alll as specified and directed by Engr-in-charge Note:-(1) RCC pit cover shall be precast of RCC (1:2:4) type B1, 80 mm thick reinforced with XPM weighting not less than 4 Kg/Sqm in lieu of CI cover (2) Cost of addtional GI strip more than 7.5 mtr will be measured and paid seperately under relevant item
TRINITY CONSTRUCTION
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .