| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.7 CrAccepted-AOC REENA NIVAS EDAPPARA KANDIYIL KIZHAKKUMURI KAKKODI KERALA | KOZHIKODE | KERALA | 612906 | ₹1.7 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹1.7 Cr+₹74,212 (0.43%)Rejected-Finance | ₹1.7 Cr+₹74,212 (0.43%) | L2 | Rejected-Finance High Quote |
| 3 | L3₹1.9 Cr+₹15.1 L (8.65%)Rejected-Finance | ₹1.9 Cr+₹15.1 L (8.65%) | L3 | Rejected-Finance High Quote |
| 4 | L4₹1.9 Cr+₹16.7 L (9.59%)Rejected-Finance | ₹1.9 Cr+₹16.7 L (9.59%) | L4 | Rejected-Finance High Quote |
| 5 | Rejected-Technical | - | - | Rejected-Technical NOT MEETING PQ NORMS |
Tender Value
₹2.0 Cr
Closing Date
2 Aug 2017, 5:00 pmClosed
CHIEF EXECUTIVE OFFICER
PARK CENTRE, CYBERPARK, KSITIL SEZ, NELLIKODE P.O., KOZHIKODE, KERALA
TENDER FOR CONSTRUCTION OF COVERED PARKING FOR SAHYA BUILDING AT CYBERPARK KOZHIKODE
2017_CP_131207_1
CP/ITB/GN/PARKING/CLT/2017/06
Open Tender
Civil Works - Others
Item Rate
180 days
CYBERPARK KOCHIKODE
AS PER NIT
8 documents required · 8 mandatory
₹5,250
online
Exempted
PARK CENTRE, CYBERPARK KOZHIKODE
9 Feb 2024
18 Jul 2017
5 Aug 2017
18 Jul 2017
2 Aug 2017
18 Jul 2017
25 Jul 2017
Amount
PART-A CIVIL
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared
Felling trees of the girth (measured at a height of 1 m above ground level), including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material. Beyond 30 cm girth upto and including 60 cm girth
Earth work in rough excavation, banking excavated earth in layers not exceeding 20 cm in depth, breaking clods, watering, rolling each layer with ½ tonne roller or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up in embankments for roads, flood banks, marginal banks and guide banks or filling up ground depressions, with all lead and lift : All kinds of soil
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, with all lead and lift , disposed earth to be leveled and neatly dressed. Ordinary rock
Supplying and filling red earth/moorum whereever required , including watering, ramming, consolidating with power roller and dressing complete.
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, with all lift including getting out the excavated soil and disposal of surplus excavated soil as directed, with all lead. All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, with all lead and lift
Providing and laying in position Cement concrete 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand)
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately). All works upto plinth level for foundation footing.
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately). All works above plinth level upto floor V level for walls.
For columns
For drains
For staircases
For Plinth beams
Centering and shuttering including strutting, propping etc. and removal of form for :
Foundations, footings, bases of columns, etc. for mass concrete
Walls (any thickness) including attached pilasters, butteresses, plinth, stair and string courses etc. up to 3.50m.
Lintels, beams, plinth beams, girders, bressumers and cantilevers
Pre-cast reinforced concrete M20 (with coarse sand and graded stone aggregate 20mm) of any shape and size, machine mixed and mechanically vibrated including proper formwork, concreting, providing holes as directed curing, de-shuttering, lifting and stacking properly at places where directed, and erect in position, cost and conveyance of all materials and labour charges, but excluding cost of reinforcement for drain cover slab.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500 D or more.
Laterite masonry using neatly dressed stones of size 35x20x20cm.in CM 1:6 for foundation and basement including cost and conveyance of all materials and labor charges, curing, etc. complete.
Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) for manholes etc.
15 mm cement plaster on sides of masonry wall of mix: 1:4 (1 cement: 4 coarse sand)
Smooth finishing of the exposed surface of R.C.C. work with 6 mm thick cement mortar 1:3 (1 Cement : 3 fine sand).
Providing and laying 60mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand/6mm aggregate, compacting and proper embedding/laying of interlock paver block in to the bedding through vibratory compaction using plate compactor filling the joints with fine sand and cutting of paver block as required shape, size, pattern finishing and sweeping extra sand etc. all complete as per the direction of Engineer-in-charge.
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment).(Precast C.C. kerb stone shall be approved by Engineer-in-charge).
Painting runway/taxi track/apron marking with adequate nos of coats to give uniform finish with road marking paint of superior make as approved by the Engineer-in-charge, i/c cleaning the surface of all dirt, scales, oil, grease and other foreign material etc. and lining out complete. New work (Two or more coats)
Providing and making M 20 RCC column base with foundation bolts as per drawing for fixing street light poles including cost and conveyance of all materials, labour charges, excavation, PCC foundation, shuttering, fixing charge of foundation bolts, reinforcements, PVC pipes etc. complete.
Providing and fixing 100mm , 4kgf/sq.cm.pvc pipes of required lengths in RCC wall for weep holes
Providing and laying non-pressure NP2 class (light duty) R.C.C.pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints, excavation for trenches up to 1.50m depth and back filling & disposal of surplus earth, connecting with existing chambers and making good the chambers by sealing the gaps in brick masonry CM 1:6 and plastering etc. complete :
300 mm dia. R.C.C. pipe
450 mm dia. R.C.C. pipe
600 mm dia. R.C.C. pipe
Providing and fixing C.I. cover with frame (Light duty ,Weight not less than16 Kg) 450x450 mm size, Cost include fixing CI cover in RCC cover slab 1:2:4 including all shuttering , reinfocements, plastering, painting cover with black enamel paint, labour, conveyance etc complete
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position etc. complete.
Fencing with angle iron post placed at required distance embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with horizontal lines and two diagonals interwoven with horizontal wires, of barbed wire weighing 9.38 kg per 100 m (minimum), between the two posts fitted and fixed with G.I. staples, turn buckles etc. complete. (Cost of posts, struts, earth work and concrete work to be paid for separately). Payment to be made per metre cost of total length of barbed wire used. With G.I. barbed wire
Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade : Two or more coats on new work
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : Water thinnable cement primer
Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm)
Providing and fixing in position 12mm thick bitumen impregnated fiber board conforming to IS: 1838, including cost of primer, sealing compound Grade-A in expansion joints.
Providing and fixing sheet covering over expansion joints with iron screws as per design. Fibre cement board 6 mm thick as per IS: 14862. 150mm wide
Supplying, Installing, Testing & Commissioning of pipes and conveying to position; and jointing to true lines and gradients, PVC pipe of 200 mm dia., IS 4985(6kg/cm2), jointing the pipe line as per specification, testing the pipe line after installation to the specified hydrostatic test pressure including trenching, refilling & Supplying, Installing specials like bends, couplers, sockets, connections etc. as per provisions of IS: 1742-1983 (Code of practice for building drainage) complete.
Providing and fixing hand rail of approved size and drawing by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, M.S. tube
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.
On steel work
For Truss work
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position ,including welding and bolted with special shaped washers etc. complete.
Providing and fixing precoated galvanised iron profile sheets (size, shape, colour and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Flashings/ Aprons.( Upto 600 mm)
Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge : In cement mortar
Providing and fixing Anchor bolts/'J' bolts including nuts and washers complete.
Drilling suitable holes in reinforced or plain cement concrete with power driven drill machine to a minimum depth of 100mm upto 200mm in RCC beams, lintels, columns, walls and slabs to introduce steel bars/anchor bolts including fixing the steel bars /anchor bolts in position using epoxy resin anchor grout of approved make but excluding the cost of reinforcement/anchor bolt, all complete as per direction of Engineer-In- Charge. Upto and including 12mm dia.
PART B - ELECTRICAL
Prices are for the complete materials and labour required to form a fully functional installation complying to relevant standards irrespective of whether all those items are listed below, shown on drawings or described in the specifications. The contractor's scope shall include supply of materials, taking delivery of the materials at site including unloading and leading charges, storage, shifting to work site, installation, testing, commissioning and warranty.
AUTHORITY APPROVALS
The contractor's scope shall include preparation of all drawings, submitting and getting approval from Electrical Inspectorate, submitting of completion certificates and arranging inspection, getting sanction and energisation certificates from Electrical Inspectorate & KSEB, obtaining power allocation & permanent power connection, etc. and commissioning of the whole installation in the premises. All statutory payments will be reimbursed on production of the original receipts.
ELECTRICAL PANEL BOARDS
Fabrication, supply, installation, testing and commissioning of electrical panel boards as per details given below, approved electrical single line diagrams, specifications, etc. as required
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, owder painted including earthing etc. as required with MCB/RCCB/metering/RYB indication lamps etc as required. 8 way (8+24), TPN, MCB DB, double door, 40A, FP, Isolator 40A, 30mA, FP, RCCB 25A, TP MCB - C CURVE
MV CABLE LAYING Supplying and laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation,sand cushioning,protective covering ,refiliing and throgh the existing bridge from electrical service room.
4C x 16sq.mm 1.1kV cu Cable
3CX4sqmm 1.1kv cu cable
8SWG GI wire along with cable for pole earthing(2 run along with power cable) at 0.5mtr below ground level for conductor including connection/termination with GI thimble etc.
CABLE TRAYS Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
225 mm width X 50 mm depth X 1.6 mm thickness
MV CABLE END TERMINATION Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
4 X 16 sq. mm (28mm)
3 X 4 sq. mm (28mm)
WIRING
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. 3x2.5sqmm
Thermoplastic IP67, weather proof,heavy jet water proof,corrosion proof and shock proof cable junction box with 5P terminal suitable for 4sqmm and with 3 nos M20 polymide glands IP68
LIGHT FITTINGS Supply, installation, testing and commissioning of LED street light fittings to be mounted on octagonal galvanised pole of 4mm thickness as required.
The pole shaft shall have octagonal cross section and shall be continuously tapered with single longitudinal welding. The poles shall be designed to withstand the maximum wind speed as per IS 875. All pole shafts shall be provided with the rigid flange plate of suitable thickness with provision for fixing foundation bolts. The poles shall have door of approximate 500mm length at the elevation of 500mm from the base plate, with suitable control box with MCB, terminal connectors for loop in loop out. . The door shall be vandal resistant and shall be weather proof to ensure safety of inside connections. The door shall be flush with the exterior surface and shall have suitable locking arrangement.There shall also be suitable arrangement for the purpose of earthing and the pole should be earthed as per standared.1No. X 40W LED street light fitting( Wipro Model No LR02-451-XXX-57-XX or equivalent)- die-cast aluminium housing, street light optics and IP66 rating with prewired control gear and all other accessories suitable for operation of 240V, 50Hz single phase ac supply on 6m single arm pole
1No. X 40W LED street light fitting - die-cast aluminium housing, street light optics and IP66 rating on 8m single arm pole
Supply and installation of 60W LED, Bulk Head Light Model No. Klite ID : 4037(or equivalent) Dim: 356 x356 x 146 mm complete with all accessories including termination etc.
Supply and installation of KLITE.5561 16WLED (or equivalent) Bollard is integrated with glare free reflector system encased in clear UV protected polycarbonate diffuser with diecast aluminium flat top cover,having IP65 degree of ingress protection, electronic driver of BAGmake, 6kV SurgeProtection Device of BAGmake, all pre wired and ready for use including termination, necessary foundation with nut bolts. DIm:Ø166x895mm.Standard Colour :graphite grey with HENSEL make 2 way junction box model:KF 5056(or equivalent)Warm Colour
Supply and installation of KliteID:6789,ASTON2,2x60WLED(or equivalent) Supplied with 10KV surge protection device. Standard Colour: Graphite Grey. IP68LEDModule, IP67 Driver / Connectors With HENSEL make 2 way junction box model:KF 5056(or Equivalent) including termination, necessary foundation for fixture with nut bolts
Supply and installation of KliteID:5380 (or equivalent) 30WLED, WarmWhite, Dim:Ø420x400mm,StandardColour:GraphiteGrey. supplied with 6KV A surge protector. IP65, Luminaire provided with heavy duty ballast and an integral controlgear/LED driver. Suitable for operation on 240V, 50Hz single phase ac supply with Klite ID: KP4802, Flat Lighting Pole, Ht.3050mm. Galvanized pole as per IS Standards, Hot dip zinc coat to IS Standards, The pole is provided with built-in control box including service door and safety chain. The control gear tray is prewired with 2.5sq.mm Cu cable, MCB & heavy duty terminal block for loop-in loop-out arrangement. The pole is coated with epoxy zinc rich primer and finished with polyurethane based paint.
Supply and installation of KliteID:6953, Ritu Bollard (or equivalent). 6W LED,Dim:130x200. StandardColour:Graphite Grey. IP54. Aluminium Diecast, including termination, necessary foundation for fixture with nut bolts, HENSEL make 2 way junction box model:KF 5056 (or equivalent) warm colour
Supply and installation of KliteTRIOSCAPE-SPIKE,ID:7008 (or equivalent),3WLED, Dim:102x73x360,Standard Colour:Graphite Grey.BeamAngle:25°Supplied with 1m cable. IP 65 With HENSEL make 2 way junction box model:KF 5056 including termination, necessary foundation for fixture with nut bolts
Supply and installation of KliteID:5563.AjnaBollard(or Equivalent), 16WLED Bollard is integrated with glare free reflector system encased in clear UV protected polycarbonate diffuser with diecast aluminium flat top cover, having IP65 degree of ingress protection, electronic driver of BAG make, 6kV SurgeProtection Device of BAGmake, all prewired and ready for use. DIm:Ø195x155mm. Standard Colour : Graphite Grey. Warm Colour,including termination, necessary foundation for fixture with nut bolts
18W,240v high efficiancy LED linear lamp which have Short circuit and surge protection for enhanced reliability and longer service life of driver withsturdy vandal resistant polycarbonate housing with silicon gel gasket,IP65 rated with necessary clips,rods etc for installation.
40W,240V Al Die cast Housing and Frame, powder coated,High efficiency flood light with toughned glass,IP66,Complete assembly with LED, Driver and accessories pre- wired up to terminal block in connector compartment with PG7 cable gland,Integral control gear compartment with connector also with neccessary bolts,rods etc for installation.
80W,240V Al Die cast Housing and Frame, powder coated,High efficiency flood light with toughned glass,IP66,Complete assembly with LED, Driver and accessories pre- wired up to terminal block in connector compartment with PG7 cable gland,Integral control gear compartment with connector also with neccessary bolts,rods etc for installation.
RUBICON PROJECT MANAGEMENT P LTD
Malayil Builders Private Limited
Lee Builders
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .