Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.5 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder, Hence accepted | |
| 2 | L2₹28.2 L+₹45,122 (1.62%)Rejected-Finance 77 KAILASH PURI BIKANER RAJASTHAN PIN 334001 | BIKANER | BIKANER | RAJASTHAN | 334001 | L2 | Rejected-Finance Not Lowest Bidder, Hence Rejected | |
| 3 | L3₹30.8 L+₹3.0 L (10.8%)Rejected-Finance 1 SADHANA SOCIETY DEV BAUG DEVBAUG BHAVNAGAR GUJARAT 364001 | BHAVNAGAR | GUJARAT | 364001 | L3 | Rejected-Finance Not Lowest Bidder, Hence Rejected | |
| 4 | L4₹31.9 L+₹4.2 L (14.9%)Rejected-Finance 77 KAILASH PURI BIKANER RAJ C 15 SWC JAIPUR | BIKANER | RAJASTHAN | 331801 | L4 | Rejected-Finance Not Lowest Bidder, Hence Rejected |
Tender Value
₹33 L
EMD Value
₹66,000
Closing Date
10 Jan 2022, 6:00 pmClosed
GE (AF) Phalodi
GE (AF) Phalodi
PROVN OF MISC WORKS SERVICES FOR RIO ROOM AT SRE BLDG AND SPECIAL REPAIRS TO STAIRCASE OF WATCH TOWERS AT AF STN PHALODI.
2021_MES_494235_1
8392/A/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (AF) Phalodi
Class D Cat a(i)
7 documents required · 7 mandatory
₹500
GE (AF) Phalodi
₹66,000
Yes
16 Feb 2022
13 Dec 2021
12 Jan 2022
13 Dec 2021
10 Jan 2022
27 Dec 2021
Amount
S & F for Aluminum Anodized snap Grid 605x605 mm frame work using aluminum anodized perimeter channel 0.55 mm thick with two uneual flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre / intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (n exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm eachwith lips of 10.5 mm fixed to the intermediate channel at 457 mm centre to centre, including and finally treated the exposed surface with two colangesnof 20 andats of first quality synthetic enamel paint over a coat of primer complete, including 6 mm Dia hangers (upto 1200 mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3mm sie 60 mm long and expansion hold fasteners 12,5 mm dia 40 mm long including 12 mm thick gypsum board/ tiles for insulation and acoustic purpose of size 60 cm x 60 cm fixed with screws with staples on snap grid complete all as specified and directed.
M & L for precast cement concrete 1:5:8 (using crushed stone aggregate) block masonry with solid blocks exc 10cm in width and setting in cement and sand mortar 1:6 complete all as specified and directed.
M & L for rendering 10mm thick in cement mortar 1:6 on fair faces of PCC block or concrete surfaces including finishing plaster surface even and smooth without using extra cement complete all as specified and directed.
M&L for preparation of new plastered surfaces and applying two coats of cement base paint of approved shade on walls including one coat of alkali resistant primer complete all as specified and directed.
M & L for Anodised aluminium frame for doors, windows, ventilators Powder Coating with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
M & L for Anodised aluminium door shutters, aluminium section powder coating weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified and directed.
M & L for 5.5mm thick sheet glass, ordinary quality and glazing with oil putty in square exc 0.5 sq. m in each pane complete all as specified and directed.
Demolition of cement concrete (un-reinforced) in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) of any description complete all as specified & directed.
M & L for TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified and directed.
M & L for TMT bars 5mm to 8mm dia, cut to length, bent to shapes required, including cranking, bending spirally for hooping for stirrups, spacers and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. complete all as specified & directed.
S&F for Reinforced cement concrete M-25 (using 20mm graded crushed stone aggregate) in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified & directed.
S&F for MS rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete all as specified & directed.
S&F for chequered or plain MS plate, channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as specified & directed.
M & L two coats of synthetic enamel paint over a coat of Red oxide primer including preparation of newly steel surface any description complete all as specified and directed.
Taking down cement or cement lime plaster any description, on brick or stone/PCC block walls, etc. including raking out joints, hacking for key & scrubbing down with water, etc. &and removal all rubbish material to a distance n.exc 50m and depositing where directed complete all as specified & directed.
M & L for rendering 10mm thick in cement mortar 1:4 on fair faces of brick work, PCC block masonary or concrete surfaces of walls, finished even & smooth without using extra cement complete all as specified and directed.
M & L for plastering 5mm thick on concrete surface of ceiling in CM 1:3, finished even and smooth without using extra cement complete all as specified and directed.
M & L for preparing newly plastered surfaces and applying three coats of white wash on ceiling/soffits of chajjas complete all as specified and directed.
M & L for preparing newly or previously untreated plastered wall surfaces and applying two coats of oil bound distemper (OBD) over and including one coat of alkali-resistant priming paint complete all as specified and directed.
M & L for preparing old decorative plastered surfaces of walls and applying one coat of cement base paint of first grade quality, complete all as specified and directed.
Dismantling floor, hearth or wall tiling, including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M & L for non skid ceramic tiles (coloured) 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over and including screed bed or bedding layer of mortar, 10 mm thick, in cement mortar 1:6, for laying floor finishes complete all as specified and as directed.
M & L for 300x200x7 mm thick glazed ceramic coloured tiles as on vertical surfaces such as skirting or dado set & jointed in neat cement slurry & pointed in coloured cement to match the shade of tiles and including 10mm thick rendering in CM 1:3 complete all as specified and directed.
M & L for 20-25mm thick machine cut Kota stone slab flooring laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing over and including screed bed or bedding layer of mortar, 10 mm thick, in cement mortar 1:3, for laying floor finishes complete all as specified and directed.
M & L for 20-25mm thick machine cut Kota stone slab as in risers of steps, skirting, dado and pillar laid over cement rendering and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing, over and including 10mm thick rendering in CM 1:3 complete all as specified and directed.
Taking down chowkats or shutters of any description not exceeding 1.50 Sqm each with shutters (without taking off shutters from the frame) complete all as specified and directed.
S&F second class hard wood 35mm thick plain framed, panelled shutter (two panel) with lock rail and panel of 9mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed.
S&F second class hard wood 35mm thick glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and directed.
S & F for Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing as applicable to item 08095 given in SSR Part – II (2010) complete all as specified and directed.
S & F for Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails mild steel frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement, suppy and fixing in the frame at site complete all as per specifications and drawings as applicable to item 08080 given in SSR Part–II complete all as specified and directed. Note :- The PVC doors shall be fixed as per Manufacturer's instructions and as directed.
M & L for Anodised aluminium door shutters, aluminium section weighing not less than 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, 150mm long handles 2 Nos in each door, 100 mm long hinges 03 Nos in each door and 150mm lomg tower bolts 02 Nos in each door, anodised aluminum snap beading screws etc. complete all as specified and directed.
M & L for preparation of new or previously untreated wooden or wood based surfaces of any description not otherwise described over 10 cm width or girth and applying two coat of synthetic enamel paint of 1st grade quality over and including one coat of pink primer complete all as specified and directed.
S&F 150mm long aluminium anodised, barrel tower bolts(ISI marked) of extruded section and fixed complete all as specified and directed.
S&F 200mm long aluminium anodised, barrel tower bolts(ISI marked) of extruded section and fixed complete all as specified and directed.
S & F 150mm size extruded aluminium alloy handles, fabricated type, anodised, ISI marked complete all as specified and directed.
M & L for 100mm butt hinges, medium weight, cold rolled mild steel, ISI marked and fixed complete all as specified and directed.
S & F 250 mm long aluminium alloy, anodised sliding door bolts (ISI marked) with bolt not less than 16mm dia with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections of cast aluminium alloy and fixed complete all as specified and directed.
S & F of galvanised mild steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks, or galvanized wire staples complete all as specified and directed.
S&F in repair of 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
S&F in repair water closet vitreous china squatting pan "Orissa pattern" size 580mmx440mm white with integral foot rests, 'P' or 'S' trap, including connection to trap, and flushing cistern, antisyphonage pipe etc complete making good to floor with PCC bedding complete all as specified and directed.
S&F in repairs, bib taps, cast copper alloy, with crutch or butterfly handles, screwed down, screwed for iron pipe or brass ferrule for 15mm bore complete all as specified and directed.
S&F in repair hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed.
M & L for 50mm thick PCC 1:3:6 type C-1 using 20mm graded crushed stone aggregate as in plinth protection finished even and smooth without using extra cement complete all as specified and directed.
Demolition of reinforced cement concrete in roofs, floors (other than ground floors), beams, chajjas, fascias, fins and similar works (reinforcement cut as reqd to facilitate demolation) complete all as specified and directed.
Formwork to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and directed.
S&F for Reinforced cement concrete M-25 (using 20mm graded crushed stone aggregate) in Columns, pillars, piers, posts and struts complete all as specified & directed.
M&L for screed bed or bedding layer of mortar, 15 mm thick, in cement mortar 1:4, with integral water proofing compound @ 3% of cement finished even and smooth without using extra cement complete all as specified and directed.
Supply only water proofing compound ISI marked.
S&F for APP based polymeric membrane not less than 3mm thick, weighing not less than 3.5 Kg/sqm , reinforced with polyster non-woven fabric (weighing not less than 150 gm/sqm and upper side of membrane thermally insulated with white mineral gravel finish, informaly embadded during manufacturing process shall only be used. It shall be laid by torch application,side overlaps shall be 75mm and the ends shall be 100mm and all over laps shall be sealed by torch application including applying a coat of cold applied bitumen primer conforming IS:[email protected]/sqm complete all as specified and directed.
S&F in repair dash through bolts of dia 6 to 8mm and length not less than 80mm including drilling holes using electronic drill machine in concrete / masonry work complete all as specified and directed.
S&F in repair 40mmm thick PPGS (Pre-painted galvanized steel) PUF ecofriendly panel board comprising of 0.50mm thick pre painted MS sheet face panel sandwitched with PUF (Polyurathane Foam) injected to achieve foam density not less than @ 40 Kg/Cum complete all as specified and directed.
Taking down chowkats or shutters of any description exceeding 1.50 Sqm but not exc. 4.0 Sqm each with shutters (without taking off shutters from the frame) complete all as specified and directed.
Taking down carefully existing copper/aluminium point wiring (light/fan/sockets) complete with all accessories such as switches sockets ceiling rose, wall bracket etc and removing dismantled material and making good disturbed surface of walls/floors etc matching with existing surface etc complete all as specified and directed
M & L for point wiring for one light / fan/bell point controlled by one switch with 1.5 Sqmm PVC insulated, sheathed multi strand copper conductor cable FR-LS in PVC casing & caping ISI marked, steel terminal sunken boxes and 3 mm thick phenolic laminated sheet top cover for sunken boxes flush to surface 1.5 Sqmm copper conductor cable FR-LS connected to common earth dolly complete all as specified and directed.
All as per item No 56 but for socket 5 Pin, 5 Amp 230 Volt on same board.
All as per item No 56 but for one socket point outlet 3 Pin, 5 Amp 230 Volt on independent board.
All as per srl item No. 56 (here-in-before) but for 3 pin 15 Amp socket out let by using 4 Sqmm PVC insulated sheathed copper conductor cable FR-LS multi strand on independent board including provn of 4 Sqmm sheathed, multi stranded copper conductor cable FR-LS continues as earth wire connected to earth dolly etc complete all as specified and directed.
Supply anf Fixing switch piano flush type, 5 Amp 240 Volt, AC (ISI Marked) one way etc complete all as specified and directed.
S&F bell push flush type, 5 Amp 240 Volt complete all as specified and directed.
S&F Buzzer, Dingdong AC, 230 Volt complete all as specified and directed.
S&F one socket flush type outlet 3 Pin 5 Amp, 230 volts AC complete all as specified and directed.
S&F Switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type universal 230 volts AC complete all as specified and directed.
Supply and Fixing LED batton fitting 1 x18/20 Watt, 6000K, 4" complete fitting connection with 2 core flexible cable 23/0.00076 from ceiling rose to tube fitting connection etc complete all as specified and directed.
S&F Ceiling fan regulator flush type electronic step type of suitable wattage, 230V suitable for ceiling fan etc complete all as specified and directed.
S&F ceiling rose surface bakelite 65mm x 50mm, 2 to 3 terminals with back plate etc complete all as specified and directed.
S&F LED light fitting, 1X25 watt,5700 K complete with tuff net glass protection IP:66, fixed to walls with GI bracket made out of suitable size of light grade pipe 32 mm dia tubing upto 1.2 mtr length bent to shape with 02 sets of MS clamps made out of 25x3 mm MS flat iron with suitable bolt and nuts and testing etc complete all as specified and directed.
Supply and fixing double door sheet metal enclosure made out of CRCA mild steel sheet concealed surface mounting TPN, 4 way, 415Volt, suitable for fixing MCBs, isolators etc including taking down old complete all as specified and directed.
S&F MCB TPN 63 Amps C curves MCB repturing capacity 10 KA etc complete all as specified and directed.
S&F MCB 6 Amp to 32 Amp SP capacities 'C' series 10KA rupturing capacaity complete all as specified and directed.
Taking down serviceable/unserviceable ceiling fans 1200mm/1400 mm sweep 230 V, AC, single phase from ceiling, dismantling the ceiling fan and taking out complete rewinding (if unserviceable) the same with super enameled copper winding wire of existing gauge & size including throughly cleaning all the components of fan, oiling varnishing the fan with and including replacement of rusted/unserviceable nuts, bolts, split pin, rubber reel, flexible twin core copper cable of size 23/.00076 approximate one metre long for each fan, machine screws and painting the fans etc, and refixing the repaired fan to existing place complete all as specified and as directed.
M & L for earthing with galvanized steel plate electrode 600 x 600 mm x 6 mm size directly burred in ground vertically earth pit not less than 2.25 meter deep below normal ground level with top edge of the earth plate not less than 1.5 m below normal ground level surrounded with coal dust and common salt filling in alternative layers of 15 cm thick each connected to and including GI earth wire 4 mm dia by means of GI nuts, bolts, check nuts & washers etc connecting to earthing test point, main switch board and including 15 mm dia GI pipe light grade for protection of earth lead from earth plate upto 5 mtr and 20 mm dia GI pipe medium grade connected with funnel having wire mess for watering purpose including necessary excavation and earth work, PCC (1:2:4) type B-1 (using stone aggregates) for earthing pit, 10mm thick cast iron cover with angle iron frame all as specified and shown in electrical plate No 3 of SSR Part-I and testing complete all as specified and directed.
M & L for XLPE screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty)with stranded aluminum conductor, 1100 volts grade, earth type cross sectional area 25 Sqmm 4 core LT UG cable laid in trenches/through pipe/fixed along pole or in duct with necessary angle iron support,clamp,nut bolts etc. complete all as specified and directed.
Supply and laying LT XLPE insulated screened PVC bedded, galvanised steel strip or wire armoure, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 95 Sqmm 3.5 Core complete all as specified and directed.
Excavation in trenches, n.exc 1.5m wide & n.exc 1.5m in depth for foundation & getting out in Soft/loose soil for laying of cable complete all as specified and directed.
Removal of surplus soil to a distance not exceeding 50 mtr away and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cms thick in soils complete all as specified and directed.
Material and labour for dry tibba sand in trenches cushioning to under ground cable spreading, levelling hand punning complete all as specified and directed. Note- Punned down thickness will be measured for payment purpose.
Supply and lay un reinforced precast concrete cable covers LV Type 2, flat, size 300mm x 180mmx 40mm complete all as specified and directed.
Boring of holes under road, pavement,Run way,Taxi track, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 140 mm dia suitable for 0.4 mpa working pressure including pipe jointing and cable pulling complete all as specified and directed.
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity 1.5TR complete all as specified and directed.
Supply & fix single pointed Air termination Aluminium rod 12mm dia, 300mm long complete all as specified and directed.
S&F Auminium strip 25x3.15mm complete with saddles and fixing screws for roof/down conductors and fitting the strip complete all as specified and directed.
M & L for earthing with galvanized steel plate electrode 600 x 600 mm x 6 mm size directly burred in ground vertically earth pit not less than 2.25 meter deep below normal ground level with top edge of the earth plate not less than 1.5 m below normal ground level surrounded with coal dust and common salt filling in alternative layers of 15 cm thick each connected to and including GI strip 32x6mm as earthing lead by means of GI nuts, bolts, check nuts & washers etc connecting to earthing test point, main switch board and including 40 mm dia GI pipe light grade for protection of earth lead from earth plate upto 5 mtr and 20 mm dia GI pipe medium grade connected with funnel having wire mess for watering purpose including necessary excavation and earth work, PCC (1:2:4) type B-1 (using stone aggregates) for earthing pit, 10mm thick cast iron cover with angle iron frame all as specified and shown in electrical plate No 3 of SSR Part-I and testing complete all as specified and directed.
M&L test terminal block phosphorus bronze 75X75X25 mm, drilled and screwed including 3 Nos. 8mm dia 25mm long hex. head screw complete all as specified and directed.
M&L Cutting chases, pinning in on brick walls. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring,etc., and making good, cutting not exc 10 cm girth complete all as specified and directed.
S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 240 volt 20Amps complete all as specified and directed.
S&F Supply and fixing LED luminaire 600 mm x 600 mm,35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
S&F Sub main wiring with two single core cable PVC insulated unsheathed of copper multi strandard conductor cable of size 4 sqmm, 1100 votls grade drawn through concealed PVC conduit medium duty and including PVC insulated 2.5 sqmm unsheathed multistranded FR-LS copper conductor cable for earth continuity and connected to common earth dolly complete all as specified and directed. Note:- Two lengths of 4 Sqmm and 1 length of 2.5 sqmm cable, 20mm PVC Conduit 20mm will be measured as one length.
S&F Sub main wiring with two single core cable PVC insulated unsheathed of copper multi strandard conductor cable of size 2.5 sqmm, 1100 votls grade drawn through concealed PVC conduit medium duty and including PVC insulated 1.5 sqmm unsheathed multistranded FR-LS copper conductor cable for earth continuity and connected to common earth dolly complete all as specified and directed. Note:- Two lengths of 2.5 Sqmm and 1 length of 1.5 sqmm cable, 20mm PVC Conduit 20mm will be measured as one length.
S&F MCB SPN 40 amp 'C' curves MCB repturing capacity 10 KA etc complete all as specified and directed .
M&L for chemical earthing with copper earth plate electrode 90 cm X 60 cm X 5 mm buried directly in ground (earth pit not less than 3.0 mtr deep below ground level) with top edge of the plate not less than 2.25 mtrs below normal ground level,connecting to copper strip 32 X6 mm as earthing strip by means of bolts,nut check nut and washers protected with and including 40 mm dia medium grade GI pipe,necessary excavation and earth work,magnesium sulphate (80 Kg) ),charcoal (4 Qtl) and common salt (4 Qtl) filling,watering arrangement with 20 mm GI pipe medium grade including PCC pit with pre cast RCC (1:2:4) cover ,GI funnel with test point,testing (all as shown in electrical plate No 5 and commissioning complete all as specified and directed. Note:- On testing ,after completion ,if the earth resistance below 1 Ohms is not obtained ,earthing will rejuvenated at no extra cost till the desired earth resistance is obtined.
Supply and fix Copper strip 20 x 3.15mm with saddels and fixing screws for roof conductors and down conductors above ground ,Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chasses or burried in ground or drawn in conduit/ pipe or fixed to poles or fixed to wall on insulators or any other indicated situation for loop earthing etc as required complete all as specified and directed.
S&F ON Load change over switch 4 pole 250 Amps in sheet metal enclosure complete all as specified and directed.
Note :- (i) Cost of necessary tools and plants such as ladders, hydra, scaffolding etc for repair shall be deemed to be included in the quoted rate. (ii) The maximum height of repair for Ser Item Nos. 3, 4, 12, 16, 17, 18, 20, 51 & 53 of BOQ is 12 Mtr.
Beenu Co. Company
KRISHNA CONSTRUCTION COMPANY
M/S SOLANKI GENERAL SUPPLIERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .