| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹58.5 LAccepted-AOC | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹58.9 L+₹33,779 (0.58%)Rejected-Finance | L2 | Rejected-Finance Higher bid | |
| 3 | L3₹63.4 L+₹4.8 L (8.28%)Rejected-Finance 448 MUZAFFAR AHMED STREET KOLKATA 700 016 | KOLKATA | KOLKATA | WEST BENGAL | 700016 | L3 | Rejected-Finance Higher bid | |
| 4 | L4₹64.9 L+₹6.4 L (10.9%)Rejected-Finance MOSAT HARIPUR RD VILL P O HARIPUR DIST HOOGHLY PIN 712701 | HARIPUR | HOOGHLY | WEST BENGAL | 712701 | L4 | Rejected-Finance Higher bid | |
| 5 | L5₹65.7 L+₹7.2 L (12.3%)Rejected-Finance 90 E BECHARAM CHATTERJEE ROAD KOLKATA 700034 | KOLKATA | KOLKATA | WEST BENGAL | 700034 | L5 | Rejected-Finance Higher bid |
Tender Value
₹68.7 L
EMD Value
₹1.4 L
Closing Date
30 Jun 2021, 1:00 pmClosed
EE, South 24 Pgs Elect Divn
57/2 DH Road
Extension of the CCU at Diamond Harbour Govt Medical College and Hospital, Diamond Harbour, South 24 pgs.
2021_WBPWD_332598_1
WBPWD/EE/S24PED/eNIT02/21-22
Open Tender
ELECTRICAL WORKS ORG
Item Rate
60 days
Diamond Harbour
Please refer Tender documents.
3 documents required · 3 mandatory
₹1.4 L
South 24 Pgs Elect Divn
7 Jan 2022
9 Jun 2021
2 Jul 2021
9 Jun 2021
30 Jun 2021
15 Jun 2021
14 Jun 2021
Amount
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & nsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish. [only PVC Rigid Conduit on ceiling and remaining portion concealed](Avg run - 8Mtr )
Do ---- do – to 240 V 6A 5 pin plug point incl. S&F 240 V 6A 3 pin Modular plug socket & Modular switch (Brand approved by EIC) incl. S&F earth continuity wire, fixed on Board.
Supply & Fixing 240V , 4 Nos. 16A, 6 Pin Modular Type plug socket with 4 Nos. 16A Modular type switch(Brand approved by EIC), without plug top on 2 Row 12 Module GI Modular type switch Board with 2 Row 12 Module top cover plate imbedded in the wall incl. S& F switch Board and top cover plate and making necy. connections with PVC Cu wire and Earth continuity wire etc.
Supply & Fixing 240 V, 16 A, 6 pin Modular type plug socket -2nos (Brand approved by EIC) with 16A Modular type switch-2nos, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 16 A, 6 pin Modular type plug socket (Brand approved by EIC) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 6 A, 5 pin Modular type plug socket (Brand approved by EIC) with 6A Modular type switch, without plug top on 4 Module GI Modular type switch board with 3 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 2x 6 A, 3 pin Modular type plug socket (Brand approved by EIC) with 6A Modular type switch, without plug top on 6 Module GI Modular type switch board with 3 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), incl. S&F 1no 240 V, 16 A, 3 pin Modular type plug top (Brand approved by EIC) and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire as per GS.
Supply, Fixing of 250V Timer DB [equivalent of 8 way SPN Double Door DB in size)] with steel sheet enclosure double door, phosphitised powder coated, neutral bar, Din Rail with IP-43 protection comprises with 1 no. 20A/25A DP MCB ('C' Curve, 10 kA,), 1 no. 24 hours programmable Time Switch (ABB/Crabtree/L&T) with minimum switching time of 15 miniutes and 1 no. 18A/25A 2 pole contactor(ABB/Crabtree/L&T) complete with AC Starter (ABB/Crabtree/L&T) with Inner-Outer Plate & internal wiring by suitable size of copper wire including 1 no. Auto Mannual bypass Toggle Switch and provision for earthing attachment including LED indication light for running condition.(For 1.5 / 2.0 TR Single operation). (Make:- ABB/Crabtree/L&T) with locking arrangement.
Supply & Fixing of LED Recessed full open 2'×2' Tile Glare free uniform illumination with longer life & less maintenance.(Crompton make- Cat No. - LCTLRNE-36-FO-CDLor equivalent of Philips/Havells
S & F 450 mm sweep, 230V, 50Hz, A.C. wall bracket fans including connection by 1.5 sq. mm. P.V.C./Cu wire (Make-Orient Electric, Make- Wall Tornado /equivalent crompton as per direction of EIC.
Supply and drawing 1.1 KV grade 4x16sq.mm +2x4 sq.mm single core PVC insulated & unsheathed copper wire in 19mm dia Polythene pipe recessed in wall from Nearest LT panel to HTPN DB
Supply and drawing 1.1 KV grade 2x6sq.mm +1x4 sq.mm single core PVC insulated & unsheathed copper wire in 19mm dia Polythene pipe recessed in wall from HTPN to SPN DB
Supply and drawing 1.1 KV grade 2x4 sq.mm +1x1.5sq mm single core PVC insulated & unsheathed copper wire in 19mm dia Polythene pipe recessed in wall.
Supply and drawing 1.1 KV grade 2x2.5sq.mm +1x1.5sqmm single core PVC insulated & unsheathed copper wire in 19mm dia Polythene pipe recessed in wall for PP point & computer Pts.
Supply and drawing 1.1 KV grade 3x1.5sq.mm copper wire in 19mm dia Polythene pipe recessed in wall for separate 2x6A plug points.
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc. including supplying sockets, tapes
a) 4x16 sq.mm + 2x4Sqmm
b) 2x6 sq.mm + 1x4Sqmm
c) 2x4 sq.mm + 1x2.5Sqmm
d) 2x2.5 sq.mm + 1x1.5Sqmm
S&F 415V, 6 Way VTPN DB Double Door incorporated with 1No. 100A 4Pole 25kA DPX3 MCCB as incomer & 6 Nos. 63A TP MCB.(Make- Seimens/L&T/Legrand) as per G.S.
S&F 415 V, Horizontal type, TPN MCB DB ( 4-way) with SS enclosure double-door with IP-42/43 protection with Four Pole Isolators as incomer and SPMCBs ('C' Curve, 10 kA) as outgoing on the surface of the wall with fastners & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment as per GS. INCOMING-63 A FP Isolator -1 No. OUTGOING-32A SPMCB-12 Nos. ( Make :Siemens / Legrand/Havells)
S&F 415 V, Horizontal type, TPN MCB DB ( 6-way) with SS enclosure double-door with IP-42/43 protection with Four Pole Isolators as incomer and SPMCBs ('C' Curve, 10 kA) as outgoing on the surface of the wall with fastners & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment as per GS. INCOMING-63 A FP Isolator -1 No. OUTGOING-32A SPMCB-18 Nos. ( Make :Siemens / Legrand/Havells).
S&F 250 V,( 6-10)A per way, SPN MCBDB (2+12) way with SS enclosure double-door(Ivory White with IP-42/43 protection with DP Isolators as incomer and SPMCBs ('C' Curve, 10kA) as outgoing,on the surface of the wall with fastners & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment as per GS. INCOMING-40A DP Isolator OUTGOING 12 Nos. 6-10A SPMCB ( Make :Siemens / Legrand/Havells ).
Supplying and fixing double-door (2+8) way SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. incl. S&F 250V of 40Amp. DP MCB Isolator-1 no. & 8nos 6-32Amp. SP MCB (Make- Legrand / Siemens/L&T)
Supply and laying 1.1KV Gr. 4/ core 120 Sq. mm. XLPE/PVC Ar.Al. cable surface on the wall along with 2x10 S.W.G. G.I. wire as per G.S. (Make-Gloster/Havells/Polycab) (From DG Panel to CCULT PANEL)
Supply and laying 1.1KV Gr. 4 core 50 Sq. mm. XLPE/PVC Ar.Al. cable surface on the wall along with 2x10 S.W.G. G.I. wire as per G.S. (Make-Gloster/Havells/Polycab) (From LT Panel to VTPN)
S & F compression brass cable gland and sockets with finishing the ends of the following cable by crimping method as per G.S.
3.5 core 50 Sq. mm
4C core 120 Sq. mm.
Supply & Fixing 9" dia exhaust fan (Make-EPC) of following sizes incl. louver shutter after making hole in wall and mending good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection
Dismantling the exiting worn out electrical installation as per direction of E.I.C.
Interconnection :All interconnection between incoming main to busbar are to be made with suitable size electrilytic tinned copper bars or equivalent flexible PVC insulated multistranded single core Cu cable and the same between busbar to each outgoing mains and for metering arrangements are to be made by suitable size of copper with proper socketing of the end of each wire leads . The complete panel board is to be spray painted after required surface treatment by 7 tanks process / sand blasting with 2 coat of red oxide primer & 2 coat of finished paint over dried or powder coating . Installation : The complete panel board is to be installed on suitable brick padestal incl. net cement finish as directed by the E.I.C.
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level By ISI-Medium GI pipe.
SITC of indoor & outdoor unit of High-wall Split Air Conditioner having following specification: Cooling capacity not less than 6400 Watt Minimum ISEER - 3.5, BEE levelling - 2-Star or more Capacity - 2.0 TR IS Compliance - IS-1391 Refrigerant - R410A/R32 Compressor - Rotary/Scroll Evaporator & Condenser Coil - Copper Operating outdoor temperature - 50ºC and above Power supply - 230V, 50Hz (±tolerance as per applicable standard) The scope of work is also includes supply of following: (i) Necessary refrigerant Cu line with nitrile rubber insulatio - 3 Mtr. (ii) Necessary Copper cable (FRLS type, Make - Finolex, Havells/Polycab) - 3 Mtr. [Make: O.General / Mitsubishi Electric / Mitsubishi Heavy Duty]
Supply & Installation of 5/8", 1/2",3/8" & 1/4" copper refrigrant pipes with 9mm thick nitrile rubber insulation, 4Cx2.5 sp.mm. copper cable & best quality PVC drain pipe including fixing arrangement and with wrapping insulation tape complete in all respect for all A.C machines.
S&F angle structure/Pre-fabricated angle with mending works for installation of Split Air Conditioner as directed by EIC.
Supply & Laying 20mm dia heavy type PVC hard pipe by shaddling on wall incl. PVC'T', elbow, bend etc. for drain out the condense water incl. solvent solution & fixing materials.
OUTPUT IN BATTERY RUN (DC- AC) *Voltage variation static:± 1%*Voltage variation n(dynamic 0-100%;100-0%):± 1%*THDv on nominal power ( linear load):< 0.5 %*THDv on nominal power ( not linear load P.F= 0.7):< 1%*Frequency:50 Hz *Current Crest Factor:3: 1 according with IEC C62040 -3*Overload capability : @ unity PF :*10 min:115% load rate with no bypass intervention*60 sec:135% load tare with no bypass intervention*60 sec:135% load tare with no bypass intervention BATTERY *Type:SMF Minimum VAH required for 30 mins. back up:20160 *Charging Cycle:Intelligent with boost charge and advanced management*Battery Make:Quanta / Exide ENVIORNMENTAL SPECIFICATION *Noise level @1m:46 dBA*Working temperature range:from 0˚C to + 40 ˚C*Stock temperature range:from - 20˚C to + 50 ˚C ( Excluded batteries)*Humidity range:20-95% not condensing*Protection Degree:IP 21 MECHANICAL and Miscellaneous *Technology Rectifier/Booster/Inverter:IGBT*Communication Interface:2 serial Port RS 232, SNMP Enable*Input /Output connection:3P + N + PE Connectors on omega bar*Standards:EN 62040-3*Certificates:CE*Remote Monitoring Feature:Available (optional)
SITC of 5 KVA Single phase input & Single phase out put on line UPS systems. Topology, IGBT BASED DSP CONTROLED: Input Voltage: 230 VAC, 160 - 270 VAC Input Frequency: 50 Hz, 47 to 53 Hz nput PF: > 0.99 Output Voltage: 220 VAC +/- 1% Output Frequency: 50 Hz +/- 0.1% in Free running & +/- 4% in Sync Isolation Transformer: Provided Inbuilt (No external tranformer accepted ) Power Factor: 0.8 Lag to Unity Crest Factor: 3:1 Waveform: Sinusoidal THD: < 3% on linear load & < 5% on non-linear load Overload: 110% for 10 minutes, 125% for 1 minutes, 150% for 30 msec Transient Response : For 0 - 50% & 50% - 100% load change voltage remains within +/- 5% Ripple: < 2% Inverter Efficiency: > 93% Battery : 12 V, Mono Block batteries. Battery Back UP: 30 mim back up minimum VAH required 6240 VAH Battery Make: Exide, Amar Raja Quanta Powder coated open battery rack , Protections: Input & Output Over / Under Voltage, Single Phasing DC - High / Under Voltage, Battery Charging Over Current, Output Overload / Short Circuit / Over Temp., UPS auto ON on Mains recovery Audio Alarm, Mains Fail, Battery Low Pre-alarm, Inverter Trip Metering: Digital Seven segment - Voltage, Current & Frequency, Battery - Voltage & Current Indications: Mains - On / Fail / High / Low / Single Phasing DC - On / High, Battery - Low Pre-alarm / Low Trip Inverter - On / Trip / High / Low / Over Current (Make:- Numeric/APC/Emmerson/Switching AVO)
Note: 1) All the above rates should be quoted inclusive of all taxes & duties, District charges, Riverine charges and LWC as applicable 2) Total is rounded off to the nearest rupees.
M/S N. C. HORE
RASH ELECTRICAL WORKS
GHANASHYAM ELECTRIC STORES
SIMPSON AND FERRIS PVT LTD
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .