Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹46.6 LAccepted-AOC GANDHI CHOWK SHIV MANDIR MARG RANIKHET DISTT ALMORA UTTARAKHAND | ₹46.6 L Quoted ₹47.4 L | 1 | Accepted-AOC Being L1 |
| 2 | 2₹50.6 LRejected-Finance NEAR HAIDAKHAN MANDIR VILL PO CHILIYANAULA RANIKHET DISTT ALMORA UTTARAKHAND 263645 | ALMORA | UTTARAKHAND | 263645 | ₹50.6 L | 2 | Rejected-Finance Other than L1 |
| 3 | 3₹50.7 LRejected-Finance FEDRICK VILLA NEAR ELECTRIC POWER HOUSE RANIKHET 263 645 UK | ALMORA | UTTARAKHAND | 263645 | ₹50.7 L | 3 | Rejected-Finance Other than L1 |
| Sl No | Description | Qty | Unit | M/S NAYAL ELECTRICALS L1 | DEEPAK KUMAR BINWAL L3 | SS Construction Co L2 |
|---|---|---|---|---|---|---|
| 1.00 | M & L for opening of DG set 180 KVA / 125 KVA water cooled by unscrewing nuts, bolts and servicing of DG set with checking of oil, coolant, V belt, greasing and oiling of parts and topping up, cleaning the inner body, tank and radiator by removing sludge etc and reassembling the DG set after repair/ replacement of unserviceable minor parts of DG set and testing at Ranikhet & Nagpani complete all as specified and directed.
Make : KIRLOSKAR
(NOTE :- Any major defective part which are required to be replaced to make the DG set functional shall be measured and paid seperately under respective items | 2 | Each Job | 4,500 ₹9,000 | 5,510 ₹11,020 | 5,500 ₹11,000 |
| 2.00 | S & F fuel filter of DG set 180 KVA / 125 KVA complete all as specified and directed. | 4 | Each | 1,678 ₹6,712 | 1,800 ₹7,200 | 1,790 ₹7,160 |
| 3.00 | S & F lube oil filter of DG set 180 KVA / 125 KVA complete all as specified and directed. | 4 | Each | 1,551 ₹6,204 | 1,660 ₹6,640 | 1,650 ₹6,600 |
| 4.00 | S & F air filter of DG set 180 KVA / 125 KVA complete all as specified and directed. | 5 | Each | 3,243 ₹16,215 | 3,460 ₹17,300 | 3,450 ₹17,250 |
| 5.00 | S & F copper washer of DG set 180 KVA / 125 KVA complete all as specified and directed. | 8 | Each | 42 ₹336 | 46 ₹368 | 45 ₹360 |
| 6.00 | S & F banjo bolt of DG set 180 KVA / 125 KVA complete all as specified and directed. | 8 | Each | 55 ₹440 | 60 ₹480 | 59 ₹472 |
| 7.00 | S & F fuel pipe of DG set 180 KVA / 125 KVA complete all as specified and directed. | 5 | Each | 329 ₹1,645 | 351 ₹1,755 | 350 ₹1,750 |
| 8.00 | S & F hose water pipe for radiator of DG set 180 KVA / 125 KVA complete all as specified and directed. | 5 | Each | 230 ₹1,150 | 241 ₹1,205 | 240 ₹1,200 |
| 9.00 | S & F warm drive H / clip of DG set 180 KVA / 125 KVA complete all as specified and directed. | 8 | Each set | 40 ₹320 | 47 ₹376 | 45 ₹360 |
| 10.00 | S & F V – belt of DG set 180 KVA / 125 KVA complete all as specified and directed. | 4 | Each set | 605 ₹2,420 | 652 ₹2,608 | 650 ₹2,600 |
Updated dates
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
26 Dec 2025, 6:00 pmClosed
CWE (HILLS) PITHORAGARH
HQ CWE (HILLS) PITHORAGARH POST OFFICE - BHARKATIA DISTRICT - PITHORAGARH STATE - UTTARAKHAND PIN 262520
CA NO. CWE/HILLS/RKT/108 OF 2025-2026 REPAIRS/MAINTENANCE OF SOLAR WATER HEATING SYSTEM, SOLAR SECURITY LIGHT, DG SETS AND REPAIRS/MAINT OF REFRIGERATION AND AIR CONDITIONING APPLIANCES AT RANIKHET AND CHAUBATTIA UNDER GE RANIKHET
2025_MES_742061_1
89296/25-26/E8
Open Tender
Civil Works
180 days
RANIKHET AND CHAUBATTIA
Class - D
9 documents required · 9 mandatory
₹500
GE (MES) RANIKHET
₹1 L
Yes
5 Mar 2026
28 Nov 2025
2 Jan 2026
28 Nov 2025
26 Dec 2025
12 Dec 2025
Amount
M & L for opening of DG set 180 KVA / 125 KVA water cooled by unscrewing nuts, bolts and servicing of DG set with checking of oil, coolant, V belt, greasing and oiling of parts and topping up, cleaning the inner body, tank and radiator by removing sludge etc and reassembling the DG set after repair/ replacement of unserviceable minor parts of DG set and testing at Ranikhet & Nagpani complete all as specified and directed. Make : KIRLOSKAR (NOTE :- Any major defective part which are required to be replaced to make the DG set functional shall be measured and paid seperately under respective items
S & F fuel filter of DG set 180 KVA / 125 KVA complete all as specified and directed.
S & F lube oil filter of DG set 180 KVA / 125 KVA complete all as specified and directed.
S & F air filter of DG set 180 KVA / 125 KVA complete all as specified and directed.
S & F copper washer of DG set 180 KVA / 125 KVA complete all as specified and directed.
S & F banjo bolt of DG set 180 KVA / 125 KVA complete all as specified and directed.
S & F fuel pipe of DG set 180 KVA / 125 KVA complete all as specified and directed.
S & F hose water pipe for radiator of DG set 180 KVA / 125 KVA complete all as specified and directed.
S & F warm drive H / clip of DG set 180 KVA / 125 KVA complete all as specified and directed.
S & F V – belt of DG set 180 KVA / 125 KVA complete all as specified and directed.
S & F asbestos rope of size 20mm dia on exhaust pipe of DG set 180 KVA complete all as specified and directed.
S & F PVC superior quality coolant side box for 180/125 KVA DG set complete all as specified and directed.
M & L for opening of DG set 45/50/63/62.5 KVA water cooled by unscrewing nuts, bolts and servicing of DG set with checking of oil, coolant, V belt, greasing and oiling of parts and topping up, cleaning the inner body, tank and radiator by removing sludge etc and reassembling the DG set after repair/ replacement of minor unserviceable parts of DG set and testing complete all as specified and directed. Make : KIRLOSKAR (NOTE :- Any major defective part which are required to be replaced to make the DG set functional shall be measured and paid seperately under respective items
S & F fuel filter of DG set 45/50/63/62.5 KVA complete all as specified and directed.
S & F lube oil filter of DG set 45/50/63/62.5 KVA complete all as specified and directed.
S & F air filter of DG set 45/50/63/62.5 KVA complete all as specified and directed.
S & F copper washer of DG set 45/50/63/62.5 KVA complete all as specified and directed.
S & F banjo bolt of DG set 45/50/63/62.5 KVA complete all as specified and directed.
S & F fuel pipe of DG set 45/50/63/62.5 KVA complete all as specified and directed.
S & F hose water pipe for radiator of DG set 45/50/6362.5 KVA complete all as specified and directed.
S & F warm drive H / clip of DG set 45/50/63/62.5 KVA complete all as specified and directed.
S & F V – belt of DG set 45/50/63/62.5 KVA complete all as specified and directed.
S & F fuel pump for 45/50/63 KVA DG as per sample complete all as specified and directed.
M & L for opening of DG set 15 KVA water cooled by unscrewing nuts, bolts and servicing of DG set with checking of oil, coolant, V belt, greasing and oiling of parts and topping up, cleaning the inner body, tank and radiator by removing sludge etc and reassembling the DG set after repair/ replacement of minor unserviceable parts of DG set and testing complete all as specified and directed. Make :- KIRLOSKAR (NOTE :- Any major defective part which are required to be replaced to make the DG set functional shall be measured and paid seperately under respective items
S & F fuel filter of DG set 15 KVA complete all as specified and directed.
S & F lube oil filter of DG set 15 KVA complete all as specified and directed.
S & F air filter of DG set 15 KVA complete all as specified and directed.
S & F copper washer of DG set 15 KVA complete all as specified and directed.
S & F banjo bolt of DG set 15 KVA complete all as specified and directed.
S & F hose water pipe for radiator of DG set 15 KVA complete all as specified and directed.
S & F warm drive H / clip of DG set 15 KVA complete all as specified and directed.
S & F V – belt of DG set 15 KVA complete all as specified and directed.
M & L for opening of DG set 7.5/10 KVA water cooled by unscrewing nuts, bolts and servicing of DG set with checking of oil, coolant, V belt, greasing and oiling of parts and topping up, cleaning the inner body, tank and radiator by removing sludge etc and reassembling the DG set after repair/ replacement of minor unserviceable parts of DG set and testing complete all as specified and directed. Make :- KIRLOSKAR (NOTE :- Any major defective part which are required to be replaced to make the DG set functional shall be measured and paid seperately under respective items
S & F fuel filter of DG set 7.5 /10KVA complete all as specified and directed.
S & F lube oil filter of DG set 7.5/10 KVA complete all as specified and directed.
S & F air filter of DG set 7.5 /10KVA complete all as specified and directed.
S & F copper washer of DG set 7.5/10 KVA complete all as specified and directed.
S & F banjo bolt of DG set 7.5/10 KVA complete all as specified and directed.
S & F hose water pipe for radiator of DG set 7.5/10 KVA complete all as specified and directed.
S & F warm drive H / clip of DG set 7.5/10 KVA complete all as specified and directed.
S & F V – belt of DG set 7.5/10 KVA complete all as specified and directed.
Supply & filling coolant complete , Make : Servo / CRB Plus complete all as specified and directed.
Supply & filling distilled water complete all as specified and directed.
Supply & filling engine oil of recommended grade 15W40, Make: Servo / CRB Plus/HP complete all as specified and directed.
S & F in replacement lead acid battery 12 Volt 150 AH for DG set, including taking out old unserviceable battery complete all as specified and directed.
S & F in replacement lead acid battery 12 Volt 180 AH for DG set, including taking out old unserviceable battery complete all as specified and directed.
S & F in replacement battery terminal brass complete with GI nuts & bolts including taking out old unserviceable battery terminal brass complete all as specified and directed.
S & F in replacement battery lead wire as per existing size and length, flexible copper conductor single core including taking out old unserviceable battery lead wire complete all as specified and directed.
Repair to self starter assembly of DG set of cap 45/50/63/62.5 KVA by cutting of old burnt winding wire and winding with new copper winding wire as per existing size / gauge including insulation materials, varnishing, heating / drying up etc complete all as specified and directed.
Repair to self starter assembly of DG set of cap 15/10/7.5 KVA by cutting of old burnt winding wire and winding with new copper winding wire as per existing size / gauge including insulation materials, varnishing, heating / drying up etc complete all as specified and directed.
Supply and fix in replacement self starter assembly complete of DG set of cap 45/50/63 KVA by taking out of old burnt self starter as per existing size / gauge etc complete all as specified and directed.
Supply and fix in replacement rotary hand pump for lifing of fuel from barrel to DG set tank with PVC pipe of size 20 mm dia sureior quality of lenght ten mtr complete all as specified and directed.
M&L for repair of DG Set 180/125 KVA Opening of cylinder head, FIP, self start assy, cleaning all the parts of engine and chamber by Kerosene oil, removing connecting rod,crank shaft, removing all the piston rings from piston and replacing of piston ring, connecting rod bush of all piston of existing size and shape replacing all engine valve, replacing cylinder head, over hauling of caliber of FIP as per required including the nozzel, replacing all the gasket including cylinder head gasketas required, of generator set 63 KVA cleaning , checking and adjusting of aneroid oil, throttle linkage, fuel tank breather, crankcase breather, air piping, oil bath air cleaner tray screen and belt including replacing of engine oil, full flow oil fillter , by pass filter air compressor breather element, fuel filter primary and secondary etc all as specified and directed by the Engr-in-charge.
M&L for repair of DG Set of cap upto 62.5/63 KVA Opening of cylinder head, FIP, self start assy, cleaning all the parts of engine and chamber by Kerosene oil, removing connecting rod,crank shaft, removing all the piston rings from piston and replacing of piston ring, connecting rod bush of all piston of existing size and shape replacing all engine valve, replacing cylinder head, over hauling of caliber of FIP as per required including the nozzel, replacing all the gasket including cylinder head gasketas required, of generator set 63 KVA cleaning , checking and adjusting of aneroid oil, throttle linkage, fuel tank breather, crankcase breather, air piping, oil bath air cleaner tray screen and belt including replacing of engine oil, full flow oil fillter , by pass filter air compressor breather element, fuel filter primary and secondary etc all as specified and directed by the Engr-in-charge.
S & F in repairs of control panel inside DG set of 45/50/63 KVA, replacement of us MCBs, indicators, start stop buttons, sensors, wiring with suitable size cable and checking entire circuit complete all as specified and directed.
M&L for earthing complete with galvanised steel, earth plate electrode 600x600mm x 6mm thick burried directly in ground verticaly (earth pit not less than 2.25 mtrs below ground level ) with top edge of the plate not less than 1.5 mtrs below normal ground level connected to galvanised strip 32x6mm as earth lead by means of bolts, nuts, check nuts and washers of galvanised iron/steel all as shown in electrical plate No 3 on page 497 of MES schedule 2009 part - I connected to main switch board/main DBs/earthing test point including all necessary excavation and earth work in hard/dense soil common salt and charcoal dust mixed and packed 150mm thick all round the GI earth plate, watering pipe 20mm dia GI medium grade. GI sheet 0.63 mm thick funnel, wire gauge, 50mm thick RCC cover in PCC 1:2:4 type B1 duly reinforced with MS round bars 6mm dia @ 150c/c both ways and pit/chamber in PCC 1:3:6 type C1 with suitable lifting handle to cover, GI protection pipe 15mm dia light grade up to 7.5mtr from electrode GI pipe to be fixed with complete all as specified and directed. Note :- (i) Earth lead beyond 7.5 mtr from electrode to earth terminal point/main switch & GI pipe light grade 15mm dia for protection against mechanical damage to lead shall be measured separately. (ii) On testing after completion if desired earth resistance is not obtained, the earthing will be redone at no extra cost.
Supply and fix in replacement aluminium lugs of size 300 mm sqmm complete all as specifide and directed .
Supply and fix in replacement aluminium lugs of size 240 mm sqmm complete all as specifide and directed .
Supply and fix in replacement aluminium lugs of size 185 mm sqmm complete all as specifide and directed .
Supply and fix in replacement aluminium lugs of size 150 mm sqmm complete all as specifide and directed .
Supply and fix in replacement aluminium lugs of size 95 mm sqmm complete all as specifide and directed .
Supply and fix in replacement changeover switch AC 23 side handle 4 pole , 415 Volt 63 AMP complete all as specifide and directed .
Supply and fix in replacement changeover switch AC 23 side handle 4 pole , 415 Volt 100 AMP complete all as specifide and directed .
Supply and fix in replacement changeover switch AC 21 side handle 4 pole , 415 Volt 200 AMP complete all as specifide and directed .
Supply and fix in replacement changeover switch AC 21 side handle 4 pole , 415 Volt 320 AMP complete all as specifide and directed .
Replacement of MCCB of Cap 100 Amp, 4pole, 25KA, with adjustable thermal release and earth fault protection, 415 volt grade including cutting and welding work for fixing of MCCB in existing panels any type and model.
All as per item No.66 but Cap 200 Amp, 36 KA.
All as per item No.66 but Cap 250 Amp, 36 KA.
All as per item No.66 but Cap 350 Amp, 36 KA
Supply, laying, jointing and commissioning in replacement LT XLPE 1100 volts grade heavy duty cable, stranded aluminium conductor served with inner sheathing of PVC tape, armoured with GI steel or tape and over all PVC sheathing laid in trenches, floor through pipes,induct, on pole and roads etc of following sizes :-
(a) 120 Sqmm 3.5 core
(b) 95 Sqmm 3.5 core
(c) 70 Sqmm 3.5 core
(d) 50 Sqmm 3.5 core
(e) 35 Sqmm 3.5 core
Excavation in trenches in hard/dense soil not exc 1.5 mtrs wide and not exc 1.5 m in depth for laying cables and getting out incl jointing bottom surface to the reqd level/slope etc complete all as specified and directed.
Returning filling in incl spreading, leveling, watering and well ramming in layers not exc 25 cm in hard/dense soil all as specified and directed.
Removing excavated material to a distance not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point.
M&L for laying of fine river sand, free from sharp material for cable cushioning in trenches all as specified and directed.
M&L for brick protection covers laid over cables of sub class'B' bricks old size (230X115X75)mm all as specified and directed.
M&L in replacement for GI pipe light grade with all fittings fixed to pole and laid to floor/ground for mechanical protection of cable of the following sizes :-
(a) 80mm bore
(b) 50mm bore
Supply and fixing ignition transformer for the oil fired chamber as per sample, incoming voltage 230 volts and outgoing voltage 14500 volts installed at MH Ranikhet complete all as specified and directed.
.Supply and fixing Solenoid valve as per Cat part No. 8510113200 for oil fired incinerator of Make Thermex, capacity 50 Kg / hours installed at MH Ranikhet complete all as specified and directed.
Supply and fixing Burner nozzle 2.5 GPH 80 degree PY - 75/100 as per Cat part No. 8904111400 for oil fired incinerator of Make Thermex, capacity 50 Kg / hours installed at MH Ranikhet complete all as specified and directed.
Supply and fixing Diffuser plate assembly for MI as per Cat part No. 1061602630 for oil fired incinerator of Make Thermex, capacity 50 Kg / hours installed at MH Ranikhet complete all as specified and directed.
Supply and fixing Photo cell type - 8205 as per Cat part No. 8603111400 for oil fired incinerator of Make Thermex, capacity 50 Kg / hours installed at MH Ranikhet complete all as specified and directed.
Supply and fixing Pressure gauge Cat 0 - 40 Kg/cm 1/2 BSP as per Cat part No. 8451114100 for oil fired incinerator of Make Thermex, capacity 50 Kg / hours installed at MH Ranikhet complete all as specified and directed.
Supply and fixing Metalic hose 40 Kg / cm as per Cat part No. 8911104000 for oil fired incinerator of Make Thermex, capacity 50 Kg / hours installed at MH Ranikhet complete all as specified and directed.
Supply and fixing electrode` for oil fired incinerator of Make Thermex, capacity 50 Kg / hours installed at MH Ranikhet complete all as specified and directed.
Supply and fixing glass wool for oil fired incinerator of Make Thermex, capacity 50 Kg / hours installed at MH Ranikhet complete all as specified and directed.
Supply and fixing filter assembly for oil fired incinerator of Make Thermex, capacity 50 Kg / hours installed at MH Ranikhet complete all as specified and directed.
M & L for complete overhauling and servicing of existing hot blower plant at MH Ranikhet comprising of (a) centrifugal air handling unit (blower). (b) one HP motor with starter (c) Strip heaters 6 Nos (d) Switch board with voltmeter and ammeter complete incl replacement of defective parts to make the complete plant serviceable and cleaning and greasing of mechanical parts and testing after servicing in presence of Engineer in charge all as specified and directed.
Supply and fix in repair the chimney top mounted indication/signal lamp with red light for emergency signal as per existing size and complete testing after installation all as specified and directed by Engineer in charge.
S & F in repair water tubing medium grade galvanised with all GI fittings (such as bend,elbows,tees, connections, short pieces, back, nuts, unions, caps & plugs, reducer etc) of size 20 mm laid in trenches or fixed on walls or on open surfaces complete all as specified and directed.
M & L for complete cleaning of sludge collection chamber/reservoir of incinerator incl cleaning of inlet and outlet and treatment with chemical on base to make the sludge flow obstruction free and painting the reservoir/chamber all as directed and specified by Engineer-in-charge.
M/L for complete removal of existing treatment for preparing old painted surfacess and applying two coat of distemper oil emulsion over a coat of primer complete all as specified and directed.
M/L for complete removal of existing treatment for preparing old painted surfacess and applying two coat of cement base paint over a coat of primer complete all as specified and directed.
M&L for rendering 15 mm thick faces of brick work or stone masonry or concrete surfaces in cement mortar 1:4 and finished fair and even without using extra cement complete all as specified.
M&L for preparing new plastered or unplastered surfaces of walls and applying two coats of cement base paint over a coate primer complete all as specified and directed.
(a) Comprehensive maintenance and operation of entire metering system for smooth and troublefree operation of vending station of prepaid meters to be carried by OEM or by the authorized rep of OEM incl repairing (Except damage from fire,water) of defective part of electric 3 Phase 4 Wire and 1 Phase 2 Wire prepaid Energy Meters,current range 05-60 Amp,415 V or 240 V,accuracy class 1.0 along with parallel home display split unit.Make-Secure Qty-1210 Nos (b) Maintenance of entire metering system including renewal of vending charges. Providing round the clock server backup (incl sundays and holidays ) including carrying out and furnishing all meter related reports and revenue reports all as directed by GE / Engineer-in-Charge as per Indian electricity rule / engineering practices and maintaining all the meter details and records , break down details, or providing any other reports or data pertaining to prepaid meter at the station as required by of GE/ Engineer-in-Charge Note : Maintenance and operation for 11 months will be applied from the date of acceptance of work.
(c) All work shall be done by OEM/OEM authorized vendor (M/s Secure Meters Ltd).The contractor shall produce an MoU with the OEM before commencement of work, for round the clock technical support from OEM, all the necessary & latest upadtes in the existing software/software license and timely addressal of all complaints from the OEM within 24 hours of registering the complaints, failing which Rs 500 per day will be deducted from the RAR/bill of the contractor after 24 hours for each passing day. (d) The documentary proof of renewal of vending charges from OEM, all complaints registered and addressed, shall be produced by the contractor before processing of RAR/bill. (e) There must not be any kind of service failure or software/server failure in the system from the OEM which can interrupt the smooth working of prepaid metering system otherwise alternate arrangements in such cases shall be made by the OEM (f) The contractor/bidder shall produce the system generated details of all the prepaid meters installed and operated through the existing vending station and software in the station for each month which shall further be used as the base for claiming the RAR/bill Please note the RAR/Bill shall be paid based on the actual numbers of meters as generated by the system for the particular month. (g)All the charges for T&P like paper, printer cartridge, or any other item required for running of vending station shall be borne by the contractor only. (h) No extra charges will be paid by the department and nothing shall be claimed by the contractor/bidder regarding any of the above clauses.
Taking up or down 15 mm bore steel water tubing and connection complete all as specified and directed.
Taking up or down 20 mm bore steel water tubing and connection complete all as specified and directed.
Taking up or down 25 mm bore steel water tubing and connection complete all as specified and directed.
M&L in replacement Pipes galvanised medium class of size 15 mm dia laid in trenches, wall or floor .
M&L in replacement Pipes galvanised medium class of size 20 mm dia laid in trenches ,wall or floor .
M&L in replacement Pipes galvanised medium class of size 25 mm dia laid in trenches ,wall or floor .
Refixing of old GI pipe size 15 mm dia with all new fitting all as specified and directed.
Refixing of old GI pipe size 20 mm dia with all new fitting all as specified and directed.
Refixing of old GI pipe size 25 mm dia with all new fitting all as specified and directed.
Supply, fixing , testing & commissioning in replacement of solar collector as per existing size (appx size 1 m x 2 m ) complete all as specified and directed.
Supply, fixing , testing & commissioning in replacement of solar collector as per existing size (appx size 1.2 m x 1.8 m )complete all as specified and directed.
Supply, fixing , testing & commissioning in replacement of toughened U.V Glass and as per existing size of glass (appx size 1 m x 2 m ) with minimum 3 mm thickness for collector complete all as specified and directed.
Supply, fixing , testing & commissioning in replacement of toughened U.V Glass and as per existing size of glass (appx size 1.2 m x 1.8 m ) with minimum 3 mm thickness for collector complete all as specified and directed.
M & L for Descaling of solar water heater collector using very mild mineral acid to clear the deposites of temporary hardness in side of collector tubes including brazing of leaking joint as required at site complete all as specified and directed. (Note : The quoted shall include the cost of cutting & refixing of monkey caging as required at site)
Supply and fixing rubber washer complete all as specified and directed.
Supply, fixing , testing & commissioning of insulation materials for hot / cold water pipe any size and size of insulation on pipe 5 cm thick glass wool / mineral wool with chicken mesh and Aluminium cladding 26 swg complete all as specified and directed.
M &L for descaling of heat exchanger in side of hot water tank and hot water tank after repair , testing of hot water tanks capcity 1500 /1000 ltrs including replacement cold water pipe/ hot water pipe complete all as specified and directed. (Note : The quoted shall include the cost of cutting & refixing of monkey caging as required at site)
M &L for descaling of heat exchanger in side of hot water tank and hot water tank after repair , testing of hot water tanks capcity 200/500 ltrs including replacement cold water pipe/ hot water pipe complete all as specified and directed. (Note : The quoted shall include the cost of cutting & refixing of monkey caging as required at site)
Material and labour for Gas welding of leaking joint in the flat panel collector complete all as specified and directed.
Supply and fix in replacement heating element 2 KW complete all as all as specified and directed.
Supply and fix in replacement thermostate for heating element 2 KW complete all as all as specified and directed.
M & L in replacement for sub main wiring with 1100 volt grade two single core PVC insulated and unsheathed cable with stranded copper conductor 6 sqmm drawn into and including electrical grade PVC conduit not less than 25 mm dia with IS 9537 (Part-III) 1983 mark, or relevant ISI mark with all accessories fixed concealed including chase cutting in brick/ stone masonry for fixing conduit and making good the disturb surfaces of wall as per existing including 4 sqmm multi - stranded copper conductor as earth wire in green colour complete all as specified and directed.
Supply and fix in replacement PVC tank rotational moulded water storage tank of capacity 1000 ltrs including float valve(cylindrical vertiacal with closed top) hoisted and fixed in position all as specified in SSR part-I.
Supply and fix in replacement PVC tank rotational moulded water storage tank of capacity 500 ltrs including float valve(cylindrical vertiacal with closed top) hoisted and fixed in position all as specified in SSR part-I.
Supply and fix in replacement ball brass valve high pressure with screwed for iron pipe of size 25 mm complete all as specified and directed .
Supply and fix in replacement ball brass valve high pressure with screwed for iron pipe of size 20 mm complete all as specified and directed .
Taking out old unserviceable gun metal, globe or gate valve including S & F gun metal, globe or gate valves ISI marked class-I, with iron wheel head, screwed both ends, for iron pipe of size 25 mm complete all as specified and directed
Taking out old unserviceable gun metal, globe or gate valve including S & F gun metal, globe or gate valves ISI marked class-I, with iron wheel head, screwed both ends, for iron pipe of size 20mm complete all as specified and directed
Taking out old unserviceable gun metal, globe or gate valve including S & F gun metal, globe or gate valves ISI marked class-I, with iron wheel head, screwed both ends, for iron pipe of size 15mm complete all as specified and directed.
M&L for insulation of hot water tank of cap 1000/1500 ltrs with thickness of insulation 10 CM around the tank and aluminium sheet of size 24 SWG complete all as specified and directed. (Note : The quoted shall include the cost of cutting & refixing of monkey caging as required at site)
M&L for insulation of hot water tank of cap 200/500 ltrs with thick ness of insulation 10 CM around the tank and aluminium sheet of size 24 SWG complete all as specifide and directed . (Note : The quoted shall include the cost of cutting & refixing of monkey caging as required at site)
S & F in replacement hot water tank of cap 1000/1500 ltrs with thickness of insulation 10 CM around the tank and aluminium sheet of size 24 SWG all as per existing sample including make up tank & connection with existing pipelines complete all as specified and directed. (Note : The quoted shall include the cost of cutting & refixing of monkey caging as required at site)
S & F in replacement hot water tank of cap 200 ltrs with thickness of insulation 10 CM around the tank and aluminium sheet of size 24 SWG all as per existing sample including make up tank & connection with existing pipelines complete all as specified and directed. (Note : The quoted shall include the cost of cutting & refixing of monkey caging as required at site)
M & L in replacement for connecting and testing of CI air release valve 20 mm size with ISI marked flanged type incl jointing material such as fiber board, nut bolt, washers, and welding etc complete all as specified and directed.
M & L in replacement for connecting and testing of CI air release valve 15 mm size with ISI marked flanged type incl jointing material such as fiber board, nut bolt, washers, and welding etc complete all as specified and directed.
S & F in replacement sheet metal enclosure for DB’s (Double door type) when MCB’s to be used, single pole and neutral, 8 ways with 200 ampere rated bus bar, 240 volts fixed sunk / flush to the wall or niche complete all as specified and directed.
S & F in repair MCB single pole, 240 volts, 5 to 32 Ampere, rupturing capacity 10 KA, ‘B’ curve type in the MCB DB including taking down complete all as specified and directed.
S & F in repair MCB single pole and neutral, 240 volts, 32 Ampere, rupturing capacity 10 KA, including taking down complete all as specified and directed.
Supplying and fix in replacement 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including4mm suspension wire, one twin core cable flat or circular of size 10 Sqmm stranded conductor.
M& L for expanded metal weight not exc. 4 Kg/sqm, cut to length, bend to shape as required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised steel staples and fixed complete to wood or steel members complete all as specified and directed by Engr-in -charge
S & F mild steel framed work such as grills, gratings etc with ends of bars soldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks, mokey caging, and similar work con- forming to Fe.290.Gde-E-165complete all as specified and directed
M& L for two coats of synthetic enamel paint over and including one coat of red oxide primer including preparation of old surface complete all as specified and directed by Engr-in -charge
M&L for complete cleaning and descaling of heat exchanger installed at Swimming pool using very mild mineral acid including complete opening and reassembling the same and testing for its proper functioning as per satisfaction of Engr-in charge
Supply & Fixing in replacement LED solar street light fitting 24 watt specified to be increased battery backup 2/3 days ,including galvanised steel pole in built,Pole length minimum 5.5 mtr, lithium ion battery, solar panel, charge controller with dusk down sensor and testing after installation all as specified and directed.
PCC 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) as in foundation filling & mass concrete including use of form work and finishing all exposed faces of concrete complete all as specified and directed by Engineer-in-Charge
Excavation in trenches not exceeding 1.5 Mtr wide and not Exceding 1.5 Mtr in depth and getting out in hard/dense soil for laying cables and pole complete all as specified and directed by Engineer-in-Charge
Supply & Fix in replacement LED street light fitting 60 W pressure die cast aluminium IP66 roadway luminaire with high power LED as light source and electronic driver including GI bracket light grade 25/32/40 mm and provn of electric supply to fitting from junction box by means of PVC Sheathed multi-stranded aluminium conductor cable of 2.5sqmm for phase and neutral & 1.5 sqmm as earth wire complete all as specified and directed incl taking down old unsv light fittings
Supply & Fixing LED Flood light fitting 150 W 230 V AC outdoor type pressure die cast aluminium IP66 luminaire with high power LED as light source and electronic drive with impact and corrosion resisant including clamp and GI bracket light grade and provn of electric supply to fitting from source by means of PVC Sheathed multi-stranded aluminium conductor cable of 2 x 4 sqmm core complete all as specified and directed .
Supply & Fixing LED street light fitting 45 W pressure die cast aluminium IP66 roadway luminaire with operating range from 80V AC to 230 V AC with high power LED as light source and electronic driver including GI bracket light grade 25/32/40 mm and provn of electric supply to fitting from source by means of PVC Sheathed multi-stranded aluminium conductor cable of 3 x 2.5 sqmm core complete all as specified and directed.
S & F LED solar pillar light /gate light with built in solar panel, LED light and lithium battery with charge controller complete with all accessories including PCC work (1:3:6 ) for fixing the light fitting complete all as specified and directed. NOTE: The contractor must submit 5 years warranty for LED fitiings.
Taking down old defective Solar light capacity 12W to 36W for repair and refixing it on Pole incl any other items/accessories as required on site to make the light fitting serviceable complete all as specified and directed
Overhauling & servicing of Refrigerator of capacity upto 230 Ltr and of make Godrej/samsung/Kalvinator or any other make by carrying out the following works at different location of different establishment complete all as specified and directed by Engineer-in-charge (a) Inspection, taking down opening & dismantling descaling brushing cleaning of refrigerator (b) Check and correct earth continuity of electrical items (c) Check thermostate and test its functioning (d) Check & correct all electrical wiring and its functioning (e) Testing of Refrigerator after repairs (f) Replacing defective spare parts (g) Refilling of refrigerant gas to Refrigerator up to required level after detecting & arresting the leakage .
Petty repair complaints for Refrigerator of any capacity and make installing in site of Ranikhet & chaubattia and rectifying the complaints from 0900 hrs to 1700 hrs incl Sunday & Holidays complete all as specified and as directed by Engineer-in-charge. NOTE : ANY DEFECTIVE PART WHICH ARE REQUIRED TO BE REPLACED TO MAKE FUNCTIONAL REFRIGRATOR SHALL BE MEASURED AND PAID SEPERATELY UNDER RESPECTIVE ITEMS
Supply only in replacement to unserviceable Vegetable tray as per existing make & capacity
Supply only in replacement to unserviceable Thermostate switch as per existing make & capacity
Supply only in replacement to unserviceable Starting relay as per existing make & capacity
Supply only in replacement to unserviceable electronic timer unit as per existing make & capacity
Supply only in replacement to fused Bulb as per existing
Supply only in replacement to unserviceable capillary & filter as per existing
Supply only in replacement to unserviceable Freezer tray as per existing
S&F in replacment of condesnor coil of refrigerator as per existing incl brazing of all associated pipe lines complete all as specified and directed by Engineer-in-charge
S&F in replacement new compressor for refrigerator of capacity 165 to 320 ltrs as per existing make & model including brazing work pressure testing dehydration and depositing the original voucher & manufacturer warranty certifcate complete all as specified and directed by Engineer-in-charge
S&F in replacement of unserviceable fan unit of refrigerator and providing electrical connection as per existing make & model complete all as specified and directed by Engineer-in-charge
S&F in replacement of unserviceable PCB circuit of AC complete all as specified and directed by Engineer-in-charge
S&F in replacement of unserviceable Vegitable tray for Refrigerator complete all as specified and directed by Engineer-in-charge
S&F in replacement of unserviceable freezer Cabinet for Refrigerator complete all as specified and directed by Engineer-in-charge
Overhauling and servicing of split type AC of capacity 1.5/2.0 TR of make Bluestar /carrier/voltas or any other make by authorised service agency at different locations of different establishment testing the unit complete with the following :- (a) Overhauling & servicing (b) Inspection opening washing the condensor coil and cooling coil with chemical followed with water complete (c) Inspection of leakage of refrigerant in the system (d) Checking the operation of blower motor condesnor motor for noise free operations (e) Oiling of condensor / blower motors and checking the earth continuity (f) Inspection all electrical parts / connections and remove if any defect (g) Checking the functional of electronic remote control complete all as specified and as directed by Engineer-in-charge.
Petty repairs complaints for split type AC of capacity 1.5 / 2.0 TR, rectifying the defects and making machine satisfactory functional. NOTE : ANY DEFECTIVE PART WHICH ARE REQUIRED TO BE REPLACED TO MAKE FUNCTIONAL SPLIT TYPE ACs SHALL BE MEASURED AND PAID SEPERATELY UNDER RESPECTIVE ITEMS
Supply only in replacement to unserviceable starting relay of Split type in lieu of providing new starting relay all as per existing.
Supply only in replacement to unserviceable starting capacitor 120-150 mfd
Supply only in replacement to unserviceable starting capacitor 100-120 mfd
Supply only in replacement to unserviceable contactor as per existing
Supply only in replacement to unserviceable propeller fan for split type AC of capacity 1.5 / 2.0 TR as per existing all as specified and directed by Engineer-in-charge
Supply only in replacement to unserviceable but new condensor fan motor of any type of split type ACs of capacity 1.5 /2.0 TR
Supply only in replacement to unserviceable blower motor for split type AC 1.5 / 2.0 TR as per existing
Supply only in replacement to unserviceable blower for split type AC 1.5 / 2.0 TR as per existing
Supply only in replacement to unserviceable 3 core flexible copper cable of size 70/.0076 complete all as specified and as directed by Engineer-in-charge
Supply only in replacement to unserviceable 3 core flexible copper cable of size 80/.0020 complete all as specified and as directed by Engineer-in-charge
S&F in replacement new compressor for split type AC of capacity 1.5 TR as per existing including brazing work extra copper tubing pressure testing dehydration & depositing the original voucher & manufacturer warranty certifcate complete all as specified and directed by Engineer-in-charge
M&L rewinding of condensor fan motor for split type AC including replacement of gun metal bushes testing complete all as specified and as directed by Engineer-in-charge
M&L rewinding of blower motor for split type AC including replacement of gun metal bushes testing complete all as specified and as directed by Engineer-in-charge
M&L for Gas charging R-22/R-410/407/410 at site as per requirement of ACs any capacity including removal and replacement copper tubing of required size of liquid filter, capillary including testing on full load for summer season and all as directed:-
S&F in repair sheet metal enclosure single pole and neutral with a two pin and earth plug and socket complete with one single pole MCB 240 Volts 20 Amps modular socket complete all as specified and directed.
Overhauling & servicing of Deep freezers of capacity upto 345 Ltr and of make Haier/Voltas/Bluestar or any other make by carrying out the following works at different location of different establishment complete all as specified and directed by Engineer-in-charge (a) Inspection, taking down opening & dismantling descaling brushing cleaning of deep freezer (b) Check and correct earth continuity of electrical items (c) Check thermostate and test its functioning (d) Check & correct all electrical wiring and its functioning (e) Testing of deep freezer after repairs (f) Replacing defective spare parts
S&F in replacement new compressor for deep freezer of capacity 345/320 ltr as per existing including brazing work extra copper tubing pressure testing dehydration depositing the original voucher & manufacturer warranty certifcate complete all as specified and directed by Engineer-in-charge
S&F in replacment door latch assembly, door seal, handle flange and gasket of deep freezer as per existing incl other minor repair work complete all as specified and directed by Engineer-in-charge
Supply and fix in repair Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4 KVA
Supply and fix in replacement unserviceable basket/tray of deep freezer as per existing size all as specified and directed
S&F the refrigerant gas for deep freezer up to required level after detecting & repairing leakage & making the system leak proof and testing complete all as specified and directed by Engineer-in-charge
Supply & Fix in replacement to unserviceable Thermostate for deep freezer as per existing make & capacity
Supplying and fixing in replacement 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including4mm suspension wire, one twin core cable flat or circular of size 16 Sqmm stranded conductor.
S & F sheet metal enclosure for DB’s (Double door type) when MCB’s to be used, single pole and neutral, 4 ways with 200 ampere rated bus bar, 240 volts fixed sunk / flush to the wall or niche complete all as specified and directed.
S & F in repair MCB single pole, 240 volts, 5 to 32 Ampere, rupturing capacity 10 KA, ‘B’ curve type in the MCB DB including taking down complete all as specified and directed.
S & F in repair MCB single pole and neutral, 240 volts, 32 Ampere, rupturing capacity 10 KA, including taking down complete all as specified and directed.
S & F in repairs Plug top 3 pin 15 amp, complete all as specified and directed
M&L for earthing complete with galvanised steel, earth plate electrode 600x600mm x 6mm thick burried directly in ground verticaly (earth pit not less than 2.25 mtrs below ground level ) with top edge of the plate not less than 1.5 mtrs below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron/steel all as shown in electrical plate No 3 on page 497 of MES schedule 2009 part - I connected to main switch board/main DBs/earthing test point including all necessary excavation and earth work in hard/dense soil common salt and charcoal dust mixed and packed 150mm thick all round the GI earth plate, watering pipe 20mm dia GI medium grade. GI sheet 0.63 mm thick funnel, wire gauge, 50mm thick RCC cover in PCC 1:2:4 type B1 duly reinforced with MS round bars 6mm dia @ 150c/c both ways and pit/chamber in PCC 1:3:6 type C1 with suitable lifting handle to cover, GI protection pipe 15mm dia light grade up to 7.5mtr from electrode GI pipe to be fixed with complete all as specified and directed. Note :- (i) Earth lead beyond 7.5 mtr from electrode to earth terminal point/main switch & GI pipe light grade 15mm dia for protection against mechanical damage to lead shall be measured separately. (ii) On testing after completion if desired earth resistance is not obtained, the earthing will be redone at no extra cost.
M & L for sub main wiring with 1100 volt grade two single core PVC insulated and unsheathed cable with stranded copper conductor 6 sqmm drawn into and including electrical grade PVC conduit not less than 25 mm dia with IS 9537 (Part-III) 1983 mark, or relevant ISI mark with all accessories fixed concealed including chase cutting in brick/ stone masonry for fixing conduit and making good the disturb surfaces of wall as per existing including 6 sqmm multi - stranded copper conductor as earth wire in green colour complete all as specified and directed.
SS Construction Co (BID ID -3502217)
DEEPAK KUMAR BINWAL (BID ID -3501720)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.26 MB
PS108.pdf
Tender Documents • 2.29 MB
BOQ_830953.xls
BOQ • 0.42 MB
Download all tender documents and submit your bid