Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34,795Accepted-Finance ANGANWADI NO 33 SUBHASH NAGAR 37 ELENJIMOODER 30 42 MUBBELNADA AVALAULAN 34 SCOORYA NAGAR 22 KODALBONA VENDULALBEIBOUARO ANGANWADI POWDIKOUAM WARD PROJECT NO 612 25 | KANGPOKPI | MANIPUR | 795002 | L1 | Accepted-Finance L1 | |
| 2 | L2₹42,355+₹7,560 (21.7%)Rejected-Finance KRISHNAKRIPA KOTTARAKARA | L2 | Rejected-Finance L2 |
| Sl No | Description | Qty | Unit | K K Associates L2 | HARIKRISHNAN G L1 |
|---|---|---|---|---|---|
| 1.00Electrification | |||||
| 1.00 | 90.2.1.1:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single Control light point with 6A, plate ceiling rose - Short point | 2 | point | 1,300 ₹2,600 | 1,000 ₹2,000 Lowest |
| 1.00 | 90.2.1.4:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single control ceiling fan point with 6 A, 3 plate ceiling rose & with socket size stepped electronic regulator. - Short point | 1 | point | 1,750 ₹1,750 | 1,400 ₹1,400 Lowest |
| 1.00 | 90.2.1.3:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single control light point without ceiling rose - Short point | 3 | point | 1,250 ₹3,750 | 900 ₹2,700 Lowest |
| 1.00 | 90.2.1.6:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Combined plug point with 6 A, 5 pin plug socket controlled by 6 A, switch in the same switch board as that of light points | 1 | each | 450 ₹450 Lowest | 500 ₹500 |
| 1.00 | 90.4.1:Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required. | 1 | each | 170 ₹170 Lowest | 200 ₹200 |
| 1.01 | 90.3.17.1:Supply, conveyance and erection of the following sizes of 'B' class GI pipe in single section for post top lantern of all types on concrete base (excluding charges for concrete base and excavation) and painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer etc. as required.32 mm dia GI pipe | 1 | metre | 150 ₹150 Lowest | 500 ₹500 |
| 1.01 | OD45900/2025-2026:Supply and fixing angle / straight brass lined skirt type, bakelite batten holder with shade with LED lamp and giving connection etc as required | 3 | each | 250 ₹750 Lowest | 300 ₹900 |
| 1.01 | OD45904/2025-2026:Supply, conveyance, installation, testing and commissioning of ceiling fans of 1200mm sizes using standard accessories excluding resistance type regulator, wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended original wiring etc. as required. | 1 | each | 2,200 ₹2,200 Lowest | 2,200 ₹2,200 Lowest |
| 1.01 | OD45907/2025-2026:Supply, conveyance installation testing and commissioning of 230 V, 50 hz, 1800 Lumen, 0.8 pf, 15% THD, 2.5 KV Lighting surge protection type 18 w 1200 mm LED pre-wired light fittings complete with all accessories . directly on wall or ceiling and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire etc as required. | 2 | each | 1,000 ₹2,000 | 550 ₹1,100 Lowest |
Tender Value
₹37,662
Closing Date
26 Jul 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
ASSISTANT ENGINEER
ASSISTANT ENGINEER LID EW KOTTARAKKARA MUNCIPALITY
RE TENDER MP-LADS 2023-24 GENERAL ELECTRICAL WORK KOTTARAKKA MUNCIPALITY CONSTRUCTION OF ANGANVADI NO.3 OF GANDHI NAGAR DIVISION 14
2025_LSGD_770216_9
08/2025-26/AE/LSGD/KTRMC
Open Tender
Electrical Works
Item Rate
180 days
KOTTARAKKARA
Please refer Tender documents.
8 documents required · 8 mandatory
₹335
Yes
Yes
13 Nov 2025
19 Jul 2025
29 Jul 2025
19 Jul 2025
26 Jul 2025
19 Jul 2025
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
finance_1272564.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .