| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.9 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | Rejected-Technical | - | Rejected-Technical L2 |
| Sl No | Description | Qty | Unit | S.ANILKUMAR L2 | SAJEEV S L1 |
|---|---|---|---|---|---|
| 1.00Instalation of AC unit in 86MLD Raw Water and Clear Water Pump Houses | |||||
| 1.00 | OD172708/2024-2025:Supply, Installation and commissioning of 4 ton capacity Ductable Air Conditioner unit of reputed make and following specification . Star rating 4 - star and above, Fully Inverter Technology Ac with anti corrosive black epoxy resin coating along with hydrophilic coating, 100% copper condenser coil, R410A refrigerant gas and 3 phase 430V 50Hz power supply .Including fixing of indoor & outdoor units, initial Refrigerant R410A gas charging as per manufacturer standards, giving power connection to nearest power plug point/MCB/DB connecting indoor and out door units using hard drawn copper refrigerant pipes insulated with nitrilerubber or equivalent material. Necessary opening on wall shall be restored to normal using cement plastering(Drain pipe line shall be properly fixed and clamped to line and level as per the direction engineer in charge. Make LG/Blue star/ Hitachi/Mitsubishi/Carrier/Daikin with minimum 5 year replacement guarantee if the manufacturer not provided more than that .. | 4 | no | 2,75,000 ₹11,00,000 | 2,10,811.01 ₹8,43,244.04 Lowest |
| 1.00 | OD172707/2024-2025:Supply and providing copper tube refrigent lines (both suction and discharge) using hard drawn copper pipe of the sizes reccomended by manufacturer including suitable thickness nitrile rubber thermal insulation of good quality to extend the refridgent gas connection till out door unit as required at site. | 80 | metre | 4,100 ₹3,28,000 | 3,564.62 ₹2,85,169.6 Lowest |
| 1.00 | OD172706/2024-2025:Supplying and laying additional CPVC drain pipe of good quality and suitable size to extend water drainconnection till nearest silt terminal as required at site. | 20 | metre | 190 ₹3,800 | 182.51 ₹3,650.2 Lowest |
| 1.00 | OD172709/2024-2025:Supply and drawing additional control cabling of required size as per manufacturer specification between indoor and out door units 4C X 4 Sqmm flexible copper wire | 80 | metre | 700 ₹56,000 | 580.6 ₹46,448 Lowest |
| 1.00 | OD172705/2024-2025:Supply and fixing support stand /clamp for fixing the out door using suitable support bars /anchor bolts and safety hook etc up to includingall acessories | 4 | no | 9,000 ₹36,000 | 8,538.8 ₹34,155.2 Lowest |
| 1.01 | OD172711/2024-2025:Supply and fixing PVC vinyl floor mat with thickness of 1.5mm as per direction of departmental officers | 75.86 | sqm | 700 ₹53,102 | 648.1 ₹49,164.87 Lowest |
| 1.01 | OD172710/2024-2025:Provinding PCC foundation for AC outdoor unit | 4 | no | 9,500 ₹38,000 | 7,819.91 ₹31,279.64 Lowest |
Tender Value
Refer Docs
EMD Value
₹45,000
Closing Date
7 Jul 2025, 3:00 pmClosed
EE,HWD,AVK
HWD,ARUVIKKARA
State Plan-2024-25-UWSS - Urgent maintenance of Variable Frequency Drive (VFD) starters of 86 MLD Raw Water and Clear Water Pump Houses at Aruvikkara-Supply, Erection and Commissioning of 4 nos Industrial AC units for VFD panel rooms for providing em
2025_KWA_773308_1
80/2024-2025/HWD/RT3
Open Tender
Civil Works - Others
Item Rate
180 days
WORK
Please refer Tender documents.
3 documents required · 3 mandatory
₹3,257
Yes
₹45,000
Yes
27 Aug 2025
1 Jul 2025
8 Jul 2025
1 Jul 2025
7 Jul 2025
1 Jul 2025
Amount
Instalation of AC unit in 86MLD Raw Water and Clear Water Pump Houses
OD172708/2024-2025:Supply, Installation and commissioning of 4 ton capacity Ductable Air Conditioner unit of reputed make and following specification . Star rating 4 - star and above, Fully Inverter Technology Ac with anti corrosive black epoxy resin coating along with hydrophilic coating, 100% copper condenser coil, R410A refrigerant gas and 3 phase 430V 50Hz power supply .Including fixing of indoor & outdoor units, initial Refrigerant R410A gas charging as per manufacturer standards, giving power connection to nearest power plug point/MCB/DB connecting indoor and out door units using hard drawn copper refrigerant pipes insulated with nitrilerubber or equivalent material. Necessary opening on wall shall be restored to normal using cement plastering(Drain pipe line shall be properly fixed and clamped to line and level as per the direction engineer in charge. Make LG/Blue star/ Hitachi/Mitsubishi/Carrier/Daikin with minimum 5 year replacement guarantee if the manufacturer not provided more than that ..
OD172707/2024-2025:Supply and providing copper tube refrigent lines (both suction and discharge) using hard drawn copper pipe of the sizes reccomended by manufacturer including suitable thickness nitrile rubber thermal insulation of good quality to extend the refridgent gas connection till out door unit as required at site.
OD172706/2024-2025:Supplying and laying additional CPVC drain pipe of good quality and suitable size to extend water drainconnection till nearest silt terminal as required at site.
OD172709/2024-2025:Supply and drawing additional control cabling of required size as per manufacturer specification between indoor and out door units 4C X 4 Sqmm flexible copper wire
OD172705/2024-2025:Supply and fixing support stand /clamp for fixing the out door using suitable support bars /anchor bolts and safety hook etc up to includingall acessories
OD172711/2024-2025:Supply and fixing PVC vinyl floor mat with thickness of 1.5mm as per direction of departmental officers
OD172710/2024-2025:Provinding PCC foundation for AC outdoor unit
S.ANILKUMAR (BID ID -2242554)
Bidder Name
S.ANILKUMAR
SAJEEV S
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.PDF
finance_1262867.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .