Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance FATEHPORA POSH BAGH BARAMULLA JAMMU KASHMIR 193101 UDYAM JK 03 0027297 | BARAMULLA | JAMMU AND KASHMIR | 193101 | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 4 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 5 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹8.3 L
EMD Value
₹16,490
Closing Date
30 Oct 2024, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer ED Baramulla
Executive Engineer ED Baramulla
Creation of100 KVA Sub Station with allied HT/LT Network at Syed Karim Chijhama Under PRI
2024_PDD_259631_1
EDB/55
Open Tender
Electrical Works
Turn-key
30 days
Creation of100 KVA Sub Station with allied HT/LT
Please refer Tender documents.
3 documents required · 3 mandatory
₹510
Yes
Executive Engineer ED Baramulla
₹16,490
Yes
31 Oct 2024
12 Oct 2024
31 Oct 2024
12 Oct 2024
30 Oct 2024
14 Oct 2024
12 Oct 2024 - 14 Oct 2024
Amount
Supply,Testing,Loading,Transportation,Unloading, Installation, and Commissioning of 11/0.433kV, 100kVA 3-Phase Distribution Transformer with Bimetallic Terminal Connectors Energy Level-2, Alminium wound and with LV Cable Box having detachable Alminium Gland plate with LV Bimetallic terminal connection suitable for vertical take off cable.
Supply,Testing,Loading,Transportation,Unloading, and Erection of Steel Tubular Pole, 9 Mtr. Long Pole(ST-410 SP33) with planting depth of 1/6 th of the height of the pole, (9 mtr. Long ) as per approved drawings/standards
Supply,Testing,Loading,Transportation,Unloading, and Erection of Steel Tubular Pole, 8 Mtr. Long Pole(SP15) with planting depth of 1/6 the of the height of the pole, (8 mtr. Long ) as per approved drawings/standards
Supply,Testing,Loading,Transportation,Unloading, , Laying ,Stringing, Tensioning & Binding of ACSR Conductor, (30mm2 ACSR Conductor) as per approved drawings/standards
Supply,Testing,Loading,Transportation,Unloading and Fixing of G.I Channel / Angle / Flat of sizes including Clamps as per approved drawings/standards
Supply,Testing,Loading,Transportation,Unloading and Fixing of 11KV Polymeric composite pin insulators 12kV, 5kN, lightening impulse 75kV positive and 80kV negative , creepage distance 320mm as per approved drawings/standards
Supply,Testing,Loading,Transportation,Unloading and Fixing of G.I Channel V-X arms 75x40x6mm with Top bracket including suitable clamps/collars (05Nos.) As per REC Standard as per approved drawings/standards
Supply,Testing,Loading,Transportation,Unloading and Fixing of 11KV Polymeric composite disc insulators 12kV, min falling load 45kN, lightening impulse 75kV positive and 80kV negative , creepage distance 320mm as per approved drawings/standards
Supply,Testing,Loading,Transportation,Unloading, Installation and commissioning of 11KV G.O, AB switch 3-phase, 3pole,200Amp, vertical type as per approved drawings/standards
Supply,Testing,Loading,Transportation,Unloading, Installation and commissioning of 11kV Horn Gap Fuse Set 3 Phase 200A as per approved drawings/standards
Supply,Testing,Loading,Transportation,Unloading, Installation and commissioning of 11kV Gapless surge arrestor, 9 kV, 10kA, LA with polymer housing station type as per approved drawings/standards
LT Distribution Box for 100kVA DTR with 160Amp MCCB 3P 16kA for incomer & 100Amp MCCB 3P 16KA 2No. for outgoing circuit.
Supply,Testing,Loading,Transportation,Unloading and fixing of Sundry items like Aluminium lugs, Jumpers, Binding tapes etc.
Supply,Testing,Loading,Transportation,Unloading, Installation and commissioning of 120sqmm Single core cable 1.1kV Grade XLPE un-armoured FRLS type.
Supply,Testing,Loading,Transportation,Unloading and fixing of Galvanised Nuts & Bolts of sizes
Supply,Testing,Loading,Transportation,Unloading and fixing of Earthing of Sub Station . This includes Excavation of earth pit dia 650mm & depth 3000mm, installation of earthing pipe of 40mm nominal bore & 4mm wall thickness & length 2.5mtr long as per IS 1239. GI strip for neutral earthing of size 25mmX3mm for connection of transformer body, GO set & lightening arrestors as per IS 2629/85, GI nut & bolts refilled with earth enhancement materials and earth chamber made of brick masonary with RCC slab cover. as per approved drawings/standards
Supply,Testing,Loading,Transportation,Unloading and fixing of Galvanised stay set with 50X8mm stay clamp, guy insulator (02nos), anchor plate (200X200X6)mm nut bolts, 02nos turn buckle, 1.8m long, 16mm diameter solid GS stay rod & 7/3.15mm dia GI stranded wire complete as per approved drawings/standards
Supply,Testing,Loading,Transportation,Unloading and fixing of G.I LT structure mukhi type with shackles as per approved drawings/standards
Supply,Testing,Loading,Transportation,Unloading and fixing of Spike earthing rod 20mm 2.5mtr long with G.i strip (25X3)mm
Supply,Loading,Transportation,Unloading, Laying & Testing of Cement bottoming for ST Poles in the mixture of 1:2:4 (20mm nomnal Aggregate as per standards 0.5cum / pole as per approved drawings/standards
Supply,Loading,Transportation,Unloading, Laying & Testing of Cement bottoming for ST Poles in the mixture of 1:2:4 (20mm nomnal Aggregate as per standards 0.4cum / pole as per approved drawings/standards
Providing & Painting of Poles with one coat of Red Oxide and two coats of aluminium paint and as per approved drawings/standards
Supply,Loading,Transportation,Unloading and fixing of Danger Plate with clamps as per approved drawings/standards
Supply,Loading,Transportation,Unloading and fixing of GI Barbed wire for Anti climbing device as per approved drawings/standards
Supply,Loading,Transportation,Unloading and fixing of Sign Board (2X2 feet) along with required accessories like clamps, nuts and bolts with all details viz. Name of the Village, Name of the Work,Head,Date of Start,Date of completion, Implementing Agency(KPDCL O&M Division Baramulla), Name of the contractor.
ALIF INFRAPROJECTS PVT LTD (BID ID -2200984)
M/S H.B.C ENGINEERING (BID ID -2200670)
AL-BARKAT ELECTRICICAL WORKS (BID ID -2196800)
M/S POWER PACK ELECTRICAL n MECH ENGG WORKS (BID ID -2197176)
M/s AHMADULLA AND SONS (BID ID -2201807)
stage.html
html • 0.02 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .