Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.3 LAccepted-AOC | L1 | Accepted-AOC Accepted being lowest bidder | |
| 2 | L2₹39.7 L+₹1.4 L (3.64%)Rejected-AOC MARYADA 111 SHIKARGARH KANHAIYA NAGAR JODHPUR 342001 | JODHPUR | RAJASTHAN | 342001 | L2 | Rejected-AOC Rejected being higher bidder | |
| 3 | L3₹41.3 L+₹2.9 L (7.63%)Rejected-AOC OPP INCOME TAX OFFICE PAOTA C ROAD JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L3 | Rejected-AOC Rejected being higher bidder |
Tender Value
₹43.0 L
EMD Value
₹86,000
Closing Date
9 Mar 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF Jodhpur
GE AF Jodhpur
ADDITION ALTERATION OF STATION ARMOURY P 85 OF SU UNDER GE AF JODHPUR
2024_MES_641818_1
8623/E8
Open Tender
Civil Works - Others
Item Rate
180 days
GE AF Jodhpur
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE AF Jodhpur
₹86,000
Yes
20 May 2024
10 Feb 2024
11 Mar 2024
10 Feb 2024
9 Mar 2024
26 Feb 2024
Amount
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in any type of soil complete all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and exc 1.5 m in depth but n exc 3.0m depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in any type of soil all as specified and directed.
M&L for PCC 1:4:8 type D-2 (40mm graded aggregate) in foundation, sub-base,filling and mass concreting complete all as specified and directed.
M&L for RCC M-25 design mix in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc. complete all as specified and directed.
M&L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter including flat & fair finished surfaces complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in hard/dense soilcomplete all as specified and directed.
M&L for RCC M-25 in Column, pillars, piers, postand struts complete all as specified and directed.
M&L for RCC M-25 in beams, cantilevers, bressummers, over 1.5M span complete all as specified and directed.
M&L for RCC M-25 design mix in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M&L for Pre-cast cement concrete 1:3:6 type C-1 (20mm graded aggregate) block masonry with solid blocks, exc. 10 cm in width and setting in mortar1:6 complete all as specified and directed.
M&L Moorum/red bajri filling in floors or pavings, laid in layers n exc 15 cm thick spread, levelled and rammed including watering complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 (40mm graded aggregate) in floor, sub-floor 75mm thick complete all as specified and directed.
M&L for Formwork to sides of pillars, posts, struts, piers, columns and stanchions for rough finsihed surfaces of concrete complete all as specified and directed.
M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) etc all as specified and directed.
M&L for Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frame) exc 1.5 sq. m but n exc 4 sq. m each and refixing to other location complete all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frame) not exc 1.5 sq. m and refixing to other location complete all as specified and directed.
Demolition of brickwork or stone/ boulder masonry, built in cement/ lime mortar including all quoins, arches, pillars,etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
M&L for random rubble stone masonary in cm 1:6 all complete all as specified and directed.
S&F of steel window fixed type with glazing bars complete all as specified and directed.
S&F 4 mm thick sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and directed.
M&L for rendering 10mm thick in CM 1:6 on block masonry surfaces or surface other than fair face of brickwork of walls including finish even and smooth surfaces using without extra cement complete all as specified and directed.
M&L for rendering 15mm thick in CM 1:4 with WPC on stone masonry /Block masonry surfaces or surface other than fair face of brickwork, including finish even and smooth surfaces without using extra cement complete all as specified and directed.
M&L for rendering 5mm thick in CM 1:3 on fair faces of brick work or concrete surfaces on ceiling including finish even and smooth surfaces without using extra cement complete all as specified and directed.
Demolition cement concrete in reinforced concrete (reinforcement cut as required to facilitate demolition) Roofs, floors (other than ground floors), beams, staircases, landing,chajjas and similar suspended work complete all as specified and directed.
Dismantling, floor, hearth or wall tiling /terrazo including cement mortar bedding but not backing and removing rubbish off the premises complete all as specified and directed.
M&L for machine cut kota stone 40-50mm thick over cement mortor 1:6 as DPC all arround complete all as specified and directed.
M & L for machine cut kota stone slab flooring 20-25mm thick over cement screed 20mm thick in cement mortor (1:6) jointed with grey cement slury mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
S & F factory made 35 mm thick IInd class hard wood Plain framed, panelled shutter (two panel) with lock rail & panel of 9mm B.W.P. commercial ply . The size of rail & stile as per IS: 1003 (Part I), Kiln seasoned & chemically pressure treated complete all as specified and directed.
M & L for machine cut kota stone 20-25mm thick over 10 cm thick cement plaster in cement mortor 1:4 on skirting, dado, riser of steps & pillars jointed with grey cement slury mixed with pigment to match the shade of the stone including rubbing and polishing complete all as specified and directed.
M & L for prepration of roof surface before roof treatment using screed bed or bedding layer of mortar in C:M 1:3, 15mm thick even and smooth complete all as specified and directed.
M&L for applying evenly a tack coat of industrial bitumen grade of 85/25 at the rate of 1.2 kg per sqm including cleaning surfaces complete all as specified and directed. (Note : 2 coats shall be applied. Ist coat for bonding material below membrane and IInd coat on top of membrane. Each coat shall be paid seperately.)
M&L for APP modified polymeric membrane, centre core of 100 micron HMHDPE, Outer film 20 micron each, thickness 3.00mm , having weight 3.00 kg / Sqm laid on primed surface by forced application and finally finished with aluminium paint @ 0.20 Ltr per sqm complete all as specified and directed.
M&L for preparing undecorated newly plastered surfaces of wall applying two coat of OBD over and including a coat of primer complete all as specified and directed.
M&L for preparation of newly plastered wall sufaces and applying two coats of 100% Premium acrylic paint having VOC less than 50 gm/litre and UV resistance asper IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Deport Tinted) with silicon additives @ 1.43 Litre/10 Sqm over and including a priming coat of exterior primer applied @ 0.90 liter/10 Sqm complete all as specified and directed.
M&L for preparing undecorated newly plastered surfaces of ceiling and apply three coat of white wash complete all as specified and directed.
M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified and directed.
Removing excavated material exc. 1.50 km but n exc. 5.0 km and and depositing where directed.
M&L for preparation of new or previously untreated wooden surfaces of any description, not other wise described over 10cm width or girth by filling coat with grey filler or liquid wood filler transparent and bringing forward surfaces to smooth even finish and apply two coat of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
S&F mild steel barrel tower bolt 200 mm long extruded section complete all as specified and directed.
S&F mild steel sliding Bolt 300mm long not less than12mm dia and including min 6 bolts and nut complete all as specified and directed.
S&F mild steel pressed handle ovel type, stove enamelled black 150 mm long complete all as specified and directed.
M&L for hardcore of gauge n exc. 50mm and depositing spread and levelled in layers not exc15 CM thick watered and rammed to a true surface completed all as specifed and directed.
M&L for PCC 1:3:6 type C-2 (40mm graded aggregate) in plinth protection 75mm thick complete all as specified and directed.
M&L for roof trusses (framed) , trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing(Beam,tee,angle,channel or flat sectionns) including distance pieces,cleats etc conforming to Fe-410W Grade E-250 Quality A complete all as specified and as directed.
M&L for framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe-290 Gde-E-165 complete all as specified and as directed.
S&F of pre-painted galvalume aluminnum zinc coating GI based corrugated steel sheet 0.5mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete as specified and directed.
M&L for PCC 1:2:4 type B-1, 20mm graded aggregate for benching/grouting of channels complete all as specified and directed.
M&L for preparation of newly or previously untreted steel surface of any description, over 10cm in width or girth, not otherwise described, priming with one coat of red oxide, zinc chrome and applying two coat of synthetic enamel (ordinary tint) complete as specified and directed.
M&L for preparation of old previously treated wall surfaces and applying two coat of OBD complete all as specified and directed.
S&F of Iron safe (Chest) fire proof, gas cutter proof and satisfying all relevent IS standards with dimensions 652mm (H) x 521mm (W) x 570mm (D) with dual control high precision 8-lever locks protected with unique drill-defeat shield in the door, with additional relocking device provided beyond the standard BIS for extra protection against attack through keyhole, tested as per BIS standard IS 550:2014 with minimum weight 385 kg including providing suitable size foudation in PCC 1:2:4 type B2 and fixing over it complete all as specified and directed. Make - Godrej Cat No DEF PRIME 26. (Note:-All working system along with manual and key's shall be made good and provided by the contractor).
S&F Metallic Rifle rack double floor single face with adjustable height compatible for 26 Nos of majority of service arms with locking system, tower height 82 inches, ground platform size 56"x18", middle plateform size 55"x18", cut frame of size 6"x3", butt rest size 4"x5", rifle hold frame size 55"x8", all component members of rifle rack shall be made up of section of MS square pipe of 2"x2" 2mm thick, 1"x3" 1.6mm thick, 1"x1.5" 1.6mm thick and MS sheet of 18 SW gauge, fixed in wall with suitable fastners, including rubber padding all as directed. Rifle rack shall be of weight not less than 80 Kg, shall be placed and fixed on platform of suitable size of PCC 1:3:6 type C-1 and shall be applied with two coats of synthetic enamel paint of approved tint over and including one coat of red oxide primer complete all as directed. Note : Cost of PCC platform shall deemed to be included in the rate quoted by contractor.
S&F Metallic Rifle rack double floor double face with adjustable height compatible for 52 Nos of majority of service arms with locking system, tower height 82 inches, ground platform size 56"x32", middle plateform size 55"x32", cut frame of size 3"x3.5", butt rest size 4"x5", rifle hold frame size 55"x12", all component members of rifle rack shall be made up of section of MS square pipe of 2"x2" 2mm thick, 1"x3" 1.6mm thick,1"x1.5" 1.6mm thick and MS sheet of 18 SW gauge, fixed in wall with suitable fastners, including rubber padding all as directed. Rifle rack shall be of weight not less than 115 Kg, shall be placed and fixed platform of suitable size of PCC 1:3:6 type C-1 and shall be applied with two coats of synthetic enamel paint of approved tint over and including one coat of red oxide primer complete all as directed. Note : Cost of PCC platform shall deemed to be included in the rate quoted by contractor.
Dismantling of existing flame proof lights of any capacity any make complete as specified and directed.
Supply and fixing LED light fitting 2x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete as specified and directed.
Material and labour for submain wiring with two single core PVC insulated multi stranded copper conductor cable FRLS of size 1.5 sqmm 1100 volt grade (ISI marked ) drawn through and including steel conduit pipe medium grade ISI marked (not less than 20 mm dia) along with fittings and accessories all fixed concealed on wall and surface on ceiling with necessary fittings, with one 1.5 Sqmm single core multi stranded copper conductor cable FRLS as earth continuity to common earth doly as earth wire complete all as specified and directed by the Engineer in Charge. Note : Two runs of main wire and one run of earth wire & one run of steel conduit shall be measured and paid as one length.
Material and labour for submain wiring with two single core PVC insulated multi stranded copper conductor cable FRLS of size 2.5 sqmm 1100 volt grade (ISI marked ) drawn through and including steel conduit pipe medium grade ISI marked (not less than 20 mm dia) along with fittings and accessories all fixed concealed on wall and surface on ceiling with necessary fittings, with one 2.5 Sqmm single core multi stranded copper conductor cable FRLS as earth continuity to common earth doly as earth wire complete all as specified and directed by the Engineer in Charge. Note : Two runs of main wire and one run of earth wire & one run of steel conduit shall be measured and paid as one length.
Supply and fix switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified and directed.
Supply and fix flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16A, 250V, 2P earth complete all as specified and directed.
S&F flame proof weather proof MCB DB TPN 4 way including MCB TPN 63 Amps-01 Nos, MCB SP 10 KA C series 6 Amps-05 Nos, MCB SP 10 KA C series 20 Amps-06 Nos, MCB SP10 KA C series 32 Amps-01 Nos complete all as specified and directed. Make:- Sudhir CAT Part No. MCDB 186 or equivalent in Shyam/Bliga as approved by GE.
S&F flame proof weather proof DB SPN DB 8 way including MCB SPN 10 KA C series 32 Amps-01 Nos, MCB SP 10 KA C series 6 Amps-04 Nos, MCB SP 10 KA C series 16 Amps-02 Nos complete all as specified and directed. Make:- Sudhir CAT Part No. MCDB 186 or equivalent in Shyam/Bliga as approved by GE.
M&L for earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 SSR Part-I 2009 and specified or indicated including excavation and earth work in any type of soil PCC (1:3:6) type C1 in chamber, precast RCC 50mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM (Weight not less than 4.00 Kg/Square metre) with PCC frame, funnel with wire mesh, 20mm bore medium grade GI watering pipe, lugs, 15mm mm bore medium grade GI protection pipe, test point etc complete all as specified and directed. Note:- (i) Item includes the cost of 7.5 metre GI pipe for protection of earth lead. (ii) Item includes the cost of 7.5 metre GI earth lead.
Supply & fixing on wall, installation, testing & commissioning of hi wall split units BEE 5 star rated indoor and outdoor unit (evaporator & condenser shall be of copper), inverter type copper tubing of required size and communication cable as per provided by OEM for proper installation and outdoor unit including wall/floor mounted stand complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality of capacity 2.0 TR 230 volt AC c/s AC supply all as directed.
Supply & fixing, installation, testing and commissioning voltage stabilizer of capacity 5 KVA high power efficiency,intelligent time delay system, in rush current capability, performs in wide input range,minimum input power(v) 170 V,maximum input power(v) 270V,wall mounted including having under voltage and over voltage protection, low and high voltage cutoff protection with intelligent time delay system latest IC technology complete all as specified and directed.
Material and labour for submain wiring with two single core PVC insulated multi stranded copper conductor cable FRLS of size 4 sqmm 1100 volt grade (ISI marked ) drawn through and including steel conduit pipe medium grade ISI marked (not less than 20 mm dia) along with fittings and accessories all fixed concealed on wall and surface on ceiling with necessary fittings, with one 4 Sqmm single core multi stranded copper conductor cable FRLS as earth continuity to common earth doly as earth wire complete all as specified and directed by the Engineer in Charge. Note : Two runs of main wire and one run of earth wire & one run of steel conduit shall be measured and paid as one length.
Supply & fixing sheet metal enclosure SPN with two pin and earth plug socket with & including 20 Amps MCB 'C' curve single pole 240 Volt AC complete all as specified & directed by the Engineer-in-Charge.
S&F copper tube(ISI marked) of size ⅝” or 3/8'' dia for any capacity of split type AC complete all as specified & directed by Engineer-in-charge.
S&F copper tube(ISI marked) of size ¼” dia for any capacity of split type AC complete all as specified & directed by Engineer-in-charge.
Material & labour in repairs fire resistance, elastomeric Nitrile rubber tubing (NBR) for Pipe insulation thickness 10mm of size ⅝" or 3/8'' dia of split type AC's any capacity complete all as specified & directed.
Material & labour in fire resistance, elastomeric Nitrile rubber tubing (NBR) for Pipe insulation thickness 10mm of size ¼” dia of split type AC's any capacity complete all as specified & directed.
Supply & fixing flexible drain pipe ( PVC BRAIDED hose pipe) of size 15 mm dia, for split type AC any capacity and any make complete all as specified & directed.
Supply, laying and commissioning of cable PVC sheathed cable with multistranded copper conductor of size 2.5 sqmm 4 core complete all as specified & directed.
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sqmm 4 core complete all as specified & directed.
Excavation in trenches in soft/loose soil not exceeding 1.5 m deep and not exceeding 1.5 mtr wide and getting out including forming bottom surface to required levels/gradients/slopes for foundations/laying of cable complete all as specified and directed.
Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25 cm in soft / loose soil complete all as specified and directed.
Removing excavated materials to a distance not exceeding 50 m and depositing where directed, at a level not exceeding 1.5 m above the starting point in soils complete all as specified and directed.
Material & labour for sand cushioning for XLPE cable with tibba sand (one layer of 80 mm thickness before laying of cable and other layer of 150 mm thickness after laying of cable) & punning down to 180 mm to provide a required cover complete all as specified and directed by the Engineer-in-Charge. Note:- Punned thickness only shall be measured and paid.
Material and labour for stone slab/patti, 40 to 50mm thick, rough dressed, Jodhpur stone slab cover in trenches for protection of cables, 25cm to 35cm wide and 80 cm long, laid dry abutting each other with gap between adjacent slab not exceeding 10mm over sand cushioning complete all as specified and directed.
M&L for earthing complete with copper earth plate electrode 60cm x 60cm x 3.15mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to and including copper earth strip 20x3mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion and excavation and earth work in any type of soil, PCC 1:3:6 type C1 in chamber, precast RCC cover 50mm thick in cement concrete 1:2:4 type B1, reinforced with welded steel wire fabric or XPM (Weight not less than 4 Kg/Sqm) with cast iron frame, funnel with wire mesh, 20mm bore GI pipe medium grade watering pipe, lugs, 40mm bore GI pipe medium grade protection pipe upto 7.5m complete all as specified and directed. Note:- (i) Item includes the cost of 7.5 metre GI pipe for protection of earth lead. (ii) Item includes the cost of 7.5 metre copper strip 20x3mm as earth lead.
S & F galvanised iron pipe 40mm dia medium grade with all fittings complete all as specified and directed.
M&L for test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw as required with all accessories complete all as specified and directed.
Supply and fix single pointed air termination aluminium rod 12mm dia 300mm long complete all as specified and directed.
S&F aluminium strip 25x3.15 mm complete with saddles and fixing screw for fitting the strip complete all as specified and directed.
Material & labour for PCC concrete block masonry type B1, 1:2:4 ( 20 mm graded stone aggregate) with block, exc 10 cm in width and setting in CM 1:6 complete all as specified and directed.
Supply and fixing 1.5 Sqmm 2 core multistranded copper conductor FRLS drawn through steel condiut including all accessories and fixnig on wall/ ceilling complete all as specified and directed.
Supply and fixing complete FIRE ALARM PANEL non addresseble type 4 zone suitable for Automatic Fire Detection & Alarm System including battery 12 V,7 AH-2 Nos complete all as specified and directed.
S & fix manual call point conventional type all as specified and directed.
Supply and fixing of Response Indicator (RI) suitable for Automatic Fire Detection & Alarm System complete all as specified and directed.
Supply and fixing of conventional type Photo Electric Smoke and heat Detector combination suitable for Automatic Fire Detection & Alarm System complete all as specified and directed.
S&F fire alarm sounders / sirens electronic type horizontal single stage continuos normal operation for atleast 50 minutes with sound level 65 DB to 120 DB measured at 1.5 Mtr with sound output variation of + 5 DB 500 mtrs range all as specified and directed by Engineer-in-Charge.
M/S KAUTILYA GARG
Harsh Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .