| 1.00Civil Works | ||||||
| 1.01 | 14.83 : Hacking of CC flooring including cleaning for surface etc. complete as per
direction of the Engineer-in-Charge. | 15.8 | sqm | 2 ₹31.6 Lowest | 3 ₹47.4 | 3 ₹47.4 |
| 1.02 | 50.6.1.1 : Solid block masonry using pre cast solid blocks ( factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part 1 of 1979 for foundation and plinth with thickness 20 cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete | 9.54 | cum | 5,891 ₹56,211.92 Lowest | 6,008 ₹57,328.34 | 5,949 ₹56,765.36 |
| 1.03 | 5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers | 5.64 | sqm | 645 ₹3,637.8 Lowest | 657 ₹3,705.48 | 651 ₹3,671.64 |
| 1.04 | 5.3 : Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 15<sup>0</sup> landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size). | 0.56 | cum | 11,421 ₹6,441.44 Lowest | 11,649.42 ₹6,570.27 | 11,535 ₹6,505.74 |
| 1.05 | 5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more | 56.4 | kilogram | 97.69 ₹5,509.72 Lowest | 99 ₹5,583.6 | 98 ₹5,527.2 |
| 1.06 | 13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) | 104.1 | sqm | 312 ₹32,479.51 Lowest | 318 ₹33,104.12 | 315.12 ₹32,804.31 |
| 1.07 | 13.48.1 : Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm | 124.1 | sqm | 166 ₹20,600.77 Lowest | 169 ₹20,973.07 | 167.66 ₹20,806.77 |
| 1.08 | od271442/2021_2022 : Providing and fixing aluminium work for doors, windows. Including Frame, shutter, 2 side laminted board, brass locks, hinges, handles, all works complete as per instruction from engineer in charge | 6.6 | sqm | 4,300 ₹28,380 Lowest | 4,386 ₹28,947.6 | 4,343 ₹28,663.8 |
| 1.09 | 9.48.2 : Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc | 90 | kg | 214.66 ₹19,319.4 Lowest | 218 ₹19,620 | 216.81 ₹19,512.9 |
Tender Value
Refer Docs
EMD Value
₹1 L
Closing Date
18 Apr 2023, 6:00 pmClosed
HOD(PPC AND PROJECTS)
KEL Kochi
INSTALLATION OF PNEUMATIC TUBE TRANSFER SYSTEM AT IIMS (GOVT. MEDICAL COLLEGE), PALAKKAD
2023_KEL_570480_1
KRO/ BDC/1390/2023
Open Tender
Miscellaneous Works
Item Rate
360 days
KEL Kochi
Please refer Tender documents.
6 documents required · 6 mandatory
₹8,850
₹1 L
Yes
20 Apr 2023
3 Apr 2023
20 Apr 2023
3 Apr 2023
18 Apr 2023
3 Apr 2023
3 Apr 2023 - 18 Apr 2023
Amount
Civil Works
14.83 : Hacking of CC flooring including cleaning for surface etc. complete as per direction of the Engineer-in-Charge.
50.6.1.1 : Solid block masonry using pre cast solid blocks ( factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part 1 of 1979 for foundation and plinth with thickness 20 cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.3 : Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 15<sup>0</sup> landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
13.48.1 : Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm
od271442/2021_2022 : Providing and fixing aluminium work for doors, windows. Including Frame, shutter, 2 side laminted board, brass locks, hinges, handles, all works complete as per instruction from engineer in charge
9.48.2 : Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc
13.48.3 : Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture
11.41.2 : Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.
od271440/2021_2022 : Core Cutting RCC with thickness of slab & Beam b/w 120mm to 200mm
od271441/2021_2022 : Masonry wall cutting.
15.57 : Dismantling aluminium / Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable surplus material and stacking of serviceable material with in 50 metres lead as directed by Engineer - in-Charge
12.53 : Providing and Fixing 15 mm densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture spintone /cosmos /Hexa or equivalent of size 595x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main 'T' runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross "T" of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main 'T' of size 24 x 28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main'T' at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross 'T' of length 600 mm and size 24x28 mm made of 0.33 mm thick (minimum) sheet to be inter locked at middle of the 1200x600 mm panel to from grid of size 600x600 mm, resting on periphery walls/partitions on a Perimeter wall angle pre-coated steel of size (24x24x3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture (Spintone / Cosmos/hexa) in the grid, including cutting / making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever require. Main 'T' runners to be suspended from ceiling using G.I slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size of 85x30x0.8 mm, spaced at 1200mm centre to centre along main 'T' bottom exposed with 24 mm of all T- sections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by by engineer-in-charge. Note:- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/opening (cut outs) having area less than 0.30 sqm. The calcium silicate ceiling tiles shall have NRC. value of 0.50 (Minimum), light reflection > 85% non - combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity < 0.043 w/m 0 KC.
ELECTRICAL WORKS FOR PNEUMATIC TUBE SYSTEM
1.31 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.14.1 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire
1.14.8 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required4 X 4 sq. mm + 2 X 4 sq. mm earth wire
od272218/2021_2022 : Supply, installation of following types of light fittings with all accessories directly on wall / in existing false ceiling and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required. LED Tube light (20W).
od272219/2021_2022 : Supplying and Installation of suitable size Gl box with modular plate and cover in Front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connection etc.
od272220/2021_2022 : Supply and installation of sheet steel, phosphatized and painted, dust and vermin proof 4-pole enclosure including copper bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB / isolator etc fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall, making good the damages, colour washing etc as required
od272221/2021_2022 : Supply and installation of of 400 mm sweep Wall fan with metallic blade and base along with necessary accessories for fixing etc as required.
1.53.1 : Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable
od272224/2021_2022 : Supply and fixing CAT6 socket outlets
od272225/2021_2022 : Supply and installation of 3 star inverter type 2 TR 3 star S/T AC unit including outdoor and indoor unit on the existing angle iron frame, fixing of standard length copper refrigerant pipes, making thermal insulation with ready made poly foam tube (thickness not less than 5mm) i/c leak testing, top up of gas giving electrical connections, testing and commissioning etc as required.
od272226/2021_2022 : Supply and laying of 3x 2.5 sq.mm PVC insulated PVC sheathed flexible copper conductor cable and giving connections to indoor/Out door unit etc as required .
1.10.3 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
2.3.3 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door
2.14.2 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.12.1 : Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.15.2 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.13.1 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
od272227/2021_2022 : Supply and installation of 40A 10KA TP MCB (C curve) with the following accessories suitable for 50 Hz, 240/415 V, AC supply conforming to IS 8828-1995 / IEC 60898-1 of the following current ratings in the existing enclosure / DBs and giving connections as required.
2.10.4 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
od272230/2021_2022 : Supply and installation of 20 mm dia good quality ISI mark, 10 kg/cm2, PVC pipe with accessories for protection of refrigerant pipe / drain water connection with necessary clamps etc as required.
od272231/2021_2022 : Supply and installation of MS frame for fixing the outdoor unit
od272232/2021_2022 : Supply and fixing of extra length of copper refrigerant pipe (Both cold & hot line)suitable for 1.5 TR A/C units (beyond the standard length supply with inverter AC) at site i/c insulating with 5mm thick ready made poly foam tube, brazing the pipe ,leak testing and giving connections in 63 mm dia flexible pipe and clamping the pipe etc as required
2.5.2 : Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required .(Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)8 way (4 + 24), Double door
90.12.7.39 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 6 sq mm with factory made clamp
Pneumatic Tube System
Tube PVC 160x3,2mm 5m
Bend PVC 160x3,2 R=800
Tube PVC 160x3,2 mm Clear
Bend PVC 160x3,2 R=800 Clear
Sleeve PVC 160x3,2x150
Сarrier swing lids 160 Red
Carrier 160 insert form
Cable
Cable revolver
Station 160 Intermediate
Station 160 RECEIVE ONLY
CARRIER RAIL Ø110-160
EXTENSION CARRIER RAIL Ø110-160
Diverter 160 2/3/4-way
Main Control Unit Two way
Power Supply Unit
Starter Unit, DC3 3-Phase Blower
Junction Box (3-phase)
Blower 2.2 KW
Air Reversing Valve
Silencer
Carrier Damping device 160
Tube PVC 110x2.3 mm 2.5m
Elbow 110x2.5 R=85
Sleeve PVC110
Glue PVC Tangit 125g
PC Hardware Supervision/Multi-line/RFID for (1) Line
PC Software Supervision/Multi-line, Basic, (First Line)
Tube clamp type 1 110
Tube clamp type 1 160
Stripe 445*4, 8mm black[ cable tie]
Station basket large (445x530x450)
Sandbag for basket (380x300x30)
ATX END STATION
Transfer Revolver - TRANSFER ZONE
KIT - V- FLANGE- TRANSFER ZONE
V- FLANGE FOR ZONE CONNECTION- TRANSFER ZONE
INBUILD CABLE DO 160- TRANSFER ZONE
CENSORING UNIT- TRANSFER ZONE
CONVEYOR BELT- TRANSFER ZONE
KIT X2 EXTENSION CARD- TRANSFER ZONE
EXCLUSIVE OF GST
Note :1 All materials, Items, Equipment shall be best branded items with IS and approved by client/KEL
2:Rate should be inclusive of Insurance,Transportation, delivery and installation cost for all items
3.Rate should be Exclusive of GST.
4.Work should be executed as per DSR/PWD specification and direction of Engineer at site.
5.CEMENT: Make use Malabar cement only as per Govt. direction and in case of non availabilty of Malabar cement use Ultra Tech, Dalmia, Ramco or eq. brand in the order of preference.
6.RCC: (Assessment of strength of concrete by Cube testing at Approved Govt labs as per IS) Cement make: Use Malabar cement only as per Govt. direction and in case of non availabilty of Malabar cement use Ultra Tech, Dalmia, Ramco or eq. brand in the order of preference.
7.STEEL REINFORCEMENT: Make: Tata,Vaishak, SAIL, JSW or eq primary make in the order of preference
8.CENTERING & SHUTTERING: (Centering and shuttering for different category of work may be considered separately.)
9. SOLID BLOCK MASONRY: Min. average compressive strength as per IS shall be 40-50kg/cm2 and has to be assessed by testing at Govt. lab. ( Variation in rate due to change in size of block and level of floor as per DSR/PRICE has to be considered)
11DELUXE MULTI SURFACE PAINT SYSTEM: Make: JOTUN, Asian, Berger, Nerolas or eq. in the order of pref.
12.VETRIFIED FLOOR TILES/ CERAMIC GLAZED WALL TILES: Make: Khajaria, Jhonson, RAK, NITCO, Cera or Eq. in the order of preference and prior sample approval from KEL, Client
13.ALUMINIUM WORK: Make: INDAL, JINDAL in the order of preference and prior sample approval from KEL, Client
14. ACRYLIC SMOOTH EXTERIOR PAINT/ SYNTHETIC ENAMEL PAINT/WHITE CEMENT BASED PUTTY/ CEMENT PRIMER: Make: Asian, Berger, Nerolas or eq. in the order of pref.
15.ELECTRICAL: Note: Rate should be inclusive of preparation of schematic diagram and getting approval from KSEB/Electrical Inspectorate. Statutory fees paid to KSEB/EI shall be paid by us separately.
Make of Electrical equipments/materials
All electrical materials/equipments shall be of best branded items with ISI, strictly as per schedule specification
Panel Boards: CPRI certified reputed manufacturers make
MCB/ELCB/DB - L&T/LEGRAND/SCHNEIRDER or equivalent
Cables & wires - Finolex/KEI/POLYCAB/RPG/V-GUARD
Switches/Sockets/Regulators - SCHEIDER/ABB/HAVELS/LEGRAND or equivalent
Cable Glands & Sockets - REPUTED MAKE , Cosmos
Indicating Lamps - TEKINIC/RISHUB/STC, L&T, Schneider or equivalent
Ceiling/Exhaust fan: Havells, Orient, Usha, Crompton Greaves, Bajaj
BUILDUS iCS LLP
akbar
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .