Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.0 LRejected-Finance PADMAVILASOM CHIRAKONAM PEYAD PO THIRUVANANTHAPURAM 695573 | THIRUVANANTHAPURAM | THIRUVANANTHAPURAM | KERALA | 695573 | L1 | Rejected-Finance agreement executed | |
| 2 | L2₹7.9 L+₹91,440.73 (13.1%)Rejected-Finance | L2 | Rejected-Finance agreement executed by L1 | |
| 3 | Rejected-Technical | - | Rejected-Technical L3 |
Tender Value
₹8.5 L
EMD Value
₹21,179
Closing Date
20 Sept 2022, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AEE
PWD Assistant Executive Engineer Medical College Sub Division PMG Thiruvananthapuram
Civil works
2022_PWD_507619_1
PWD/BLD/TR/2643/2022_5_1_1/1
Open Tender
Civil Works - Buildings
Item Rate
60 days
Thiruvananthapuram
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,870
Yes
₹21,179
Yes
5 Nov 2022
13 Sept 2022
22 Sept 2022
13 Sept 2022
20 Sept 2022
13 Sept 2022
Amount
Urgent Repairs
21.1.1.2:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately): For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)
21.3.2:Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness
21.2.2:Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.Pre- laminated particle board with decorative lamination on both sides
OD123693/2021-2022:Providing and fixing shelves and false ceiling with 4 mm thick aluminium composite pannelin approved shades. Cutting the ACP sheet in required shape for fixing. After cutting filling the edges for accurate position. Then remove scratch preotection stickers from aluminium composite panels on both sides. The stickers have gum under it, so the gum should be cleaned using cleaning solution ans banniyan waste. Then fixing the ACP panel using gumrebate, 55 screw, nuts, bolt, washes, cleats and wether silicon sealent. Then the masking tapes are used for designing the silicon in a perfect line. After designing the silicon the masking tape is removed from both sides, including cleaning searfolding loading unloading etc. complete.
OD122509/2021-2022:Providing and fixing fly proof(Mosquito net)stainless steel grade304 wire gauge to windows with Aluminium 'U' section 21.00*15.4*1.22mm(4041)for outer frame and 10*10*.9mm hollow tube for intermediate horizontals and fixing hinges, screws,etc complete.
14.72:Providing and fixing double scaffolding system (cup lock type) on the exterior side, upto seven story hight made with 40 mm dia. M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staricase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required location with essential safety features for the workmen etc. complete as per directions and approval of Engineer- in Charge. The elevational area of the scaffolding shall be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding. Note:- This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done .
13.84.2:Painting with synthetic enamel paint, having VOC (Volatile Organic Compound) content less than 150 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.Two coats
15.60:Disposal of building rubbish/ malba/ similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved
FRIDZY G
nishanth rajasekharan nair
Bidder Name
FRIDZY G
HARIKUMAR
nishanth rajasekharan nair
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
finance_726958.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .