| 1 | L1₹16.0 LAccepted-AOC JOGESHWARI W 758 ADARS NEW LINK ROAD 758 ADARS MUMBAI 400101 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400101 | L1 | Accepted-AOC L1 being lowest | |
| 2 | L2₹19.5 L+₹3.3 L (20.5%)Rejected-AOC 0 AJAY KUMAR 85 HASTAM HASTAM BANDA UTTAR PRADESH 210001 HASTAM BANDA UTTAR PRADESH 210001 UDYAM UP 13 0007628 | BANDA | UTTAR PRADESH | 210001 | L2 | Rejected-AOC being not lowest |
Tender Value
₹22 L
EMD Value
₹44,000
Closing Date
20 Feb 2021, 6:00 pmClosed
CWE HILLS DEHRADUN
HQ Commander Works Engineers Hills Mall Road Dehradun Cantt Dehradun 248003
REPAIR MAINTENANCE OF LT PANEL UNDERGROUND CABLES AND OTHER MISC ITEMS AT GRRC LANSDOWNE
2021_MES_417327_1
87038/LDN/E8
Open Tender
Civil Works
Item Rate
150 days
LASDOWNE
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE LANSDOWNE
₹44,000
Yes
5 Mar 2021
29 Jan 2021
22 Feb 2021
30 Jan 2021
20 Feb 2021
7 Feb 2021
30 Jan 2021 - 5 Feb 2021
Amount
Dismantling old unserviceable outdoor/indoor type switch gear panel alongwith assciated bus bar, metering, fuses, MCCBs,(U/S) switches, starters etc indication lamps including disconnecting power cables all as specified and directed by Engg-in-charge.
Material and labour for design ,supply, fabrication, Installation, testing and commissoning Factory made LT feeder pillar box outdoor type totally enclosed, dust and vermin proof, suitably ventilated, floor mounted, 415 volts, 3 phase and neutral, 50 Hz AC supply system, fully compartmentalized, both side openable, made out of 3.00 mm thick CRCA sheet, protection of enclousure IP-54 as per IS: 2147 of 1962 with pre-treatment and powder coated of approved colour including suitable frame work/support made out of suitable size angle iron/flat iron, front opening type with provision for cable entry, with proper ferrule and cable glands, internal wiring with PVC insulated multi stranded copper conductor FRLS cable of adequate size(minimum 1.5 sqmm), including required civil works/anchoring bolts for fixing, PCC foundation etc with and including following all as specified and directed by Engg-in-Charge (at MH Lansdowne):-
Notes for Item No 1 :- 1. Panel manufacturers should have in house powder coating plant with minimum 8 tank pretreatment of MS sheet facilities, dust free spray paint booth.(8 tanks pretreatment process includes: degreasing/water rinsing/de-dusting/water rinsing/activation/phosphating water rinsing/passivation). 2. Thickness of powder coating shall not be less than 80 microns and test certificate for powder coating shall be furnished along with LT panel 3. The panel manufacturer should have following certification: (i) CPRI certification degree of protection IP-54 ( should have IEC:61439-1-2 & IEC:60529 tests) (ii) CPRI certification short circuit with stand strength should be 50 KA RMS for 1 sec with initial peak of 105 KA (iii) CPRI certification rated current for short circuit not less than 5000A 4. All the electricals switch gear like MCCBs, MCB should be of same make 5. Drawing of panel board should be got approved from GE before fabrication. 6. Panel board should be fully compartmentalized in accordance to form 4 b of IEC 61439-1-2.
M& L, for earthing with galvanised steel earth plate of size 600 x 600 x 6 mm thick burried directly in ground not less than 2.5 mtr below groud level with top edge of earth plate not less than 1.5 meters below ground level connected by 25x4 mm GI strip as earth lead by means of brass nuts and bolt, thimbles, check nuts, washers including concrete chamber of PCC 1:3:6 type C1 using 20 mm graded stone aggregate, with fair finish, inetrnal surface of concrete chamber shall be given internal dia 300mm X 300mm , 15 mm thick plaster in CM 1:4 funnel with wire mesh, RCC pit cover of 320 x 320 x 80 mm size (1:2:4) type B1 (using 20 mm graded stone aggregate), adequate quantity of common salt, charcoal etc all, as shown in electrical plate No 3 of MES SSR Part-1(2009) and specified incuding and provision of GI strip upto 7.5 mtr long with 40 mm dia light grade GI pipe protection and watering pipe of GI 20 mm bore, Medium grade, including all excavation and earthn work and connecting the earth strip to an earthing test point/panel including testing on completion complete alll as specified and directed by Engr-in-charge NOTE:- (1) RCC pit cover shall be precast of RCC (1:2:4) type B1, 80 mm thick reinforced with XPM weighting not less than 4 Kg/Sqm in lieu of CI cover (2) Cost of GI strip upto 7.5 mtr shall deemed to be included in unit rate quoted by the contractor and GI strip beyound 7.5 mtr will be measured and paid seperately under relevant item of Sch A.
Disconnecting the old unserviceable ACSR and taking out the same complete all as specified and directed by Engg-in-charge
Supplying, laying, commisioning and testing of 1.1 KV grade XLPE insulated PVC sheathed, steel armoured aluminum stranded conductor LT UG cable ( Conforming to IS 7098) ISI marked in trenches / ducts / through GI pipes under roads of size 10 sqmm 2 core (for connection to Bldg with single phase connection from feeder Box) complete all as specifed and directed by Engg-in-Charge. Note;- The earth work, GI pipe shall be measured and paid sepretely under appropriate item of Sch A
Supplying, laying, commisioning and testing of 1.1 KV grade XLPE insulated PVC sheathed, steel armoured aluminum stranded conductor LT UG cable ( Conforming to IS 7098) ISI marked in trenches / ducts / through GI pipes under roads of size 16 sqmm 4 core (for connection to bldg from Feeder box) complete all as specifed and directed by Engg-in-Charge. Note;- The earth work, GI pipe shall be measured and paid sepretely under appropriate item of Sch A
Supplying, laying, commisioning and testing of 1.1 KV grade XLPE insulated PVC sheathed, steel armoured aluminum stranded conductor LT UG cable ( Conforming to IS 7098) ISI marked in trenches / ducts / through GI pipes under roads of size 70 sqmm 3.5 core complete all as specifed and directed by Engg-in-Charge. Note;- The earth work, GI pipe shall be measured and paid sepretely under appropriate item of Sch A
Supplying, laying, commisioning and testing of 1.1 KV grade XLPE insulated PVC sheathed, steel armoured aluminum stranded conductor LT UG cable ( Conforming to IS 7098) ISI marked in trenches / ducts / through GI pipes under roads of size 95 sqmm 3.5 core complete all as specifed and directed by Engg-in-Charge. Note;- The earth work, GI pipe shall be measured and paid sepretely under appropriate item of Sch A
Supplying, laying, commisioning and testing of 1.1 KV grade XLPE insulated PVC sheathed, steel armoured aluminum stranded conductor LT UG cable ( Conforming to IS 7098) ISI marked in trenches / ducts / through GI pipes under roads of size 150 sqmm 3.5 core complete all as specifed and directed by Engg-in-Charge. Note;- The earth work, GI pipe shall be measured and paid sepretely under appropriate item of Sch A
Supply and laying HT XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) ( Conforming to IS 7098) with stranded aluminium conductor, 11000 volts(Earthed) of 95 Sqmm, 3 core, ISI marked complete all as specified and directed by Engg-in-Charge. Note;- The earth work, GI pipe shall be measured and paid sepretely under appropriate item of Sch A
S&F Cable end jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable 95 Sqmm 3 core complete all as specified and directed by Engg-in-Charge.
M&L Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and directed by Engg-in-Charge.
Excavation in trenches in any type of soil n.exc 1.5 m wide and n.exc 1.5 m in depth for poles,laying under ground electric cable and GI tubing (where provided for protection of cables), stay and getting out, trimming the sides, forming bottom surface to required level in any type of soil complete all specified and directed by Engg-in-Charge.
Excavation in trenches in any type of soil exc 1.5 m wide and exc 1.5 m in depth for poles,laying under ground electric cable and GI tubing (where provided for protection of cables), stay and getting out, trimming the sides, forming bottom surface to required level in any type of soil complete all specified and directed by Engg-in-Charge.
Returning , filling in, any type of soil including spreading, leveling, watering and well ramming in layers n.exc 250mm thick, in any tupe of soil complete all as specified and directed by Engg-in-Charge.
Removing excavated material (surplus soil) to a distance not exceeding 50m and depositing where directed at a level n.exc 1.5 m above the starting point, complete all as specified and directed by Engg-in-Charge.
M&L for sand cushioning for under ground cable with layer of fine river dry sand 80 mm thick before laying of cable and 150 mm thick after laying of cable in trenches complete all as specified and directed by Engg-in-Charge. Note:- Punned (consolidated ) thicness of sand will be measured and paid.
M&L for un-reinforced precast concrete cable cover class HVP, type 1 with peak size 250mmx150mm x 40mm compliance with IS:5820-1970, as cable protection over sand cushioning perpandicular across the cable length wise in trenches complete all as specified and directed by Engg-in-Charge.
M&L for un-reinforced precast concrete cable cover class HVP, type 1 with peak size 300mmx180mm x 40mm compliance with IS:5820-1970, as cable protection over sand cushioning perpandicular across the cable length wise in trenches complete all as specified and directed by Engg-in-Charge.
M&L for 100 mm bore GI tube light grade laid under road/culvert/drain fixed to pole wall with help of flat iron clamps etcfor cable protection and making good surface of road with PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) complete all as specified & directed by Engg-in-Charge.
M&L for 80 mm bore GI tube light grade laid under road/culvert/drain fixed to pole wall with help of flat iron clamps etcfor cable protection and making good surface of road with PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) complete all as specified & directed by Engg-in-Charge.
M&L for 50 mm bore GI tube light grade laid under road/culvert/drain fixed to pole wall with help of flat iron clamps etcfor cable protection and making good surface of road with PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) complete all as specified & directed by Engg-in-Charge.
M&L for 32 mm bore GI tube light grade laid under road/culvert/drain fixed to pole wall with help of flat iron clamps etcfor cable protection and making good surface of road with PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) complete all as specified & directed by Engg-in-Charge.
AJAY KUMAR CONTRACTOR
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .