Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.8 LAccepted-AOC VIKASH NAGAR RAMGARH CANTT WARD NO 06 PO PS DISTT RAMGARH JHARKHAND PIN 829122 | RAMGARH | RAMGARH | JHARKHAND | 829122 | L1 | Accepted-AOC Bid is lowest and reasonable | |
| 2 | L2₹39.7 L+₹4.8 L (13.8%)Rejected-AOC VIKASH NAGAR GAUSHALA RAMGARH CANTT 829122 RAMGARH JHARKHAND | RAMGARH | JHARKHAND | 829122 | L2 | Rejected-AOC Bid is not lowest and reasonable | |
| 3 | L3₹46.5 L+₹11.6 L (33.3%)Rejected-AOC | L3 | Rejected-AOC Bid is not lowest and reasonable |
Tender Value
₹43.0 L
EMD Value
₹86,100
Closing Date
29 Feb 2024, 6:00 pmClosed
GARRISON ENGINEER
GE RAMGARH CANTT
PROVN OF 120 CHAIRS ALONGWITH STEPS IN MOTIVATION TRG HALL AS SPECIAL ITEMS MOTIVATING TRG HALL AT PRC RAMGARH CANTT
2024_MES_640084_1
8300/3232/E8
Open Tender
Civil Works
Item Rate
180 days
GE RAMGARH CANTT
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE RAMGARH CANTT
₹86,100
Yes
13 May 2024
1 Feb 2024
7 Mar 2024
1 Feb 2024
29 Feb 2024
15 Feb 2024
Amount
M&L for 75 mm thick plain cement concrete 1:2:4 type B-2 (using 40 mm graded crushed stone aggregate) as in floor/hardstanding etc surface finished even and smooth without using extra cement complete all as specified & directed.
M&L for Brick work using Sub class "B" bricks old size , straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:4 etc complete all as specified & directed.
S&F for 4.0mm thick sheet glass,ordinary quality & glazing with oil putty in square exceeding 0.5 Sq.m in each pane including hacking out old broken glass (any thicknesss, size,quality or any description) from any type of frame inlcuding punching or drilling out old glazing pins/spring clips & providing & fixing new ones as specified and directed.
S&F for 5.5 mm thick sheet glass,ordinary quality & glazing with oil putty in square exceeding 0.5 Sq.m in each pane including hacking out old broken glass (any thicknesss, size,quality or any description) from any type of frame inlcuding punching or drilling out old glazing pins/spring clips & providing & fixing new ones as specified and directed.
M&L for Vetrified ceramic dark shed/ double charged floor tiles 10 mm thick (Square/rectangular) area of each tile not exceeding 0.36 sqm, in floors etc set & jointed in neat cement slurry and pointed in cloured cement to match the shade of tiles over & including 15 mm thick screed bed in cement mortar (1:4) etc complete all as specified & directed.
S & F in repair galvanised mild steel wire cloth.0.56mm nominal dia of wire and average width of aperture 1.18 mm fixed with tinned tacks, or galvanised wire staples complete all as specified and directed.
S&F 125 mm long aluminium anodised barrel tower bolts of extruded section and fixed complete all as specified and directed.
M&L for framed work such as grills,gratings etc with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railing; framework of water tanks and similar work conforming to Fe 290- Gde E -165 & for portions framed and hung as gates, including pintle hinges, stops,hand-made sliding bolts, etc.complete all as specified and as directed
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) including removing the all rubbish off from the premises complete all as specified and directed.
M&L for preparation of newly plastered surface of wall and applying two coats of oil emulsion distemper over a coat of primer and a layer of putty (not less than 2.0 mm thick) complete all as specified and directed.
M&L for rendering 10 mm thick on face of brick masonry/concrete surface etc in CM (1:6) surface finished even & smooth using extra cement complete all as specified and directed.
M & L for moorum/red bajri filling in floors or pavings, laid in layers not exceeding 15 cm thick, spread, levelled and well ramming including watering as required complete all as specified and directed.
S & F Powder coated aluminium (minimum thickness of powder coating 50 micron) for frame and shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-Chief.
Taking down chowkats or frames with shutters exceeding 1.5 Sqm but not exceeding 4 Sqm each (without taking off shutters from the frames) including builders hardware etc & making good disturbed surface of wall with CM 1:3 complete all as specified and directed
S&F 30mm thick Plain Perforated PVC False Ceiling panel made of 5mm wall thickness PVC perforated sheet of size 600mm x 600mm. On 25mm Glasswool. 5.0mm (±0.25) Plain perforated PVC sheet of Density 600 Kg /Cum manufactured by an ISO-9001 - 2015 certified company, is stuck with glasswool on one side with suitable adhesive. The panel is inserted in a frame made of anodised Aluminum or GI 'T' section of size 1''x1'' (25mm x 25mm) in square type grid of size 2' x 2' (600mm x 600mm) The aluminium/ GI framework is supported from the ceiling with the help of 'J' hook and G.I. wire / 6mm M.S. rods of required sizes to maintain proper level. The aluminium/GI framework is supported on side wall with the help of aluminium/GI "L" section of size 1"x1" (25x25mm) angles complete all as per direction of Engineer-in-Charge, manufacturer's specification & drawing.
S&F Acoustic perforated prelam pvc wall panelling consisting of PVC Perforated panels having wall thickness of 5mm ( ±0.25 ) PVC sheet of Density 600 Kg /Cbm Manufactured by an ISO-9001-2015 certified Company, and the desired thickness of glasswool pasted with perforated sheet with suitable adhesive. The strips should have in their center a grove of 6mm width and 1mm depth for sinking the head of the screw used to fix the strips to the wall vertically at an equal interval of 10” between two PVC strips. The PVC strips shall be fixed to the wall using 65mm long M.S. screws through the groove in the strip by using PVC fasteners. The distance between two screws shall not be more than 200mm. A groove of 2mm may be left at the joint of two panels for aesthetic looks. The exact size of the panel and correspondingly of the grid may vary depending on the size of the wall. the wall using screws of adequate length. The screws shall be placed at a distance of 150mm and shall be 25mm from the edge of the insulated panel on all four sides of the panel. The PVC Strips of 5mm ( ± 0.25 ) thick PVC Sheet of width 75mm feathered at the edges shall be stuck using solvent cement adhesive at the places where two panels are joined, so as to cover the screw of both the panels, 0 using solvent cement. 90 heat bent strips of 5mm thick PVC sheets of width 75mm x 75mm feathered at the edges shall be stuck at wall joints / pillars etc. complete as per direction of Engineer-in-charge, manufacturer’s specification & drawing.
Demolition of brick work built in cement mortar including all quoins, arches, pillars etc. including removal of all rubbish off from the site complete all as specified and directed.
S&F 20 mm dia Harrison rails, mild steel chromium plated including fixing with & bracket , stops, rollers etc complete all as specified and as directed by Engineer-in-Charge.
M&L for prepartion of new or previously untreated steel surface of any description , not otherwise described over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified & directed.
S&F for GI water tubing medium grade, ISI marked, galvanised, 25 mm bore with all fittings, (such as tee, elbow, socket, union & short pieces) fixed to walls and ceiling or laid in floors including cutting chases for brick walls and making good the surface in cement mortar 1:3 complete all as specified & directed.
Taking down carefully unserveciable/damaged copper/aluminium surface (batten/coduit or casing caping) point wiring any length for light/fan/socket or power including unscrewing from board (fitting and fixture such as switches, sockets, ceiling rose, lamp holders, brackets, pendent, regulators, sockets ,light fittings etc) and removing material from site and making good to the disturbed surface to match with existing finish etc complete all as specified and directed.
M&L for following point wiring controlled by one way switch with using with FRLSH PVC insulated PVC unsheathed electric cable conforming to IS:694, 1100V grade AC, single core having multi stranded copper conductor of size 1.5 Sq.mm nominal cross sectional area for phase & neutral and including non metallic rigid PVC conduit ISI marked medium grade not less than 20 mm dia with all conduit accessories in concealed wiring system by cutting of wall and making good disturbed surface of wall (cutting except on ceiling for fan point only, on ceiling existing conduit will be used) & 1.5 Sqmm green PVC insulated unsheathed multistranded copper conductor as a earth wire connected to earth dolly by providing lugs including sunken type anodized pressed steel sheet terminal box (normal & modular type) made out of 1.6mm thick of suitable size, for mounting fittings/junction boxes including PVC board with bakelite sheet 2.8 mm thick laminated cover make sheet for housing/ fixing switches etc., including cutting holes for switches,sockets,regulators etc as per requirement including fixing with machine screw,washer etc complete all as specified and directed. Note: Proper colour coding to be adopted.
(a) One light and fan point controlled by one one way switch
(b) One 3/5 pin socket outlet 5 Amp on the same board with other swithes.
S & F switch piano flush button single pole one way 5/6 Amp, complete all as specified and as directed.
S & F switch piano flush button single pole one way 15/16 Amp, complete all as specified and as directed.
S & F socket outlet 2 in 1, 3 pin, 5Amp/6 Amp, flush type, universal, complete all as specified and as directed.
M&L for point wiring controlled by one way switch for 15 Amp 3/5 pin socket power point with using with FRLSH PVC insulated PVC unsheathed electric cable conforming to IS:694, 1100V grade AC, single core having multi stranded copper conductor of size 2.5 Sq.mm nominal cross sectional area for phase & neutral and including non metallic rigid PVC conduit ISI marked medium grade not less than 20 mm dia with all conduit accessories in concealed wiring system by cutting of wall and making good disturbed surface of wall (cutting except on ceiling for fan point only, on ceiling existing conduit will be used) & 2.5 Sqmm green PVC insulated unsheathed multistranded copper conductor as a earth wire connected to earth dolly by providing lugs including sunken type anodized pressed steel sheet terminal box (normal & modular type) made out of 1.6mm thick of suitable size, for mounting fittings/junction boxes including PVC board with bakelite sheet 2.8 mm thick laminated cover make sheet for housing/ fixing switches etc., including cutting holes for switches,sockets,regulators etc as per requirement including fixing with machine screw,washer etc complete all as specified and directed. Note: Proper colour coding to be adopted.
S & F socket outlet 2 in 1, 3 pin, 5Amp/6 Amp, flush type, universal, complete all as specified and as directed.
S&F for distribution board (DB) made out of steel sheet metal enclosure (CRCA sheet) dust and vermin proof Triple pole and neutral(TPN) 06 way (double door) with suitable Amps rated copper bus bar neutral bar ,earth bar 415 volts ,flush to wall including taking down carefully existing unserveciable /old main switches/distribution board , DBS along with MCBs complete all as specified and directed.
S& F 415V 10KA 'C' curve miniature circuit breaker (MCB) of TPN/FP 40 amp to 100 amp and current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and directed.
S & F miniature circuit breaker (MCB) SP 6 to 32 Amps ('C' Series) having current rating 10 KA,240 Volt in the MCB DB complete with connection testing and commissioning complete all as specified and directed. ted .
M&L for Earthing complete for poles/DBs with galvanised steel earth plate electrode, 600mm x 600mm x 6mm thick, buried directly in the ground (earth pit not less than 2.25m deep below normal (ground level) with top edge of the plate not less than 1.50m below normal ground level connected to galvanized iron wire 4mm dia as earth lead by means of bolts, nuts and washers of GI up to test point,GI tubing 20mm bore light grade protection pipe, GI watering pipe 20mm bore medium grade with funnel & wire mesh,charcoal dust and common salt 15cm in layers all round the earth plate, 40 mm thick pre-cast RCC cover (1:2:4) type B-1(using 20 mm graded crushed stone aggregate )reinforced with 8mm dia TMT bar @ 75mm c/c both way with mild steel handle 20mm dia round bar , plastering 15mm thick with CM (1:6:) internally and upto 150mm below ground level externally and chamber of (size of pit 300 mm x 300 mm x 300mm internal diamentions) PCC (1:3:6) type C-1(using 20 mm graded crushed stone aggregate ) (including earth work in any type of soil, removal of surplus soil to a distance n.exc.50m & returning filling) and connecting, testing on completion, all as shown on electric plate No. 03 of SSR-2009 Part-I including taking down old/ unserveciable existing earthing & making good disturbed surface of wall ,floors etc.complete all as directed. Notes: -(i) Earth lead & protection pipes length upto & including 7.50 metre. (ii) Earth filling shall be done by vegetable soil. (iii) Soil should be free from stone, boulders, aggregate, gravels etc.
S & F in repair LED luminairs 600mm x 600 mm,35/36 watt,220 volt AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holsers, LED lamps suitable for mounting with Armstrong/Grid ceiling including including connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and as directed.
S & F of air circulator, blower type, wall mounting, electric single phase, AC 240 Volts, 50 hz, heavy duty, 450mm sweep,1400RPM and connecting with flexible PVC insulated multi stranded copper conductor wire of required size as approved by GE complete all as specified and as directed.
S & F in repair for High density polyethylene (HDPE) pipe of 20 mm dia sutable for 6 Kgf / sq.cm working pressure complete all as specified and directed by Engineer-in-Charge.
S & F of Auditorium chair High Back of Trade pattern with cupholder (overall size 640 (L) x 675 (D) x1070 (H) mm with seat height 430 mm). Armrest should be PU armrest with cupholder in black colour. Auditorium Chair should be modern as well as highly functional and aesthetically appealing auditorium seating suitable for modern interiors of a modern auditorium. The shades of fabric of auditorium chair high back shall be as approved by GE including fixing of auditorium chair high back with grouting bolts (ICFS chemcial Anchor Stud M10 X 195 and chemical tube. Rest all as per directed by Engr-in-Charge. Make: Godrej & Bocyce Mfg Co. Ltd or Methodex System Ltd or Durain Industries Ltd
M/S Parmar Construction
M/S Bhushan Kumar Jain
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .