Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.3 CrAdmitted-Finance | ₹1.3 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.3 Cr+₹3.3 L (2.67%)Admitted-Finance NEAR SHIV SHAKTI DHARAM KANTA SHIV PURAM FULSUNGA RUDRAPUR U S NAGAR UTTARAKHAND | UDAM SINGH NAGAR | UTTARAKHAND | 244712 | ₹1.3 Cr+₹3.3 L (2.67%) | L2 | Admitted-Finance |
| 3 | Rejected-Technical | - | - | Rejected-Technical bid is non responsive |
| Sl No | Description | Qty | Unit | PERFECT ELECTRICALS AND ENGINEERS L2 | KIWI ZONE INFRATECH PVT.LTD. L1 |
|---|---|---|---|---|---|
| 1.00INTERNAL ELECTRICAL | |||||
| 2.00 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group - A | 580 | Point | 1,106 ₹6,41,480 | 1,079 ₹6,25,820 Lowest |
| 3.00 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group - C | 43 | Point | 1,599 ₹68,757 | 1,559 ₹67,037 Lowest |
| 4.00 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire | 1,028.37 | Metre | 254 ₹2,61,205.98 | 247 ₹2,54,007.39 Lowest |
| 5.00 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire | 3,135 | Metre | 300 ₹9,40,500 | 292 ₹9,15,420 Lowest |
| 6.00 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire | 852 | Metre | 364 ₹3,10,128 | 355 ₹3,02,460 Lowest |
| 7.00 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 6 sq. mm + 1 X 6 sq. mm earth wire | 80 | Metre | 478 ₹38,240 | 466 ₹37,280 Lowest |
| 8.00 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4 x 4 sq.mm + 2 x 4 sq.mm. earth wire | 50 | Metre | 585 ₹29,250 | 570 ₹28,500 Lowest |
| 9.00 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4 x 6 sq.mm + 2 x 6 sq.mm. earth wire | 80 | Metre | 822 ₹65,760 | 801 ₹64,080 Lowest |
| 10.00 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4 x 10 sq.mm + 2 x 6 sq.mm. earth wire | 20 | Metre | 1,095 ₹21,900 | 1,068 ₹21,360 Lowest |
Tender Value
₹1.3 Cr
EMD Value
₹2.5 L
Closing Date
19 May 2025, 3:00 pmClosed
DGM HQ BRIDCUL
BRIDCUL Opp Govt ITI Niranjanpur Saharanpur Road Dehradun
Electrification, CCTV, Fire Alarm, Fire Fighting and Allied work for Government Women Welfare/Rehabilitation Center (Women) and Government Girls House Haldwani Distt, Nainital.
2025_BRID3_83732_2
993/BRIDCUL/964/1/25 Dated 02.05.2025
Open Tender
Electrical Works
Item Rate
540 days
Haldwani Nainital
Please refer Tender documents.
3 documents required · 3 mandatory
₹5,900
MD - BRIDCUL
₹2.5 L
BRIDCUL Dehradun
2 Jun 2025
9 May 2025
19 May 2025
9 May 2025
19 May 2025
14 May 2025
13 May 2025
Amount
INTERNAL ELECTRICAL
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group - A
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group - C
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4 x 4 sq.mm + 2 x 4 sq.mm. earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4 x 6 sq.mm + 2 x 6 sq.mm. earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4 x 10 sq.mm + 2 x 6 sq.mm. earth wire
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 1.5 sq. mm
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 3 x 2.5 sq. mm
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 3 x 4 sq. mm
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 amps modular switch, connection etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required 5/6 A switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required 3 pin 5/6 A socket outlet
Supplying and fixing brass batten/ angle holder including connection etc. as required.
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required.
Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.
Supplying and fixing extra down rod of 10 cm length G.I. pipe, 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required Upto 450 mm sweep
Extra for fixing the Louvers/ shutters complete with frame for exhaust fans of all sizes.
Supply of LED 4ft Batten with a nominal system lumen output of 2000 lumens and a minimum system efficacy of 100 lm/W. The luminaire shall have a rated system lifetime of 25,000 burning hours at L70. The luminaire should have a color temperature of 4000K and CRI>80. The luminaire shall meet IP20 rating with THD < 10% and PF > 0.9. The luminaire housing should made of extrusion Al with a PC diffuser. The total power consumption should not exceed 21W (including driver).
Supply of Surface mounting round 10 Watt 15 Watt , suitable for 24Hr Continuous Operation, 100lm/W, PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70, complete in all respect.
Supplying of Bulkhead type light fitting complete with, wire guard, holder, electronic ballast 1 x 10 W lamp including connections etc
Supply of 9W to 15 W 3 Star LED Wall Light Blub complete in all respect.
Supply and fixing of LED Street light Fitting with mandatory driver set having die cast aluminium body and lenses suitable for 40Watt. and Confirming to IP66 protection having Company LOGO Engraved complete in all respect with 4000-5000 system lumens High Power LED with lenses, >110lm/W, PF>0.95, THD <10% at full load, CRI>70, Avg Life Class 50000Hrs@L70.
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 1200 mm sweep ceiling fan
Supplying of following size exhaust fan complete with gravity louver and connection with 3 core flexible wire as required.300mm EXHAUST FAN
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 63 A,25KA,FP MCCB
Supplying and fixing following way ,single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way, Double Door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 4 Way Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way Double door
Supplying and fixing following way surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required.(Note : Vertical type MCB TP DB is normally used where 3 phase outlet are required.) 4 way , (4+12) Double door
Supplying and fixing following way surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required.(Note : Vertical type MCB TP DB is normally used where 3 phase outlet are required.) 8 way (4 + 24), Double door
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole and neutral
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32 A 415 V "C" curve TP MCB complete with connections, testing and commissioning etc. as required
Supply installation testing and commissioning of LT panel Board for the extension of existing panel as per the following specification with proper copper earthing as recommended. The panel should be Designed as per the latest standard IEC 61439. The panel should have Bus bar clearance of 25 mm for Ph to Ph and 19 mm for Ph to neutral, Zero Stray voltage doors and panels, polyester glass support for insulation. The cable alleys should be 300 mm wide and it should be fitted with hinged door that open up to and angle of 95 Deg. The provision of cable entry should be from Bottom. The IP protection of panel should be IP-42 for external and IP2X for internal with 3B as Form of separation. The panel should be equipped with suitable size of CT and display meter for VAF measurement. Panel will be Electrical & mechanical Interlock.The panel should be suitable for seismic zonelOutgoing should be IP 54 and should have switchgears as below. Main LT Panel INCOMER:- 1 No 200 Amp. 4P MCCB of 25KA (Ics=Icu) Breaking Capacity, with 200 Amp 4P Changeover Switch with Multi Function Meter. 2 Set of phase indicating lamps with Single Pole MCB. 2 Set of ON / OFF indicating lamps with Single Pole MCB. BUS BARS:- 1nos. 250 Amps. TP&N aluminium bus bars (25 KA) OUT GOINGS:- 02 Nos 100 Amp FPMCCB , 05 Nos. 63 Amps. FP MCCB, 4 Nos. 32 Amps. 4P MCCB, 4 Nos. 32 Amps. DP MCB, 2 Nos. Spare
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. Details of cost for one each
Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories , and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but with charcoal or coke and salt) as required.
Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for connections etc. as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. Up to 35 sq.mm.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. Above 95 sq.mm. and upto 185 sq.mm.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required Up to 35 sq.mm.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required Above 95 sq.mm. and upto 185 sq.mm.
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required Upto 35 sq. mm (clamped with 1mm thick saddle
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. Upto 35 sq. mm (clamped with 1mm thick saddle)
Supply of following siz of 1.1KV grade multicore aluminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment 3.5 x 185 sq.mm
Supply of following siz of 1.1KV grade multicore aluminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment 4C x 6 sq.mm,
Supply of following size of 1.1KV grade multicore copper conductor XLPE insulated and PVC shethed unarmoured cable as per IS 7098:1988 with up to date amendment 3.5 x 25 sq.mm
Supplying and making cable end terminations with brass compression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. 3½ X 25 sq. mm (28mm)
Supplying and making cable end terminations with brass compression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. 3½ X 185 sq. mm (57mm)
'Supplying and making cable end terminations with brass compression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. 4 X 10 sq. mm (25mm)
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. 100mm dia
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. 90 mm dia (OD-90 mm & ID-76 mm nominal)
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required 100 mm wide x 50 mm depth x 1.6 mm thickness.
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 100 mm wide x 50 mm depth x 1.6 mm thickness.
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 100 mm wide x 50 mm depth x 1.6 mm thickness.
SITC of 25 Ltr. Glass line Geyser with all accessories Complete in all respect.
SUB-HEAD -II- FIRE DETECTION SYSTEM
Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required
Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required.
MANUAL CALL POINT Supplying, installation, testing & commissioning of addressable manual call point complete as required.
RESPONSE INDICATOR Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required.
Hooter cum strobe Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required.
Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required
Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:- a) Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency. c) Data Monitoring System complete with accessories. d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. e) Lightning and surge voltage protection. f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required.
Supply, Installation, Testing and Commissioning of 500 LPD SOLAR WATER HEATING SYSTEM with heat Exchanger type including electrical heater backup, makeup water tank including all fixing accessoiries with with protection net/jaali conforming to MNRE complete in all respect
Supply, Installation, testing and commissioning of 10KVA/10KW True Online, DSP Controlled online UPS with 1 phase AC input and 1 phase AC output with 30 min backup with 12V SMF batteries Bank with Rack. The UPS should be with IGBT Based Rectifier and IGBT based Inverter both and with LCD Screen Display & LED indicators for monitoring of its status along with same OEM make inbuilt Isolation Transformer at input side. The job includes the cost of Supply, installation, commissioning and testing charges including rack, connecting and other petty material required to complete the job. The UPS should have following specification. INPUT FEATURE :Input Voltage & Range window : 230 V AC 1 Phase +/- 20% Input Frequency window 45-70 Hz . Nominal Frequency 50 HzTotal Harmonic Current Distortion (THDI ) should be less than 5 % at full rated load Input power factor (PF) greater than or equal to 0.99 OUTPUT FEATURE : Output Power Factor should be unity.Output Power Capacity in watts (KW) 10KVA / 10KW Output Voltage - 200/220/230 V AC adjustable via the user interface Total Harmonic Distortion : < 2% for linear load & < 5% for 100% non-linear load Output Frequency range 50/60 HZ. Other Features UPS overall Efficiency : upto 94% ( AC to AC i.e Online Mode) and 98% ( Eco Mode ) without Isolation transformer Overload Capacity: A) 5 minutes at a load representing 125%, B) 60 second at a load representing upto 150% LCD Display: Normal Mode/Load on Battery/Load on Bypass/System Fault etc. as per industry standard on screen display. Bypass : UPS Should be built in Manual and Maintenance Bypass Operating Temperature : 40 degree C Noise Level :Less than 50 dBA Emergency Power Off (EPO) Should be available as standard Future expansion Feature : UPS shall be capable of integrated parallel operation up to upto 4 same units for future expansion.Isolation :UPS Should be with same OEM make inbuilt Isolation Transformer at Input side. Communications & Management :- Interface ports : USB/ RS 232 & optional SNMP . LCD Screen Display and LED indicatorsAlarms : Audible Alarm required for Mains failure, Low Battery, Inverter Trip, Over Temperature, Over Load Safty Standard & Certifications and Test reports ISO 9001 & 14001 certified OEM, Safety Standard: IEC62040-1, EMC: IEC62040-2, Performance IEC62040-3 , along with CE/UE and BIS certification. Product should be ROHS certified And with IP20 Protection. Product should be Make in India. ,Quoted model should be tested by SAMEER/ERTL/NTH or any Govt. approved NABL Accredited Lab. Bidder to submit the type test report from any Govt. LAB /NABL accredited LAB in supporting to above technical parameters. Warranty Terms : Three Years on UPS & Batteries both with onsite service Support SERVICE & Support : OEM should have 3-4 own /ASP based registerted service centers in the state for better & timely service support, need to share at least 2 engineers contact details with service center address details in the region of installation and OEM Turnover should not be less than 500 Crores/year in last 3 financial years with profitability. 10 years presence of OEM in Govt. project segment And Quoted product should be available on OEM Website with as per asked technical specifications Supplying, erection, testing & commissioning of VRLA-AGM maintenance free Battery 12V SMF batteries for 30 Minutes back up VAH of 18000VAH (12VX20 No. of 42AH) extra lead acid battery with thicker tubes suitable for UPS (Including Battery rack) as required complete in all respects and to the best satisfaction of Engineer-in-Charge 12V SMF (12VX20 No. of 42AH) Batteries for 30 Minutes backup or any other make approved by Engineer-in-Charge.
SUBHEAD - VI : AC Equipment
SITC of 1.5 Ton Hot and Cold Split Air Conditioner Complete in all respect.
S/F MS Outdoor Stand as required as possible Complete in all respect.
S/F 5 KVA Stabilizer copper winding for A.C Complete in all respect.
S/L 3 x 2.5 Sqmm core flexible Copper Counductor for control of A.C Complete in all respect.
S/L drain of Pipe 25mm with Albow socket Complete in all respect
S/L Copper Refrigerent pipe 5/8 and 1/4 Complete in all respect
SUB-HEAD -VII - EPABX & LAN SYSTEM
Supplying, drawing, connecting and testing of 0.5 mm dia annealed copper conductor PVC insulated PVC sheathed telephone wire in existing conduit/wire way duct etc. as required of following sizes: 2 Pair (4 core)
Supply, Laying Connectig ad testing of multi core (10 Pair) Telwphone cable of conductor size 0.5 mm dia annealed copper conductor PVC insulated PVC sheathed jelly Filled.
Supply,Laying connecting and Testing of 10 Pair cross Jumper type Telephone tag block krone make in surface /recess in wall required size of M.S box with hinged lockable dully stove enamel painted
Supply,Laying connecting and Testing of 10 Pair telephone tag block krone make in surface /recess in wall.Requried size of M.S box with hinged lockable duly stove enamel painted.
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required 1 or 2 Module (75mmX75mm)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Telephone socket outlet
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. RJ-45 Data Socket outlet
Supply,Installation Testing and Commissionning of Hybrid Server based EPaBX with 40 analog Extension ,4 digital Extension 04 CO with CLI Facilities system.
Supply and Installation of CLI based push button telephone set.Make- Singhtel,Panasonic,Alcatel
Propriatary Full duplex HF digital phone set with 12 ouble function programmable keys,4 line display ,call waiting ,3 way confrence,call transfer,User to user signaling.
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.1 run of cable
Supply Installation testing and commissioning of 24 port L2 Managed switch having port density 24 No.of 10/100/1000Mbps/4 1 G SFP Ports.
SITC of UTP CAT 6 UTP Patch Cord 3 Mtr.Make- RIT/Schinder/R & M/Comrax
Supply and Fixing of 12 U wall mounting Networking Rack.Make- Dynamic/Comrack
Supply Punching and Fixing of 24 ports Patch Panel Make-/RIT/R & M/Comrax
Supply,Laying of UNI Tube Single Mode 6 F Armored Fiber Optic Cable.
Labour chagres for optical fiber cable splicing and jointing with Termination. As Require As possible.
Supply and Installation of Single Mode SFP Module For Switch Complete in all respect.
Supply and Fixing of 25 mm Sizes of Medium class PVC conduit along with accessories in surface /recess including cutting the wall and making good thw same in case of recessed conduit as requried.
SUB-HEAD -VIII :- CCTV SYSTEM
Supply Installation Testing and commissioning of 4 MP (3072X1728)/(2560x1920) 25 fps OR Better Outdoor/ Indoor Bullet IP-IR Verifocal Camera Lens 3.5 mm to 9 mm lens motorised, lux (Color 0.397 lx mono 0.042 lx ) with IR 0.0 lux WDR 100 dB WDR or Better range, H.265, H.264, compression Day/Night , Electronic Shutter Automatic Electronic Shutter 1/3 to 1/15000 or Better micro SDXC SD card slot minimum support 32 GB or Better, Intelligent Dynamic noise reduction, Intelligent Defog, Rule based alarms and tracking, Line crossing, Enter/Leave field, Follow route, Loitering, Idle/ removed object masking Pixel counter, Motion Detection Minimum IR Range 30 meter and above, Rj45, G-711, single-to-noise ratio >50 db, Audio streaming Full-duplex/half duplex, ONVIF Profile S, G & T, IP 66, IK 10, POE, CE, UL, Certified, TEMPERATURE-10 C To 50 C.
Supply Installation Testing and commissioning of 4 MP (3072X1728)/(2560x1920) 25 fps OR Better Indoor Dome IP-IR Verifocal Camera Lens 3.5 mm to 9 mm lens motorised, lux (Color 0.397 lx mono 0.042 lx ) with IR 0.0 lux WDR 100 dB WDR or Better range, H.265, H.264, compression Day/Night , Electronic Shutter Automatic Electronic Shutter 1/3 to 1/15000 or Better micro SDXC SD card slot minimum support 32 GB or Better, Intelligent Dynamic noise reduction, Intelligent Defog, Rule based alarms and tracking, Line crossing, Enter/Leave field, Follow route, Loitering, Idle/ removed object masking Pixel counter, Motion Detection Minimum IR Range 30 meter and above, Rj45, G-711, single-to-noise ratio >50 db, Audio streaming Full-duplex/half duplex, ONVIF Profile S, G & T, IP 66, IK 10, POE, CE, UL, Certified, TEMPERATURE-10 C To 50 C.
Providing & fixing of VMS base license for viewing and recording for 32 camera.
Providing & fixing of 6 TB HDD servilance storage drive Complete in all respect
Supply Installations Testing and Commissioning of 65 " 4K ultra HD Smart /Google Display, HDMI Port, Component Video Inputs, 1 Digital Audio Out,
Supply Installations Testing and Commissioning of 8 PORT POE Managed Switch with 2 SFP ports 8X10/100/1000 advance layer 2 Switch. Power Budget should be sufficient (minimum 65Watt) to calculate the total Budget of cameras on site
S/F of ONLINE UPS 3 KVA with 60 min Backup, input single phase 160V-260V 50Hz, Output single phase 230V 50Hz, IGBT-PWM with inbuilt isolation transformer complete in all respects.
S/D of UTP 4 Pair CAT 6 LAN cable in the existing PVC conduit as required
S/F of 25 mm sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Fire Fighting System
Excavating trenches of required width for pipes cables etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m ncluding getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 m. Pipes, cables etc. exceeding 80 mm dia . But not exceeding 300mm dia.
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 100 mm nominal bore (pipe in pump room & pump room to FFTG shaft)
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 2 way - 100 mm dia M.S. Pipe
Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) (a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520 b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. (d) Suitable cement concrete foundation duly plastered and with anti vibration pads. 900 lpm at 35 m Head
Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required. (for terrace booster pump)
Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required (for terrace booster pump)
150 mm dia.
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 100 mm dia.
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 100 mm dia.
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 100 mm nominal bore
Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :Single headed Gunmetal
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 40 m
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :Gun metal
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :Gun metal
Providing and fixing standard fire mans axe with heavy duty insulated rubber handle.
Providing of FHC Door made of 16 gauge MS Sheet with frame of size 105x70mm complete door and frame assembly including all hardwares (Concealed Flush handle,Allen Key Lock, MS Hinges, 5mm Thick Float glass) & accesories . The door to be painted with fire resistance paint. The scope shall also include the painting of the frame with the same paint as the shutter or complete as per direction of Engineer-in-charge. (Approx. size of door: 900mm Wide & 1500mm Height)
Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required.
Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required.
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
P&F of CO2 Portable & Trolley Fire extinguisher, 4.5kg Carbon-Dioxide type Flat base Horn Including Valve, High Pressure Rubber Wire Braided Discharge Hose of not less than 10 mm dia. & complete in all respects including initial fill with CO2 Gas confirming to IS:15222.
P&F 9kg ABC MAP-90% Powder based Fire Extinguisher, Applicable Fire Class A, B & C, EPDM Rubber Hose, NRV Valve and Helium Leak Detection Tested, Internal Coating - Epoxy Powder and External Pure Polyester Powder Coated (UV resistant), IS 15683:2006 Marked.
PERFECT ELECTRICALS AND ENGINEERS (BID ID -382478)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.84 MB
sbdelectricalalliedworkwelfarerehabilitioncenter.pdf
Tender Documents • 1.78 MB
BOQ_99623.xls
BOQ • 0.40 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .