| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.6 LAccepted-AOC 67 NIRANJANPUR SAHARANPUR ROAD PO MAJRA DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L1 | Accepted-AOC ACEEPTED BEING LOWEST TENDER | |
| 2 | L2₹32.5 L+₹4.7 L (16.9%)Rejected-AOC | L2 | Rejected-AOC REJECTED BEING NOT LOWEST TENDER | |
| 3 | L3₹34.0 L+₹6.2 L (22.1%)Rejected-AOC | L3 | Rejected-AOC REJECTED BEING NOT LOWEST TENDER | |
| 4 | L4₹34.1 L+₹6.3 L (22.5%)Rejected-AOC 137 3 STREET NO 4 RAJINDER NAGAR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L4 | Rejected-AOC REJECTED BEING NOT LOWEST TENDER | |
| 5 | L5₹34.8 L+₹7.0 L (25.2%)Rejected-AOC | L5 | Rejected-AOC REJECTED BEING NOT LOWEST TENDER |
Tender Value
₹37.5 L
EMD Value
₹75,000
Closing Date
12 Nov 2022, 6:00 pmClosed
GE I RND DEHRADUN
GE I RND DEHRADUN DEAL RESIDENTIAL COMPLEX RAIPUR ROAD DEHRADUN 248008
PROVN OF STORAGE SHED AT FIRST FLOOR M F FACILITY, FRESH WATER SUPPLY IN KITCHEN OF B-7 ADDITION / ALTERATION TO WET CANTEEN IN BLDG NO 3A OF DEAL PROVISION OF EXHAUST FANS IN SOH, MOH, TYPE-II AND TYPE-III BUILDING AT VIGYAN VIHAR DEHRADUN
2022_MES_559474_1
GE(I)RND/9193/E8/22-23
Open Tender
Civil Works
Item Rate
180 days
DEAL DEHRADUN
Class D Category a (i) FOR UNENLISTED CONTRACTOR (i) Enlistment criteria may be seen in Para 1.4 and 1.5 of section of Part I of MES Manual on contracts-2020 as available in all MES formations (ii) Copy of police verification /passport.
6 documents required · 6 mandatory
₹500
Yes
GE I R N D DEHRADUN
₹75,000
Yes
19 Nov 2022
22 Oct 2022
14 Nov 2022
22 Oct 2022
12 Nov 2022
29 Oct 2022
22 Oct 2022 - 29 Oct 2022
Amount
M&L for Brick work with old size sub class B bricks straight or curved on plan exc 6m mean radius built in CM 1:6 Complete all as Specified and directed
M&L for 15mm thick plastering in CM (1:4) on fair faces of brick work or concrete surfaces of external wall finished even and fair without using extra cement complete all as specified and directed.
M&L for 15mm thick plastering in CM (1:6) on other than fair faces of brick work or concrete surfaces of internal wall etc finished even and fair without using extra cement complete all as specified and directed.
M&L for prepration of New Plaster/ untreated surfaces of wall and applying three coat of white wash complete all as specified and directed.
Complete removing exting treatment from plastered / unplaster surfaces of wall and prepration of scraped surfaces and applying Two coat of cement base paint on old decorated surfaces of walls complete all as specified and directed.
M&L for prepration of New plaster surfaces of wall and applying two coat of cement base paint complete all as specified and directed.
Preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer.
S&F Collapsible steel gates, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc as specified, erected in position and securing runners with holdfasts and brackets M.S Section of Collapsible steel gates shall be provided all as specified in S.S.R Part I- 2009 clause 10.24 Complete all as specified and directed
S&F M.S framed work such as grills, gratings, etc.. With ends of bars shouldered and riveted, or forged into spikes, framed guard bars, barred iron doors ladders, framed balusters, walk ways, railings, framework of water tanks and similar work con-forming to Fe. 290. Gde-E-165. Note (ii) :- Work will be carried out upto 6 story in necessary scafolding and safety measures and labour insourance etc complete.
S&F mild steel work as in Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates Fe 290 or E-165 complete all as specified.
S&F M.S Framed brackets work of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 (Brackets over 10 kg each to be measured under 'Structural Steel').
S&F Mild steel screw 11 to 15 mm dia bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut length of balt ecx 15 cm but n exc 22.5 cm, all as specified & directed.
M&L for Reinforced Cement Concrete (Nominal Mix) type B1 1:2:4 (20 mm graded Agg) in Columns, pillars, piers, posts and struts complete all as specified and directed.
M&L for Mild steel TMT bars 10 mm dia and over , cut to length, bent to shape required, including cranking, bending spi-rally for hooping for col-umns, hooking ends and binding with and in-cluding mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality con-forming to De-formed or twisted bars complete all as specified and directed.
M&L for Formwork for Formwork to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and directed
M&L for 30 mm thick flush shutters, solid core construction, exterior grade with block board core and plywood face, pannels, commercial type on both sides including provision of suitable blocks for taking mortice locks, latches or other fittings complete all as specified and directed.
M&L for preparation of new or previously untreated wooden surfaces exceeding 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed
S&F for Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering, fixed with self tapping screws as complete all as specified and directed
M&L Machine cut kota stone slab flooring 20-25mm thick over and including 15 mm thick cement screed bed in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed
S&F powder coated aluminium sliding window two track with two glass shutters using 4.8/5.0mm thick black/transparent glass , aluminium powder coated section aluminium cleat, PVC track, bearing, handle locking arangement, rubber beading etc complte fittings as approved. Note Size of aluminium section shall be under :- (i)Two track top and vertical - Jindal main-2010 section No 20829 or equivalent as appoved by GE (ii) Two track bottom- Jindal main-2010 section No 20830 or equivalent as appoved by GE (iii) Shutter vertical section- Jindal main- 2010 Section 20606 or equivalent as appoved by GE (iv) Shutter top and bottom - Jindal Main-2010 Section 20604 or equivalent as appoved by GE (v) Shutter vertical middle (interlock) -Jindal Main-2010 section 20605 or equivalent as appoved by GE
S&F PVC (SWR) pipe 110 mm bore, single socketed, in any length with rubber ring joints and jointed with approved adhesive and fixed to wall complete all as specified and directed.
S&F PVC (SWR) bend 110mm dia , any radius as required and jointed with approved adhesive complete all as specified and directed.
S&F PVC (SWR) junction single (Single T) equal or un equal 110mm dia , any radius as required and jointed with approved adhesive complete all as specified and directed.
Demolition of brick or stone masonry built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stone works and precast concrete articles, complete all as specified and directed
M&L for prepration of New plaster surfaces of wall and applying two coat of oil bound distemper with and including over a coat alkali primer old 1mm thick wall care putty complete all as specified and directed.
Material & Labour for prepration of new plaster surfaces of wall and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over 3 mm thick in two coat of water proof wall care putty complete all as specified and directed.
Material & Labour for complete removing existing old treatment from wall and prepration of new/ scrapped plaster surfaces of wall and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over a coat of water proof wall care putty complete all as specified and directed.
M&L for glazed coloured ceramic tiles, first quality (or approved class, colour and design/shade) of size 300x200x7/300x450x7mm thick in vertical surfaces, as in dado/skirting etc set & jointed in neat cement slurry & pointed in coloured cement to match with coloured tiles, over and including 10mm thick rendering in cement mortar 1:4 rough finish to receive the tiles with and including dismantling floor , hearth or wall tiling including cement mortar bedding (but not backing), removing debrish and rubbish off the premises and stacking serviceable tilescomplete all as specified and directed.
M & L Granite stone slab (of any type) work (table rubbed and polished) 20 mm thick in steps, jambs, pillars, window-cills, cooking platforms and like in over and including screed bed 15 mm thick in cement mortar (1:6) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, etc complete all as specified and directed
M&L for complete removal of existing treatement by scraping, washing, rubbing down or stopping distempered or painted surfaces etc of walls plastered or un-plastered & removing all vegetation growth, cleaning & applying of Birla/JK white wall putty approx 1 mm thick as per manufacturer's instruction on existing prepared surface and make the surface smooth by rubbing with sand papers etc and applying two coats of oil emulsion distemper over a coat of alkali primer complete all as specified and directed.
S&F powder coated aluminium frame for doors, windows or partition including aluminium beading, hinges of required size,jointing cleats, screws, dash,fastners,plug for fixing with wall, columns etc complete all as specified.
S&F powder coated of colour aluminium door shutters, Anodised aluminium door shutters, aluminium section weighing not less than 0.55 kg/Rm including necessary joining cleats, glazing clips, ruber neoprene packing,handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified. (panels likes prelaminated particle board / sheet glass shall be measured and paid seprately)
M&L for 4.8 mm thick sheet glass ordinary quality in panes exc 0.50 sqm each fixed with & including rubber gasket in aluminium frame work complete all as specified and directed.
M&L for suspended false ceiling system using chicago metallic (E grid)exposed supended system, grid section size 600mm X 600mm comprising of GI powder coated Main Runner of dimensions 39 mm X 24mm X 0.8mm thick (thickness comprising of GI/0.4+ PPPCGS/0.3mm & weight of runner 1.35 kg for 3600mm length) Cross Tee of dimensions 29mm X24mmX0.8mm thick and thick wall angle 22.2mmX22.2mmX 0.65 mm thick ( thickness comprising of GI/0.35+ PPPCGS/0.3mm & weight of angle 0.70 kg for 3050mm length)with and including 6 mm thick HPSC(High pressure steam cured) pre-primed , self embossed . textured designer board, water resistant termite resistant , fire resistant for insulation and acoustic purpose to be placed in the grid system duly suspended with 4mm dia GI bar hangers fixed with steel dash through fasteners from purlins of the roof with butterfly clips(Wt-0.007 Kg/clip)hold down clips (Wt-0.0035 Kg/clip) with Provn of light fixture with and including dismantling of wall and ceiling boards any thickness including cover filletscomplete all as specified and directed.complete all as directed. Make :- EVEREST or other equivalent as approved.
Taking down chowkats or frames with shutter (without taking off shutters from the frame) n. exc. 1.50 sqm each including removing to store complete all as specified and directed.
S&F powder coated 3 track aluminium sliding window three track with two glass shutters using 4 mm thick glass tinted modi guard (black/transparent) and one shutter with stainless steel wire gauge wire cloth 0.31 mm stainless steel wire gauge wire cloth 0.31 mm nominal dia of wire and width of aperature 1.61 mm using aluminium powder coated section aluminium cleat, PVC track, beading handle, lock, rubber beading etc complete fittings as per manufacture instructions Note:- Size of aluminium section are as under:- (i) Three track top and vertical - Jindal main 2010 section No 20621 or equivalent as approved by GE (ii) Three track bottom- Jindal main - 2010 section No 20620 or equivalent as approved by GE (iii) Shtter vertical section- Jindal main 2010- section No 20606 or equivalent as approved by GE (iv) Shutter top and bottom- Jindal Main- 2010 Section 20604 or equivalent as approved by GE (v) shutter verticle middle ( Interlock) - Jindal main - Section or equivalent approved by GE.
S&F 18mm to 20mm thick solid factory made PVC board for cup board /cabinate shutter with one side 1mm thick printed pvc sheet other side plain pvc sheet suitable fixed with &including suitable pvc frame, matching colured beading to cover all edges & screwed portion of frame, Magnetic catcher as per specification & drawing complete all as specified & directed.
S&F continuous (piano) hinges, mild steel, bright finish or electrogalvanised with width of flap (when open) 30 mm complete all as specified and directed.
S&F rotational moulded polyethylene water storage tanks 10000 ltr capacity (cylindrical vertical with closed top) hoisted with and including 20 mm dia ball brass valves, high pressure with polythene float and fly nut complete screwed for iron pipe or for brass ferrule and fixed in position all as per SSR Part I complete all as specified & directed.
Supply, installation, commissioning and testing monoblock pumping set of capacity 5 HP with complete fitting like pump, motor, base frame made out of MS channel nut bolts, applying two coat of synthetic enamel paint over a coat of red oxide prime complete all as specified and directed
Supply and fix DOL starter 5 HP, 3 phase 415 volts complete with all accessories all as specified and directed by Engr-In-Charge.
Supply and laying PVC insulated and PVC sheathed XLPE power aluminium cable of size 16 sqmm 4 core 1.1 KV grade including connections with thimble etc complete all as specified and directed
M&L for 50mm bore medium grade steel water tubing, galvanized (ISI Marked) with and including all fittings (ISI Marked) and jointed, tested and fixed complete to wall and ceiling / trenches or laid in floors etc complete complete all as directed.
M&L for 65mm bore medium grade steel water tubing, galvanized (ISI Marked) with and including all fittings (ISI Marked) and jointed, tested and fixed complete to wall and ceiling / trenches or laid in floors etc complete all as specified and directed
M&L for 25mm bore medium grade steel water tubing, galvanized (ISI Marked) with and including all fittings (ISI Marked) and jointed, tested and fixed complete to wall and ceiling / trenches or laid in floors etc complete all as specified and directed
M&L for 20mm bore medium grade steel water tubing, galvanized (ISI Marked) with and including all fittings (ISI Marked) and jointed, tested and fixed complete to wall and ceiling or laid in floors etc complete including taking up or down existing steel tubing pipe complete all as directed.
M&L for 15mm bore medium grade steel water tubing, galvanized (ISI Marked) with and including all fittings (ISI Marked) and jointed, tested and fixed complete to wall and ceiling or laid in floors etc complete including taking up or down existing steel tubing pipe complete all as directed.
Providing and fixing chromium plated brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms of size 15 mm nominal bore complete all as specified and directed by Engr-In-Charge.
Providing and fixing gun metal gate valve with CI wheel of approved quality (screwed end) size 25 mm nominal bore complete all as specified and directed by Engr-In-Charge.
Providing and fixing gun metal gate valve with CI wheel of approved quality (screwed end) size 50 mm nominal bore complete all as specified and directed by Engr-In-Charge.
Making connection of GI distribution branch with GI main of sizes 40 to 50/50 to 80 mm by providing and fixing tee including cutting and threading the pipe etc complete all as specified and directed by Engr-In-Charge.
Excavation in over areas in any type of soil not exceeding 30 cm deep and exceeding 1.5 mtr width and getting out soil including forming bottom surface to required slope/gradient for laying cables/pipes etc. including removing cable protection covers/ bricks complete all as specified and directed. Notes : (i) Excavation shall be made carefully in order to avoid damage of existing cables and brick protection. (ii) The excavation work may be carried out in short lengths for locating fault in under ground cables at different locations
Excavation in trenches in any type of soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width and getting out soil including forming bottom surface to required slope/gradient for laying cables/pipes etc. including removing cable protection covers/ bricks complete all as specified and directed. Notes : (i) Excavation shall be made carefully in order to avoid damage of existing cables and brick protection. (ii) The excavation work may be carried out in short lengths for locating fault in under ground cables at different locations
M&L for Returning, filling in, including spreading leveling, watering and well ramming the excavated soil in layers not exceeding 25 cm thick complete all as specified and directed.
M&L for Removal of surplus excavated soil to a distance not exceeding 50 Mtr distance and depositing as directed at a level not exceeding 1.5 mtr above starting point complete all as specified and directed.
Material & labour for sand filling with clean dry fine sand unwashed including gently punning around cables in trenches/ducts for cable protection complete all as specified and directed (NOTE : Thickness after punning shall be measured for payment)
M&L for PCC 1:4:8 type D-2, using 40 mm graded stone agg as in foundation, filling, mass concrete and sub base of floor complete all as specified and directed
M&L for PCC 1:2:4 Type B-1 {using 20mm graded crushed stone aggregate} as in coping/benching bed plates roof kerbs mud stops, including weathering, slightly rounded or chamfered angles and throating etc including necessary form work including demolition of existing cement concrete of any description complete all as specified and directed.
Taking down of carefully unserviceable Aluminium/copper point wiring (light, fan socket or power) complete with fitting such as switches, ceiling rose lamp holder, sockets, fan regulators, SK/FTL light fittings etc removing materials for store for keeping in safe custody or for taking credit (credit for above items should be taken as per conditions separately) and making good disturbed surfaces of walls, floors etc as specified and directed.
Supplying, fixing & testing in replacement UNSV recess mounting in built ,36 Watts,2'x2' LED ceiling light fitting with slim line extruded aluminium/ CRCA body, opal acrylic diffuser, electronic driver etc and all accessories pre wired including connecting to source complete all as specified & directed. Make- C&G or equivalent in Phillips/Havells/Crompton as approved.
M&L for point wiring with single core PVC insulated unsheathed 1100 volt grade FRLS-IS 694 cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through and including non metallic rigid PVC conduit medium duty ISI marked not less than 20mm dia, concealed conduit wiring in walls and surface with GI saddles GI screws, rawal plugs in ceiling or roof if not possible including Tee, Junction boxes and provision of flush metal boxes, inner and outer plate suitable for modular switch, socket and fan regulator as per site requirement and drawing continuous earth wire with and including PVC insulated unsheathed 1100 Volts grade FRLS-IS 694 cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) and connected to main earth dolly complete all as specified for one light/Fan point controlled by one Switch. Make: Havells/Polycab/Gloster. Make of conduit: Jindal/Finolex/AKG
All as per Srl item No 1 above for point wiring for 5 pin switch socket outlet, 5/6 Amps on same board with other switches complete all as specified and directed.
All as per Srl item No 1 above for point wiring for 5 pin switch socket outlet, 5/6 Amps on independent board complete all as specified and directed.
All as per item No 1 above for one power point 3 pin 15 Amps socket out let PVC insulated unsheathed 1100 volt grade cable with stranded copper conductor of size 2.5 Sq mm (Nominal area) including earth wire PVC insulated unsheathed 1100 volt grade cable with stranded copper conductor of size 2.5 Sq mm (Nominal area)cable common connected to earth dolly, all as specified for one 3 pin 15 amps socket outlet point controlled by one switch complete all as specified and directed Make of cable and conduit: Havells/Polycab/Gloster.
S&F Modular switch single pole one way 6 amp complete. Make -Legrand / Anchor Penta/ Havells as approved.
S&F Modular switch single pole one way 16 amp complete. Make - Legrand / Anchor Penta / Havells as approved.
S&F Modular socket outlet 2/3 pin combined 2 module 6/16 amp complete. Make -Legrand / Anchor Penta / Havells as approved.
S&F Modular socket outlet 2/3 pin combined 2 module 6 amp complete. Make -Legrand / Anchor Penta / Havells as approved.
S&F ceiling rose 3 plates polycarbonate, isolated body complete. Make - Legrand / Anchor Penta / Havells as approved.
S&F modular fan step regulator 120 W 2 module complete. Make: Legrand / Anchor Penta / Havells as approved.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC)
S&F LED tube light fitting batten with universal batten fitting suitable for single T8 LED lamps complete all as specified and directed. Make:Crompton or euivalent in Philips/ Havells
S&F LED tube light 16 Watt T8 double sided connection with built-in driver, THD not more than 10% all as per Crompton or equivalent in philips/Havells as approved.
S&F in replacement of UNSV bulkhead fitting with integrated LED bulk head fitting 600 lumens, 6000 K comprises of pressure die cast housing, acrylic diffuser and frame IP 65 protection, IK-07 etc including connection complete all as directed. Make- LBHP-10-CDL of C&G or equivalent in Havells/Phillips as approved.
S&F MCB distribution board powder coated, CRCA steel sheet constructed as per IS : 8623, degree of protection IP 43 - IK 09 with metal door, recess mounted, having insulated 200 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required with rating DB 4 Way 240 volt single door complete all as specified and directed.
Supply and fixing MCB SP 240 volts 'C' Curve suitable for fixing in DB of capacity 6 to 32 Amps complete, all as specified.
Supply and laying PVC insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area of size 6 sqmm 2 Core complete all as specified and directed.
S & F in replacement of unserviceable MCB SPN 240 volts 'C' Curve suitable for fixing in MCB DB of capacity 32 amps complete all as specified and directed.
S&F exhaust fans made of steel body AC single phase 230 V copper wounded of size 300 mm sweep with louver shutter complete with and including cutting holes into or through brick/stone/concerete wall built in cement mortar of suitable size and making good in cement mortar 1:3 or cement concerete 1:2:4 type B1 using 20mm graded stone aggregate as required and applying finishes as per existing for mounting the exhaust fans and making good the disturbed surfaces complete all as specified and directed. Make: Havells/CG/Bajaj.
S&F exhaust fans made up of sturdy engineering plastic AC single phase 230V copper wounded of size 250 mm sweep with louver complete with and including cutting holes into or through brick/stone/concerete wall built in cement mortar of suitable size and making good in cement mortar 1:3 or cement concerete 1:2:4 type B1 using 20mm graded stone aggregate as required and applying finishes as per existing for mounting the exhaust fans and making good the disturbed surfaces complete all as specified and directed. Make: Havells/CG/Bajaj.
Gaur Construction Co
M/S Construction Solutions
M/S Anil kumar
M/S P K ARORA
JS CONSTRUCTION COMPANY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .