Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.4 LAccepted-AOC 58 MODERN MARKET NEAR AMBER CINEMA JAMNAGAR | JAMNAGAR | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹26.2 L+₹1.1 L (4.18%)Rejected-Finance | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹26.5 L+₹1.4 L (5.47%)Rejected-Finance 00 CHAH KATHAUTI CHAH KATHAUTI MATHURA UTTAR PRADESH 281001 | MATHURA | UTTAR PRADESH | 281001 | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹26.9 L+₹1.7 L (6.85%)Rejected-Finance PARTH B 203 PATEL COLONY STREET NO 11 ROAD NO 3 JAMNAGAR 361 006 GUJARAT | JAMNAGAR | GUJARAT | 361006 | L4 | Rejected-Finance Not Being L1 | |
| 5 | L5₹28.1 L+₹2.9 L (11.5%)Rejected-Finance | L5 | Rejected-Finance Not Being L1 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
20 Jul 2022, 6:00 pmClosed
GE (I) Navy Jamnagar
INS Valsura, Jamnagar - 361150
Repair, replacement and maintenance of Water Heaters (Solar, Geysers) and Ventilation Equipment such Ceiling Exhaust Fans etc and connected items under GE (I) Navy Jamnagar
2022_MES_533740_1
8603
Open Tender
Electrical and Maintenance Works
Item Rate
300 days
GE (I) Navy Jamnagar
Please refer tender documents
6 documents required · 6 mandatory
₹500
GE (I) Navy Jamnagar
₹50,000
Yes
14 Feb 2023
25 Jun 2022
22 Jul 2022
25 Jun 2022
20 Jul 2022
15 Jul 2022
25 Jun 2022 - 14 Jul 2022
Amount
Taking down carefully ceiling fans / exhaust fans from any height and of any make and sweep including disconnecting the cable from ceiling rose and deposited to MES store for servicing, greasing & oiling, replacing the split pin, unserviceable nut, bolt, etc. and refixing the same after servicing with necessary connection complete all as specified and as directed.
Taking out carefully unserviceable shaft bush and S&F new shaft bush of existing type/ model for ceiling fans & exhaust fans complete all as specified and as directed.
Taking out carefully unserviceable ball bearing of any type/ size and S&F new ball bearing suitable for any type/ size ceiling fans & exhaust fans as per the existing standard complete all as specified and as directed.
Taking out existing unserviceable fan condenser/ capicitor of any size/ make and S&F connecting new fan condenser/ capacitor 2.0 to 2.5 mfd complete all as specified and as directed. Make: Havells/ Usha/ Siemens
Taking out existing unserviceable fan condenser/ capicitor of any size/ make and S&F connecting new fan condenser/ capacitor 3.15/ 4.0 mfd complete all as specified and as directed. Make: Havells/ Usha/ Siemens
S&F in repairs step type fan regulator 100 W, 2 module, AC, 230V, electronic complete all as specified and directed. Make: Legrand Cat No: 6755 30 / Indo Asian / Havells / Crabtree
S&F in repairs step type fan regulator AC, 230V, electronic on the existing phenolic laminated sheet etc complete all as specified and directed. Make: Anchor / Legrand / Havells / Crabtree / Indo Asian.
S&F in repairs step type fan regulator 100W, 1 module, AC, 230V, electronic complete all as specified and directed. Make: Legrand Cat No: 6755 31 / Indo Asian / Havells / Crabtree
Taking out carefully damaged/ worn out rubber real and S&F new rubber reel of existing size & shape complete all as specified and as directed.
Taking out carefully damaged/ worn out MS clamp and S&F new MS clamps with necessary nuts, bolts, washers, locking pins etc of existing size & shape complete all as specified and as directed.
Dismantling 1200 mm sweep ceiling fan motor of any make, removing old burnt winding wire, cleaning the armature throughty and replacing the sme with new enamelled copper wire of adequate size/gauge including class B insulation, varnishing heating etc, reassembling, resting refixing and connecting complete all as specified and as specified.
All as per Item No. 11 here in above, but for 1400 mm sweep ceiling fan motor.
All as per Item No. 11 here in above, but for 450 mm sweep exhaust fan motor.
All as per Item No. 11 here in above, but for 300 mm sweep exhaust fan motor.
All as per Item No. 11 here in above, but for 250 mm sweep exhaust fan motor.
Taking down existing Exaust fan and S&F new 450 mm sweep exhaust fans metal body AC single phase 230/240 V with lower shutter venti Air complete all as directed. Make: Bajaj Supreme Dlx 450mm 900 rpm 1ph Ind Ex fan or equivalent in USHA/ Khaitan/ Crompton Greaves
Taking down existing Exaust fan and S&F new 300 mm sweep exhaust fans metal body AC single phase 230/240 V with lower shutter venti Air complete all as directed. Make: Bajaj Supreme Dlx 300mm 900 rpm Ind ex fan or equivalent in USHA/ Khaitan/ Crompton Greaves
Taking down existing Exaust fan and S&F new 250 mm sweep exhaust fans PVC body AC single phase 230/240 V with lower shutter venti Air complete all as directed. Make: Bajaj Maxima DX Fresh Air 250 mm White EX fan or equivalent in USHA/ Khaitan/ Crompton Greaves/ Havells
Taking down existing Exaust fan and S&F new 200 mm sweep exhaust fans PVC body AC single phase 230/240 V with lower shutter venti Air complete all as directed. Make: Bajaj Maxima DX Fresh Air 200mm White EX Fan or equivalent in USHA/ Khaitan/ Crompton Greaves/ Havells Note for item No. 16 to 19: Old Exhaust fan shall be deposited in the AGE E/M store yard.
Supply only 1200 mm sweep, 3 Star Rating ceiling fans 230 V with all accessories suitable size for down rod complete all as specified. Make: Bajaj Sabse Tezz EE 03 White C/F or equivalent in USHA/ Khaitan/ Crompton Greaves /Havells
Supply only 1400 mm sweep, 3 Star Rating ceiling fans 230 V with all accessories suitable size for down rod complete all as specified. Make: Bajaj Sabse Tezz EE 03 White C/F or equivalent in USHA/ Khaitan/ Crompton Greaves /Havells
Supply only BEE 5 Star rating (BLDC) Brushlesh direct current motor Ceiling Fan 1200 mm sweep, comlete down rod and 3 core 1.5 sqmm copper conductor cable from ceiling rose to fan complete with all accessories an suitable size for down rod 230 V complete. Make: Havells Model No. Efficiencia Neo (BLDC26W) or equivalent in USHA/ Khaitan/ Crompton Greaves /Bajaj
Taking down existing Water Heater and S&F new Electric Water Heater 5 Star rating, glass line inner tank, plastic outer body, PUF insulation of 25 litre storage capacity, operating on single phase 230V, AC supply complete all as specified and as directed. Make: Bajaj Celenta (m) 25 L Cat No. 150801 or equivalent in Jaquar/ Recold / Havelles Note: Old Water Heater shall be deposited in the AGE E/M store yard.
M&L for DOs/Don't instructions for Electric geysers as per E-in-C's branch letter Instructions, printed on PVC plastic coated paper self adhesive shall be pasted on geyser.
Taking down geyser of any capacity, horizontal / vertical type after properly disconnecting from water supply lines i.e. inlet/outlet and electric supply connections and reconnecting/ refixing the same in original position after necessary repairing complete all as specified and as directed. Note: Repair works and Spare parts shall be measured and paid separately.
Taking out existing unserviceable flexible cable of any size S&F new copper flexible cable 3 core PVC insulated of size 40/0.0076 for geyser complete all as specified and as directed.
Taking out existing unserviceable indicator lamp and S&F new indicator lamp (Neon lamp) round / square in red / green / blue as required of standard make for geysers complete all as specified and as directed.
Taking out existing unserviceable thermostat switch of any model/ make and S&F thermostat switch of as per existing make/ model for 50/25 ltr capacity geysers complete all as specified and as directed.
Taking out existing unserviceable heating element and S&F new heating elements 1000 W capacity and neoprene rubber washer ISI marked for vertical/ horizontal type geysers of 50/25 Ltrs capacity complete all as specified and as directed.
All as per Item No. 29 above, here in but heating elements 1500 W capacity.
All as per Item No. 29 above, here in but heating elements 2000 W capacity.
All as per Item No. 29 above, here in but heating elements 3000 W capacity.
Taking out existing unserviceable PVC connection pipe and S&F new PVC connection pipe heavy duty size 15 mm dia, 450 mm long as per the site requirement length with brass adopter/ union washer both sides suitable for hot water supply complete all as specified and as directed.
Taking out existing unserviceable non return valve and S&F new 15 mm dia Non Return Valve, lSl marked for vertical / horizontal geysers complete all as specified and as directed
S&F in repairs plug top 3 pin, 15/ 16 Amps capacity, lSl marked complete all as specified and as directed.
S&F in repair single pole enclosure with a two pin and earth plug and socket 240V with one single pole MCB 20Amp complete all as specified and as directed.
Taking down old existing sub main wiring and M&L for sub main wiring with 2 run single core 4 Sq.mm PVC insulated unsheathed copper multistranded conductor 1100 Volts grade drawing into and including PVC heavy duty casing and capping with PVC coated copper earth conductor 4 Sq.mm one run complete. Note: 2 run of 4 Sq.mm cable one run 4 Sq.mm PVC insulated cable copper multistranded conductor alongwith PVC cassing capping will be measured as one unit.
Taking out existing flow unit and S&F new flow unit/ siphon assembly including outlet and thermostat pipes with drain plug and screw for fixing the elements inclusive of clamps for holding the element with nuts & bolts complete all as specified and as directed.
Taking down solar water heater of any capacity, horizontal/ vertical type after properly disconnecting from water supply lines i.e. inlet/ outlet and electric supply connections and reconnecting/ refixing the same in original position after repair complete all as specified and as directed. Note: Repair work and spare parts shall be measured and paid separately.
M&L for servicing parts of TATA solar water heater of 100 Ltr capacity evacuated tube collector, make and model
M&L for servicing parts of TATA solar water heater of 200 / 300 Ltr capacity evacuated tube collector, make and model
M&L for servicing parts of TATA solar water heater of 100 / 300 Ltr capacity copper collector based chemical wash for collector.
S&F Silicon rubber, O ring with coupler set for 100/200 Ltr capacity solar water heater
S&F CPVC pipe SDR 11 having outer dia 15 mm pipe with plain CPVC SDR 11 fitting such as bends, elbows, unions and end pieces to receive the fittings and fixed with solvent cement in walls/ceilings (concealed/surface) or laying in floors complete all as specified
All as per Item No.44 here in above, but 20 mm outer dia pipe.
All as per Item No.44 here in above, but 25 mm outer dia pipe.
S&F Evacuated Solar Tube of minimum size 1800 mm x 58 mm complete all as specified. Make: Tata BP solar or equivalent make
M&L for Mild steel angle Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated and inclusive of one primer coat, one under aluminium coat and one aluminium finishing coat of paint complete all as specified.
S&F in repairs 20 mm bore stop valve, cast copper alloy, screwed down, high pressure with crutch or butterfly handle screwed both ends ISI marked for iron pipe or for unions and fixed complete all as specified and as directed.
S&F in repairs 25 mm bore stop valve, cast copper alloy, screwed down, high pressure with crutch or butterfly handle screwed both ends ISI marked for iron pipe or for unions and fixed complete all as specified and as directed.
Fixing/ shifing only electric water heater of any capacity/ type from one place to required place as per user requirement including dismantling, transportation, fixing arrangement with new foundation bolts in existing wall of any type including PVC connection complete all as specified and as directed. Note: PVC connection shall be measured and paid under relevent item.
M&L glass wool in 40-80 mm thick sheet yellow/ white colour, suitable for insulation of water heaters complete all as specified.
M&L for GI tubing 15 mm bore medium grade duly drilled with two Nos. of M8/M10 bolts of required length for hanging of ceiling fans complete all as specified.
S&F in repair canopy for ceiling fan as required at site as per size/ sample and as directed by Engr-in-Charge.
Cutting opening, through RR masonry / brick walls for fixing exhaust fan of required size (Square/Round) up to 450 mm sweep and making good disturbed surfaces of wall of required size with CM 1:4 and painting with two coats of existing colour to match the wall complete all as specified and as directed.
M&L for making arrangements for Fan hook of standard type as per SSR specification including cutting RCC slabs to the required depth upto existing MS bars tie up with new one and making good disturbed surfaces complete all as specified and as directed.
S&F in repair hose pipe suitable for hot water heater temp 70ºC of solar water heater of required 20mm size and as per required length at size.
S&F in repairs louvers/ wire mesh bracket / PVC ready made Mesh to prevent bird entry suitable for 450mm sweep Exhaust fans.
All as per Item No. 58 above, here in above but for 300mm sweep Exhaust fans.
All as per Item No. 58 above, here in above but for 250mm sweep Exhaust fans.
S&F in repair anti vibrating shoes suitable for exhaust fans of of any size/ type complete.
S&F PVC clamp suitable for capacitor of any size of ceiling fan complete.
S&F down rod made out GI tupbing ize 15mm and 600mm long including drilling, tapping, screwing and locking pin complete suitable for ceiling fan of any type.
S t modi
1R K Traders
M/s Balaji Enterprise
rajengineers
J J ENTERPRISE
M/s.Bhavin Electricals
M/s Jagdish Machinery Stores
JAMNAGAR ELECTRIC AND MACHINERY CO
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .