| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.2 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹5.3 L+₹11,870 (2.27%)Rejected-Finance | L2 | Rejected-Finance L2 |
Tender Value
₹6.4 L
EMD Value
₹16,087
Closing Date
25 Feb 2025, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
Executive Engineer Main office Thiruvananthapuram Corporation
ELECTRIFICATION OF TAKE A BREAK BUILDING IN PALLITHURA WARD, Thiruvananthapuram Municipal Corporation
2025_LSGD_738994_2
29/E16/1626088/24/Tender
Open Tender
Electrical Works
Item Rate
120 days
Thiruvananthapuram Corporation
Please refer Tender documents.
9 documents required · 9 mandatory
₹1,420
Yes
₹16,087
Yes
16 May 2025
17 Feb 2025
28 Feb 2025
17 Feb 2025
25 Feb 2025
17 Feb 2025
Amount
1.10.1Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mmFRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVCconduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group A
1.10.2Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mmFRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVCconduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group B
1.14.1 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire
1.24.1 Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. as required.5/6amps switch
1.24.3 Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. as required.15/16 amp switch
1.24.4 Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
1.24.5 Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
90.10.3.15 Supply and Fixing the following modular switches & accessories in the existing frontplates and giving necessary connections as required (RoHS compliant )32A DPswitch with indicator
90.10.3.33 Supply and Fixing the following modular switches & accessories in the existing frontplates and giving necessary connections as required (RoHS compliant )25A 3pinShuttered socket
1.25 Supplying and fixing two module stepped type electronic fan regulator on the existingmodular plate switch box including connections but excluding modular plate etc. as required.
1.27.1 Supplying and fixing following size/ modules, GI box alongwith modular base &cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
1.27.2 Supplying and fixing following size/ modules, GI box alongwith modular base &cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
1.33 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ woodenblock including connection etc as required.
1.56Supplying and fixing suitable size Gl box with modular plate and cover in front onsurface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socketoutlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For lightplugs to be used in non residential buildings).
1.58 Supplying and fixing PVC batten/ angle holder including connection etc. as required.
OD355104/2022-2023Supply and providing the following types and power rated lamps in the existingfittings as required B22LED bulb 10 W
od1761805/2022_2023 Supplying and fixing cast aluminium bulk head fitting with mesh guard with 7W LED bulb and giving connection etc. as required
OD173618/2024-2025Supply of 6W mirror lamp including necessary accessories
OD173620/2024-2025 Supply of Wall Lamp suitable for B22 lamp
1.55.1Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bellpoint ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copperconductor single core cable in surface/ recessed PVC conduit, and earthing the pointwith 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. asrequired.Group A
90.15.4.5Supply Conveyance, installation, testing and commissioning of 40W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip makeCree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should beseperatly accessible for maintenance (LM 79&80 certificates from NABLaccredited Third party lab to be produced mentioning chip manufacturer)
90.4.2Supply and installation of suitable size MS belt type fan clamp fabricated from flatiron 40 x 6 mm, 150mm long x 2 Nos with M.S. rod bent to shape, neatly painted with 2 coats of enamel paint over a coat of red oxide primer as per IS 732 as required.
90.4.5.4Supply, Installation, testing and commissioning of ceiling fan of following sizesincluding wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.1200mm sweep - ceiling fan complete with service value minimum 4.0(cubmeter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper windingsuitable for 230V/240V single phase AC supply
90.4.8Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep includingplastering colour washing etc. as required.
90.4.10Conveyance, installation , testing and commissioning of exhaust fans of size up to 450mm in the existingopening, fixing necessary anchor bolts / bolt and nuts etc., as required including giving connections with the supplied wire along with the exhaust fan.
od1753373/2022_2023 Supply of 300/305mm sweep 1400 RPM heavy duty exhaust fan working on 230 V A/C in metal frame including all accessories as required (PWD approved make)
od1761898/2023_2024 Supply of 450mm sweep wall mounting metal type fan with minimum noise (PWD approved make)
90.4.6 Conveyance, installation, testing and commissioning of wall mounting fans of all types using mounting brackets supplied along with the fan.
OD355325/2022-2023 Supplyof 3W round LED surface mounted light fitting including all accessories.
OD355070/2023-2024 Supplyof18W LEDrecessed light greater than110 lumen/watt, 4500-6000K havingCRI greater than 70% including all accessories as required.(Philips/Havells/PWDapproved make with ISI)
od1762284/2022_2023Supply of 12 W LED Ornamental type double side Lamp suitable for 230 V AC.(PWD approvedmake)
MR Supply of 12W watts Garden /Bollard light with Aluminium die cast body having IP 65 rated suitable for outdoor use AC 140-265 V having uniformly lit diffuser at the upper portion and making necessary connection as required.
OD57288/2024-2025 Supply and providing led strip of required colour light including accessories asrequired.
90.3.12Conveyance and fixing charges of recess mounting down light fittings of all typescomplete with all accessories in the existing opening of false ceiling, givingconnections with the existing wire etc., as required.
90.3.14Conveyance, installation, testing and commissioning of foot light fittings / skirt light of all types directly onwall including cutting necessary holes, giving connections with the extended orginal wiring, making good the damgaes, colour washing etc as required.
90.15.4.5Supply Conveyance, installation, testing and commissioning of 10W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 65 protection with power factor greater than 0.95 at full load, internal surgeprotection up to 5 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than10%, power factor greater than 0.98, RoHScompliant, duly wired up for use on 230 V AC supply.
1.17.3 Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X1.5 sq.mm
1.17.12 Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x2.5 sq. mm
1.17.21Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x4 sq. mm
1.21.1Supplying and fixing of following sizes of medium class PVC conduit along withaccessories in surface/ recess including cutting the wall and making good the same incase of recessed conduit as required.20 mm
1.53.1Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable
2.3.4Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator16 way, Double door
2.10.1 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.12.1 Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.14.2 Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
90.12.7.13Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armouredaluminium power cable, 1.1 KV grade of the following sizes using clamps notedalong with the cables, spacing of clamps not exceeding 60cms, making good thedamages , colour washing etc. as required.3 core 6 sq mm with factorymade clamp
90.12.5.12 Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3 core 4 sq mm
90.12.10.2 Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size
90.6.5.11Supply and drawing the following sizes of multi-core PVC insulated & FRLSPVC sheathed 650/1100 V grade copper conductor round flexible cables conformingto IS 694 part I 1960 in the existing surface / recess conduit as required includinggiving necessary connections of the following sizes.3 core 1.50 sq mm
5.4Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick includingaccessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt asrequired.
90.14.1.2Fabrication, supply, conveyance, installation testing and commissioning of floor orwall mounting, dust and vermin proof, cubicle type MV panel board comprising ofthe following components/ devices & complying to IS 8623.Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approveddesign and requirement, with front and rear access facility, bus bar chambers, hingeddoors for all switch gear compartments, earthing the doors using 4 sq mm braidedcopper conductor, providing necessary cut-outs for mounting meters, relays,indication lamps, bus bar interconnection etc, detachable covers for bus bar chamberand cable alley, powder coating the assembly after subjecting to 7 tank process etc asrequired. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted anglesetc shall not be used for the fabrication of panel assembly. The measurments will betaken the area of the complete sheets used for panel board including partitions,folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame)
90.16.1.3Supply and drawing bare earthing conductors of the following sizes along withwiring/ cables and giving connection as required3.15 mm copper conductor ( 10SWG)
90.16.5.3 Supply of superior quality copper earth socket for the following size of earthconductor including crimping etc. as required.3.15 mm (10 SWG)
od1761809/2022_2023 Supply and fixing 32A backelite fuse base with HRC fuse link in the existing meter board and giving connections etc
od1761810/20222023Supply and fixing 32A, 415 V, 2 way neutral link mounted on DMC/ SMC base in the existing meter boardand giving connections etc.
od1761813/20222023 Supply and providing iron hook for binding service wire
MR 2382 Supply and providing Fire Extinguisher-ABC 5 Kg Type
OD336921/2024-2025 Supply, Conveyance, Installation,Testing and commissioning of 1 No Sanitary Napkin Incinerator having capacity of 15 - 20 pads / cycle with cycle time of about 45 minute - 1 Hour and housing made out of CRCA steel of 1.2 mm thickness making necessary connections as required
Supply and fixing 6 TB Surveillance Hard Disk Drive for NVR(PWD approved make with ISI)
Supply and fixing 600 VA UPS
Supply and fixing CCTV Power Supply (8 Channel)
Supply and installation of high quality 16 channel NVR with HDMI and VGA out 2 SATA port for HDD supporting up to 6 TB on each. Ethernet 1 RJ-45 port (10/100/1000M) USB port ad supplied with necessary accessories.(PWD approved make with ISI)
Supply and Installation of high quality Dual stream Day and Night IR IP PoE Bullet/Dome Camera with 5MP image sensor ,30mtr of IR rage and with 3.6 mm Fixed lens. IP 66 (PWD approved make with ISI)
Supply and installation of 32 inches HD Ready LED TV with 2HDMI input,USB input etc supplied with all necessary accessories including wall mounting kits -1 year warranty (LG/Samsung/Sony)
Supply and fixing 6U Rack with PDU, hardware kit & cooling unit
Supply and fixing PA mixer amplifier with connectivity for 3 mic, 1 Aux input with built in MP3 player with remote control for USB,SD/MMC card reader,Bluetooth and FM including all accessories as required.(Ahuja SSB-80 DFM/PWD approved make with ISI)
Supply and fixing of 40watts 2-way wall speaker having 2 nos. 4" coated rubber surround woofers,1 dome tweeter and line matching transformer including accessories as required (Ahuja LCS-404T/PWD approved make with ISI)
HARIKUMAR V V (BID ID -2126393)
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1186873.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .