EXECUTIVE ENGINEER
Electrical Division HPPWD Palampur
Construction of Adarsh Gram Sukh Aashrya Parisar Village Luthan Tehsil Jawalamukhi Distt Kangra HP Sub Head Providing for Fire Alarm system in Admin in cum Recreational block Vocation Training block Occupants Quarters block Children Male block Chi
2025_PWD_119901_1
Elect. Division HPPWD Palampur
Open Tender
Electrical Works
Percentage
Jawalamukhi
Please refer Tender documents.
8 documents required · 8 mandatory
₹2,000
₹1.6 L
Yes
14 Nov 2025
7 Nov 2025
14 Nov 2025
7 Nov 2025
14 Nov 2025
7 Nov 2025
Admin in cum Recreational block :- Supply, Installation, Testing and Commissioning of intelligent analog addressable heat(static+ROR) with inbuilt turbo isotator and integral respose indicator with 360 degree viewing angle.Detector shall communicate 3 danger levels for differentiated alarm activation.Detector should have unique address of communication and assigned through panel with mounting base as required with the protection category of IP40 and duly approved by EN54/LPCB/VDS/FM (Make: Honeywell(Morley)/ bosch/ Siemens/ edwards/ simplex/Glyptic)
Supply, Installation, Testing and Commissioning of addressable multisensor smoke detector shall be with built in microprocessor and short circuit isolator capable including common mounting base plug in type and interchangeable with other smoke detector.The alarm LED shall be preferably 360 degree.The static voltage overload protection shall be inbuilt. etc. as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements; Drift Compensation feature & Automatic addressing. Detector should monitor Electromagnetic interference and report to the panel - current and average values.Detector should have IP rated EMC safety for detector shall be 50 V/m. Shall be UL/EN/VDS certification.The Detector shall be fully tested and each detector should bear the SI no and seal of the approving laboratory & complete in all respect. as requied. The panel shall have proper listing and approval from NFPA, UL,ULC, FM, CSFM,LPCB, VDS,BRE AND AS PER RELEVANT IS CODE (Make: Honeywell(Morley) bosch/ Siemens/ edwards/ simplex/Glyptic
Supplying, installing, testing and commissioning of Addressable Manual Call Point ( Break Glass Type). The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. The panel shall have proper listing and approval from NFPA, UL,ULC, FM, CSFM,LPCB, VDS,BRE AND AS PER RELEVANT IS CODE (Make: Honeywell(Morley) bosch/ Siemens/ edwards/ simplex
Supplying, installing, testing and commissioning Response indicator for all detectors located above false ceiling.The panel shall have proper listing and approval from NFPA, UL,ULC, FM, CSFM,LPCB, VDS,BRE AND AS PER RELEVANT IS CODE (Make: Honeywell(Morley) bosch/ Siemens/ edwards/ simplex)
Supplying, installing, testing and commissioning of Sounder cum Strobe rated at 80 dBA @ 3m for Audible annunciation and 115cd flashintg at 1 Hz for visual indication. The panel shall have proper listing and approval from NFPA, UL,ULC, FM, CSFM,LPCB, VDS,BRE AND AS PER RELEVANT IS CODE .(Make: Honeywell(Morley) bosch/ Siemens/ edwards/ simplex)
Supply, Installation, Testing and Commissioning of Microprocessor based Intelligent Addressable Main Fire Alarm Control Panel with Suitable Loops modules and each loop capable of supporting not less than 250 devices (detectors & modules should be in any combination) ; Loop length up to 1.5 km, 8" Color LCD touch screen display with bright colors to indicate alarms and events, 4 Nos of Integrated Ethernet Ports & 2 Nos of RS 485 for networking, 200 Nos of Soft programmable keys with status indicators for individual triggering of NAC Ouputs, evacuation speaker zones, AHU Modules, Damper switch, Smoke extraction Fans, Lifts.. etc. The Panel shall support 10000 history logs in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 24 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger.The panel should also have IP30 or better protection. The panel shall have seamless integration with EVAC certified Public Address System and shall be complete with all accessories . EN54 / Vds/UL Certification. Make: Autronica/ Honneywell (Morley)(Notifire) / Bosch
Supply, Installation, Testing and comissioning of single core multistrand 1.5 sq mm annealed copper conductor speaker cable in existing pipe/ channel I/C connection etc.Make Finolex/Polycab/ KEI
Supply and erection of 25 mm dia PVC conduit pipe ISI marked (Medium) recessed in wall /ceiling etc. including cost of PVC bends, inspection box and all other material required to complete the job in all respect to the entire satisfaction of Engineer-in-Charge of work. Make Diplast/Polyplast/BEC.
Supply, Installation, Testing and comissioning of Cabinet Speaker Max Power - 9 W ,Rated power (PHC) - 6 W(6-3-1.5), Sound pressure level at rate power /1 w ,(at1kHz,1m) (at 1 kHz, 1 m) - 96dB/ 90dB,Effective frequency range (-10 dB) - 200-15000 Hz,Opening angle (at 1 kHz/4 kHz, - 6 dB),In degrees - 150/70,Rated voltage - 100 V,Rated impedance - 1667 ..Make: Autronica/ Honneywell (Notifire) / Bosch
Supply, Installation, Testing and comissioning of 17U Equipment Rack with provision for housing all control equipment with front & rear door, Blower for cooling and proper locking arrangements and as per the specifications, complete in all respect upto the entire satisfaction of Engineer - in - Charge of the work. Makes: Valrack /Netrack/ Comrack
Supply, Installation, Testing and comissioning of 240 watts mixer amplifier Inbuilt Bluetooth for audio streaming supports audio playback from USB pen drive,4 microphone/line inputs,plus music source input,insert feature to use as a pre/power amplifier,optional 2 tone chime generation for input 1,frequency response 80 Hz to 18KHz (+1/3dB @ 10 dB ref. rated output),Distortion<1% @ rated output power , 1 KHz,Bass control-Max+- 8dB,Treble control-Max+- 8dB,connector-Clinch stereo converted to mono,Sensitivity-200mV to 300 mV, Impedance-22 Kohm,S/N(flat at max volume) >70dB, Headroom >25dB as required complete in all respects. Makes:-Beyerdynamic/Bosch/TOA/Brahler, Honeywell.
Supply of tabletop Unidirectional Condenser Microphone Voltage range 12 to 48 V current consumption <8mA,Sensitivity 0.7mV@85 dBSPL(2mV/Pa),Maximum input sound level 110dB SPL,Distortion<0.6% (Max input),Input noise level(equiv) 28 dB SPLA (S/N 66dBA Ref,1 Pa), frequency response 100 Hz to 16 KHz Output impedance 200 ohm as required complete in all respects. Makes:-Bosch/Sennheiser/Shure.
Supply, Installation, Testing and Commissioning of Glow Type EXIT Sign Board photo luminescent of size 300 mm x 250 mm x 1.5 mm rigid sheet signage containing Zink Sulphate as bare chemical class – 1 material PSPA fixed on 3 mm acrylic sheet on both side showing marking (running man, Arrow and Exit) and hanged with the ceiling with chain and fastener including cost of labour & material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work Make PES/Giolite/OMEX
Supply, Installation, Testing and comissioning of 2 KVA UPS cum Inverter with 1 hour Backup. Make LIBERT EINOVA / Luminous/APC/Numereic
Vocational Training block
Supply, Installation, Testing and Commissioning of addressable multisensor smoke detector shall be with built in microprocessor and short circuit isolator capable including common mounting base plug in type and interchangeable with other smoke detector.The alarm LED shall be preferably 360 degree.The static voltage overload protection shall be inbuilt. etc. as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements; Drift Compensation feature & Automatic addressing. Detector should monitor Electromagnetic interference and report to the panel - current and average values.Detector should have IP rated EMC safety for detector shall be 50 V/m. Shall be UL/EN/VDS certification.The Detector shall be fully tested and each detector should bear the SI no and seal of the approving laboratory & complete in all respect. as requied. The panel shall have proper listing and approval from NFPA, UL,ULC, FM, CSFM,LPCB, VDS,BRE AND AS PER RELEVANT IS CODE (Make: Honeywell(Morley) bosch/ Siemens/ edwards/ simplex/Glyptic).
Supplying, installing, testing and commissioning of Addressable Manual Call Point ( Break Glass Type). The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. The panel shall have proper listing and approval from NFPA, UL,ULC, FM, CSFM,LPCB, VDS,BRE AND AS PER RELEVANT IS CODE(Make: Honeywell(Morley) bosch/ Siemens/ edwards/ simplex)
Supplying, installing, testing and commissioning Response indicator for all detectors located above false ceiling.The panel shall have proper listing and approval from NFPA, UL,ULC, FM, CSFM,LPCB, VDS,BRE AND AS PER RELEVANT IS CODE (Make: Honeywell/ bosch/ Siemens/ edwards/ simplex)
Supplying, installing, testing and commissioning of Sounder cum Strobe rated at 80 dBA @ 3m for Audible annunciation and 115cd flashintg at 1 Hz for visual indication. The panel shall have proper listing and approval from NFPA, UL,ULC, FM, CSFM,LPCB, VDS,BRE AND AS PER RELEVANT IS CODE(Make: Honeywell(Morley)(bosch/ Siemens/ edwards/ simplex)
Supply, Installation, Testing and Commissioning of Microprocessor based Intelligent Addressable Main Fire Alarm Control Panel with Suitable Loops modules and each loop capable of supporting not less than 250 devices (detectors & modules should be in any combination) ; Loop length up to 1.5 km, 8" Color LCD touch screen display with bright colors to indicate alarms and events, 4 Nos of Integrated Ethernet Ports & 2 Nos of RS 485 for networking, 200 Nos of Soft programmable keys with status indicators for individual triggering of NAC Ouputs, evacuation speaker zones, AHU Modules, Damper switch, Smoke extraction Fans, Lifts.. etc. The Panel shall support 10000 history logs in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 24 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger.The panel should also have IP30 or better protection. The panel shall have seamless integration with EVAC certified Public Address System and shall be complete with all accessories . EN54 / Vds/UL Certification. Make: Autronica/ Honneywell(Morley) (Notifire) / Bosch
Supply, Installation, Testing and comissioning of single core multistrand 1.5 sq mm annealed copper conductor speaker cable in existing pipe/ channel I/C connection etc.Makes: Finolex/Polycab/ KEI
Supply and erection of 25 mm dia PVC conduit pipe ISI marked (Medium) recessed in wall /ceiling etc. including cost of PVC bends, inspection box and all other material required to complete the job in all respect to the entire satisfaction of Engineer-in-Charge of work Make Diplast/Polyplast/
Supply, Installation, Testing and comissioning of Cabinet Speaker Max Power - 9 W ,Rated power (PHC) - 6 W(6-3-1.5), Sound pressure level at rate power /1 w ,(at1kHz,1m) (at 1 kHz, 1 m) - 96dB/ 90dB,Effective frequency range (-10 dB) - 200-15000 Hz,Opening angle (at 1 kHz/4 kHz, - 6 dB),In degrees - 150/70,Rated voltage - 100 V,Rated impedance - 1667 .Make: Autronica/ Honneywell (Notifire) / Bosch
Supply, Installation, Testing and comissioning of 17U Equipment Rack with provision for housing all control equipment with front & rear door, Blower for cooling and proper locking arrangements and as per the specifications, complete in all respect upto the entire satisfaction of Engineer - in - Charge of the work. Makes: Valrack /Netrack/ Comrack
Supply, Installation, Testing and comissioning of 240 watts mixer amplifier Inbuilt Bluetooth for audio streaming supports audio playback from USB pen drive,4 microphone/line inputs,plus music source inp
ut,insert feature to use as a pre/power amplifier,optional 2 tone chime generation for input 1,frequency response 80 Hz to 18KHz (+1/3dB @ 10 dB ref. rated output),Distortion<1% @ rated output power , 1 KHz,Bass control-Max+- 8dB,Treble control-Max+- 8dB,connector-Clinch stereo converted to mono,Sensitivity-200mV to 300 mV, Impedance-22 Kohm,S/N(flat at max volume) >70dB, Headroom >25dB as required complete in all respects. Makes:-Beyerdynamic/Bosch/TOA/Brahler,Honeywell.
Supply of tabletop Unidirectional Condenser Microphone Voltage range 12 to 48 V current consumption <8mA,Sensitivity 0.7mV@85 dBSPL(2mV/Pa),Maximum input sound level 110dB SPL,Distortion<0.6% (Max input),Input noise level(equiv) 28 dB SPLA (S/N 66dBA Ref,1 Pa), frequency response 100 Hz to 16 KHz Output impedance 200 ohm as required complete in all respects.Makes: Bosch/Sennheiser/Shure.
Supply, Installation, Testing and Commissioning of Glow Type EXIT Sign Board photo luminescent of size 300 mm x 250 mm x 1.5 mm rigid sheet signage containing Zink Sulphate as bare chemical class – 1 material PSPA fixed on 3 mm acrylic sheet on both side showing marking (running man, Arrow and Exit) and hanged with the ceiling with chain and fastener including cost of labour & material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work Make PES/Giolite/OMEX
Supply, Installation, Testing and comissioning of 2 KVA UPS cum Inverter with 1 hour Backup. Make LIBERT EINOVA / Luminous/APC/Numereic.
Supply, Installation, Testing and Commissioning of addressable multisensor smoke detector shall be with built in microprocessor and short circuit isolator capable including common mounting base plug in type and interchangeable with other smoke detector.The alarm LED shall be preferably 360 degree.The static voltage overload protection shall be inbuilt. etc. as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements; Drift Compensation feature & Automatic addressing. Detector should monitor Electromagnetic interference and report to the panel - current and average values.Detector should have IP rated EMC safety for detector shall be 50 V/m. Shall be UL/EN/VDS certification.The Detector shall be fully tested and each detector should bear the SI no and seal of the approving laboratory & complete in all respect. as requied. The panel shall have proper listing and approval from NFPA, UL,ULC, FM, CSFM,LPCB, VDS,BRE AND AS PER RELEVANT IS CODE (Make: Honeywell(Morley) bosch/ Siemens/ edwards/ simplex/Glyptic
Supply, Installation, Testing and Commissioning of intelligent analog addressable heat(static+ROR) with inbuilt turbo isotator and integral respose indicator with 360 degree viewing angle.Detector shall communicate 3 danger levels for differentiated alarm activation.Detector should have unique address of communication and assigned through panel with mounting base as required with the protection category of IP40 and duly approved by EN54/LPCB/VDS/FM (Make: Honeywell (Morley)bosch/ Siemens/ edwards/ simplex/Glyptic)
Supplying, installing, testing and commissioning of Addressable Manual Call Point ( Break Glass Type). The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. The panel shall have proper listing and approval from NFPA, UL,ULC, FM, CSFM,LPCB, VDS,BRE AND AS PER RELEVANT IS CODE (Make: Honeywell(Morley) bosch/ Siemens/ edwards/ simplex
Supplying, installing, testing and commissioning Response indicator for all detectors located above false ceiling.The panel shall have proper listing and approval from NFPA, UL,ULC, FM, CSFM,LPCB, VDS,BRE AND AS PER RELEVANT IS CODE (Make: Honeywell(Morley)bosch/ Siemens/ edwards/ simplex)
Supplying, installing, testing and commissioning of Sounder cum Strobe rated at 80 dBA @ 3m for Audible annunciation and 115cd flashintg at 1 Hz for visual indication. The panel shall have proper listing and approval from NFPA, UL,ULC, FM, CSFM,LPCB, VDS,BRE AND AS PER RELEVANT IS CODE .(Make: Honeywell(Morley)bosch/ Siemens/ edwards/ simplex)
Supply, Installation, Testing and Commissioning of Microprocessor based Intelligent Addressable Main Fire Alarm Control Panel with Suitable Loops modules and each loop capable of supporting not less than 250 devices (detectors & modules should be in any combination) ; Loop length up to 1.5 km, 8" Color LCD touch screen display with bright colors to indicate alarms and events, 4 Nos of Integrated Ethernet Ports & 2 Nos of RS 485 for networking, 200 Nos of Soft programmable keys with status indicators for individual triggering of NAC Ouputs, evacuation speaker zones, AHU Modules, Damper switch, Smoke extraction Fans, Lifts.. etc. The Panel shall support 10000 history logs in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 24 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger.The panel should also have IP30 or better protection. The panel shall have seamless integration with EVAC certified Public Address System and shall be complete with all accessories . EN54 / Vds/UL Certification. Make: Autronica/ Honneywell / Bosch
Supply and erection of 25 mm dia PVC conduit pipe ISI marked (Medium) recessed in wall /ceiling etc. including cost of PVC bends, inspection box and all other material required to complete the job in all respect to the entire satisfaction of Engineer-in-Charge of work. Make Diplast/Polyplast.
Supply, Installation, Testing and comissioning of 2 KVA UPS cum Inverter with 1 hour Backup. Make LIBERT EINOVA / Luminous/APC/Numereic
Supply, Installation, Testing and comissioning of single core multistrand 1.5 sq mm annealed copper conductor speaker cable in existing pipe/ channel I/C connection etc.connection etc.Make Finolex/Polycab/ KEI
Supply, Installation, Testing and Commissioning of intelligent analog addressable heat(static+ROR) with inbuilt turbo isotator and integral respose indicator with 360 degree viewing angle.Detector shall communicate 3 danger levels for differentiated alarm activation.Detector should have unique address of communication and assigned through panel with mounting base as required with the protection category of IP40 and duly approved by EN54/LPCB/VDS/FM (Make: Honeywell(Morley) bosch/ Siemens/ edwards/ simplex/Glyptic)
Supplying, installing, testing and commissioning of Addressable Manual Call Point ( Break Glass Type). The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. The panel shall have proper listing and approval from NFPA, UL,ULC, FM, CSFM,LPCB, VDS,BRE AND AS PER RELEVANT IS CODE (Make: Honeywell(Morley) bosch/ Siemens/ edwards/ simplex)
Supplying, installing, testing and commissioning Response indicator for all detectors located above false ceiling.The panel shall have proper listing and approval from NFPA, UL,ULC, FM, CSFM,LPCB, VDS,BRE AND AS PER RELEVANT IS CODE (Make: Honeywell(Morley) bosch/ Siemens/ edwards/ simplex)
Supplying, installing, testing and commissioning of Sounder cum Strobe rated at 80 dBA @ 3m for Audible annunciation and 115cd flashintg at 1 Hz for visual indication. The panel shall have proper listing and approval from NFPA, UL,ULC, FM, CSFM,LPCB, VDS,BRE AND AS PER RELEVANT IS CODE .(Make: Honeywell(Morley) bosch/ Siemens/ edwards/ simplex)
Supply, Installation, Testing and Commissioning of addressable multisensor smoke detector shall be with built in microprocessor and short circuit isolator capable including common mounting base plug in type and interchangeable with other smoke detector.The alarm LED shall be preferably 360 degree.The static voltage overload protection shall be inbuilt. etc. as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements; Drift Compensation feature & Automatic addressing. Detector should monitor Electromagnetic interference and report to the panel - current and average values.Detector should have IP rated EMC safety for detector shall be 50 V/m. Shall be UL/EN/VDS certification.The Detector shall be fully tested and each detector should bear the SI no and seal of the approving laboratory & complete in all respect. as requied. The panel shall have proper listing and approval from NFPA, UL,ULC, FM, CSFM,LPCB, VDS,BRE AND AS PER RELEVANT IS CODE (Make: Honeywell(Morley)bosch/ Siemens/ edwards/ simplex/Glyptic
Supply, Installation, Testing and comissioning of single core multistrand 1.5 sq mm annealed copper conductor speaker cable in existing pipe/ channel I/C connection etc.Make Finolex/Polycab/ KEI
Supply, Installation, Testing and Commissioning of Microprocessor based Intelligent Addressable Main Fire Alarm Control Panel with Suitable Loops modules and each loop capable of supporting not less than 250 devices (detectors & modules should be in any combination) ; Loop length up to 1.5 km, 8" Color LCD touch screen display with bright colors to indicate alarms and events, 4 Nos of Integrated Ethernet Ports & 2 Nos of RS 485 for networking, 200 Nos of Soft programmable keys with status indicators for individual triggering of NAC Ouputs, evacuation speaker zones, AHU Modules, Damper switch, Smoke extraction Fans, Lifts.. etc. The Panel shall support 10000 history logs in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 24 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger.The panel should also have IP30 or better protection. The panel shall have seamless integration with EVAC certified Public Address System and shall be complete with all accessories . EN54 / Vds/UL Certification. Make: Autronica/ Honneywell (Morley) / Bosch
Supply and erection of 25 mm dia PVC conduit pipe ISI marked (Medium) recessed in wall /ceiling etc. including cost of PVC bends, inspection box and all other material required to complete the job in all respect to the entire satisfaction of Engineer-in-Charge of work. Make Diplast/Polyplast/BEC.
Supply, Installation, Testing and comissioning of 17/18U Equipment Rack with provision for housing all control equipment with front & rear door, Blower for cooling and proper locking arrangements and as per the specifications, complete in all respect upto the entire satisfaction of Engineer - in - Charge of the work. Makes: Valrack /Netrack/ Comrack
Supply, Installation, Testing and comissioning of 240 watts mixer amplifier Inbuilt Bluetooth for audio streaming supports audio playback from USB pen drive,4 microphone/line inputs,plus music source inp
Supply, Installation, Testing and comissioning of Cabinet Speaker Max Power - 9 W ,Rate
Supply, Installation, Testing and Commissioning of Glow Type EXIT Sign Board photo luminescent of size 300 mm x 250 mm x 1.5 mm rigid sheet signage containing Zink Sulphate as bare chemical class – 1 material PSPA fixed on 3 mm acrylic sheet on both side showing marking (running man, Arrow and Exit) and hanged with the ceiling with chain and fastener including cost of labour & material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work Make PES/Giolite/OMEX
Supply, Installation, Testing and comissioning of 2 KVA UPS cum Inverter with 1 hour Backup. Makes: LIBERT EINOVA / Luminous/APC/Numereic
d power (PHC) - 6 W(6-3-1.5), Sound pressure level at rate power /1 w ,(at1kHz,1m) (at 1 kHz, 1 m) - 96dB/ 90dB,Effective frequency range (-10 dB) - 200-15000 Hz,Opening angle (at 1 kHz/4 kHz, - 6 dB),In degrees - 150/70,Rated voltage - 100 V,Rated impedance - 1667 Make: Autronica/ Honneywell (Notifire) / Bosch
Supply, Installation, Testing and Commissioning of addressable multisensor smoke detector shall be with built in microprocessor and short circuit isolator capable including common mounting base plug in type and interchangeable with other smoke detector.The alarm LED shall be preferably 360 degree.The static voltage overload protection shall be inbuilt. etc. as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements; Drift Compensation feature & Automatic addressing. Detector should monitor Electromagnetic interference and report to the panel - current and average values.Detector should have IP rated EMC safety for detector shall be 50 V/m. Shall be UL/EN/VDS certification.The Detector shall be fully tested and each detector should bear the SI no and seal of the approving laboratory & complete in all respect. as requied. The panel shall have proper listing and approval from NFPA, UL,ULC, FM, CSFM,LPCB, VDS,BRE AND AS PER RELEVANT IS CODE (Make: Honeywell(Morley) bosch/ Siemens/ edwards/ simplex/Glyptic
Supply of tabletop Unidirectional Condenser Microphone Voltage range 12 to 48 V current consumption <8mA,Sensitivity 0.7mV@85 dBSPL(2mV/Pa),Maximum input sound level 110dB SPL,Distortion<0.6% (Max input),Input noise level(equiv) 28 dB SPLA (S/N 66dBA Ref,1 Pa), frequency response 100 Hz to 16 KHz Output impedance 200 ohm as required complete in all respects. Makes:-Bosch/Sennheiser/Shure.
Supply, Installation, Testing and Commissioning of intelligent analog addressable heat(static+ROR) with inbuilt turbo isotator and integral respose indicator with 360 degree viewing angle.Detector shall communicate 3 danger levels for differentiated alarm activation.Detector should have unique address of communication and assigned through panel with mounting base as required with the protection category of IP40 and duly approved by EN54/LPCB/VDS/FM (Make: Honeywell(Morley) bosch/ Siemens/ edwards/ simplex/Glyptic)
Supplying, installing, testing and commissioning of Addressable Manual Call Point ( Break Glass Type). The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. The panel shall have proper listing and approval from NFPA, UL,ULC, FM, CSFM,LPCB, VDS,BRE AND AS PER RELEVANT IS CODE (Make: Honeywell(Morley) bosch/ Siemens/ edwards/ simplex).
Supply, Installation, Testing and Commissioning of addressable multisensor smoke detector shall be with built in microprocessor and short circuit isolator capable including common mounting base plug in type and interchangeable with other smoke detector.The alarm LED shall be preferably 360 degree.The static voltage overload protection shall be inbuilt. etc. as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements; Drift Compensation feature & Automatic addressing. Detector should monitor Electromagnetic interference and report to the panel - current and average values.Detector should have IP rated EMC safety for detector shall be 50 V/m. Shall be UL/EN/VDS certification.The Detector shall be fully tested and each detector should bear the SI no and seal of the approving laboratory & complete in all respect. as requied. The panel shall have proper listing and approval from NFPA, UL,ULC, FM, CSFM,LPCB, VDS,BRE AND AS PER RELEVANT IS CODE (Make: Honeywell(Morley)bosch/ Siemens/ edwards/ simplex/Glyptic
Supply, Installation, Testing and comissioning of single core multistrand 1.5 sq mm annealed copper conductor speaker cable in existing pipe/ channel I/C connection etc.Make Finolex/Polycab/ KEI
Supply and erection of 25 mm dia PVC conduit pipe ISI marked (Medium) recessed in wall /ceiling etc. including cost of PVC bends, inspection box and all other material required to complete the job in all respect to the entire satisfaction of Engineer-in-Charge of work. Make Diplast/Polyplast/BEC.
Supplying, installing, testing and commissioning Response indicator for all detectors located above false ceiling.The panel shall have proper listing and approval from NFPA, UL,ULC, FM, CSFM,LPCB, VDS,BRE AND AS PER RELEVANT IS CODE (Make: Honeywell(Morley) bosch/ Siemens/ edwards/ simplex).
Supply, Installation, Testing and comissioning of 17/18U Equipment Rack with provision for housing all control equipment with front & rear door, Blower for cooling and proper locking arrangements and as per the specifications, complete in all respect upto the entire satisfaction of Engineer - in - Charge of the work. Makes: Valrack /Netrack/ Comrack.
Supplying, installing, testing and commissioning of Sounder cum Strobe rated at 80 dBA @ 3m for Audible annunciation and 115cd flashintg at 1 Hz for visual indication. The panel shall have proper listing and approval from NFPA, UL,ULC, FM, CSFM,LPCB, VDS,BRE AND AS PER RELEVANT IS CODE ..(Make: Honeywell(Morley) bosch/ Siemens/ edwards/ simplex).
Supply of tabletop Unidirectional Condenser Microphone Voltage range 12 to 48 V current consumption <8mA,Sensitivity 0.7mV@85 dBSPL(2mV/Pa),Maximum input sound level 110dB SPL,Distortion<0.6% (Max input),Input noise level(equiv) 28 dB SPLA (S/N 66dBA Ref,1 Pa), frequency response 100 Hz to 16 KHz Output impedance 200 ohm as required complete in all respects. Makes:Bosch/Sennheiser/Shure.
Supply, Installation, Testing and comissioning of Cabinet Speaker Max Power - 9 W ,Rated power (PHC) - 6 W(6-3-1.5), Sound pressure level at rate power /1 w ,(at1kHz,1m) (at 1 kHz, 1 m) - 96dB/ 90dB,Effective frequency range (-10 dB) - 200-15000 Hz,Opening angle (at 1 kHz/4 kHz, - 6 dB),In degrees - 150/70,Rated voltage - 100 V,Rated impedance - 1667 .Make: Autronica/ Honneywell (Morley) / Bosch.
Supply, Installation, Testing and comissioning of 2 KVA UPS cum Inverter with 1 hour Backup. Makes: LIBERT EINOVA / Luminous/APC/Numereic
Mahila Sadan(100PAX)
Supply, Installation, Testing and comissioning of 240 watts mixer amplifier Inbuilt Bluetooth for audio streaming supports audio playback from USB pen drive,4 microphone/line inputs,plus music source input,insert feature to use as a pre/power amplifier,optional 2 tone chime generation for input 1,frequency response 80 Hz to 18KHz (+1/3dB @ 10 dB ref. rated output),Distortion<1% @ rated output power , 1 KHz,Bass control-Max+- 8dB,Treble control-Max+- 8dB,connector-Clinch stereo converted to mono,Sensitivity-200mV to 300 mV, Impedance-22 Kohm,S/N(flat at max volume) >70dB, Headroom >25dB as required complete in all respects.Makes:-Beyerdynamic/Bosch/TOA/Brahler,Honeywell(Morley)
Supply, Installation, Testing and Commissioning of Glow Type EXIT Sign Board photo luminescent of size 300 mm x 250 mm x 1.5 mm rigid sheet signage containing Zink Sulphate as bare chemical class – 1 material PSPA fixed on 3 mm acrylic sheet on both side showing marking (running man, Arrow and Exit) and hanged with the ceiling with chain and fastener including cost of labour & material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work Makes: PES/Giolite/OMEX
Supplying, installing, testing and commissioning of Addressable Manual Call Point ( Break Glass Type). The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. The panel shall have proper listing and approval from NFPA, UL,ULC, FM, CSFM,LPCB, VDS,BRE AND AS PER RELEVANT IS CODE(Make: Honeywell(Morley) bosch/ Siemens/ edwards/ simplex)
Supplying, installing, testing and commissioning Response indicator for all detectors located above false ceiling.The panel shall have proper listing and approval from NFPA, UL,ULC, FM, CSFM,LPCB, VDS,BRE AND AS PER RELEVANT IS CODE (Make: Honeywell(Morley) bosch/ Siemens/ edwards/ simplex)
Supply, Installation, Testing and Commissioning of intelligent analog addressable heat(static+ROR) with inbuilt turbo isotator and integral respose indicator with 360 degree viewing angle.Detector shall communicate 3 danger levels for differentiated alarm activation.Detector should have unique address of communication and assigned through panel with mounting base as required with the protection category of IP40 and duly approved by EN54/LPCB/VDS/FM (Make: Honeywell(Morley) bosch/ Siemens/ edwards/ simplex/Glyptic)
Supply, Installation, Testing and Commissioning of addressable multisensor smoke detector shall be with built in microprocessor and short circuit isolator capable including common mounting base plug in type and interchangeable with other smoke detector.The alarm LED shall be preferably 360 degree.The static voltage overload protection shall be inbuilt. etc. as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements; Drift Compensation feature & Automatic addressing. Detector should monitor Electromagnetic interference and report to the panel - current and average values.Detector should have IP rated EMC safety for detector shall be 50 V/m. Shall be UL/EN/VDS certification.The Detector shall be fully tested and each detector should bear the SI no and seal of the approving laboratory & complete in all respect. as requied. The panel shall have proper listing and approval from NFPA, UL,ULC, FM, CSFM,LPCB, VDS,BRE AND AS PER RELEVANT IS CODE (Make: Honeywell(Morley) bosch/ Siemens/ edwards/ simplex/Glyptic.
Supplying, installing, testing and commissioning of Sounder cum Strobe rated at 80 dBA @ 3m for Audible annunciation and 115cd flashintg at 1 Hz for visual indication. The panel shall have proper listing and approval from NFPA, UL,ULC, FM, CSFM,LPCB, VDS,BRE AND AS PER RELEVANT IS CODE ..(Make: Honeywell(Morley)/ bosch/ Siemens/ edwards/ simplex)
Supply and erection of 25 mm dia PVC conduit pipe ISI marked (Medium) recessed in wall /ceiling etc. including cost of PVC bends, inspection box and all other material required to complete the job in all respect to the entire satisfaction of Engineer-in-Charge of work. Make Diplast/Polyplast/BEC.
Supply, Installation, Testing and Commissioning of Microprocessor based Intelligent Addressable Main Fire Alarm Control Panel with Suitable Loops modules and each loop capable of supporting not less than 250 devices (detectors & modules should be in any combination) ; Loop length up to 1.5 km, 8" Color LCD touch screen display with bright colors to indicate alarms and events, 4 Nos of Integrated Ethernet Ports & 2 Nos of RS 485 for networking, 200 Nos of Soft programmable keys with status indicators for individual triggering of NAC Ouputs, evacuation speaker zones, AHU Modules, Damper switch, Smoke extraction Fans, Lifts.. etc. The Panel shall support 10000 history logs in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 24 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger.The panel should also have IP30 or better protection. The panel shall have seamless integration with EVAC certified Public Address System and shall be complete with all accessories . EN54 / Vds/UL Certification. Make: Autronica/ Honeywell(Morley)) / Bosch).
Supply, Installation, Testing and comissioning of 17/18U Equipment Rack with provision for housing all control equipment with front & rear door, Blower for cooling and proper locking arrangements and as per the specifications, complete in all respect upto the entire satisfaction of Engineer - in - Charge of the work. Makes: Valrack /Netrack/ Comrack
Supply, Installation, Testing and comissioning of single core multistrand 1.5 sq mm annealed copper conductor speaker cable in existing pipe/ channel I/C connection etc..Make Finolex/Polycab/ KEI
Supply of tabletop Unidirectional Condenser Microphone Voltage range 12 to 48 V current consumption <8mA,Sensitivity 0.7mV@85 dBSPL(2mV/Pa),Maximum input sound level 110dB SPL,Distortion<0.6% (Max input),Input noise level(equiv) 28 dB SPLA (S/N 66dBA Ref,1 Pa), frequency response 100 Hz to 16 KHz Output impedance 200 ohm as required complete in all respects. Makes: Bosch/Sennheiser/Shure.
Supply, Installation, Testing and Commissioning of Glow Type EXIT Sign Board photo luminescent of size 300 mm x 250 mm x 1.5 mm rigid sheet signage containing Zink Sulphate as bare chemical class – 1 material PSPA fixed on 3 mm acrylic sheet on both side showing marking (running man, Arrow and Exit) and hanged with the ceiling with chain and fastener including cost of labour & material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work Make PES/Giolite/OMEX
Supply, Installation, Testing and comissioning of 2 KVA UPS cum Inverter with 1 hour Backup. Makes: LIBERT EINOVA / Luminous/APC/Numereic
Senior Citizen(100PAX).
Supply, Installation, Testing and comissioning of Cabinet Speaker Max Power - 9 W ,Rated power (PHC) - 6 W(6-3-1.5), Sound pressure level at rate power /1 w ,(at1kHz,1m) (at 1 kHz, 1 m) - 96dB/ 90dB,Effective frequency range (-10 dB) - 200-15000 Hz,Opening angle (at 1 kHz/4 kHz, - 6 dB),In degrees - 150/70,Rated voltage - 100 V,Rated impedan
ce - 1667 Make: Autronica/ Honneywell (Notifire) / Bosch
Supply, Installation, Testing and comissioning of 240 watts mixer amplifier Inbuilt Bluetooth for audio streaming supports audio playback from USB pen drive,4 microphone/line inputs,plus music source input,insert feature to use as a pre/power amplifier,optional 2 tone chime generation for input 1,frequency response 80 Hz to 18KHz (+1/3dB @ 10 dB ref. rated output),Distortion<1% @ rated output power , 1 KHz,Bass control-Max+- 8dB,Treble control-Max+- 8dB,connector-Clinch stereo converted to mono,Sensitivity-200mV to 300 mV, Impedance-22 Kohm,S/N(flat at max volume) >70dB, Headroom >25dB as required complete in all respects. Makes:-Beyerdynamic/Bosch/TOA/Brahler,Honeywell(Morley)
Supply, Installation, Testing and Commissioning of intelligent analog addressable heat(static+ROR) with inbuilt turbo isotator and integral respose indicator with 360 degree viewing angle.Detector shall communicate 3 danger levels for differentiated alarm activation.Detector should have unique address of communication and assigned through panel with mounting base as required with the protection category of IP40 and duly approved by EN54/LPCB/VDS/FM (Make: Honeywell(Morley)/ bosch/ Siemens/ edwards/ simplex/Glyptic)
Supply, Installation, Testing and Commissioning of addressable multisensor smoke detector shall be with built in microprocessor and short circuit isolator capable including common mounting base plug in type and interchangeable with other smoke detector.The alarm LED shall be preferably 360 degree.The static voltage overload protection shall be inbuilt. etc. as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements; Drift Compensation feature & Automatic addressing. Detector should monitor Electromagnetic interference and report to the panel - current and average values.Detector should have IP rated EMC safety for detector shall be 50 V/m. Shall be UL/EN/VDS certification.The Detector shall be fully tested and each detector should bear the SI no and seal of the approving laboratory & complete in all respect. as requied. The panel shall have proper listing and approval from NFPA, UL,ULC, FM, CSFM,LPCB, VDS,BRE AND AS PER RELEVANT IS CODE (Make: Honeywell(Morley)/ bosch/ Siemens/ edwards/ simplex/Glyptic)
Supplying, installing, testing and commissioning of Addressable Manual Call Point ( Break Glass Type). The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. The panel shall have proper listing and approval from NFPA, UL,ULC, FM, CSFM,LPCB, VDS,BRE AND AS PER RELEVANT IS CODE (Make: Honeywell(Morley)/ bosch/ Siemens/ edwards/ simplex)
Supply, Installation, Testing and comissioning of single core multistrand 1.5 sq mm annealed copper conductor speaker cable in existing pipe/ channel I/C connection etc.Make Finolex/Polycab/ KEI
Supply and erection of 25 mm dia PVC conduit pipe ISI marked (Medium) recessed in wall /ceiling etc. including cost of PVC bends, inspection box and all other material required to complete the job in all respect to the entire satisfaction of Engineer-in-Charge of work. Make Diplast/Polyplast/BEC.
Supplying, installing, testing and commissioning Response indicator for all detectors located above false ceiling.The panel shall have proper listing and approval from NFPA, UL,ULC, FM, CSFM,LPCB, VDS,BRE AND AS PER RELEVANT IS CODE (Make: Honeywell(Morley)/ bosch/ Siemens/ edwards/ simplex)
Supplying, installing, testing and commissioning of Sounder cum Strobe rated at 80 dBA @ 3m for Audible annunciation and 115cd flashintg at 1 Hz for visual indication. The panel shall have proper listing and approval from NFPA, UL,ULC, FM, CSFM,LPCB, VDS,BRE AND AS PER RELEVANT IS CODE (Make: Honeywell(Morley)/ bosch/ Siemens/ edwards/ simplex)
Supply, Installation, Testing and Commissioning of Microprocessor based Intelligent Addressable Main Fire Alarm Control Panel with Suitable Loops modules and each loop capable of supporting not less than 250 devices (detectors & modules should be in any combination) ; Loop length up to 1.5 km, 8" Color LCD touch screen display with bright colors to indicate alarms and events, 4 Nos of Integrated Ethernet Ports & 2 Nos of RS 485 for networking, 200 Nos of Soft programmable keys with status indicators for individual triggering of NAC Ouputs, evacuation speaker zones, AHU Modules, Damper switch, Smoke extraction Fans, Lifts.. etc. The Panel shall support 10000 history logs in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 24 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger.The panel should also have IP30 or better protection. The panel shall have seamless integration with EVAC certified Public Address System and shall be complete with all accessories . EN54 / Vds/UL Certification. Make: Autronica/ Honeywell(Morley)) / Bosch)
Supply of tabletop Unidirectional Condenser Microphone Voltage range 12 to 48 V current consumption <8mA,Sensitivity 0.7mV@85 dBSPL(2mV/Pa),Maximum input sound level 110dB SPL,Distortion<0.6% (Max input),Input noise level(equiv) 28 dB SPLA (S/N 66dBA Ref,1 Pa), frequency response 100 Hz to 16 KHz Output impedance 200 ohm as required complete in all respects. Makes: Bosch/Sennheiser/Shure.
Supply of tabletop Unidirectional Condenser Microphone Voltage range 12 to 48 V current consumption <8mA,Sensitivity 0.7mV@85 dBSPL(2mV/Pa),Maximum input sound level 110dB SPL,Distortion<0.6% (Max input),Input noise level(equiv) 28 dB SPLA (S/N 66dBA Ref,1 Pa), frequency response 100 Hz to 16 KHz Output impedance 200 ohm as required complete in all respects.Makes: Bosch/Sennheiser/Shure.
Supply, Installation, Testing and comissioning of Cabinet Speaker Max Power - 9 W ,Rated power (PHC) - 6 W(6-3-1.5), Sound pressure level at rate power /1 w ,(at1kHz,1m) (at 1 kHz, 1 m) - 96dB/ 90dB,Effective frequency range (-10 dB) - 200-15000 Hz,Opening angle (at 1 kHz/4 kHz, - 6 dB),In degrees - 150/70,Rated voltage - 100 V,Rated impedance - 1667.Make: Autronica/ Honneywell (Notifire) / Bosch
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.48 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.00 MB
BOQ_175568.xls
BOQ • 0.48 MB
GCCAlarm.pdf
Tender Documents • 4.37 MB
Declaration.pdf
Additional Documents • 0.01 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .