Loading…
Loading…
Tender Value
₹42,351
EMD Value
₹1,059
Closing Date
6 Oct 2026, 6:00 pm
Assistant Executive Engineer
Electrical Wing Irrigation Subdivision Chalakkudy
GENERAL ICC buildings additions to EI PSM Annual maintenance of various Buildings in ICC compound for the year 2025 26 General Electrical Work
2026_Irrig_872870_1
C-ETN-SEP/EL/2026-27
Open Tender
Electrical Works
Item Rate
90 days
Chalakkudy
Please refer Tender documents.
10 documents required · 10 mandatory
₹335
₹1,059
25 Sept 2026
25 Sept 2026
8 Oct 2026
25 Sept 2026
6 Oct 2026
25 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Rewiring | |||||
| 1.001 | 1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm | 50 | metre | - | - |
| 1.002 | OD138929/2026-2027:Supplying and clamping the following sizes of corrugated pvc flexible conduit with
necessary compression gland with locking ring and check nut at termination
pointed using suitable size GI/painted MS saddles spacing not exceeding 60 cms
on surface including making good the damages.20 mm dia . | 11 | metre | - | - |
| 1.003 | 1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm | 40 | metre | - | - |
| 1.004 | 2.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCB
distribution board, 240 volts, on surface/ recess, complete with tinned copper
bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted
including earthing etc. as required. (But without MCB/RCCB/Isolator)
12 way, Double door | 1 | each | - | - |
| 1.005 | 2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature
circuit breaker suitable for inductive load of following poles in the existing MCB
DB complete with connections, testing and commissioning etc. as required.
Single pole | 8 | each | - | - |
| 1.006 | 2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps | 2 | each | - | - |
| 1.007 | 2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.
25 amps | 1 | each | - | - |
| 1.008 | OD138836/2026-2027:Supply & installation of light fittings suspended on ball & socket arrangement with 19 mm down rod Supply, conveyance, installation, testing and commissioning the light fittings of following types made of .5mm thick CRCA sheet accessories and lamps etc. including supplying and fixing ball and socket arrangements on PVC round block, suspension down rod of 19mm dia MS conduit up to 2x30cm length including painting and wiring the down rod with 16/0.20mm 3 core round copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connections etc. a required.LED light fittings made of CRCA sheet with 0.5mm thickness complete with all accessories and lamps etc. 1200 mm 20 W T8 LED tube , having total efficiency of 100 Lumen /watt with 4 feet Aluminium extrusion in the tube for better heat dissipation,, THD < 20% PF> 0.95 ( LM 79 & LM 80 Certificate from NABL should be submitted ) | 12 | each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.04 MB
Tendernotice_2.pdf
PDF • 0.47 MB
BOQ_1480442.xls
BOQ • 0.30 MB
ICCbuildings10348SBDmerged.pdf
Tender Documents • 2.13 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .