Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.9 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹9.0 L+₹97,910 (12.3%)Rejected-Finance | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹9.7 L+₹1.8 L (22.1%)Rejected-Finance 63 TALLA GAON POST UNCHAKOT DISTT NAINITAL 263134 UK | NAINITAL | NAINITAL | UTTARAKHAND | 263134 | L3 | Rejected-Finance Not Being L1 |
Tender Value
₹9.5 L
EMD Value
₹28,500
Closing Date
19 Jul 2023, 6:00 pmClosed
AGE (I) RnD Haldwani
AGE (I) RnD Haldwani PO Arjunpur UK 263139
REPAIR / REPLACEMENT OF LT UG CABLES, MCCBS, LT SWITCH GEARS, LT PANELS, TRANSFORMERS, VCBS, AND OTHER MISC EXTERNAL ELECTRIC WORKS AT DIBER HALDWANI
2023_MES_605017_1
AGE (I)/RnD/HLD-17 of 2023-2024
Open Tender
Civil Works
Item Rate
334 days
DIBER HALDWANI
8 documents required · 8 mandatory
₹500
Yes
AGE (I) RnD Haldwani
₹28,500
Yes
12 Aug 2023
22 Jun 2023
21 Jul 2023
22 Jun 2023
19 Jul 2023
6 Jul 2023
Amount
Contract Details
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr depth for taking out/for laying under ground cables/pipes etc and getting out any type soil all as dircted
Returning filling in including spreading, levelling, watering and well ramming in layers n-exc 25 cm
Removing excavated soil to a distance n-exc 50 mtr and depositing where directed at a level n-exc 1.5 mtr above the starting point
Supply and spreading fine river sand in trenches for cushioning of under ground cable/filling cable ducts all as directed by Engr-in-Charge at site Note : - Only punned thickness shall be measured for payment purpose
Supply and laying common burnt clay building bricks sub class "B" designation 75 old size bricks for cable protection
Relaying the burnt bricks/cable cover in the trenches for cable protection obtain from item No-34
Supply and jointing straight through joint kit epoxy type suitable for 3.5/4 core 35 sq mm 1100 volts for under ground cable any type complete including ferrules as per required size of Make M Seal /Denson/Raychem
All as per item No 8 above but 3.5 core 50 sq mm
All as per item No 8 above but 3.5 core 70 sq mm
All as per item No 8 above but 3.5 core 95 sq mm
All as per item No 8 above but 3.5 core 120/150 sq mm
All as per item No 9 above but 3.5 core 185 sq mm
Taking down unservicable/rusted GI tubes of size 50 to 80 mm dia from poles/trenches and making good the disturbed surface if required of the following sizes
Supply and fixing of HDPE pipe PN 10 for cable protection , laid in trenches for passing LT cables of sizes 65 mm dia
All as per item No 15 above but 50 mm dia
Supply & Fixing on load change over switch 4 poles capacity 200 Amp 415 Volts 50 Hz including taking down old u/s change over switch and testing complete all as specified Make : HPL/Indoasion/L&T/Havells
Supply and fix MCCB 415 volts, 3 phase, 50 Hz, 4 pole of capacity 63 Amps 10 KA including taking down old unseviceable MCCB all as directed by Engr-in-Charge. Make : L&T/Indo asian/ABB/Havells
All as per item No 18 above but capacity 100 Amps 16 KA
All as per item No 18 above but capacity 125 Amps 16 KA
All as per item No 18 above but capacity 200 Amps 25 KA
All as per item No 18 above but capacity 250 Amps 25 KA
All as per item No 18 above but capacity 320 Amps 36 KA
All as per item No 18 above but capacity 400 Amps 36 KA
Supply, laying and connecting up armoured LT XLPE insulated heavy duty electric cable with aluminium stranded conductor, 1100 volts grade, cross sectional area 4 core 16 sq mm including taking out old unserviceable cable all as directed. Make: Universal/Nicco/Mescab/Polycab/Havells
All as per item No 25 above but 10 sq mm 4 core
All as per item No 25 above but 25 sq mm 3.5 core
All as per item No 25 above but 50 sq mm 3.5 core
All as per item No 25 above but 35 sq mm 3.5 core
All as per item No 25 above but 70 sq mm 3.5 core
All as per item No 25 above but 95 sq mm 3.5 core
All as per item No 25 above but 150 sq mm 3.5 core
All as per item No 25 above but 300 sq mm 3.5 core
Taking down existing LT UG Cable upto 150 Sqmm from trenches including old bricks and relaying the same after fault rectification by jointing of cable etc all as directed. Note:- earth work, excavation, bricks/cable cover ,sand and cable joints paid and measured separately
Supply and fixing MCCB enclosure suitable for upto 200 Amps complete with fixing arrangment. Make: Havells/Indo Asian/L&T
M&L for cement concrete type D2 1:4:8 using 40 mm graded aggregate for making good surfaces in road cutting, pole foundation, stay concrete etc all as directed
M&L for cutting out concrete blocks, slabs, brick work or stone masonary (in alternative course) forming, toothings for and bonding new work in mortar into old work, including new materials entering old wall set in cement mortor 1:6 with pre cast cement concrete type B1, 1:2:4 (20 mm graded aggregate) all as directed and specified.
M&L for plain cement concrete type C2(1:3:6) using 40 mm graded stone aggregate as in coping including necessary form work and finishing exposed surface/white washing all as directed.
Taking out the LT air circuit breakers up to 800 Amps capacity AC 440 volts from existing panel for repairs and replacement of worn out parts including complete servicing and refixing in original position testing & commissioning complete all as specified and as directed Note :- Spares will be measured and paid separately
Supply only shunt trip/closing coil 220 VAC/415 VAC
Supply only Under Voltage Trip device (UVT) 220 volts AC
Supply only Under Voltage Trip device (UVT) 415 Volt AC
Supply only On/Off button cover
Supply only trip indication switch
Supply and fix ACB 4 Pole, 415 V, with Thermal Magnetic Release (Manual Drawout type) of capacity 800 Amps, fixing in the existing panel including taking out old unserviceable ACB
Supply and fixing of Indicating lamp assembly complete LED type of colour red, yellow, blue, green complete all as directed
M&L for synthetic insulating mat of size 2 mtr x 1 mtr x 2.5mm thick for voltage upto 11 KV complete all as directed
M&L for synthetic insulating mat of size 2 mtr x 1 mtr x 2.0 mm thick for voltage upto 3.3 KV complete all as directed
Providing and fixing earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. Details of cost for one Set
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc.as required.
Providing and fixing earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. Details of cost for one Set
Providing and fixing 25mm x 5mm copper strip on surface or in recess for connection etc. as required.
S&F cast iron cable route indicator in round shape duly marked/engraved "CABLE LT 1.1 KV" fixed on PCC block of suitable size all as directed by the Engineer in charge
M & L for gang operated switches air break, triple pole, 11000 volts mechanically operated, mounted on insulator and steel frame, with operating mechanism worked from ground level, for current rating upto 400 Amps. Make : Jaipuria brother,Mahinder Bedi, GEC,Pactil, Alsthom.
Dismantling damaged unserviceable lightning arrestor expulsion type complete and S&F Lightning arrestor expulsion type complete with all fittings, transmission class, High Tension discharge Capacity 65 KA suitable for 11000 volts. Make : Oblum. Jayashree. MEI
Disconecting of cables from HT VCB panel cheking of earth fault and over current relays testing of relays with the help of relay testing kit (boosting Kit) and resetting of relays as per desire load current reconnecting the cables ,including calibaration of relays, for proper tripping and functioning and replacement of U/S parts if required and testing complete for tripping all as directed by Engineer-in-Charge.(Note: Spares required for replacement will be paid and measured separately)
Supply and fix three phase over current and earth fault relay CT rating 1 Amps to 5 Amps 20/110 volts or 88/264 volts suitable for existing breakers make L&T or equivalent
Supply and fix triping coil DC 24/110 Volts suitable for existing breakers
M&L for servicing of breakers mechanical parts including greasing of moving parts and checking of spring charging motor for its proper functioning and testing reseting the same all as directed.
M&L for one coat of aluminium painting to HT steel tubular two pole structure upto 11 mtr long poles including angle iron cross arms channels clamps etc complete including preparation of old painted surfaces all as directed and specified by Engr-in-Charge.
Taking out the sample of transformer oil from bottom portion of each transformer at various locations for checking the di-electric strength and acidity test of oil for the presence of moisture, impurities etc before and after including dehydration (filtration) of transformer oil through mobile filtration plant to be toed to respective location duly connecting inlet/outlet to the machinery by switching off HT power supply taking all safety precautions, so as to achieve di-electric strength not less than 40 KV per minute repturing capacity, switch on supply including commissioning of transformer all as directed.
Supply, fill and topping up transformer oil duly tested for proper di electric strength,upto desired marked level after heating up oil in each transfomer HT switch gear all as directed.
M&L for replacement of silica gel of transformer breather all as directed.
Supply only electric rubber hand gloves 11 KV
Supply only HT digital type ammeter suitable for CT ratio 40/80 Amps including wiring and taking out u/s ammeter all as specified and direct.
Supply and fixing PT fuse 11000 volts 2 Amps capacity.
M&L for spray painting distribution transformer after removing the existing oil stains by paint removers, cleaning with scrapers, preparing surface and painting with two coats of grey synthetic enamel paint over a coat of red oxide primer incl writing SM/MES No whith white enamel paint all as directed for upto 630 KVA capacity transformer.
Note :-Tenderers may be noted that amount of credit will be deducted from the total amount arrived, at the time of Acceptance of contract.
M/S HIMALAYA ENTERPRISES
JAGAT POWER ELCTRICAL
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .