Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.3 LAccepted-AOC NO 15 THIYAGI ARANGANATHAN SUBWAY 70 FEET ROAD KAVERI NAGAR SAIDAPET CHENNAI 600 015 | CHENNAI | TAMIL NADU | 600015 | L1 | Accepted-AOC Lowest Offer | |
| 2 | L2₹7.4 L+₹10,000 (1.36%)Rejected-Finance 276 6 GK COMPLEX AYYALU MEENAKSHI NAGAR UDUMAIPET TIRUPUR 642128 | TIRUPPUR | TAMIL NADU | 642128 | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹9.2 L+₹1.9 L (25.2%)Rejected-Finance | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹14.5 L+₹7.2 L (97.5%)Rejected-Finance | L4 | Rejected-Finance Not Lowest |
Tender Value
Refer Docs
EMD Value
₹31,000
Closing Date
30 Jan 2025, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
General Manager, Projects
PMD Office, TNPL Unit I, Kagithapuram.
Supply and Installation of Gypsum Board and Calcium Silicate False Roofing at Male Bachelors Hostel at TNPL Unit II
2025_TNPL_519183_1
TNPL/PMD/CIV/CB/UNIT II/242523003649
Open Tender
Civil Works
Tender cum Auction
45 days
TNPL Unit II, Kagithanagar, Mondipatti, Manapparai.
As per Invitation for Bids of Bid Document
5 documents required · 5 mandatory
₹0
₹31,000
18 Feb 2025
20 Jan 2025
31 Jan 2025
20 Jan 2025
30 Jan 2025
20 Jan 2025
Amount
"PROVIDING AND FIXING A GYPSUM BOARD FALSE CEILING OF GYPROC-SAINT GOBAIN MAKE AT ALL HEIGHTS WITH A FRAMEWORK OF GYPROC-SAINT GOBAIN MAKE( ULTRA) GALVANIZED M.S. SECTIONS (120 GMS/SQM ZINC COATING AS PER IS: 277). THE FRAMEWORK INCLUDES ANGLE CLEATS (25X1.6MM) FIXED TO THE CEILING WITH DASH FASTENERS, ANGLE HANGERS (25X10X0.50MM), INTERMEDIATE G.I. CHANNELS (45X15X0.9MM) AT 1200MM CENTERS, AND CEILING SECTIONS (0.5MM THICK) SPACED AT 450MM CENTERS, FIXED USING G.I. WIRE CLIPS. PERIMETER CHANNELS (0.5MM THICK, 27MM HIGH) ARE FIXED TO WALLS/PARTITIONS USING RAWL PLUGS AND SCREWS. GYPSUM BOARDS (12.5MM THICK AS PER IS: 2095-PART I: 2011) ARE SECURED TO THE FRAMEWORK WITH DRYWALL SCREWS AND FINISHED WITH JOINTING COMPOUND, TAPE, AND PRIMER AS PER THE MANUFACTURER’S SPECIFICATIONS. OPENINGS FOR FITTINGS, GRILLS, AND CUTOUTS ARE INCLUDED. RATES COVER BOTH VERTICAL AND HORIZONTAL SURFACES, WITH CERTIFICATION OF MEASUREMENTS BASED ON ACTUAL MEASURED ""SEEN"" AREAS OF VERTICAL AND HORIZONTAL. PAINTING IS EXCLUDED."
"PROVIDING AND FIXING 12.5 MM THICK DENSIFIED, TEGULAR-EDGED, ECO-FRIENDLY, LIGHTWEIGHT CALCIUM SILICATE GRID FALSE CEILING TILES OF AEROLITE/RAMCO-HILUX MAKE, SIZE 595 X 595 MM, AT ALL HEIGHTS AND TRUE HORIZONTAL LEVELS. THE TILES WILL BE SUSPENDED ON AN INTERLOCKING METAL GRID OF HOT-DIPPED GALVANIZED STEEL (GALVANIZING @ 120 GRAMS PER SQM), CONSISTING OF MAIN ‘T’ RUNNERS (24 X 38 MM, 0.33 MM THICK), SPACED 1200 MM APART, AND CROSS ‘T’ RUNNERS (24 X 28 MM, 0.33 MM THICK), SPACED 600 MM APART TO FORM A 1200 X 600 MM GRID. SECONDARY CROSS ‘T’ RUNNERS (24 X 28 MM, 0.33 MM THICK, 600 MM LONG) WILL INTERLOCK AT THE CENTER OF THE PANEL TO FORM A 600 X 600 MM GRID. THE GRID WILL BE SUPPORTED ON PERIMETER WALL ANGLES (24 X 24 X 3000 MM, 0.40 MM THICK) WITH RAWL PLUGS AT 450 MM INTERVALS AND DRYWALL SCREWS AT 230 MM INTERVALS. THE TILES WILL BE CUT AND FITTED AROUND SERVICES SUCH AS DIFFUSERS, GRILLS, LIGHT FIXTURES, AND SMOKE DETECTORS, AS REQUIRED. THE MAIN ‘T’ RUNNERS WILL BE SUSPENDED FROM THE CEILING USING G.I. SLOTTED CLEATS (25 X 35 X 1.6 MM) FIXED WITH 12.5 MM DIAMETER DASH FASTENERS, 4 MM G.I. ADJUSTABLE RODS WITH GALVANIZED STEEL LEVEL CLIPS (85 X 30 X 0.8 MM) SPACED 1200 MM APART. THE EXPOSED 24 MM PORTION OF ALL T-SECTIONS WILL BE PRE-PAINTED WITH POLYESTER BAKED PAINT. THE FALSE CEILING WILL BE INSTALLED AS PER THE SPECIFICATIONS, DRAWINGS, AND INSTRUCTIONS FROM THE ENGINEER-IN-CHARGE. NOTE: ONLY THE AREA OF THE CALCIUM SILICATE FALSE CEILING WILL BE MEASURED, FROM WALL TO WALL. THE CALCIUM SILICATE TILES WILL HAVE AN NRC VALUE OF 0.50 (MINIMUM), LIGHT REFLECTION >85%, NON-COMBUSTIBILITY AS PER B.S. 476 PART IV, 100% HUMIDITY RESISTANCE, AND THERMAL CONDUCTIVITY <0.043 W/MK.**"
Bidder Name
Amount in Words
KONGUNADU INFRASTRUCTURE LLP (BID ID -1241571)
MAARUTHI BUILDERS (BID ID -1239173)
COASTAL DELTA BUSINESS CORPORATION (BID ID -1241584)
CROWN ENTERPRISES (BID ID -1241070)
MAARUTHI BUILDERS (BID ID -1239173)
CROWN ENTERPRISES (BID ID -1241070)
KONGUNADU INFRASTRUCTURE LLP (BID ID -1241571)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .